Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Application Abstraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Experimental Study of Eutectic Molten Salts NaCl/KCl/ZnCl2 Heat Transfer Inside a Smooth Tube for High-Temperature Application

Abstract Eutectic salts NaCl-KCl-ZnCl2 and NaCl-KCl-MgCl2 are two of the chloride salt systems that are promising for being used as high-temperature heat transfer fluid (HTF) and thermal energy storage (TES) materials in a wide range of temperatures from 230 °C to 750 °C in concentrated solar thermal power systems. To conduct measurement of the heat transfer coefficient of the molten salt at high temperatures, a circulation system and instrumentation of flow and heat transfer was constructed. Experimental measurement of the convective heat transfer coefficients of NaCl-KCl-ZnCl2 (molar fraction: 13.8–41.9–44.3%) inside tubes has been accomplished to find the most suitable heat transfer correlations. Experience of salt processing and operation of the high-temperature heat transfer test system was obtained. Two correlations, Dittus-Boelter equation and Gnielinski’s correlation for Nusselt number against Reynolds number and Prandtl number, are evaluated using the test results, and the latter correlation is recommended due to its better agreement of prediction against tested data.

Energy & Fuels↗

Design of a Compact Dry Cooler With an Aluminum Heat Exchanger Core for a Supercritical CO2 Power Cycle Is Evaluated for a Concentrating Solar Power Application

Abstract As the supercritical CO2 power cycle develops and the component technologies mature, there is still a need to reduce the associated capital and operating costs to maintain a competitive levelized cost of electricity (LCOE) in order to enter the market. When considering concentrating solar power (CSP) coupled with an sCO2 power block and sensible thermal storage, the technology presents a clean source for utility-scale power generation to support baseload or peak-load electrical demand. However, the LCOE of the technology is still considered higher than the competing technologies and should be reduced to better compete in the market; 2030 targets for dispatchable solar plants are 5¢/kWh for baseload CSP and 10¢/kWh for peaker plants, as set by the United States Department of Energy. In response to this need, this study is targeting improvements in the power cycle precooler to reduce power block contribution to LCOE. This study considers a dry cooler, as CSP plants are sensitive to water consumption because many installations are slated for remote or arid locations where solar irradiance is very high, but water is scarce. Furthermore, the power block footprint for an sCO2 system is quite compact, especially as compared to a steam cycle. Therefore, there is interest in installing a more compact dry cooler that is proportional to the reduced footprint sCO2 power block, while conventional dry coolers are an order of magnitude larger. The competing goals of size, performance, and cost were considered in this study to develop a compact dry cooler that can easily be packaged with the power block, significantly reducing the installation and transport cost compared to the current state of the art, while maintaining or improving upon the heat transfer performance and impact on plant LCOE. This paper details the high-level findings of a large dry cooler sensitivity study for design point selection, design of the compact dry cooler, expected year-round performance for the dry cooler and the power cycle, and the predicted LCOE for a 30-year plant life. It was found that an aluminum heat exchanger core can be suitably designed to meet the pressure and temperature requirements for a precooler in an sCO2 recompression Brayton cycle. The dry cooler assembly was found to have improved heat transfer performance, allowing for increased cycle efficiencies and a reduced plant LCOE. When coupled with a centrifugal blower and compact transition duct, the dry cooler assembly was able to reduce the installation footprint by over 50%.

14 SOLAR ENERGY↗

Design of an Additively Manufactured Recuperator With 800 °C Inlet Temperature for sCO2 Power Cycle Application

Abstract Recuperators with design temperatures at and above 800 °C can further increase the thermal efficiency of supercritical CO2 power cycles by enabling higher turbine exhaust temperatures. Mar-M247 is a well-suited nickel-based superalloy for high temperature service due to its high creep strength that prevents excessive material thickness being required for pressure containment. Additive manufacturing using a high-speed laser-directed energy deposition (L-DED) process presents a promising solution, with build trials demonstrating the ability to produce nonconventional flow channels for enhanced heat transfer. A design process is presented that includes aerothermal and mechanical evaluation to maximize performance within the constraints of the manufacturing process. A 2-D heat transfer network and pressure drop code allows prediction of flow distribution and its effect on overall thermal performance. Established literature correlations, along with CFD simulation, inform the prediction of heat transfer coefficients and friction factors for the flowpaths and enhancement features in the heat exchanger core. Mechanical evaluation using finite element analysis (FEA) modeling with the intent of the ASME Boiler & Pressure Vessel Code (BPVC) Section VIII, Div. 2 assesses the operational safety of the design. The detailed design features annular finned passages that take advantage of helical flow paths to distribute the flow from separated headers to shared heat transfer surfaces. Performance predictions for the recuperator at a 50 kW scale provide insights into the feasibility of the additively manufactured (AM) process to produce recuperators on a commercial scale that extend existing operating envelopes.

Engineering↗

A Constrained Data Assimilation Algorithm Based on GSI Hybrid 3D-EnVar and Its Application

Abstract Data assimilation (DA) at mesoscales is important for severe weather forecasts, yet the techniques of data assimilation at this scale remain a challenge. This study introduces dynamical constraints in the Gridpoint Statistical Interpolation (GSI) three-dimensional ensemble variational (3D-EnVar) data assimilation algorithm to enable the use of high-resolution surface observations of precipitation to improve atmospheric analysis at mesoscales. The constraints use the conservations of mass and moisture. Mass constraint suppresses the unphysical high-frequency oscillation, while moisture conservation constrains the atmospheric states to conform with the observed high-resolution precipitation. We show that the constrained data assimilation (CDA) algorithm significantly reduced the spurious residuals of the mass and moisture budgets compared to the original data assimilation (ODA). A case study is presented for a squall line over the Southern Great Plains on 20 May 2011 during Midlatitude Continental Convective Clouds Experiment (MC3E) of the Atmospheric Radiation Measurement (ARM) program by using ODA or CDA analysis as initial condition of forecasts. The state variables, and the location and intensity of the squall line are better simulated in the CDA experiment. Results show how surface observation of precipitation can be used to improve atmospheric analysis through data assimilation by using the dynamical constraints of mass and moisture conservations.

Wang, Jia↗