Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Aerodynamic Decelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Study of solid rocket motor for space shuttle booster, volume 2, book 5, appendices E thru H

Preliminary parametric studies were performed to establish size, weight and packaging arrangements for aerodynamic decelerator devices that could be used for recovery of the expended solid propellant rocket motors used in the launch phase of the Space Shuttle System. Computations were made using standard engineering analysis techniques. Terminal stage parachutes were sized to provide equilibrium descent velocities for water entry that are presently thought to be acceptable without developing loads that could exceed the boosters structural integrity. The performance characteristics of the aerodynamic parachute decelerator devices considered are based on analysis and prior test results for similar configurations and are assumed to be maintained at the scale requirements of the present problem.

Source record↗

OVERFLOW Analysis of Supersonic Retropropulsion Testing on a Blunt Mars Entry Vehicle Concept

Supersonic retropropulsion (SRP) flow over a Hypersonic Inflatable Aerodynamic Decelerator (HIAD) blunt-body vehicle was simulated using the Overflow Computational Fluid Dynamics (CFD) solver. Two nozzle configurations were tested (1E and 1F) as a subset of the seven total configurations in the Descent System Study (DSS) testing campaign. A generalized, Adaptive Mesh Refinement (AMR) shock capturing and plume refinement technique was developed and calibrated for producing automatic and unique grid systems optimized for any given testing condition. Solution independence from grid resolution was determined by successively increasing grid refinement until asymptotic convergence of the mean aerodynamic loads was observed. Overflow Reynolds-averaged Navier-Stokes (RANS) solutions produced realistic SRP flow phenomena, including Mach disk normal shocks contained in high-thrust plumes and bow shock triple-points. Solutions for the 1E nozzle configuration were steady. Conversely, a subset of the 1F test conditions were unsteady and exhibited periodic, non-sinusoidal expansions and contractions of the streamwise-oriented plume, resulting in unsteady aerodynamic loads on the vehicle. Initial investigations into the effect of turbulence modeling fidelity demonstrated significant differences between the aerodynamic loads simulated with RANS and Detached Eddy Simulation (DES). Multiple flow mechanisms were identified as root causes of these differences, including bow shock shape augmentation and reduced entrainment due to reduced turbulence in the DES simulations. Initial comparisons of pitching moment control authority and aerodynamic drag performance between the tested nozzle configurations demonstrated that the 1E configuration may be more advantageous for the Mars Entry, Descent, and Landing (EDL) task.

Supersonic Retropropulsion↗

OVERFLOW Analysis of Supersonic Retropropulsion Testing on a Blunt Mars Entry Vehicle Concept

Supersonic retropropulsion (SRP) flow over a Hypersonic Inflatable Aerodynamic Decelerator (HIAD) blunt-body vehicle was simulated using the Overflow Computational Fluid Dynamics (CFD) solver. Two nozzle configurations were tested (1E and 1F) as a subset of the seven total configurations in the Descent System Study (DSS) testing campaign. A generalized, Adaptive Mesh Refinement (AMR) shock capturing and plume refinement technique was developed and calibrated for producing automatic and unique grid systems optimized for any given testing condition. Solution independence from grid resolution was determined by successively increasing grid refinement until asymptotic convergence of the mean aerodynamic loads was observed. Overflow Reynolds-averaged Navier-Stokes (RANS) solutions produced realistic SRP flow phenomena, including Mach disk normal shocks contained in high-thrust plumes and bow shock triple-points. Solutions for the 1E nozzle configuration were steady. Conversely, a subset of the 1F test conditions were unsteady and exhibited periodic, non-sinusoidal expansions and contractions of the streamwise-oriented plume, resulting in unsteady aerodynamic loads on the vehicle. Initial investigations into the effect of turbulence modeling fidelity demonstrated significant differences between the aerodynamic loads simulated with RANS and Detached Eddy Simulation (DES). Multiple flow mechanisms were identified as root causes of these differences, including bow shock shape augmentation and reduced entrainment due to reduced turbulence in the DES simulations. Initial comparisons of pitching moment control authority and aerodynamic drag performance between the tested nozzle configurations demonstrated that the 1E configuration may be more advantageous for the Mars Entry, Descent, and Landing (EDL) task.

