Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Analytical sensitivity analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Application of trichloroacetimidate-mediated benzylation to the detection of pinacolyl methylphosphonic acid in standardised proficiency test matrices

Here, a procedure for the qualitative analysis of pinacolyl methylphosphonic acid (PMPA), a degradation product from the nerve agent Soman (GD), is presented. The protocol involves the derivatization of PMPA with benzyl trichloroacetimidate resulting in its benzylation under neutral conditions, a desirable attribute in the presence of other base-sensitive analytes. The method was found to perform well in the detection of this Schedule 2 chemical, spiked at low concentrations, in three different test matrices, two soils and one liquid, featured in different Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency tests.

Chemistry↗

On the dual advantage of placing observations through forward sensitivity analysis

The four-dimensional variational data assimilation methodology for assimilating noisy observations into a deterministic model has been the workhorse in forecasting centres for over three decades. While this method provides a computationally efficient framework for dynamic data assimilation, it is largely silent on the important question concerning the minimum number and placement of observations. To answer this question, we demonstrate the dual advantage of placing the observations where the square of the sensitivity of the model solution with respect to the unknown control variables, called forward sensitivities, attains its maximum. By following this approach, we can force the observability Gramian to be of full rank, which in turn guarantees efficient recovery of the optimal values of the control variables, which is the first of the two advantages of this strategy. We further show that the proposed strategy of placing observations has another inherent optimality: the square of the sensitivity of the optimal estimates of the control with respect to the observations (used to obtain these estimates) attains its minimum value, a second advantage that is a direct consequence of the above strategy for placing observations. Our analytical framework and numerical experiments on linear and nonlinear systems confirm the effectiveness of our proposed strategy.

97 MATHEMATICS AND COMPUTING↗

LX-17 Thermal Decomposition-Characterization of Solid Residues from Cook-Off in a Small-Scale Vessel Under Confinement

Concerns surround whether insensitive (or any) energetic materials are more dangerous to handle when exposed to abnormal thermal environments. This study characterizes the residual material remaining after LX-17 (92.5 % 1,3,5-triamino 2,4,6-trinitro benzene (TATB) and 7.5 % Kel-F) is exposed to various thermal environments in a sealed small-scale vessel cook-off test reactor (heated at 0.1 to 100 °C/min until the reactor opened at 3000 psi (20.7 MPa)). Previous work has shown no additional sensitivity of these residues as evaluated by small-scale safety analysis, but characterization on the molecular scale indicates the TATB is transformed to more reactive compounds as well as the residue could be precursors to toxic gases. The solids and chars were characterized by various analytical methods. Heat-flow measurements indicated exothermic release is due to a mixture of residual TATB and related decomposition products (which may be more energetic). The N/C and O/N ratios indicated a material much more degraded than TATB. Primarily, the solids were a network of amorphous C inter-dispersed with N and O. Types of bonding include C–C, C–N, N–H, N–C, N=C, N≡C, C–O=, and –OH. Solvent extracts of the solids showed TATB decomposition intermediates benzo-furazans and benzo-furoxans, substituted TATB (mono-nitroso, hydroxyl, and chlorinated) along with several unidentified smaller molecules. These results indicate thermal treatment produces an amorphous carbon residue with heteroatoms incorporated through differing functionality, varying depending upon the thermal severity of exposure. These structures also could further decompose producing toxic light gases (such as cyanide).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analytical comparisons of handheld LIBS and XRF devices for rapid quantification of gallium in a plutonium surrogate matrix

This work compares a portable laser-induced breakdown spectroscopy (LIBS) analyzer to a portable X-ray fluorescence (XRF) device for quantification of gallium (Ga) in a plutonium surrogate matrix of cerium (Ce) for the first time. Calibration methods are developed with spectra of Ce–Ga samples from both devices. Here, metrics such as limit of detection (LoD) and mean average percent error (MAPE) are examined to evaluate calibration performance. While the portable LIBS device can yield a nearly instantaneous analytical measurement, its accuracy is hampered by self-absorption. By employing a self-absorption correction and increasing gating delay, LIBS calibrations with errors in the low single percents and LoDs of 0.1% Ga were constructed. The XRF device produces calibrations with superlative sensitivity, yielding LoDs for gallium in the low tens of parts-per-million (ppm), two orders of magnitude lower than the corrected LIBS models. However, a clear trade-off of measurement fidelity is established between the instantaneous analysis of the LIBS device and the minutes-long XRF measurement yielding superior detection limits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Frictionless knowledge injection for few-shot learning

Cutting-edge machine learning methods often require large volumes of curated training data, precluding their use in national security problems with rare events in massive datasets. We present a method for incorporating abstract knowledge into models tailored for sparse data. A subject matter expert defines salient concepts using data examples, which are encoded in the model’s embedding space. Models are then trained to respect these concepts. This method enables knowledge injection, yielding effective models with limited labeled data and the ability to assess model sensitivity for subject matter expertise across the nonproliferation mission space, as demonstrated with Raman spectra analysis.

