Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Air Distribution Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Formal Verification of a Conflict Resolution and Recovery Algorithm

New air traffic management concepts distribute the duty of traffic separation among system participants. As a consequence, these concepts have a greater dependency and rely heavily on on-board software and hardware systems. One example of a new on-board capability in a distributed air traffic management system is air traffic conflict detection and resolution (CD&R). Traditional methods for safety assessment such as human-in-the-loop simulations, testing, and flight experiments may not be sufficient for this highly distributed system as the set of possible scenarios is too large to have a reasonable coverage. This paper proposes a new method for the safety assessment of avionics systems that makes use of formal methods to drive the development of critical systems. As a case study of this approach, the mechanical veri.cation of an algorithm for air traffic conflict resolution and recovery called RR3D is presented. The RR3D algorithm uses a geometric optimization technique to provide a choice of resolution and recovery maneuvers. If the aircraft adheres to these maneuvers, they will bring the aircraft out of conflict and the aircraft will follow a conflict-free path to its original destination. Veri.cation of RR3D is carried out using the Prototype Verification System (PVS).

Maddalon, Jeffrey↗

Solar Heating System installed at Belz Investment Company, Memphis, Tennessee

A hot air solar system which utilizes flat plate air collectors is discussed. Collector areas for each of four buildings cover 780 sq ft, with storage capacity of 390 cu ft per building. The air system has a special air handling unit to move air through the collectors and into and out of the rock storage, with connection to the air duct distribution system. The heat of the motor is added to the heat delivered to the system. The solar system also includes four motorized special low leakage dampers and two gravity fabric dampers. The system is automatically controlled by a solid state controller with three thermistors: one located in the collectors, one in the rock box to plenum, one in the return air duct from the heated space. A three stage heating thermostat, located in the conditioned space, controls the operation.

Source record↗

Existing Whole-House Solutions Case Study: Inverted Attic Bulkhead for HVAC Ductwork, Roseville, California

In this project, the Building America research team, IBACOS, worked with K. Hovnanian Homes to monitor the effectiveness of the space conditioning system in a 2,253-ft single-story slab-on-grade ranch house for an occupied test house (new construction) in Roseville, California. One year of monitoring and analysis focused on maintaining acceptable temperature and relative humidity levels in several rooms of the home, as well as room-to-room differences and the actual measured energy consumption by the space conditioning system. To describe the performance and comfort in the home, the research team selected representative design days and extreme days from the annual data for analysis. To ensure that temperature differences were within reasonable occupant expectations, the team followed Air Conditioning Contractors of America guidance. At the end of the monitoring period, the occupant of the home had no comfort complaints in the home.

air distribution system↗

Comfort and HVAC Performance for a New Construction Occupied Test House in Roseville, California

K. Hovnanian® Homes constructed a 2,253-ft2 single-story slab-on-grade ranch house for an occupied test house (new construction) in Roseville, California. One year of monitoring and analysis focused on the effectiveness of the space conditioning system at maintaining acceptable temperature and relative humidity levels in several rooms of the home, as well as room-to-room differences and the actual measured energy consumption by the space conditioning system. In this home, the air handler unit (AHU) and ducts were relocated to inside the thermal boundary. The AHU was relocated from the attic to a mechanical closet, and the ductwork was located inside an insulated and air-sealed bulkhead in the attic. To describe the performance and comfort in the home, the research team selected representative design days and extreme days from the annual data for analysis. To ensure that temperature differences were within reasonable occupant expectations, the team followed Air Conditioning Contractors of America guidance. At the end of the monitoring period, the occupant of the home had no comfort complaints in the home. Any variance between the modeled heating and cooling energy and the actual amounts used can be attributed to the variance in temperatures at the thermostat versus the modeled inputs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Systematic Classification for HVAC Systems and Components