Supersonic Retropropulsion↗

OVERFLOW Analysis of Supersonic Retropropulsion Testing on a Blunt Mars Entry Vehicle Concept

Supersonic Retropropulsion (SRP) flow over a Hypersonic Inflatable Aerodynamic Decelerator (HIAD) blunt-body vehicle was simulated using the OVERFLOW Computational Fluid Dynamics (CFD) solver. Two nozzle configurations were tested (1E and 1F) as a subset of the seven total configurations in the Descent Systems Study (DSS) testing campaign. A generalized, Adaptive Mesh Refinement (AMR) shock capturing and plume refinement technique was developed and calibrated for producing automatic and optimized grid systems unique to any given testing condition. Simulations were subjected to successive levels of grid refinement in order to determine solution independence from grid resolution. OVERFLOW Reynolds Averaged Navier-Stokes (RANS) solutions produced realistic SRP flow phenomena, including Mach disk normal shocks contained in high-thrust plumes and bow shock triple-points. Solutions for the 1E nozzle configuration were steady. Conversely, a subset of the 1F test conditions were unsteady and exhibited periodic, non-sinsoidal expansions and contractions of the streamwise-oriented plume, resulting in unsteady aerodynamic loads on the vehicle.

Supersonic Retropropulsion↗

Comparison of OVERFLOW Computational and Experimental Results for a Blunt Mars Entry Vehicle Concept During Supersonic Retropropulsion

Simulations of supersonic retropropulsion (SRP) flow over a Hypersonic Inflatable Aerodynamic Decelerator (HIAD) blunt-body vehicle were performed using the Overflow Computational Fluid Dynamics (CFD) solver. Simulation conditions and geometry were designed to match specific test runs in the Descent System Study (DSS) testing campaign. The relative accuracy of simulation predictions are assessed by direct comparison to experimental data. Computational predictions of the SRP flowfield and bow shock shape are compared to experimental schlieren images. Comparisons of the model surface pressure environment are presented for unsteady and static discrete tap data as well as time-averaged Pressure-Sensitive Paint (PSP) data.

Supersonic Retropropulsion↗

Comparison of OVERFLOW Computational and Experimental Results for a Blunt Mars Entry Vehicle Concept during Supersonic Retropropulsion

Simulations of unsteady supersonic retropropulsion (SRP) flow over a Hypersonic Inflatable Aerodynamic Decelerator (HIAD) blunt-body vehicle were performed using the OVERFLOW Computational Fluid Dynamics (CFD) solver. High-fidelity flow solver techniques, including Detached Eddy Simulation (DES) turbulence modeling and Adaptive Mesh Refinement (AMR), were employed to obtain improved realism in CFD predictions. Simulation conditions and geometry configurations were designed to match specific runs in the Descent System Study (DSS) wind tunnel testing (WTT) campaign. The accuracy of each simulation is assessed by direct comparison to experimental data. Comparisons of computational predictions of the SRP flowfield and bow shock shape to experimental schlieren imaging show reasonable prediction of mean shock shape, with approximately 10% similarity in shock standoff distance for selected conditions, as well as similarity in local, time-varying fluctuations of the shock-plume interaction. Comparisons of discrete measurements of surface pressure coefficient (Cp) indicate CFD accuracy within approximately 10% of the experiment across the majority of the model heatshield, with larger variations at some of the heatshield edge locations with stronger flow unsteadiness. Simulated unsteadiness of these chaotic flows, which were highly dynamic and multi-modal, was shown to be within 20-40% of experimentally-measured pressure standard deviation (SD) for the majority of the sampled locations.