Stomps, Jordan [ORNL] (ORCID:0000000178114479)↗

Developing Frequency Stability Constraint for Unit Commitment Problem Considering High Penetration of Renewables

As zero-carbon electricity systems become the trend of future grid, the system inertia provided by conventional synchronous generators (SGs) keeps decreasing. The resultant lower system inertia will inevitably cause frequency stability problem, especially in the first few seconds following disturbance. To tackle this challenge, this paper proposes a frequency stability constraint for power systems unit commitment problem by considering the fast frequency responses (FFRs) from inverter-based resources (IBRs). Our developed frequency stability constraint is grounded on an analytical frequency nadir estimation framework that considers both SG and IBR dynamics. The accuracy of our frequency nadir estimation framework is validated by most severe N-1 contingency simulation result in a real island system. Then, the adaptive inertia frequency stability constraint is derived by performing sensitivity analysis with our frequency nadir estimation framework. Finally, we demonstrate the effectiveness of our developed frequency stability constraint with one year day-ahead unit commitment results of the island system.

fast frequency response↗

A Privacy First Path Analysis using Clickstream Data

In the modern digital economy, data-driven decision making is crucial for effectively meeting the ever-evolving demands of consumer engagement and satisfaction. Clickstream data has become invaluable for understanding customer behavior, yet concerns over privacy and security persist, especially with some internet service providers profiting from its sale. This article introduces an innovative methodology that blends experiential learning with advanced cryptographic techniques, including differential privacy and graph analytics. The core objective of this methodology is to estimate Customer Lifetime Value (CLV) by analyzing clickstream data, achieving an average prediction accuracy of 92.4% in user engagement levels while ensuring user anonymity through Recency, Frequency, and Monetary (RFM) analysis. Our study introduces the concept of a “data depositor” and a privacy manager, employing the composition theorem to merge non-adaptive queries effectively. Privacy budgets (? = 1.0, d = 10-5), sensitivity-specific techniques, and data partitioning were applied. Randomization and noise addition protect data integrity, with special handling for categorical values. This approach, differing from prior studies, offers a 12.6% improvement in privacy-preserving targeting accuracy while maintaining strict confidentiality, presenting a novel path forward in data-driven decision-making.

Frequency and Monetary (RFM) analysis↗

The DESI-Lensing Mock Challenge: large-scale cosmological analysis of 3x2-pt statistics

The current generation of large galaxy surveys will test the cosmological model by combining multiple types of observational probes. Realising the statistical promise of these new datasets requires rigorous attention to all aspects of analysis including cosmological measurements, modelling, covariance and parameter likelihood. In this paper we present the results of an end-to-end simulation study designed to test the analysis pipeline for the combination of the Dark Energy Spectroscopic Instrument (DESI) Year 1 galaxy redshift dataset and separate weak gravitational lensing information from the Kilo-Degree Survey, Dark Energy Survey and Hyper-Suprime-Cam Survey. Our analysis employs the 3x2-pt correlation functions including cosmic shear and galaxy-galaxy lensing, together with the projected correlation function of the spectroscopic DESI lenses. We build realistic simulations of these datasets including galaxy halo occupation distributions, photometric redshift errors, weights, multiplicative shear calibration biases and magnification. We calculate the analytical covariance of these correlation functions including the Gaussian, noise and super-sample contributions, and show that our covariance determination agrees with estimates based on the ensemble of simulations. We use a Bayesian inference platform to demonstrate that we can recover the fiducial cosmological parameters of the simulation within the statistical error margin of the experiment, investigating the sensitivity to scale cuts. This study is the first in a sequence of papers in which we present and validate the large-scale 3x2-pt cosmological analysis of DESI-Y1.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluating Optical Techniques to Characterize Solid State Samples for the Pu-238 Supply Program