Depending on the application, the complexity of an HVAC system can range from a small fan coil unit to a large centralized air conditioning system with primary and secondary distribution loops, and central plant components. Currently, the taxonomy of HVAC systems and the components has various aspects, which can get quite complex because of the various components and system configurations. For example, based on cooling and heating medium delivered to terminal units, systems can be classified as either air systems, water systems or air-water systems. In addition, some of the system names might be commonly used in a confusing manner, such as “unitary system” vs. “packaged system.” Without a systematic classification, these components and system terminology can be confusing to understand or differentiate from each other, and it creates ambiguity in communication, interpretation, and documentation. It is valuable to organize and classify HVAC systems and components so that they can be easily understood and used in a consistent manner. This paper aims to develop a systematic classification of HVAC systems and components. First, we summarize the HVAC component information and definitions based on published literature, such as ASHRAE handbooks, regulations, and rating standards. Then, we identify common HVAC system types and map them to the collected components in a meaningful way. Classification charts are generated and described based on the component information. Six main categories are identified for the HVAC components and equipment, i.e., heating and cooling production, heat extraction and rejection, air handling process, distribution system, terminal use, and stand-alone system. Components for each main category are further analyzed and classified in detail. More than fifty system names are identified and grouped based on their characteristics. The result from this paper will be helpful for education, communication, and systems and component documentation.

Li, Han↗

Inverted Attic Bulkhead for HVAC Ductwork: Roseville, California (Fact Sheet)

K. Hovnanian Homes constructed a 2,253-ft single-story slab-on-grade ranch house for an occupied test house (new construction) in Roseville, California. One year of monitoring and analysis focused on the effectiveness of the space conditioning system at maintaining acceptable temperature and relative humidity levels in several rooms of the home, as well as room-to-room differences and the actual measured energy consumption by the space conditioning system. In this home, the air handler unit (AHU) and ducts were relocated to inside the thermal boundary. The AHU was relocated from the attic to a mechanical closet, and the ductwork was located inside an insulated and air-sealed bulkhead in the attic. To describe the performance and comfort in the home, the research team selected representative design days and extreme days from the annual data for analysis. To ensure that temperature differences were within reasonable occupant expectations, the team followed Air Conditioning Contractors of America guidance. At the end of the monitoring period, the occupant of the home had no comfort complaints in the home. Any variance between the modeled heating and cooling energy and the actual amounts used can be attributed to the variance in temperatures at the thermostat versus the modeled inputs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comfort and HVAC Performance for a New Construction Occupied Test House in Roseville, California

K. Hovnanian(R) Homes(R) constructed a 2,253-ft2 single-story slab-on-grade ranch house for an occupied test house (new construction) in Roseville, California. One year of monitoring and analysis focused on the effectiveness of the space conditioning system at maintaining acceptable temperature and relative humidity levels in several rooms of the home, as well as room-to-room differences and the actual measured energy consumption by the space conditioning system. In this home, the air handler unit (AHU) and ducts were relocated to inside the thermal boundary. The AHU was relocated from the attic to a mechanical closet, and the ductwork was located inside an insulated and air-sealed bulkhead in the attic. To describe the performance and comfort in the home, the research team selected representative design days and extreme days from the annual data for analysis. To ensure that temperature differences were within reasonable occupant expectations, the team followed Air Conditioning Contractors of America guidance. At the end of the monitoring period, the occupant of the home had no comfort complaints in the home. Any variance between the modeled heating and cooling energy and the actual amounts used can be attributed to the variance in temperatures at the thermostat versus the modeled inputs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ducts Sealing Using Injected Spray Sealant, Raleigh, North Carolina (Fact Sheet)

In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques - manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $\$ $275 to $\$ $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Distribution Retrofit Strategies for Affordable Housing

In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques, manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multiunit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder are two story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $\$$275 to $\$$511 per unit and for the injected spray sealant the cost was $\$$700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Distribution Retrofit Strategies for Affordable Housing

In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques -- manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simplified Space Conditioning in Low-Load Homes: Results from Pittsburgh, Pennsylvania, New Construction Unoccupied Test House

