Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Angular Reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Lincoln and Stuver reply

We would like to thank Professor Burko for his careful reading of our article and concede that we were in error. Using the same reference he cited, we find that for circular orbits that the fractional rate of angular momentum radiation exceeds the fractional energy radiation (

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In vivo verification of proton beam path by using post-treatment PET/CT imaging

Purpose: The purpose of this study is to establish the in vivo verification of proton beam path by using proton-activated positron emission distributions. Methods: A total of 50 PET/CT imaging studies were performed on ten prostate cancer patients immediately after daily proton therapy treatment through a single lateral portal. The PET/CT and planning CT were registered by matching the pelvic bones, and the beam path of delivered protons was defined in vivo by the positron emission distribution seen only within the pelvic bones, referred to as the PET-defined beam path. Because of the patient position correction at each fraction, the marker-defined beam path, determined by the centroid of implanted markers seen in the post-treatment (post-Tx) CT, is used for the planned beam path. The angular variation and discordance between the PET- and marker-defined paths were derived to investigate the intrafraction prostate motion. For studies with large discordance, the relative location between the centroid and pelvic bones seen in the post-Tx CT was examined. The PET/CT studies are categorized for distinguishing the prostate motion that occurred before or after beam delivery. The post-PET CT was acquired after PET imaging to investigate prostate motion due to physiological changes during the extended PET acquisition. Results: The less than 2 deg. of angular variation indicates that the patient roll was minimal within the immobilization device. Thirty of the 50 studies with small discordance, referred as good cases, show a consistent alignment between the field edges and the positron emission distributions from the entrance to the distal edge. For those good cases, average displacements are 0.6 and 1.3 mm along the anterior-posterior (D{sub AP}) and superior-inferior (D{sub SI}) directions, respectively, with 1.6 mm standard deviations in both directions. For the remaining 20 studies demonstrating a large discordance (more than 6 mm in either D{sub AP} or D{sub SI}), 13 studies, referred as motion-after-Tx cases, also show large misalignment between the field edge and the positron emission distribution in lipomatous tissues around the prostate. These motion-after-Tx cases correspond to patients with large changes in volume of rectal gas between the post-Tx and the post-PET CTs. The standard deviations for D{sub AP} and D{sub SI} are 5.0 and 3.0 mm, respectively, for these motion-after-Tx cases. The final seven studies, referred to as position-error cases, which had a large discordance but no misalignment, were found to have deviations of 4.6 and 3.6 mm in D{sub AP} and D{sub SI}, respectively. The position-error cases correspond to a large discrepancy on the relative location between the centroid and pelvic bones seen in post-Tx CT and recorded x-ray radiographs. Conclusions: Systematic analyses of proton-activated positron emission distributions provide patient-specific information on prostate motion ({sigma}{sub M}) and patient position variability ({Sigma}{sub p}) during daily proton beam delivery. The less than 2 mm of displacement variations in the good cases indicates that population-based values of {Sigma}{sub p} and {sigma}{sub M} used in margin algorithms for treatment planning at the authors' institution are valid for the majority of cases. However, a small fraction of PET/CT studies (approximately 14%) with {approx}4 mm displacement variations may require different margins. Such data are useful in establishing patient-specific planning target volume margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Towards demonstration of electron cooling with bunched electron beam