This report documents steps that have been taken to establish advanced characterization capabilities for solid-state samples to support the 238 Pu Supply Program. The program has already invested significantly in spectroscopy and online monitoring development for liquid processes. Many of the data, analytical methods, and equipment could also be leveraged for the analysis of Np/Pu oxides and Np pellets to help classify material properties and link them to operations. The techniques described in this work include diffuse reflectance spectroscopy (DRS), Raman spectroscopy, and laser-induced breakdown spectroscopy (LIBS). Each technique is sensitive to various chemical and/or elemental species and can provide complimentary information to more standard methods such as powder x-ray diffraction and scanning electron microscopy. These options are remotely deployable via fiber-optic cables. DRS and Raman spectroscopy are already approved for glove box and hot cell work, but LIBS requires US Department of Energy approval for incorporation. Raman spectroscopy does require laser shielding, which means that DRS is the easiest method to implement. However, each technique provides complimentary data, and the most robust sample characterization could be achieved when all three, among other methods, are harnessed together. This report documents some of the progress made testing these capabilities, some of the challenges, and next steps to optimize the technology and integration strategies.

07 ISOTOPE AND RADIATION SOURCES↗

Model Package Report: Composite Analysis Solid Waste Release Model (CASWR Model)

This document describes the implementation of a solid waste form release model in GoldSim for the Hanford Site Composite Analysis (CA) Update. This Composite Analysis Solid Waste Release model (CASWR model) was designed to generate deterministic radionuclide release rates for Hanford’s Central Plateau solid waste disposal sites using single realizations of release model coefficients. Five generalized waste form types are used for the conceptual model of waste release: surplus reactor block, cement, soil-debris, grouted residual waste, and ancillary equipment. The surplus reactor block waste form consists of radionuclide leaching from surplus production graphite reactor core blocks via unspecified processes (White et al., 1984 as cited in PNNL-15965). The cement waste form represents solidified wastes whose permeability is much lower than that of the surrounding soil. The soil-debris waste form type is defined as unconsolidated waste mixed with soil material. Tanks and canyon complexes comprise the grouted residual waste form such that their solid waste will be grouted and capped with a surface barrier at the completion of their cleanup. Finally, the ancillary equipment waste form constitutes contaminant releases from ancillary and auxiliary waste form residues associated with tank farms at closure. Individual sub-models are implemented to numerically represent a respective waste form within the CASWR Model: Surplus Reactor Block Sub-model, Cement Sub-model, SoilDebris Sub-model, Grouted Residual Waste Sub-model, and Ancillary Equipment Submodel. Advection is assumed to be the primary transport process governing the release of radionuclides in the Ancillary Equipment and Soil-Debris Sub-models. Diffusion is assumed to be the primary release process in the Grouted Residual Waste and Cement Sub-models. An unspecified zero-order release process is considered in the Surplus Reactor Block Sub-model due to the lack of information regarding actual processes involved in irradiated graphite leaching. The Surplus Reactor Block, Cement, and SoilDebris Sub-models were compared against analytical solutions (PNNL-11800, Composite Analysis for Low-Level Waste Disposal in the 200 Area Plateau of the Hanford Site). The agreement between results of these analytical solutions and the corresponding waste form models verified their correct implementation in GoldSim. A 1-D modeling abstraction approach for the Grouted Residual Waste and Ancillary Equipment Sub-models was adopted from existing Performance Assessment (PA) models. Despite the simplifications made in these sub-models, they were found to be appropriate representations of the waste forms, similar to what was used in the Waste Management Area C PA model (RPP-ENV-58782, Performance Assessment of Waste Management Area C, Hanford Site, Washington, Rev. 0). A sensitivity analysis was conducted to identify the most influential parameters in each waste form sub-model. Suggestions for considering pH-dependent and redox-dependent release mechanisms are formulated through the development of a conditional constant approach in GoldSim.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulation process and data flow for a large system dynamics model

This paper documents the workflow and supporting technologies that a large system dynamics model, the biomass scenario model, employs to streamline the data preparation, simulation, quality control, and analysis process at the National Renewable Energy Laboratory. The workflow centers on automation of routine aspects of the flow of data between data stores, simulations, and visualizations. It enforces quality checks on data, reproducibility of computations, and traceability of results, while maintaining complete archives of modeling and analysis artifacts. The resulting frictionless simulation/analysis environment supports large-scale sensitivity analysis, interactive creation of ensembles of simulations, and rapid visualization-based exploration of simulation results.

