Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Air Safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Ceramic High Efficiency Particulate Air (HEPA) Filter Research and Development at Lawrence Livermore National Laboratory

Ceramic high efficiency particulate air (HEPA) filter development program began at Lawrence Livermore National Laboratory (LLNL) over 20 years ago. Historical incidents motivated current safety systems at nuclear facilities. A ceramic filter that can survive a fire can provide robust, passive safety protection. Research has been conducted to improve the safety of nuclear facilities and to reduce operational and lifecycle costs, through ceramic filter technology that can survive fire conditions. Here, the research focused on applications in both new facilities as well as meeting operational requirements necessary to retrofit filters into existing DOE facilities. The research has developed multiple filter technologies spanning traditional HEPA filter materials to advanced manufacturing technologies (e.g., electrospinning, additive manufacturing, etc.). This communication will present highlights of selected development efforts for ceramic HEPA filter research, current state-of-the-art for ceramic filters, and future needs including technical, regulatory, and commercial efforts.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nuclear Safety [Vol. 36, No. 2, July-December 1995]

Nuclear Safety is a journal that covers significant issues in the field of nuclear safety. Its primary scope is safety in the design, construction, operation, and decommissioning of nuclear power reactors worldwide and the research and analysis activities that promote this goal, but it also encompasses the safety aspects of the entire nuclear fuel cycle, including fuel fabrication, spent-fuel processing and handling, and nuclear waste disposal, the handling of fissionable materials and radioisotopes, and the environmental effects of all these activities. Table of Contents for this issue follows. THE CHORNOBYL ACCIDENT: 195 The Chornobyl Accident Revisited, Part III: Chernobyl Source Term Release Dynamics and Reconstruction of Events During the Active Phase, A. R. Sich; GENERAL SAFETY CONSIDERATIONS: 218 Second ANS Workshop on the Safety of Soviet-Designed Nuclear Power Plants, R. A. Bari; 234 Elements of a Nuclear Criticality Safety Program, C. M. Hopper; 243 Rickover, Excellence, and Criticality Safety Programs, R. E. Wilson; ACCIDENT ANALYSIS: 249 Transient Analysis of the PIUS Advanced Reactor Design with the TRAC-PF1/MOD2 Code, B. E. Boyack, J. L Steiner, S. C. Harmony, H. J. Stumpf, and J. F. Lime; 278 The Hierarchy-By-Interval Approach to Identifying Important Models that Need Improvement in Severe-Accident Simulation Codes, T. J. Heames, M. Khatib-Rahbar, J. E. Kelly, R. P. Jenks-Johnson, and Y.-S. Chen; 290 RELAP5/MOD3 Code Coupling Model, R. P. Martin; 299 Missiles Caused by Severe Pressurized-Water Reactor Accidents, R. Krieg; DESIGN FEATURES: 310 Validation of COMMIX with Westinghouse AP-600 PCCS Test Data, J. G. Sun, T. H. Chien, J. Ding, and W T. Sha; ENVIRONMENTAL EFFECTS: 321 Spent Nuclear Fuel Characterization for a Bounding Reference Assembly for the Receiving Basin for Off-Site Fuel, S. D. Kahook, R. L. Garrett, L. R. Canas, and M J. Beckum; OPERATING EXPERIENCES: 332 Reactor Shutdown Experience, Compiled by J. W. Cletcher; U.S. NUCLEAR REGULATORY COMMISSION INFORMATION AND ANALYSES: 335 Reactor Coolant System Blowdown at Wolf Creek on September 17, 1994, J. V. Kauffman and S. L. Israel; RECENT DEVELOPMENTS: 344 Reports, Standards, and Safety Guides, D. S. Oueener; 349 Proposed Rule Changes as of June 30, 1995; ANNOUNCEMENTS: 320 Symposium on Acceptability of Risk From Radiation—Application to Manned Space Flight; 320 24th DOE/NRC Nuclear Air Cleaning and Treatment Conference; 361 Radiation Biology and Radiation Protection— Modern Developments and Tendencies in Radiation Biology; 362 1997 IEEE Sixth Conference on Human Factors and Power Plants; 354 The Authors; 360 Reviewers of Nuclear Safety, Vol. 36.