All electron cooling systems which were in operation so far employed electron beam generated with an electrostatic electron gun in DC operating mode, immersed in a longitudinal magnetic field. At low energies magnetic field is also being used to transport electron beam through the cooling section from the gun to the collector. At higher energies (few MeV), it was shown that one can have simpler electron beam transport without continuous magnetic field. Because of a rather weak magnetic field on the cathode and in the cooling section the latter approach was referred to as 'non-magnetized cooling', since there was no suppression of the transverse angular spread of the electron beam with the magnetic field in the cooling section. Such a cooler successfully operated at FNAL (2005-11) at electron beam energy of 4.3 MeV. Providing cooling at even higher energies would be easier with RF acceleration of electron beam, and thus using bunched electron beam for cooling. Significant efforts were devoted to explore various aspects of such bunched electron beam cooling as part of R and D of high-energy electron cooling for RHIC. However, experimental studies of such cooling are still lacking. Establishing this technique experimentally would be extremely useful for future high-energy applications. Presently there is an ongoing effort to build Proof-of-Principle (PoP) experiment of Coherent Electron Cooling (CEC) at RHIC, which promises to be superior to conventional electron cooling for high energies. Since the CEC experiment is based on bunched electron beam and it has sections where electron beam co-propagates with the ion beam at the same velocity, it also provides a unique opportunity to explore experimentally conventional electron cooling but for the first time with a bunched electron beam. As a result, it allows us to explore techniques needed for the high-energy electron cooling such as 'painting' with a short electron beam and control of ion beam distribution under cooling which is essential if cooling is provided in a collider. The software needed for comparison with the experiments is already developed as part of the previous high-energy electron cooling studies for RHIC. Since electron beam will be non-magnetized and there will be no magnetic field in the cooling section it will be also a first demonstration of fully non-magnetized cooling. The purpose of these studies was to explore whether we would be able to observe conventional electron cooling with parameters expected in the CEC PoP experiment. Below we summarize requirements on electron beam and cooling section needed for such demonstration.

43 PARTICLE ACCELERATORS↗

Towards Demonstration of Electron Cooling with Bunched Electron Beam

All electron cooling systems which were in operation so far employed electron beam generated with an electrostatic electron gun in DC operating mode, immersed in a longitudinal magnetic field. At low energies magnetic field is also being used to transport electron beam through the cooling section from the gun to the collector. At higher energies (few MeV), it was shown that one can have simpler electron beam transport without continuous magnetic field. Because of a rather weak magnetic field on the cathode and in the cooling section the latter approach was referred to as “non-magnetized cooling”, since there was no suppression of the transverse angular spread of the electron beam with the magnetic field in the cooling section. Such a cooler successfully operated at FNAL (2005-11) at electron beam energy of 4.3 MeV. Providing cooling at even higher energies would be easier with RF acceleration of electron beam, and thus using bunched electron beam for cooling. Significant efforts were devoted to explore various aspects of such bunched electron beam cooling as part of R&D of high-energy electron cooling for RHIC. However, experimental studies of such cooling are still lacking. Establishing this technique experimentally would be extremely useful for future high-energy applications. Presently there is an ongoing effort to build Proof-of-Principle (PoP) experiment of Coherent Electron Cooling (CEC) at RHIC, which promises to be superior to conventional electron cooling for high energies. Since the CEC experiment is based on bunched electron beam and it has sections where electron beam co-propagates with the ion beam at the same velocity, it also provides a unique opportunity to explore experimentally conventional electron cooling but for the first time with a bunched electron beam. As a result, it allows us to explore techniques needed for the high-energy electron cooling such as “painting” with a short electron beam and control of ion beam distribution under cooling which is essential if cooling is provided in a collider. The software needed for comparison with the experiments is already developed as part of the previous high-energy electron cooling studies for RHIC. Since electron beam will be non-magnetized and there will be no magnetic field in the cooling section it will be also a first demonstration of fully non-magnetized cooling. The purpose of these studies was to explore whether we would be able to observe conventional electron cooling with parameters expected in the CEC PoP experiment. Below we summarize requirements on electron beam and cooling section needed for such demonstration.

43 PARTICLE ACCELERATORS↗

SU-F-BRD-09: A Random Walk Model Algorithm for Proton Dose Calculation

Purpose: To develop a random walk model algorithm for calculating proton dose with balanced computation burden and accuracy. Methods: Random walk (RW) model is sometimes referred to as a density Monte Carlo (MC) simulation. In MC proton dose calculation, the use of Gaussian angular distribution of protons due to multiple Coulomb scatter (MCS) is convenient, but in RW the use of Gaussian angular distribution requires an extremely large computation and memory. Thus, our RW model adopts spatial distribution from the angular one to accelerate the computation and to decrease the memory usage. From the physics and comparison with the MC simulations, we have determined and analytically expressed those critical variables affecting the dose accuracy in our RW model. Results: Besides those variables such as MCS, stopping power, energy spectrum after energy absorption etc., which have been extensively discussed in literature, the following variables were found to be critical in our RW model: (1) inverse squared law that can significantly reduce the computation burden and memory, (2) non-Gaussian spatial distribution after MCS, and (3) the mean direction of scatters at each voxel. In comparison to MC results, taken as reference, for a water phantom irradiated by mono-energetic proton beams from 75 MeV to 221.28 MeV, the gamma test pass rate was 100% for the 2%/2mm/10% criterion. For a highly heterogeneous phantom consisting of water embedded by a 10 cm cortical bone and a 10 cm lung in the Bragg peak region of the proton beam, the gamma test pass rate was greater than 98% for the 3%/3mm/10% criterion. Conclusion: We have determined key variables in our RW model for proton dose calculation. Compared with commercial pencil beam algorithms, our RW model much improves the dose accuracy in heterogeneous regions, and is about 10 times faster than MC simulations.

