Effect of Air Temperature and Relative Humidity at Various Fuel-Air Ratios on Exhaust Emissions on a Per-Mode Basis of an AVCO Lycoming 0-320 Diad Light Aircraft Engine: Volume 1: Results and Plotted Data

A carbureted four cylinder air cooled 0-320 DIAD Lycoming aircraft engine was tested to establish the effects of air temperature and humidity at various fuel-air ratios on the exhaust emissions on a per-mode basis. The test conditions include carburetor lean out at air temperatures of 50, 59, 80, and 100 F at relative humidities of 0, 30, 60, and 80 percent. Temperature humidity effects at the higher values of air temperature and relative humidity tested indicated that the HC and CO emissions increased significantly, while the NOx emissions decreased. Even at a fixed fuel air ratio, the HC emissions increase and the NOx emissions decrease at the higher values of air temperature and humidity.

Skorobatckyi, M.↗

Optical Air Flow Measurements for Flight Tests and Flight Testing Optical Air Flow Meters

Optical air flow measurements can support the testing of aircraft and can be instrumental to in-flight investigations of the atmosphere or atmospheric phenomena. Furthermore, optical air flow meters potentially contribute as avionics systems to flight safety and as air data systems. The qualification of these instruments for the flight environment is where we encounter the systems in flight testing. An overview is presented of different optical air flow measurement techniques applied in flight and what can be achieved with the techniques for flight test purposes is reviewed. All in-flight optical airflow velocity measurements use light scattering. Light is scattered on both air molecules and aerosols entrained in the air. Basic principles of making optical measurements in flight, some basic optical concepts, electronic concepts, optoelectronic interfaces, and some atmospheric processes associated with natural aerosols are reviewed. Safety aspects in applying the technique are shortly addressed. The different applications of the technique are listed and some typical examples are presented. Recently NASA acquired new data on mountain rotors, mountain induced turbulence, with the ACLAIM system. Rotor position was identified using the lidar system and the potentially hazardous air flow profile was monitored by the ACLAIM system.

Jentink, Henk W.↗

Global Evaluation of Terrestrial Near-Surface Air Temperature and Specific Humidity Retrievals from the Atmospheric Infrared Sounder (AIRS)

Global observations of near-surface air temperature and specific humidity over land are needed for a variety of applications, including to constrain global estimates of evapotranspiration (ET). Spaceborne hyperspectral observations, such as those from NASA’s Atmospheric Infrared Sounder (AIRS) mission, show promise for meeting this need, yet there are surprisingly few validation studies of AIRS near-surface atmospheric state retrievals. In this study, we use triple collocation to validate AIRS Level 3 retrievals of near-surface atmospheric state over land using twelve years of gridded station observations and two reanalyses. Deseasonalized AIRS retrievals correlate well with deseasonalized ground observations outside the tropics, but correlate less well in the tropics. Lower temporal sensitivity near the surface in the tropics contributes to the lower correlation for near-surface air temperature and is consistent with known physics of the tropical atmosphere, in which temperatures outside the boundary layer (which dominate the AIRS retrieval signal) are poorly correlated with those near the surface. Retrievals in the tropics may also be more susceptible to errors in cloud-clearing algorithms, and to uncertainty in surface emissivity. Since ET is greatest in the tropics, and tropical measurement networks are particularly sparse, this work motivates new approaches for measuring ET in the tropics.

Evapotranspiration↗

Investigation of the Penetration on an Air Jet Directed Perpendicularly to an Air Stream

An experimental investigation was conducted to determine the penetration of a circular air Jet directed perpendicularly to an air stream as a function of Jet density, Jet velocity, air-stream density, air-stream velocity, Jet diameter, and distance downstream from the Jet. The penetration was determined for nearly constant values of air-stream density at two tunnel velocities, four Jet diameters, four positions downstream of the Jet, and for a large range of Jet velocities and densities. An equation for the penetration was obtained in terms of the Jet diameter, the distance downstream from the jet, and the ratios of Jet and air-stream velocities and densities.

JETS↗

Evaluation of Initial and Mid-Term Air Traffic Procedures for Urban Air Mobility Operations

Urban air mobility (UAM) operations are expected to expand in scale over the next several years as novel aircraft types, including electric vertical takeoff and landing aircraft, are certified and begin operations. These new aircraft may increase safety, decrease noise, and lower operating costs compared with helicopters, allowing them to operate in ways existing aircraft do not. It is vital that these expanded operations are compatible with and do not disrupt existing operations or the air traffic management system. To study the ways in which scaled UAM operations can best integrate in the national airspace system, NASA and Joby Aviation partnered to conduct a high-fidelity air traffic controller-in-the-loop study. Building on air traffic procedures used to manage high tempo operations in other parts of the airspace, new procedures, routes, and communications protocols were developed and tested by retired controllers in NASA’s Future Flight Central tower simulation facility. In addition, new cooperative airspace constructs in the form of corridors were developed to understand their potential contributions to even greater scales of operation. The controllers managed traffic scenarios in the Dallas-Fort Worth and Dallas Love Field airports consisting of fleets of up to 100 UAM aircraft operating alongside traditional traffic . Metrics for air traffic controller workload, duration of communications, departure delays, and other measures of allowable aircraft throughput were collected. The analysis indicates that using today’s procedures for initial UAM operations under nominal conditions could enable up to 40 operations per hour to an airport’s central terminal area if that involved crossing a runway and up to 55operations per hour if reaching the central terminal did not involve crossing a runway. Operations at these tempos did not delay or otherwise interfere with simulated runway traffic and were rated acceptable by the air traffic controllers. The new corridor constructs dramatically lowered controller workload in certain circumstances, suggesting they may be effective in further increasing the allowable scale of operations.