05 NUCLEAR FUELS↗

Nuclear Safety [Vol. 36, No. 2, July-December 1995]

Nuclear Safety is a journal that covers significant issues in the field of nuclear safety. Its primary scope is safety in the design, construction, operation, and decommissioning of nuclear power reactors worldwide and the research and analysis activities that promote this goal, but it also encompasses the safety aspects of the entire nuclear fuel cycle, including fuel fabrication, spent-fuel processing and handling, and nuclear waste disposal, the handling of fissionable materials and radioisotopes, and the environmental effects of all these activities. Table of Contents for this issue follows. THE CHORNOBYL ACCIDENT: 195 The Chornobyl Accident Revisited, Part III: Chernobyl Source Term Release Dynamics and Reconstruction of Events During the Active Phase, A. R. Sich; GENERAL SAFETY CONSIDERATIONS: 218 Second ANS Workshop on the Safety of Soviet-Designed Nuclear Power Plants, R. A. Bari; 234 Elements of a Nuclear Criticality Safety Program, C. M. Hopper; 243 Rickover, Excellence, and Criticality Safety Programs, R. E. Wilson; ACCIDENT ANALYSIS: 249 Transient Analysis of the PIUS Advanced Reactor Design with the TRAC-PF1/MOD2 Code, B. E. Boyack, J. L Steiner, S. C. Harmony, H. J. Stumpf, and J. F. Lime; 278 The Hierarchy-By-Interval Approach to Identifying Important Models that Need Improvement in Severe-Accident Simulation Codes, T. J. Heames, M. Khatib-Rahbar, J. E. Kelly, R. P. Jenks-Johnson, and Y.-S. Chen; 290 RELAP5/MOD3 Code Coupling Model, R. P. Martin; 299 Missiles Caused by Severe Pressurized-Water Reactor Accidents, R. Krieg; DESIGN FEATURES: 310 Validation of COMMIX with Westinghouse AP-600 PCCS Test Data, J. G. Sun, T. H. Chien, J. Ding, and W T. Sha; ENVIRONMENTAL EFFECTS: 321 Spent Nuclear Fuel Characterization for a Bounding Reference Assembly for the Receiving Basin for Off-Site Fuel, S. D. Kahook, R. L. Garrett, L. R. Canas, and M J. Beckum; OPERATING EXPERIENCES: 332 Reactor Shutdown Experience, Compiled by J. W. Cletcher; U.S. NUCLEAR REGULATORY COMMISSION INFORMATION AND ANALYSES: 335 Reactor Coolant System Blowdown at Wolf Creek on September 17, 1994, J. V. Kauffman and S. L. Israel; RECENT DEVELOPMENTS: 344 Reports, Standards, and Safety Guides, D. S. Oueener; 349 Proposed Rule Changes as of June 30, 1995; ANNOUNCEMENTS: 320 Symposium on Acceptability of Risk From Radiation—Application to Manned Space Flight; 320 24th DOE/NRC Nuclear Air Cleaning and Treatment Conference; 361 Radiation Biology and Radiation Protection— Modern Developments and Tendencies in Radiation Biology; 362 1997 IEEE Sixth Conference on Human Factors and Power Plants; 354 The Authors; 360 Reviewers of Nuclear Safety, Vol. 36.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Synergistic Effect of High Sulfur Loading Layered Cathode, Ceramic Separator and Gel Electrolyte

Lithium sulfur (Li-S) batteries are promising candidates for next-generation energy storage devices as they are capable of providing higher energy density and lower cost in comparison to the state of the art Li-ion batteries. To gain these characteristics, there are challenges such as polysulfide crossover, large volume changes during cycling, and deposition of insulating lithium sulfide that need to be alleviated. A popular approach to address these issues is to control the structure and properties of the carbon cathode in order to influence the transport of polysulfides, surface area for reaction, and lithium sulfide deposition. Ceramic separators on the other hand can drastically affect ion diffusion and overall battery performance. Safety concerns regarding the flammable liquid electrolyte can be reduced by deploying gel electrolyte. Towards this direction, we developed a layer-on-layer cathode structure with sulfur-impregnated activated carbon alternating with graphene layer, which was fabricated by Air-assisted electrospray. A much higher sulfur loading compared to slurry cast cathodes can be provided in this method. Combining the new cathode with gel electrolyte can offer higher safety of the battery and capacity retention. Ceramic separator would compensate the reduced ion conductivity of the gel electrolyte and the combination of these variables will be very promising in improvement of battery performance and safety.