60 APPLIED LIFE SCIENCES↗

Influence of sun zenith angle on canopy clumping and the resulting impacts on photosynthesis

Addressing the impact of vegetation architecture on shortwave radiation transfer in land surface models is important for accurate weather forecasting, carbon budget estimates, and climate predictions. This paper investigates to what extent it is possible to retrieve structural parameters of two different parameterization schemes from direct transmittance derived from digital hemispherical photography and 3D radiative transfer modeling for two study sites with different vegetation canopy architectures. Neglecting the representation of 3D canopy structure in radiative transfer schemes leads to significant errors in shortwave radiation partitioning (up to 3.5 times more direct transmittance in the 3D model). Structural parameters, referred to as whole canopy ‘clumping indices’, were obtained in order to evaluate the impact of angular variation in clumping on shortwave radiation transfer. Impacts on photosynthesis were evaluated at site level with the UKESM land surface model, JULES. A comparison between flux tower derived and modeled photosynthesis indicates that considering zenith angular variations of structural parameters in the radiative transfer scheme of the UKESM land surface model significantly improves photosynthesis prediction in light limited ecosystems (from RMSE = 2.91 μmol CO 2 .m -2 .s -1 to RMSE = 1.51 μmol CO 2 .m -2 .s -1 , 48% smaller), typically with enhanced photosynthesis from bottom layers.

54 ENVIRONMENTAL SCIENCES↗

Study of the electronic and rovibronic structure of the X {sup 2}Σ{sup +}, A {sup 2}Π, and B {sup 2}Σ{sup +} states of AlO

The electronic structure of the X {sup 2}Σ{sup +}, A {sup 2}Π, and B {sup 2}Σ{sup +} states of aluminum monoxide (AlO) are studied via ab initio multi-reference configuration interaction calculations. Core correlation corrections, several basis sets, and active space choices are considered. Angular momentum and spin-orbit coupling terms are obtained at different levels of theory. The resulting ab initio curves are used to solve the associated rovibronic problem for the total angular momentum J up to 112.5 and then also refined by fitting to the experimental wavenumbers available in the literature, reproducing them with the root-mean-square error of 0.07 cm{sup −1}. Theoretical rovibronic energy levels of AlO in its X {sup 2}Σ{sup +}, A {sup 2}Π, and B {sup 2}Σ{sup +} electronic states are presented including those from the X − B blue-green system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Note: A simple method to suppress the artificial noise for velocity map imaging spectroscopy

A simple method has been proposed to suppress artificial noise from the counts with respect to the central line (or point) for the reconstructed 3D images with cylindrical symmetry in the velocity-map imaging spectroscopy. A raw 2D projection around the z-axis (usually referred to as central line) for photodetachment, photoionization, or photodissociation experiments is pre-processed via angular tailored method to avoid the signal counts distributed near the central line (or point). Two types of photoelectron velocity-map imaging (O{sup −} and Au{sup −} ⋅ NH{sub 3}) are demonstrated to give rise to the 3D images with significantly reduced central line noise after pre-processing operation. The major advantages of the pre-operation are the ability of suppression of central-line noise to resolve weak structures or vibrational excitation in atoms or molecules near photon threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A fiber-coupled displacement measuring interferometer for determination of the posture of a reflective surface