09 BIOMASS FUELS↗

Single molecule insights into interfacial molecular recognition for model electrochemical DNA biosensors

Electrochemical sensors that use surface-immobilized DNA to bind analytes and transduce the binding into electrochemical signals, have the potential for rapid, specific, and sensitive detection of bioanalytes via a compact and portable platform. However, accessing the structure of these surfaces/interfaces at the relevant spatial scale (< 10 nm), which determines the interfacial interactions and ultimately sensing performance, remains an unsolved challenge. Here, we review studies that have used high resolution atomic force microscope imaging and spatial statistical analysis tools to understand crowding interactions between thiolated DNA probes immobilized on gold electrodes and how such interactions impact target binding. We also review related studies that attempt to control the nanoscale spatial arrangement of the immobilized recognition elements to optimize sensing performance. Furthermore, these efforts have led to new advances in understanding of the structure-function relationships of DNA-based electrochemical biosensors to move the field toward rational engineering of these biosensing interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Glycolate Analysis in Tank 22: Developing and Testing Analytical Methods for the Savannah River Site Liquid Waste System

Researchers developed and tested a range of techniques to support a low mg/L Limit of Quantitation (LOQ) of glycolate in radioactive Tank 22 waste solution by Ion Chromatography (IC) and by proton NMR. For the IC method, Dionex OnGuard II cartridges were tested as a means of removing alkali earth and transition metals that can interfere during ion chromatography applications especially when analyzing for low-concentration, chelating analytes. Additionally, concentrations of nitrate in the raw Tank 22 sample (5,000 to 10,000 mg/L) were managed by using reasonable levels of sample dilution. The resulting IC performance quality was enhanced by improving the baseline, increasing sensitivity [Limit of Quantitation (LOQ) of 12 mg/L and Limit of Detection (LOD) of 4.0 mg/L], and resolving analytes into well-defined Gaussian peaks when using the Dionex OnGuard II H⁺ cartridges to remove matrix interferences. High concentrations of nitrate limited the performance of the IC method. To achieve an acceptable baseline, samples with high nitrate content require more dilution, resulting in higher detection limits. Tests on samples with higher concentrations of nitrate (Tank 30 and 32 supernate with approximately 150000 mg/L nitrate) suggested that IC detection limits for glycolate in these samples would be > 500 mg/L. Thus, an LOQ of 12 mg/L is not feasible by this IC method on evaporator feed samples. An alternative method of glycolate analysis, using proton nuclear magnetic resonance (H NMR), was developed by the research team. In initial tests, the H NMR technique provided reasonable quantitation of glycolate in Tank 22 conditions by direct observation of the liquid. The H NMR method may provide improved detection limits for solutions with higher nitrate concentrations. We recommend further development of this analysis for high nitrate LWS samples such as evaporator feed and evaporator drop tank content. A method for pretreatment of samples using crystalline silicotitanate (CST) was developed and tested. The objective of the pretreatment was to facilitate analysis of samples with higher levels of radioactivity. The pretreatment did not influence the glycolate concentration in solution, and the pretreatment is projected to reduce Cs 137 activity in a sample by a factor of 16,200. The double strike CST pretreatment was demonstrated and would allow milliliters of higher activity samples to be transferred from the Shielded Cells and handled in a containment unit for glycolate analysis. The various studies validated IC and H NMR methods for glycolate analysis, defined the range of applicability, and demonstrated key supporting analytical protocols. Based on the results, high quality glycolate analysis of Tank 22 is feasible down to approximately 12 mg/L, with the potential for broader applicability of the methods to other conditions in the Savannah River Site Liquid Waste System (LWS).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In situ liquid SIMS analysis of uranium oxide

Trace analysis of nuclear materials in solid particles collected in the environment or particles in liquid slurry generated in nuclear material manufacturing processes can pinpoint elemental, organic, and isotopic signatures of nuclear fuel cycle activities and processes. Such information can support nuclear safeguards programs by increasing our ability to detect undeclared nuclear materials, routine activities for safeguarding at declared facilities, and illicit activities. However, trace radioactive material analysis in liquids and slurries is challenging using bulk approaches. For example, one drawback of sensitive analysis such as inductively coupled plasma mass spectrometry (ICP-MS) is that sample is consumed or destroyed as a result of the technical approach. We developed a vacuum compatible microfluidic interface to enable surface analysis of liquids and liquid-solid interactions using time-of-flight secondary ion mass spectrometry (ToF-SIMS). In this work, we illustrate initial results of liquid standards containing uranium using in situ liquid SIMS. Specifically a series of diluted uranium standards used for ICPMS analysis were studied and the limit of detection was estimated. Since the liquid SIMS analysis is almost nondestructive, the same sample can be analyzed by other more destructive approaches afterwards or saved for future references. Consequently, multimodal analysis is possible. Our results demonstrate that in situ liquid SIMS can be used as a new approach to analyze radioactive materials in liquid and slurry forms of relevance to the IAEA safeguards missions.