25 ENERGY STORAGE↗

Progress and Prospects of Inorganic Solid-State Electrolyte-Based All-Solid-State Pouch Cells

Here, all-solid-state batteries have piqued global research interest because of their unprecedented safety and high energy density. Significant advances have been made in achieving high room-temperature ionic conductivity and good air stability of solid-state electrolytes (SSEs), mitigating the challenges at the electrode–electrolyte interface, and developing feasible manufacturing processes. Along with the advances in fundamental study, all-solid-state pouch cells using inorganic SSEs have been widely demonstrated, revealing their immense potential for industrialization. This review provides an overview of inorganic all-solid-state pouch cells, focusing on ultrathin SSE membranes, sheet-type thick solid-state electrodes, and bipolar stacking. Moreover, several critical parameters directly influencing the energy density of all-solid-state Li-ion and lithium–sulfur pouch cells are outlined. Finally, perspectives on all-solid-state pouch cells are provided and specific metrics to meet certain energy density targets are specified. This review looks to facilitate the development of inorganic all-solid-state pouch cells with high energy density and excellent safety.

25 ENERGY STORAGE↗

HEU Systems at Low Temperatures [Slides]

This project is sponsored by the Nuclear Criticality Safety Program (NCSP) in collaboration with Lawrence Livermore National Laboratory (LLNL) with a novel interest surrounding the transportation of fissile material: there is a concern regarding the inadvertent introduction of the material in a low-temperature environment. The low-temperature environment will be bounded down to temperatures not below -40 ºC, since this is the limit allotted for packages containing general radioactive material exposed to air. Eventually, the goal of the project is to conduct experiments spanning multiple fission energies at these low temperatures, concluding in an International Criticality Safety Benchmark Evaluation Project (ICSBEP) benchmark.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An Introduction to Los Alamos National Laboratory [Slides]

The Weapon Systems Engineering Division (W) provides the system engineering and program management necessary to sustain the safety, reliability, and security of the Los Alamos National Laboratory’s assets in the active United States nuclear stockpile - the B61, W76, W78 and W88. The Division generates key certification data for Annual Assessment supporting the Laboratory Director's letter to the President on the health of those warheads. This role demands ongoing surveillance of the active stockpile and evaluation of the potential impact of any issues through design, engineering, fabrication, testing using state-of-the-art computational simulation tools and engineering test facilities. The Division works in close liaison with the several production facilities across the nuclear security complex as well as with the customers in the US Navy and Air Force.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Modeling and mitigating airborne pathogen risk factors in school buses

Computational fluid dynamics (CFD) models were developed to simulate the impact of different ventilation scenarios on airborne exposure risks in a 72-passenger school bus. Here, scenarios and factors that were investigated included a moving vs. stationary bus, impacts of a heating unit within the bus, and impacts of alternative ventilation scenarios with different combinations of openings (e.g., windows, door, emergency hatch). Results of the simulations showed that when the bus was stationary, use of the heater increased receptor concentrations unless there was another opening. When the bus was moving, simulations with at least two sets of openings separated from each other in the forward and aft directions produced a through-flow condition that reduced concentrations via dilution from outside air by a factor of ten or more. A single opening in a moving bus generally increased concentrations throughout the cabin due to increased mixing with minimal ventilation. The cumulative exposure risk (time-averaged concentrations) was found to be inversely correlated to the air exchange rate. Stationary and moving-bus scenarios that yielded above ~20 air changes per hour resulted in the lowest cumulative exposures. Recommendations from this study were implemented in new safety and operating procedures by the Albuquerque Public Schools Transportation Center.

60 APPLIED LIFE SCIENCES↗

Perception Testing in Fog for Autonomous Flight

As the path towards Urban Air Mobility (UAM) continues to take shape, there are outstanding technical challenges to achieving safe and effective air transportation operations under this new paradigm. To inform and guide technology development for UAM, NASA is investigating the current state-of-the-art in key technology areas including traffic management, detect-and-avoid, and autonomy. In support of this effort, a new perception testbed was developed at NASA Ames Research Center to collect data from an array of sensing systems representative of those that could be found on a future UAM vehicle. This testbed, featuring a Light-Detection-and-Ranging (LIDAR) instrument, a long-wave infrared sensor, and a visible spectrum camera was deployed for a multiday test campaign in the Fog Chamber at Sandia National Laboratories (SNL), in Albuquerque, New Mexico. During the test campaign, fog conditions were created for tests with targets including a human, a resolution chart, and a small unmanned aerial vehicle (sUAV). Here, this paper describes in detail, the developed perception testbed, the experimental setup in the fog chamber, the resulting data, and presents an initial result from analysis of the data with the evaluation of methods to increase contrast through filtering techniques.