A fiber-coupled displacement measuring interferometer capable of determining of the posture of a reflective surface of a measuring mirror is proposed. The newly constructed instrument combines fiber-coupled displacement and angular measurement technologies. The proposed interferometer has advantages of both the fiber-coupled and the spatially beam-separated interferometer. A portable dual-position sensitive detector (PSD)-based unit within this proposed interferometer measures the parallelism of the two source beams to guide the fiber-coupling adjustment. The portable dual PSD-based unit measures not only the pitch and yaw of the retro-reflector but also measures the posture of the reflective surface. The experimental results of displacement calibration show that the deviations between the proposed interferometer and a reference one, Agilent 5530, at two different common beam directions are both less than ±35 nm, thus verifying the effectiveness of the beam parallelism measurement. The experimental results of angular calibration show that deviations of pitch and yaw with the auto-collimator (as a reference) are less than ±2 arc sec, thus proving the proposed interferometer’s effectiveness for determination of the posture of a reflective surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

C5 Benchmark Problem with Discrete Ordinate Radiation Transport Code DENOVO

The C5 benchmark problem proposed by the Organisation for Economic Co-operation and Development/Nuclear Energy Agency was modeled to examine the capabilities of Denovo, a three-dimensional (3-D) parallel discrete ordinates (S{sub N}) radiation transport code, for problems with no spatial homogenization. Denovo uses state-of-the-art numerical methods to obtain accurate solutions to the Boltzmann transport equation. Problems were run in parallel on Jaguar, a high-performance supercomputer located at Oak Ridge National Laboratory. Both the two-dimensional (2-D) and 3-D configurations were analyzed, and the results were compared with the reference MCNP Monte Carlo calculations. For an additional comparison, SCALE/KENO-V.a Monte Carlo solutions were also included. In addition, a sensitivity analysis was performed for the optimal angular quadrature and mesh resolution for both the 2-D and 3-D infinite lattices of UO{sub 2} fuel pin cells. Denovo was verified with the C5 problem. The effective multiplication factors, pin powers, and assembly powers were found to be in good agreement with the reference MCNP and SCALE/KENO-V.a Monte Carlo calculations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Data for "Plasmon-driven exciton formation in a non-equilibrium Fermi liquid"

This repository contains source data for key plots presented in the manuscript "Plasmon-driven exciton formation in a non-equilibrium Fermi liquid." Experimental data that was analyzed in Igor Pro 8 are presented as the .pxp files used to generate individual sub-plots. Electronic spectral function calculations are provided as .txt files, in which consecutive rows refer to the meshgrid x coordinate, y coordinate, spectral function (and, where relevant, axis-projected local angular momentum). We additionally include the Wannier model and DFT-obtained bulk band structure on which the Wannier model was based. Files are named as the number of the figure in the manuscript to which they correspond, with additional details included where necessary. Details of file names: 2a_DOS_Lxz_Ek_KGM_40layer_xnum_800kpt_tot.txt: Density of states, xz-axis projected local orbital angular momentum, for 800 points along the K-Gamma-M path, for a 40-layer model. 2c_composite_y.pxp: ARPES (angle-resolved photoemission spectroscopy) spectra along the ky axis, including both a scan near the Fermi level and a scan at high kinetic energies. 2d_LCP_RCP_diff_Sect_20K.pxp: difference between ARPES constant energy cuts at T=20 K at E0 + 0.23 eV taken with left- and right-circularly polarized photons. The polarization-integrated intensity at the constant energy cut is also included. 2e_DOS_L45_E11pt79_m0pt25to0pt25_xnum_800kpt_tot.txt: Density of states, xz-projected local orbital angular momentum, and corresponding k-points in two dimensions from ab-initio electronic structure calculations for a constant-energy cut. 3a_[x]_[y]ps: ARPES cut under excitation at a fluence of x uJ/cm2, measured y ps after photoexcitation. Measurements were performed at 9 K. 3b_[x]: Energy distribution curves under excitation at a fluence x uJ/cm2 at selected delay times after photoexcitation. 4a_ImSigma_vs_temperature.pxp: Imaginary self energy (extracted from ARPES linewidths) at different energies above E0 for selected lattice temperatures. 4b_EELS_lowE.pxp: Electron energy loss spectrum over a low energy range 5b_diff_55m15.pxp: Difference between momentum-integrated Tr-ARPES traces at 55 uJ/cm2 and 15 uJ/cm2 photoexcitation. Time-dependent intensity at each energy level has been normalized to a maximum of 1 for each individual fluence prior to subtraction. 5d_invtau_at_EX_vs_fluence.pxp: decay rate at a specified energy EX for different excitation fluences, from single exponential fits. NOTE: Analyses based on the Wannier model presented here should cite both the associated Article and this dataset. For all other files in the repository, citing the dataset alone is sufficient.