In situ liquid ToF-SIMS, uranium, limit of detecti↗

Single Quadrupole Multiple Fragment Ion Monitoring Quantitative Mass Spectrometry

Single quadrupole mass spectrometry (MS) with enhanced in-source multiple fragment ion monitoring was designed to perform high sensitivity quantitative mass analyses. Enhanced in-source fragmentation amplifies fragmentation from traditional soft electrospray ionization producing fragment ions that have been found to be identical to those generated in tandem MS. We have combined enhanced in-source fragmentation data with criteria established by the European Union Commission Directive 2002/657/EC for electron ionization single quadrupole quantitative analysis to perform quantitative analyses. These experiments were performed on multiple types of complex samples that included a mixture of 50 standards, as well as cell and plasma extracts. The dynamic range for these quantitative analyses was comparable to triple quadrupole multiple reaction monitoring (MRM) analyses at up to 5 orders of magnitude with the cell and plasma extracts showing similar matrix effects across both platforms. Amino acid and fatty acid measurements performed from certified NIST 1950 plasma with isotopically labeled standards demonstrated accuracy in the range of 91–110% for the amino acids, 76–129% for the fatty acids, and good precision (coefficient of variation <10%). To enhance specificity, a newly developed correlated ion monitoring algorithm was designed to facilitate these analyses. This algorithm autonomously processes, aligns, filters, and compiles multiple ions within one chromatogram enabling both precursor and in-source fragment ions to be correlated within a single chromatogram, also enabling the detection of coeluting species based on precursor and fragment ion ratios. Single quadrupole instrumentation can provide MRM level quantitative performance by monitoring/correlating precursor and fragment ions facilitating high sensitivity analysis on existing single quadrupole instrumentation that are generally inexpensive, easy to operate, and technically less complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compound Specific Stable Isotope Signatures of Chemical Threat Agents: Incapacitants

In year 2 of this project (2017), our group focused on determining the causes of isotopic signatures in fentanyl. In order to better predict isotopic signatures in fentanyl, we analyzed the nitrogen isotope compositions of two key intermediates of fentanyl, NPP and ANPP. In addition, we analyzed additional fentanyl products produced using the Valdez route, along with five other alternative fentanyl routes. A new, more sensitive GC-C-IRMS method has been developed, which allows for compound specific isotope analysis of Chemical Attribution Signatures (CAS) in fentanyl.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Practical considerations for amino acid isotope analysis

Over the last few decades, isotopic analysis of amino acids at the compound- and position-specific levels has been rapidly advancing across diverse fields. As these techniques progress, evaluation of isotopic fractionation associated with sample workup is essential. This critical review of analytical methods through the lens of isotope geochemistry provides a benchmark for researchers across disciplines seeking to make compound- and position-specific amino acid isotope measurements. We focus on preparation, acid hydrolysis, clean-up, derivatization, separation, and C, H, N, and S isotope measurement. Despite substantial customizability across these steps, the following general recommendations should maximize recovery while minimizing isotopic fractionation. Samples should be freeze-dried and stored anoxically at ≤ –20 °C prior to conventional acid hydrolysis (6N HCl, 110 °C, 20–24 h, anoxic), which suffices for many residues. Both gas and liquid chromatographic (GC and LC, respectively) techniques are well-established and separate about 15 amino acids; LC bypasses the need for derivatization, while GC provides higher sensitivity. Furthermore, when derivatization is needed, n-acetyl and alkoxycarbonyl esters provide the most reproducible C isotope ratios. For compound-specific analyses, online GC–IRMS and LC–IRMS systems offer the easiest workflow, but EA–IRMS enables potential multi-element isotope analysis. Emerging techniques like high-resolution mass spectrometry are also promising for multi-element analysis and recover position-specific isotopic information. Looking forward to the next decade of innovation, isotope geochemists and ecologists can improve amino acid isotope analysis by focusing on streamlining multi-element analysis and standardizing calibration practices across laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validation Analysis of Medium-Scale Methanol Pool Fire Simulated in SIERRA/Fuego [Slides]

Analysis of methanol pool fire conducted as part of validation study for SIERRA/Fuego. Results showed trends & errors consistent with related studies. Area validation metric provides way to quantify model form uncertainty. AVM shows that more work could be done to understand how model form uncertainty varies with mesh resolution. There is a possible atypical use of MAVM on time-series data. AVM shows mismatch between predicted flame height and experimental value less sensitive to variations in mixture fraction than temperature. Mismatch about experimental value also more symmetric for mixture fraction. Our analysis showed that mixture fraction is preferable for this application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