Supersonic Retropropulsion↗

Comparison of OVERFLOW Computational and Experimental Results for a Blunt Mars Entry Vehicle Concept during Supersonic Retropropulsion

Simulations of unsteady supersonic retropropulsion (SRP) flow over a Hypersonic Inflatable Aerodynamic Decelerator (HIAD) blunt-body vehicle were performed using the OVERFLOW Computational Fluid Dynamics (CFD) solver. High-fidelity flow solver techniques, including Detached Eddy Simulation (DES) turbulence modeling and Adaptive Mesh Refinement (AMR), were employed to obtain improved realism in CFD predictions. Simulation conditions and geometry configurations were designed to match specific runs in the Descent System Study (DSS) wind tunnel testing (WTT) campaign. The accuracy of each simulation is assessed by direct comparison to experimental data. Comparisons of computational predictions of the SRP flowfield and bow shock shape to experimental schlieren imaging show reasonable prediction of mean shock shape, with approximately 10% similarity in shock standoff distance for selected conditions, as well as similarity in local, time-varying fluctuations of the shock-plume interaction. Comparisons of discrete measurements of surface pressure coefficient (Cp) indicate CFD accuracy within approximately 10% of the experiment across the majority of the model heatshield, with larger variations at some of the heatshield edge locations with stronger flow unsteadiness. Simulated unsteadiness of these chaotic flows, which were highly dynamic and multi-modal, was shown to be within 20-40% of experimentally-measured pressure standard deviation (SD) for the majority of the sampled locations.

Supersonic Retropropulsion↗

Overview of the 6 Meter HIAD Inflatable Structure and Flexible TPS Static Load Test Series

To support NASAs long term goal of landing humans on Mars, technologies which enable the landing of heavy payloads are being developed. Current entry, decent, and landing technologies are not practical for this class of payloads due to geometric constraints dictated by current launch vehicle fairing limitations. Therefore, past and present technologies are now being explored to provide a mass and volume efficient solution to atmospheric entry, including Hypersonic Inflatable Aerodynamic Decelerators (HIADs). At the beginning of 2014, a 6m HIAD inflatable structure with an integrated flexible thermal protection system (TPS) was subjected to a static load test series to verify the designs structural performance. The 6m HIAD structure was constructed in a stacked toroid configuration using nine inflatable torus segments composed of fiber reinforced thin films, which were joined together using adhesives and high strength textile woven structural straps to help distribute the loads throughout the inflatable structure. The 6m flexible TPS was constructed using multiple layers of high performance materials to protect the inflatable structure from heat loads that would be seen during atmospheric entry. To perform the static load test series, a custom test fixture was constructed. The fixture consisted of a structural tub rim with enough height to allow for displacement of the inflatable structure as loads were applied. The bottom of the tub rim had an airtight seal with the floor. The centerbody of the inflatable structure was attached to a pedestal mount as seen in Figure 1. Using an impermeable membrane seal draped over the test article, partial vacuum was pulled beneath the HIAD, resulting in a uniform static pressure load applied to the outer surface. During the test series an extensive amount of instrumentation was used to provide many data sets including: deformed shape, shoulder deflection, strap loads, cord loads, inflation pressures, and applied static load.In this overview, the 6m HIAD static load test series will be discussed in detail, including the 6m HIAD inflatable structure and flexible TPS design, test setup and execution, and finally initial results and conclusions from the test series.

inflatable aerodynamic decelerator↗

Overview of the 6m HIAD Inflatable Structure and Flexible TPS Static Load Test Series

To support NASAs long term goal of landing humans on Mars, technologies which enable the landing of heavy payloads are being developed. Current entry, decent, and landing technologies are not practical for this class of payloads due to geometric constraints dictated by current launch vehicle fairing limitations. Therefore, past and present technologies are now being explored to provide a mass and volume efficient solution to atmospheric entry, including Hypersonic Inflatable Aerodynamic Decelerators (HIADs). At the beginning of 2014, a 6m HIAD inflatable structure with an integrated flexible thermal protection system (TPS) was subjected to a static load test series to verify the designs structural performace. The 6m HIAD structure was constructed in a stacked toroid configuration using nine inflatable torus segments composed of fiber reinforced thin films, which were joined together using adhesives and high strength textile woven structural straps to help distribute the loads throughout the inflatable structure. The 6m flexible TPS was constructed using multiple layers of high performance materials to protect the inflatable structure from heat loads that would be seen during atmospheric entry. To perform the static load test series, a custom test fixture was constructed. The fixture consisted of a structural tub rim with enough height to allow for displacement of the inflatable structure as loads were applied. The bottom of the tub rim had an airtight seal with the floor. The centerbody of the inflatable structure was attached to a pedestal mount as seen in Figure 1. Using an impermeable membrane seal draped over the test article, partial vacuum was pulled beneath the HIAD, resulting in a uniform static pressure load applied to the outer surface. During the test series an extensive amount of instrumentation was used to provide many data sets including: deformed shape, shoulder deflection, strap loads, cord loads, inflation pressures, and applied static load.In this overview, the 6m HIAD static load test series will be discussed in detail, including the 6m HIAD inflatable structure and flexible TPS design, test setup and execution, and finally initial results and conclusions from the test series.