Urban Air Mobility↗

Evaluation of Initial and Mid-Term Air Traffic Procedures for Urban Air Mobility

Urban air mobility (UAM) operations are expected to expand in scale over the next several years as novel aircraft types, including electric vertical takeoff and landing aircraft, are certified and begin operations. These new aircraft may increase safety, decrease noise, and lower operating costs compared with helicopters, allowing them to operate in ways existing aircraft do not. It is vital that these expanded operations are compatible with and do not disrupt existing operations or the air traffic management system. To study the ways in which scaled UAM operations can best integrate in the national airspace system, NASA and Joby Aviation partnered to conduct a high-fidelity air traffic controller-in-the-loop study. Building on air traffic procedures used to manage high tempo operations in other parts of the airspace, new procedures, routes, and communications protocols were developed and tested by retired controllers in NASA’s Future Flight Central tower simulation facility. In addition, new cooperative airspace constructs in the form of corridors were developed to understand their potential contributions to even greater scales of operation. The controllers managed traffic scenarios in the Dallas-Fort Worth and Dallas Love Field airports consisting of fleets of up to 100 UAM aircraft operating alongside traditional traffic. Metrics for air traffic controller workload, duration of communications, departure delays, and other measures of allowable aircraft throughput were collected. The analysis indicates that using today’s procedures for initial UAM operations under nominal conditions could enable up to 40 operations per hour to an airport’s central terminal area if that involved crossing a runway and up to 55 operations per hour if reaching the central terminal did not involve crossing a runway. Operations at these tempos did not delay or otherwise interfere with simulated runway traffic and were rated acceptable by the air traffic controllers. The new corridor constructs dramatically lowered controller workload in certain circumstances, suggesting they may be effective in further increasing the allowable scale of operations.

Advanced Air Mobility↗

Long-Life, Ultrahigh-Nickel Cathodes with Excellent Air Storage Stability for High-Energy Density Lithium-Based Batteries

With increased energy density and cost advantage, ultrahigh-nickel layered oxides (LiNi x M 1-x O 2 , x = 0.9 - 1.0) are becoming front-runner as cathodes for next-generation lithium-based batteries, yet their commercialization is blocked both by severe capacity fade and exponentially aggravated air degradation. Thus, it is imperative to find effective solutions to address these issues simultaneously. Here, a significant enhancement in both the cycling and air storage stability of the ultrahigh-Ni cathode LiNi 0.94 Co 0.06 O 2 is achieved via a distinctive phosphoric acid treatment strategy. The modified cathode displays remarkably improved capacity retention (from 36 % to 80 % after 1,000 cycles) and rate capability (from 0 to 105 mA h g -1 at 30C rate) in pouch cells. Impressively, the modified cathode, after air storage for 450 days, maintains the morphology and 92% of the initial capacity of the fresh sample with excellent cyclability. Comprehensive interphase and structural analyses reveal that the enhanced electrochemical performance is due to a highly stabilized electrode/electrolyte interphase that suppresses electrode corrosion and lattice reconstruction. The excellent air stability results from an adsorption-buffering effect enabled by phosphoric acid to air attack. Finally, the study demonstrates an engineering pathway to improve the cycling and air stability, facilitating the practical viability of high-capacity, affordable, ultrahigh-Ni cathodes in lithium-based batteries.

25 ENERGY STORAGE↗

An Observational and modeling strategy to investigate the impact of remote sources on local air quality: A Houston, Texas case study from the Second Texas Air Quality Study (TEXAQS II)

Quantifying the impacts of remote sources on individual air quality exceedances remains a significant challenge for air quality forecasting. One goal of the 2006 Texas Air Quality Study (TEXAQS II) was to assess the impact of distant sources on air quality in east Texas. From 23-30 August 2006, retrievals of tropospheric carbon monoxide (CO) from NASA’s Atmospheric InfraRed Sounder (AIRS) reveal the transport of CO from fires in the United States Pacific Northwest to Houston, Texas. This transport occurred behind a cold front and contributed to the worst ozone exceedance period of the summer in the Houston area. We present supporting satellite observations from the NASA A-Train constellation of the vertical distribution of smoke aerosols and CO. Ground-based in situ CO measurements in Oklahoma and Texas track the CO plume as it moves south and indicate mixing of the aloft plume to the surface by turbulence in the nocturnal boundary layer and convection during the day. Ground-based aerosol speciation and lidar observations do not find appreciable smoke aerosol transport for this case. However, MODIS aerosol optical depths and model simulations indicate some smoke aerosols were transported from the Pacific Northwest through Texas to the Gulf of Mexico. Chemical transport and forward trajectory models confirm the three major observations: (1) the AIRS envisioned CO transport, (2) the satellite determined smoke plume height, and (3) the timing of the observed surface CO increases. Further, the forward trajectory simulations find two of the largest Pacific Northwest fires likely had the most significant impact.