aeronautics↗

Shielding Benchmark Comparison - MCNP6.2

This report documents the calculations performed for a shielding code comparison between various Department of Energy (DOE) sites. These shielding calculations were performed using an experiment drawn from the International Handbook of Evaluated Criticality Safety Benchmark Experiments, published by the Organisation for Economic Cooperation and Development/Nuclear Energy Agency (OECD/NEA). The benchmark selected for comparison is ALARM-CF-AIR-LAB-001 (“Neutron Fields in the Three-Section Concrete Labyrinth from Cf-252 Source, Benchmark ALARM CF AIR LAB-001”). The Y-12 submission for this code comparison was performed with Monte Carlo N Particle (MCNP) Transport Code System, Version 6.2 and Automated Variance Reduction Generator (ADVANTG).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiological Safety Analysis Computer (RSAC) Program Version 7.4 Users’ Manual

The Radiological Safety Analysis Computer (RSAC) Program Version 7.4 (RSAC-7) is the newest version of the RSAC legacy code. RSAC-7 calculates the consequences of a release of radionuclides to the atmosphere. Users generates a fission product inventory from either reactor operating history or a nuclear criticality event. RSAC-7 models the effects of high-efficiency particulate air filters or other cleanup systems and calculates the decay and ingrowth during transport through processes, facilities, and the environment. Doses are calculated for inhalation, air immersion, ground surface, ingestion, and cloud gamma pathways. RSAC-7 is used as a tool to evaluate accident conditions in emergency response scenarios, radiological sabotage events, and safety basis accident consequences. This users’ manual contains the mathematical models and operating instructions for RSAC-7. Instructions, screens, and examples are provided to guide the user through the functions provided by RSAC-7. This program is designed for users who are familiar with radiological dose assessment methods.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration: Preprint

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Grid Interactive Micro-Distributed Refrigerated Display Case

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Characterization of Particle and Heat Losses from a High-Temperature Particle Receiver (2 nd Ed)

High - temperature particle receivers are being pursued to enable next - generation concentrating solar thermal power (CSP) systems that can achieve higher temperatures (> 700 C) to enable more efficient power cycles, lower overall system costs, and emerging CSP - based process - heat applications. The objective of this work was to develop characterization methods to quantify the particle and heat losses from the open aperture of the particle receiver. Novel camera - based imaging methods were developed and applied to both laboratory - scale and larger 1 MW t on - sun tests at the National Solar Thermal Test Facility in Albuquerque, New Mexico. Validation of the imaging methods was performed using gravimetric and calorimetric methods. In addition, conventional particle - sampling methods using volumetric particle - air samplers were applied to the on - sun tests to compare particle emission rates with regulatory standards for worker safety and pollution. Novel particle sampling methods using 3 - D printed tipping buckets and tethered balloons were also developed and applied to the on - sun particle - receiver tests. Finally, models were developed to simulate the impact of particle size and wind on particle emissions and concentrations as a function of location. Results showed that particle emissions and concentrations were well below regulatory standards for worker safety and pollution. In addition, estimated particle temperatures and advective heat losses from the camera - based imaging methods correlated well with measured values during the on - sun tests.

14 SOLAR ENERGY↗

Accelerating Transitions to Zero Carbon Power Systems

As power systems evolve, becoming increasingly renewable, distributed, dynamic, and digital, managing them becomes ever more challenging and complex. System operators serve as the "air traffic controllers" for electricity grids, working to balance supply and demand, manage evolving electricity markets, and ensure the safety and reliability of electricity systems. To adapt to the rapidly changing energy landscape and support the transition to modern, zero carbon power systems, system operators must develop and adopt new technologies, approaches, and frameworks. The Global Power System Transformation (G-PST) Consortium is a network of system operators, research institutions, and industry partners working to accelerate and scale the technical solutions required to transform our world's power systems. By developing and sharing robust models and tools, research and demonstration results, knowledge, and innovation, the G-PST Consortium is empowering system operators to transition to 100% renewable energy while ensuring the reliability, safety, and cost-effectiveness of grid operations.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Evaluation of H-Canyon Ventilation Exhaust Tunnel Inspection at the Savannah River Site - 20052