Acharya, Rishi [University of Illinois] (ORCID:000↗

A high precision instrument to measure angular and binocular deviation introduced by aircraft windscreens by using a shadow casting technique

Objects viewed through transparent sheets with residual non-parallelism and irregularity appear shifted and distorted. This distortion is measured in terms of angular and binocular deviation of an object viewed through the transparent sheet. The angular and binocular deviations introduced are particularly important in the context of aircraft windscreens and canopies as they can interfere with decision making of pilots especially while landing, leading to accidents. In this work, we have developed an instrument to measure both the angular and binocular deviations introduced by transparent sheets. This instrument is especially useful in the qualification of aircraft windscreens and canopies. It measures the deviation in the geometrical shadow cast by a periodic dot pattern trans-illuminated by the distorted light beam from the transparent test specimen compared to the reference pattern. Accurate quantification of the shift in the pattern is obtained by cross-correlating the reference shadow pattern with the specimen shadow pattern and measuring the location of the correlation peak. The developed instrument is handy to use and computes both angular and binocular deviation with an accuracy of less than {+-}0.1 mrad ( Almost-Equal-To 0.036 mrad) and has an excellent repeatability with an error of less than 2%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Union of rotational and vibrational modes in generator-coordinate-type calculations, with application to neutrinoless double-β decay

Good many-body methods for medium and heavy nuclei are important. Here we combine rotational motion with vibrational modes in a novel generator-coordinate method (GCM): starting from a mean-field solution (Hartree-Fock-Bogoliubov), we create nonorthogonal reference states from low-lying quasiparticle Tamm-Dancoff modes, and then project onto states of good angular momentum and particle number. Here, the results we benchmark against full shell model calculations. Even with just a few such modes we find improvement over standard GCM calculations in excitation spectra. We also find significant improvement in 0νββ nuclear matrix elements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CLOSE STELLAR BINARY SYSTEMS BY GRAZING ENVELOPE EVOLUTION

I suggest a spiral-in process in which a stellar companion grazes the envelope of a giant star while both the orbital separation and the giant radius shrink simultaneously, forming a close binary system. The binary system might be viewed as evolving in a constant state of 'just entering a common envelope (CE) phase.' In cases where this process takes place, it can be an alternative to CE evolution where the secondary star is immersed in the giant's envelope. Grazing envelope evolution (GEE) is made possible only if the companion manages to accrete mass at a high rate and launches jets that remove the outskirts of the giant envelope, hence preventing the formation of a CE. The high accretion rate is made possible by the accretion disk launching jets which efficiently carry the excess angular momentum and energy from the accreted mass. The orbital decay itself is caused by the gravitational interaction of the secondary star with the envelope inward of its orbit, i.e., dynamical friction (gravitational tide). Mass loss through the second Lagrangian point can carry additional angular momentum and envelope mass. The GEE lasts for tens to hundreds of years. The high accretion rate, with peaks lasting from months to years, might lead to a bright object referred to as the intermediate luminosity optical transient (Red Novae; Red Transients). A bipolar nebula and/or equatorial ring are formed around the binary remnant.

79 ASTRONOMY AND ASTROPHYSICS↗

On the evolution of vortex rings with swirl

A laminar vortex ring with swirl, which has the meridional velocity component inside the vortex core, was experimentally generated by the brief fluid ejection from a rotating outlet. The evolution of the vortex ring was investigated with flow visualizations and particle image velocimetry measurements in order to find the influence of swirling flow in particular upon the transition to turbulence. Immediately after the formation of a vortex ring with swirl, a columnar strong vortex along the symmetric axis is observed in all cases of the present experiment. Then the characteristic fluid discharging from a vortex ring with swirl referred to as “peeling off” appears. The amount of discharging fluid due to the “peeling off” increases with the angular velocity of the rotating outlet. We conjectured that the mechanism generating the “peeling off” is related to the columnar strong vortex by close observations of the spatio-temporal development of the vorticity distribution and the cutting 3D images constructed from the successive cross sections of a vortex ring. While a laminar vortex ring without swirl may develop azimuthal waves around its circumference at some later time and the ring structure subsequently breaks, the swirling flow in a vortex ring core reduces the amplification rate of the azimuthal wavy deformation and preserved its ring structure. Then the traveling distance of a vortex ring can be extended using the swirl flow under certain conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: An X-ray powder diffractometer with a wide scattering-angle range of 72° using asymmetrically positioned one-dimensional detectors