Field testing was performed in a new construction unoccupied test house in Pittsburgh, Pennsylvania. Four air-based heating, ventilation, and air conditioning distribution systems--a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, a system with transfer fans to the bedrooms, and a system with no ductwork to the bedrooms--were evaluated during heating, cooling, and midseason conditions. The relative ability of each system was assessed with respect to relevant Air Conditioning Contractors of America and ASHRAE standards for house temperature uniformity and stability, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simplified Space Conditioning in Low-Load Homes: Results from Pittsburgh, Pennsylvania, New Construction Unoccupied Test House

Field testing was performed in a new construction unoccupied test house in Pittsburgh, PA. Four air-based heating, ventilation, and air conditioning distribution systems—a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, a system with transfer fans to the bedrooms, and a system with no ductwork to the bedrooms—were evaluated during heating, cooling, and midseason conditions. The relative ability of each system was assessed with respect to relevant Air Conditioning Contractors of America and ASHRAE standards for house temperature uniformity and stability, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Corrosion Risk Assessment Model for Underground Piping

The Pressure Systems Manager at NASA Ames Research Center (ARC) has embarked on a project to collect data and develop risk assessment models to support risk-informed decision making regarding future inspections of underground pipes at ARC. This paper shows progress in one area of this project - a corrosion risk assessment model for the underground high-pressure air distribution piping system at ARC. It consists of a Corrosion Model of pipe-segments, a Pipe Wrap Protection Model; and a Pipe Stress Model for a pipe segment. A Monte Carlo simulation of the combined models provides a distribution of the failure probabilities. Sensitivity study results show that the model uncertainty, or lack of knowledge, is the dominant contributor to the calculated unreliability of the underground piping system. As a result, the Pressure Systems Manager may consider investing resources specifically focused on reducing these uncertainties. Future work includes completing the data collection effort for the existing ground based pressure systems and applying the risk models to risk-based inspection strategies of the underground pipes at ARC.

Datta, Koushik↗

Development and Testing of a Vehicle Management System for Autonomous Spacecraft Habitat Operations

As the increased distance between Earth-based mission control and the spacecraft results in increasing communication delays, small crews cannot take on all functions performed by ground today, and so vehicles must be more automated to reduce the crew workload for such missions. In addition, both near-term and future missions will feature significant periods when crew is not present, meaning the vehicles will need to operate themselves autonomously. NASA's Advanced Exploration Systems Program pioneers new approaches for rapidly developing prototype systems, demonstrating key capabilities, and validating operational concepts for future human missions beyond low-Earth orbit. Under this program, NASA has developed and demonstrated multiple technologies to enable the autonomous operation of a dormant space habitat. These technologies included a fault-tolerant avionics architecture, novel spacecraft power system and power system controller, and autonomy software to control the habitat. The demonstration involved simulation of the habitat and multiple spacecraft sub-systems (power storage and distribution, avionics, and air-side life-support) during a multi-day test at NASA's Johnson Space Center. The foundation of the demonstration was ‘quiescent operations' of a habitat during a 55 minute eclipse period. For this demonstration, the spacecraft power distribution system and air-side life support system were simulated at a high level of fidelity; additional systems were managed, but with lower fidelity operational constraints and system behavior. Operational constraints for real and simulated loads were developed by analyzing on-orbit hardware and evaluating future Exploration capable technology. A total of 13 real and simulated loads were used during the test. Eight scenarios including both nominal and off-nominal conditions were performed. Over the course of the test, every application performed its desired functions successfully during the simulated tests. The results will inform both future tests, as well as provide insight to NASA's domestic and international partners, as they construct the next generation of space habitats to be used on beyond-Earth missions.

Autonomous Systems and Operations↗

Distributed Sensor Fusion of Ground and Air Nodes Using Vision and Radar Modalities for Tracking Multirotor Small Uncrewed Air Systems and Birds

High-density airspace operations with multiple aircraft type and potentially noncooperative aircraft require distributed sensor detection and tracking systems to monitor airspace for safe, autonomous flight operations for advanced air mobility, urban air mobility, and high density small uncrewed air systems (SUAS) flight concepts. This work collected data using a distributed radar and camera sensor framework during the NASA Advanced Air Mobility High Density Vertiplex project SUAS flight operation. Node locations include on an onboard SUAS, affixed to the Landing and Impact Research Facility with approximate 200ft elevation, on a tripod on first-floor roof with an approximate elevation of 20 ft, and on a tripod on a concrete pad that is approximately 4 ft above sea level. Each node includes camera, radar, and GPS.