TPS↗

ELECTRICAL SHORTING OF THERMOCOUPLES IN ATMOSPHERIC ENTRY APPLICATIONS

The Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) will test Hyper-sonic Inflatable Aerodynamic Decelerator (HIAD) technology. Temperature measurements are taken across the vehicle to address a Level 1 mission requirement regarding performance of the Flexible Thermal Protection System (F-TPS). Temperature measurements are made using dozens of thermocouples (TCs) embedded within the F-TPS at different depths and various locations shown in Figure 1.

Cole D Kazemba↗

LOFTID Heat Flux Gauge Calibration: What is Truth?

The Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) is a demonstration of Hypersonic Inflatable Aerodynamic Decelerator (HIAD) technology, which may enable the delivery of heavy payloads to Mars, Venus, and Titan, as well as return to Earth. Unlike rigid aeroshells that are constrained by the size of the rocket’s shroud, inflatable aeroshells can be deployed to a much larger scale, thus allowing a spacecraft to begin its deceleration earlier and experience less heating. On LOFTID, there will be 4 total heat flux gauges (HFG) with a range of 70 W/cm2 and 1 radiometer with a range of 3 W/cm2, arranged as shown in Fig. 1. Both the radiometer and total HFGs are Schmidt-Boelter gauges purchased from an external vendor. Radiative calibrations were performed in-house at NASA Ames’ Sensors and TPS Advanced Research Laboratories (STAR Labs) before and after environmental testing to investigate how the testing affected the sensors' response. Additional rounds of radiative calibration at STAR Labs were also performed in order to investigate the large uncertainties associated with these tests. For example, a survey of multiple calibration facilities concluded that the uncertainty within a given facility was +/-3% [1]. An additional NIST study that calibrated heat flux gauges at 7 different facilities also found the variation in calibration coefficients to be up to ~3% within a given facility, but up to 15% between facilities, suggesting systematic differences between test setups [2]. Finally, the response of heat flux gauges to radiative versus convective heat flux has shown to differ by up to 20% [3],[4]. Because the heat flux gauges on LOFTID will predominantly experience convective heat flux during flight, a convective calibration study was performed at Boeing's Large-Core Arc Tunnel (LCAT) facility. Radiative Calibration Procedure The calibrations performed at STAR Labs utilize a quartz lamp bank (QLB) that provides a maximum heat flux of 50 W/cm2, which bounds the expected LOFTID flight environment. The calibration involves exposing a water-cooled Gardon gauge (reference) and then the unit-under-test (UUT) to 5 different heat fluxes multiple times for 10 seconds each, and then calculating a linear fit. The test setup is shown in Fig. 2. The total HFGs were calibrated at STAR Labs 3 times, denoted as STAR 1 (before environmental testing), STAR 2 (after protoflight vibration and thermal-vacuum testing), and STAR 3 (no change from previous test). All 8 flight-lot total HFGs showed a decrease in full-scale output from STAR 1 to STAR 2 by between 0.5% and 10. The first portion of this investigation was to determine whether the change could be due to differences in temperature between the two calibration runs. A typical linear fit to the calibration data was performed using Eq. 1 where q’ is the heat flux in W/cm2, c is the calibration coefficient, and mV is the sensor output. To account for temperature, the data were fit to a nonlinear function that included both the sensor output (mV) and the temperature from the thermocouple embedded inside the HFG near the surface (T): q'=mV/(c1* T + c0}. The residuals between the fits and the actual data points were calculated for every point, and proven to be much smaller for the temperature-compensated fits than for the linear fits for all sensors. An example is shown in Fig. 3. When the temperature-compensated fits from STAR 1 were applied to the STAR 2 data, the residuals did not improve, suggesting that the change in sensitivity between these two calibration runs was not due to temperature. A third round of calibration (STAR 3) was conducted to further address the temperature dependence of the total HFGs, and the resulting sensitivities matched closely to STAR 2 (within 2%). Temperature-compensated calibration curves were once again fit to the data. In this case, when the temperature-compensated fits from STAR 3 were applied to STAR 2 data, the residuals between the fits and STAR 2 data were much lower than the residuals due to the linear fits. This suggests that the changes seen between STAR 1 and STAR 2 were likely due to actual changes in the sensors caused by the environmental testing between the two calibrations. A modification of the original calibration process, in which the UUT was exposed to each heat flux for just 3 seconds (instead of 10) to reduce the temperature increase during the test, was additionally performed on several of the HFGs. In general, the sensitivities were 1-1.5% lower than from the 10-second tests, but the temperatures were also significantly lower. When the temperature-compensated fits from the 10-second tests were applied to the 3-second test data, the residuals were greatly improved than when just using the linear fits, further suggesting that the temperature-compensated fits may lead to better accuracy than the linear fits in flight. Convective Calibration The second portion of this study was to create a mapping between the radiative and convective calibration coefficients. The majority of the heating during flight will be convective, so it is important to understand how the HFG response differs under these conditions. However, there are no standardized methods for convective calibration [5]. Because the TPS aerothermal response models were validated at LCAT, the same facility was chosen for convective calibration of two of the total HFGs (Fig. 4). Preliminary results showed that the full-scale output was 3% and 8% higher in convective heat flux as compared to radiative heat flux. However, tunnel variation may have contributed to noise and uncertainty in the measurements, and more testing and analysis remains to be done. Scope of Presentation The presentation will include an overview of the changes seen in HFG calibration before and after environmental testing, differences between radiative and convective calibrations, the modeling work done to aid in understanding the sensor response to varying environments, and recommended future work.