An X-ray powder diffractometer has been developed for a time-resolved measurement without the requirement of a scattering angle (2θ) scan. Six one-dimensional detector modules are asymmetrically arranged in a vertical line at a designed distance of 286.5 mm. A detector module actually covers a diffraction angle of about 12° with an angular resolution of 0.01°. A diffracted intensity pattern is simultaneously recorded in a 2θ angular range from 1.63° to 74.37° in a “one shot” measurement. We tested the performance of the diffractometer with reference CeO{sub 2} powders and demonstrated diffraction measurements from an operating lithium-air battery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SUBMILLIMETER ARRAY AND SPITZER OBSERVATIONS OF BOK GLOBULE CB 17: A CANDIDATE FIRST HYDROSTATIC CORE?

We present high angular resolution Submillimeter Array (SMA) and Spitzer observations toward the Bok globule CB 17. SMA 1.3 mm dust continuum images reveal within CB 17 two sources with an angular separation of {approx}21'' ({approx}5250 AU at a distance of {approx}250 pc). The northwestern continuum source, referred to as CB 17 IRS, dominates the infrared emission in the Spitzer images, drives a bipolar outflow extending in the northwest-southeast direction, and is classified as a low-luminosity Class 0/I transition object (L{sub bol} {approx} 0.5 L{sub Sun }). The southeastern continuum source, referred to as CB 17 MMS, has faint dust continuum emission in the SMA 1.3 mm observations ({approx}6{sigma} detection; {approx}3.8 mJy), but is not detected in the deep Spitzer infrared images at wavelengths from 3.6 to 70 {mu}m. Its bolometric luminosity and temperature, estimated from its spectral energy distribution, are {<=}0.04 L{sub Sun} and {<=}16 K, respectively. The SMA CO (2-1) observations suggest that CB 17 MMS may drive a low-velocity molecular outflow ({approx}2.5 km s{sup -1}), extending in the east-west direction. Comparisons with prestellar cores and Class 0 protostars suggest that CB 17 MMS is more evolved than prestellar cores but less evolved than Class 0 protostars. The observed characteristics of CB 17 MMS are consistent with the theoretical predictions from radiative/magnetohydrodynamical simulations of a first hydrostatic core, but there is also the possibility that CB 17 MMS is an extremely low luminosity protostar deeply embedded in an edge-on circumstellar disk. Further observations are needed to study the properties of CB 17 MMS and to address more precisely its evolutionary stage.

79 ASTRONOMY AND ASTROPHYSICS↗

Explicit simulation of the Brownian rotation of arbitrary shaped aerosol particles using quaternions

The shape of an aerosol particle strongly influences its mass and momentum transfer cross-sections, charging properties, and other physical properties. Here, we present an explicit time-stepping procedure to simulate the rotational Brownian motion of arbitrary shaped aerosol particles by solving Euler’s equation of rotation. A Langevin formulation of the rotation equations is used, wherein Brownian motion due to thermal collisions between a particle and background gas molecules is represented using a stochastic fluctuating torque and fluid resistance is included as a drag torque. To avoid singularities associated with describing the orientation of a shape with Euler angles, we employ a quaternion formulation that leads to first-order stochastic differential equations to describe the evolution of the angular position and angular velocity of a rigid body. We perform all the rotational dynamics calculations in the body-fixed frame of reference attached to the rotating shape whose basis vectors are the normalized eigenvectors of the inertia tensor of the particle. Numerical solutions to rotation under torque-free conditions, damped rotation without Brownian motion, and stochastic rotation for arbitrary shapes are presented and discussed. The presented method enables time-resolved simulation of Brownian rotation for direct comparison with experimentally measured trajectories or statistical measures. The second order accuracy of the used time-stepping procedure places a severe restriction on the timestep that can be used for obtaining accurate results. Animations of presented simulations are included for visualizing rotational motion at various gas pressures. To aid implementation, MATLAB ® codes are also provided. Extension to include translation Brownian motion is straightforward.

Roy, Mrittika↗