Beyond Visual Line of Sight↗

Evaluation of nonlinear control performance of air handling units under variable operation conditions using root distribution approach

The control systems at Air handling units (AHUs) have nonlinear nature, resulting potentially in sluggish, aggressive, or oscillatory responses under variable operation conditions. This paper is to develop an approach for evaluating the nonlinear control performance of AHUs under variable operation conditions and for identifying the impact of varying multiple operation parameters which guides controller design. To do so, an operation parameter-based root distribution technique, intended to sketch the paths traced by closed-loop poles as multiple operation parameters are varied, is first introduced. The technique—which may be viewed as an extension of conventional, single-variable root locus—is then applied to a fan speed control system that includes a motor with a variable frequency drive and a supply fan with an air duct under variable fan speed and duct static pressure. Using the technique, the system’s stability region is graphically identified. The system is also found to be aggressive and gradually lose its stability as the fan speed decreases and the duct static pressure increases, which is validated by the field tests. Here, the root distribution approach is an effective tool to evaluate the performance of any nonlinear control systems at AHUs with multiple variable operation parameters without requiring time-domain simulations.

42 ENGINEERING↗

Automated Control of Transactive HVACs in Energy Distribution Systems

Heating, Ventilation, and Air Conditioning (HVAC) systems contribute significantly to a building’s energy consumption. In the recent years, there is an increased interest in developing transactive approaches which could enable automated and flexible scheduling of HVAC systems based on the customer demand and the electricity prices decided by the suppliers. Flexible and automated scheduling of the HVAC systems make it a prime source for participation in residential demand response or transactive energy systems. Therefore, it is of significant interest to identify an optimal strategy to control the HVAC systems. Here, reducing the energy cost while keeping the comfort level acceptable to the users, we argue that such a control strategy should consider both the energy cost and user comfort simultaneously. Accordingly, we develop the control strategy through the solution of an optimization problem that balances between the energy cost and consumer’s dissatisfaction. This optimization enables us to solve a decision-making problem through first price prediction and then choosing HVAC temperature settings throughout the day based on the predicted price, history of the price and HVAC settings, and outside temperature. More specifically, we formulate the control design as a Markov decision process (MDP) using deep neural networks and use Deep Deterministic Policy Gradients (DDPG)-based deep reinforcement learning algorithm to find the optimal control strategy for HVAC systems that balances between electricity cost and user comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New Whole-House Solutions Case Study: Winchester Homes and Camberly Homes

The Partnership for Home Innovation team worked with the builder to develop a new set of high performance home designs—including advanced wall and HVAC systems—that could be applicable on a production scale. The new home designs are to be constructed in the mixed humid climate zone and could eventually apply to all of the builder's home designs to meet or exceed future energy codes or performance-based programs. However, the builder recognized that the combination of new wall framing designs and materials, higher levels of insulation in the wall cavity, and more detailed air sealing to achieve lower infiltration rates changes the moisture characteristics of the wall system. In order to ensure long term durability and repeatable successful implementation with few call-backs, this report demonstrates through measured data that the wall system functions as a dynamic system, responding to changing interior and outdoor environmental conditions within recognized limits of the materials that make up the wall system. A similar investigation was made with respect to the complete redesign of the heating, cooling, air distribution, and ventilation systems intended to optimize the equipment size and configuration to significantly improve efficiency while maintaining indoor comfort. Recognizing the need to demonstrate the benefits of these efficiency features, the builder offered a new house model to serve as a test case to develop framing designs, evaluate material selections and installation requirements, changes to work scopes and contractor learning curves, as well as to compare theoretical performance characteristics with measured results.

2x6 walls↗