54 ENVIRONMENTAL SCIENCES↗

A geophysical shock and air blast simulator at the National Ignition Facility

The energy partitioning energy coupling experiments at the National Ignition Facility (NIF) have been designed to measure simultaneously the coupling of energy from a laser-driven target into both ground shock and air blast overpressure to nearby media. The source target for the experiment is positioned at a known height above the ground-surface simulant and is heated by four beams from the NIF. The resulting target energy density and specific energy are equal to those of a low-yield nuclear device. The ground-shock stress waves and atmospheric overpressure waveforms that result in our test system are hydrodynamically scaled analogs of full-scale seismic and air blast phenomena. This report summarizes the development of the platform, the simulations, and calculations that underpin the physics measurements that are being made, and finally the data that were measured. Agreement between the data and simulation of the order of a factor of two to three is seen for air blast quantities such as peak overpressure. Historical underground test data for seismic phenomena measured sensor displacements; we measure the stresses generated in our ground-surrogate medium. We find factors-of-a-few agreement between our measured peak stresses and predictions with modern geophysical computer codes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Released air during vapor and air cavitation

Cavitation today is a very important problem that is solved by means of experimental and mathematical methods. The article deals with the generation of cavitation in convergent divergent nozzle of rectangular cross section. Measurement of pressure, flow rate, temperature, amount of dissolved air in the liquid and visualization of cavitation area using high-speed camera was performed for different flow rates. The measurement results were generalized by dimensionless analysis, which allows easy detection of cavitation in the nozzle. For numerical simulation the multiphase mathematical model of cavitation consisting of water and vapor was created. During verification the disagreement with the measurements for higher flow rates was proved, therefore the model was extended to multiphase mathematical model (water, vapor and air), due to release of dissolved air. For the mathematical modeling the multiphase turbulence RNG k-ε model for low Reynolds number flow with vapor and air cavitation was used. Subsequently the sizes of the cavitation area were verified. In article the inlet pressure and loss coefficient depending on the amount of air added to the mathematical model are evaluated. On the basis of the approach it may be create a methodology to estimate the amount of released air added at the inlet to the modeled area.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In-Cab Air Quality of Trucks Air Conditioned and Kept in Electrified Truck Stop

At night, long-haul truck drivers rest inside the cabins of their vehicles. Therefore, the in-cab air quality while air conditioning (A/C) is being provided can be a great concern to the drivers health. The effect of using different A/C methods [truck's A/C, auxiliary power unit (APU), and truck stop electrification (TSE) unit] on in-cab air quality of a heavy-duty diesel vehicle was investigated at an electrified truck stop in the El Paso, Texas, area. The research team measured the in-cabin and the ambient air quality adjacent to the parked diesel truck as well as emissions from the truck and an APU while it was providing A/C. The measured results were compared and analyzed. On the basis of these results, it was concluded that the TSE unit provided better in-cab air quality while supplying A/C. Furthermore, the truck and APU exhaust emissions were measured, and fuel consumption of the truck (while idling) and the APU (during operation) were compared. The results led to the finding that emissions from the APU were less than those from the truck's engine idling, but the APU consumed more fuel than the engine while providing A/C under given conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Proposal for a Vehicle Level Test Procedure to Measure Air Conditioning Fuel Use

The air-conditioning (A/C) compressor load significantly impacts the fuel economy of conventional vehicles and the fuel use/range of plug-in hybrid electric vehicles (PHEV). A National Renewable Energy Laboratory (NREL) vehicle performance analysis shows the operation of the air conditioner reduces the charge depletion range of a 40-mile range PHEV from 18% to 30% in a worst case hot environment. Designing for air conditioning electrical loads impacts PHEV and electric vehicle (EV) energy storage system size and cost. While automobile manufacturers have climate control procedures to assess A/C performance, and the U.S. EPA has the SCO3 drive cycle to measure indirect A/C emissions, there is no automotive industry consensus on a vehicle level A/C fuel use test procedure. With increasing attention on A/C fuel use due to increased regulatory activities and the development of PHEVs and EVs, a test procedure is needed to accurately assess the impact of climate control loads. A vehicle thermal soak period is recommended, with solar lamps that meet the SCO3 requirements or an alternative heating method such as portable electric heaters. After soaking, the vehicle is operated over repeated drive cycles or at a constant speed until steady-state cabin air temperature is attained. With this method, the cooldown and steady-state A/C fuel use are measured. This method can be run at either different ambient temperatures to provide data for the GREEN-MAC-LCCP model temperature bins or at a single representative ambient temperature. Vehicles with automatic climate systems are allowed to control as designed, while vehicles with manual climate systems are adjusted to approximate expected climate control settings. An A/C off test is also run for all drive profiles. This procedure measures approximate real-world A/C fuel use and assess the impact of thermal load reduction strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