H S Alpert↗

Post-Flight Quantification of LOFTID Aeroshell Deflection Using Feature Tracking

The Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) was a flight demonstration of the Hypersonic Inflatable Aerodynamic Decelerator (HIAD) technology, which has the potential to enable delivery of heavy payloads to Mars, Venus, and Titan, as well as return to Earth. Unlike rigid aeroshells that are constrained by the diameter of the launch vehicle shroud, inflatable aeroshells can be deployed to a much larger drag area, thus allowing a more massive spacecraft to begin its deceleration at higher altitudes and experience less heating. On November 10, 2022, the LOFTID reentry vehicle launched aboard a United Launch Alliance Atlas V rocket to low-Earth orbit. The aeroshell was inflated to its full 6-meter diameter, and the vehicle then successfully re-entered the atmosphere, landing in the Pacific Ocean. The aeroshell was composed of seven tori bound together by high strength straps to create a 70-degree half-angle sphere-cone, and the forebody was covered with a flexible thermal protection system (FTPS) (Fig. 1). The centerbody of the vehicle housed six visual cameras. Each camera was made up of 1920 x 1080 pixels and had a field-of-view (FOV) of 85.4° x 55.6°, resulting in a resolution of less than 0.1" at all locations on the aftbody side of the aeroshell. The approximate locations of the cameras and their associated FOVs is shown in Fig. 2. The high loads experienced during flight resulted in the cone of the aeroshell deflecting. This behavior was seen during the static load testing of the aeroshell in May 2021, in which loads ranging from 1,000 to 20,000 lbf were applied, and deflections of up to ~1.7° were observed. The LOFTID team was interested in estimating the deflection of the aeroshell during the its entry into Earth's atmosphere. Before launch, 1"-diameter black circles were drawn on select structural straps for tracking with the visual cameras; the change in position of these features could then be used to calculate aeroshell deflection angle.