The Department of Energy (DOE) H-Canyon Facility at the Savannah River Site (SRS) is operated by Savannah River Nuclear Solutions (SRNS). The Facility Structural Integrity Program [1] provides a process to inspect, evaluate, and document the conditions of passive safety related structural systems and components, their degradation mechanisms and their impact on the safety envelope. The Structural Integrity Program performs periodic visual inspections to confirm the systems and components can perform their safety function and recommend corrective actions before the function is compromised. The H-Canyon Exhaust Tunnel is part of the H-Canyon Ventilation System and is periodically inspected under the Structural Integrity Program. The Tunnel performs a Safety Class passive design feature function that is available 100% of the time. The underground reinforced concrete Tunnel directs Canyon process air from the Canyon to the Sand Filter System. The radiological and chemical airborne activity coupled with the physical configuration of the tunnel precludes a manned entry into the tunnel to perform the inspection. Unlike active systems that can be subjected to physical testing to confirm capability, qualification calculations, including modeling, is performed to assess passive design feature capabilities relative to operational, accident and natural phenomena hazards events. Input for these calculations come from knowledge of field conditions, design drawings and conservative assumptions. The knowledge of field conditions comes from concrete and soil testing activities as well as inspection data. The use of cameras on crawlers to obtain inspection data and how that data is used in qualification calculations is the focus of this discussion. Remote Tunnel inspections have been performed using cameras on a stick, referred to as pole cameras, prior to Calendar Year 2003 (CY2003). Since CY2003, six camera equipped crawlers have been used. Crawlers have evolved and improved by incorporating lessons learned from the previous inspections. The latest 2019 crawler successfully traveled the entire length of the tunnel between the Canyon and Sand Filter System and captured images that were previously unseen, thus providing key visual data for the Structural Integrity Program report [2]. The inspection data serves as 1) input to qualification calculations, 2) validates current conditions remain bounded by qualification calculations, and 3) documents a record of change over time. This data is vital for the effective evaluation of the tunnel structure and aids with predicting the life cycle service life safety envelope to protect the public, environment, and facility worker. The goal of the 2019 deployment was to use a more robust vehicle to ensure travel over obstacles, perform the inspection with higher resolution cameras, and have the ability to elevate the cameras to view surfaces previously obscured by abandon-in-place ducts in the tunnel. The inspection information will serve to strengthen the input basis for qualification calculations, versus using excessive conservative calculation assumptions. This 2019 inspection was compared with previous crawler visual evidence to identify change over time to project remaining service life and confirm field conditions remain bounded by qualification calculations. The results of the 2019 Exhaust Tunnel inspection continue to improve and provide a firm basis to make sound engineering judgements regarding tunnel capability and approaches in projecting remaining service life with an aging system and component. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Project 57 Air Monitoring Report: (Jan 1 - Dec 31 2018)

During the late 1950s, the Atomic Energy Commission (AEC) (now the U.S. Department of Energy [DOE]) conducted a series of safety experiments to determine if a nuclear device subjected to a large conventional explosives detonation would result in a nuclear yield. The AEC obtained temporary use of a large portion of western Emigrant Valley from the U.S. Department of Defense (DOD) for one of these experiments: Project 57. Following the Project 57 safety experiment, the AEC fenced the contaminated area and returned control of the surrounding land to the DOD. Emigrant Valley is part of the Nevada Test and Training Range (NTTR). For safety and security reasons, access to the NTTR is controlled using both physical (i.e., fences) and administrative (e.g., signs and postings) controls. Therefore, the public cannot access the Project 57 site and there are no known human receptors that routinely access the site. Project 57 was detonated on April 24, 1957, in Emigrant Valley approximately 13 mi (21 km) northeast of the north end of Yucca Flat. This test was undertaken to develop: (1) a means of estimating immediate distribution and long-term redistribution of plutonium dispersed during a nonnuclear detonation; (2) biomedical evaluation techniques for use in likely plutonium-laden environments; (3) methods of decontaminating ground areas, pavements, and building materials; and (4) alpha survey instruments and field monitoring procedures to promptly estimate contaminant deposition. Although the test did not result in the fission of nuclear materials, it did disseminate plutonium across the ground surface. Various radiological surveys have been performed in the area since Project 57 was conducted. The AEC delineated the area containing radioactive material based on radioactivity surveys performed shortly after the test was conducted. A designated Contamination Area (CA), marked by a fence, was established later. The distribution of americium-241 (Am-241) in the area was determined again in a 1997 flyover, which showed Am-241 ranging from as much as 70,000 counts per second (cps) at ground zero to background (<70 cps). This survey also documented Am-241 radioactivity on the ground surface beyond the east side CA fence at levels of up to 150 cps. In 2007, the DOE expanded the CA by posting “Contamination Area” signs 200 ft to 400 ft (60 m to 120 m) beyond the original fence, which formed a new CA boundary.

54 ENVIRONMENTAL SCIENCES↗