Hannah S. Alpert↗

Post-Flight Quantification of LOFTID Aeroshell Deflection Using Feature Tracking

The Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) was a flight demonstration of the Hypersonic Inflatable Aerodynamic Decelerator (HIAD) technology, which has the potential to enable delivery of heavy payloads to Mars, Venus, and Titan, as well as return to Earth. Unlike rigid aeroshells that are constrained by the diameter of the launch vehicle shroud, inflatable aeroshells can be deployed to a much larger drag area, thus allowing a more massive spacecraft to begin its deceleration at higher altitudes and experience less heating. On November 10, 2022, the LOFTID reentry vehicle launched aboard a United Launch Alliance Atlas V rocket to low-Earth orbit. The aeroshell was inflated to its full 6-meter diameter, and the vehicle then successfully re-entered the atmosphere, landing in the Pacific Ocean. The aeroshell was composed of seven tori bound together by high strength straps to create a 70-degree half-angle sphere-cone, and the forebody was covered with a flexible thermal protection system (FTPS) (Fig. 1). The centerbody of the vehicle housed six visual cameras. Each camera was made up of 1920 x 1080 pixels and had a field-of-view (FOV) of 85.4° x 55.6°, resulting in a resolution of less than 0.1" at all locations on the aftbody side of the aeroshell. The approximate locations of the cameras and their associated FOVs is shown in Fig. 2. The high loads experienced during flight resulted in the cone of the aeroshell deflecting. This behavior was seen during the static load testing of the aeroshell in May 2021, in which loads ranging from 1,000 to 20,000 lbf were applied, and deflections of up to ~1.7° were observed. The LOFTID team was interested in estimating the deflection of the aeroshell during the its entry into Earth's atmosphere. Before launch, 1"-diameter black circles were drawn on select structural straps for tracking with the visual cameras; the change in position of these features could then be used to calculate aeroshell deflection angle.

Hannah S. Alpert↗

Summary of the Second High-Altitude, Supersonic Flight Dynamics Test for the LDSD Project

NASA’s Low-Density Supersonic Decelerator Project is developing and testing the next generation of supersonic aerodynamic decelerators for planetary entry. A key element of that development is the testing of full-scale articles in conditions relevant to their intended use, primarily in the tenuous Mars atmosphere. To achieve this testing, the LDSD project developed a new test architecture for the qualification of their supersonic parachute. A large, helium filled scientific balloon is used to hoist a 4.7 m blunt body test vehicle to an altitude of approximately 32 kilometers. The test vehicle is released from the balloon, spun up for gyroscopic stability, and accelerated to over four times the speed of sound and an altitude of 50 kilometers using a large solid rocket motor. Once at those conditions, the vehicle is despun and the test period begins.

Clark, Ian↗

The Viking decelerator system - An overview.

The Viking mission to place an instrumented lander on Mars in 1976 includes an aerodynamic decelerator as part of the landing sequence. Development of the decelerator, a single-stage mortared disk-gap-band parachute, began in 1965 for the Voyager project and culminated in the flight qualification of the decelerator system for the Viking mission in 1972. This paper summarizes the research, development, and qualification effort. The special operating conditions and the constraints imposed by the Viking mission and the Mars atmosphere, their effects on the decelerator system, and the solution of the resulting technical problems are briefly described.

Gillis, C. L.↗

Thermophysical and Optical Properties of Materials Considered for Use on the LDSD Test Vehicle

In June 2014, the first of multiple flights in the Low Density Supersonic Decelerator (LDSD) technology development program took place and successfully demonstrated a Supersonic Inflatable Aerodynamic Decelerator (SIAD) in Mars-like conditions. Although the primary goal of the technology program was the development of new decelerators for landing heavier payloads on Mars, the low-cost thermal design of the test vehicle was only possible through the innovative use of a combination of both commercial off the shelf (COTS) and aerospace grade materials. As a result, numerous thermophysical and optical property measurements were undertaken to characterize material candidates before the final material selection was made. This paper presents thermophysical and optical property measurements performed over the course of the LDSD test vehicle development, including those not ultimately selected for use on the vehicle. These properties are compared and contrasted with the existing measurements available in previous literature.

Redmond, Matthew↗