Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Accelerated Aging of PV Cables - The Development of Methods Towards Combined-Accelerated Stress Testing

PV cables allow the collection and distribution of electricity from modules to the energy grid. Durable cabling allows continuous operation of PV installations. Cables with a life less than that of the modules must be replaced - reducing electricity generation and adding to the system operating expense. We have examined the durability of a variety of representative cable samples using artificial UV weathering (IEC TS 62788-7-2) and combined accelerated stress testing (C-AST). Jackets in this study include PV-rated (polyolefin), building wire (PVC/PA), and multi-conductor (rubber, as in PV trackers), with some examples of black and red cables. Characterizations at read points include appearance (camera and optical microscope), surface roughness (linear profilometry), instrumented indentation, surface morphology (SEM), chemical composition (EDS), thermal decomposition (TGA), phase transition (DSC), crystalline structure (WAXS), and polymer chemical structure (FTIR). Complimentary examinations confirm damage to the external and interior layer(s) of less durable samples, including changes in morphology (e.g., cracking), chemistry (e.g., oxidation), structure, and mechanical performance (e.g., through-thickness modulus and hardness). The results may be generally compared to other examples from the field (PV installations) or after accelerated testing (IEC 61215). The methods in this study are presently being applied in a follow-on C-AST study, incorporating both dynamic and kinematic fixtures.

balance of systems↗

Modular Accelerator Robotics Framework Implementation For Accelerator Inspection

Accelerator tunnels, such as the ones at Fermilab, remain highly radioactive after beam shutoff due to induced radiation from the beam. This residual radiation creates a hazardous environment for manual inspection and repair of beamline components. To minimize worker radiation dose and reduce beam downtime, the AD Robotics Initiative previously built a fleet of low-cost custom mobile robots. However, the custom Python sockets server-client architecture lacked standardization, causing development delays and complicating the integration of new sensors and actuators. Here, we developed a modular system using ROS2 and Docker to standardize the teleoperation and control interfaces. This system was validated by implementing a teleoperation controller with real-time, low-latency, and high-definition video feedback. The aim of this framework is for a new feature or even a robot to be integrated into the system simply by documenting the hardware configuration. Current integration of LiDAR, Odometry, and Depth Cameras provides the foundation for Simultaneous Localization and Mapping (SLAM) tasks. Finally, future work involves integration into the accelerator control system and the attachment of a 6 degree-of-freedom robotic arm for telemanipulation.

Rayyan Khana, M. [Unlisted, US, IL] (ORCID:0009000↗

Electron Accelerator Lattice Design for LHeC with Permanent Magnets

We present a new ’green energy’ approach to the Energy Recovery Linac (ERL) the future Electron Ion Collider at LHeC using single beam line made of very strong focusing combined function permanent magnets and the Fixed Field Alternating Linear Gradient (FFA-LG) principle. We are basing our design on recent very successful commissioning results of the Cornell University and Brookhaven National Laboratory ERL Test Accelerator-CBETA.

Trbojevic, D.↗

The EIC accelerator: design highlights and project status

The design of the electron-ion collider (EIC) at Brookhaven National Laboratory is well underway, aiming at a peak electron-proton luminosity of 10e+34 cm^-1·sec^-1. This high luminosity, the wide center-of-mass energy range from 29 to 141 GeV (e-p) and the high level of polarization require innovative solutions to maximize the performance of the machine, which makes the EIC one of the most challenging accelerator projects to date. The complexity of the EIC will be discussed, and the project status and plans will be presented.

43 PARTICLE ACCELERATORS↗

Machine Learning Accelerated First-Principles Study of the Hydrodeoxygenation of Propanoic Acid

The complex reaction network of catalytic biomass conversions often involves hundreds of surface intermediates and thousands of reaction steps, greatly hindering the rational design of metal catalysts for these conversions. Here, we present a framework of machine learning (ML)-accelerated first-principles studies for the hydrodeoxygenation (HDO) of propanoic acid over transition metal surfaces. The microkinetic model (MKM) is initially parametrized by ML-predicted energies and iteratively improved by identifying the rate-determining species and steps (RDS), computing their energies by density functional theory (DFT), and reparameterizing the MKM until all the RDS are computed by DFT. The Gaussian process (GP) model performs significantly better than the linear ridge regression model for predicting both the adsorption free energies and transition state free energies. Parameterized with energies from the GP model, only 5–20% of the full reaction network has to be computed by DFT for the MKM to possess DFT-level accuracy for the TOF and dominant reaction pathway. While the linear ridge regression model performs worse than the GP model, its performance is greatly improved when only transition states are predicted by the regression model and adsorption energies are computed by DFT. Overall, we find that a high accuracy in adsorption free energies is more important for a reliable MKM than a high accuracy in TS free energies. Lastly, based on the GP model with GOH and GCHCHCO as catalyst descriptors, we build two-dimensional volcano plots in activity and selectivity that can help design promising alloy catalysts for HDO reactions of organic acids.

adsorption↗

Accelerated test techniques for micro-circuits: Evaluation of high temperature (473 k - 573 K) accelerated life test techniques as effective microcircuit screening methods

The application of high temperature accelerated test techniques was shown to be an effective method of microcircuit defect screening. Comprehensive microcircuit evaluations and a series of high temperature (473 K to 573 K) life tests demonstrated that a freak or early failure population of surface contaminated devices could be completely screened in thirty two hours of test at an ambient temperature of 523 K. Equivalent screening at 398 K, as prescribed by current Military and NASA specifications, would have required in excess of 1,500 hours of test. All testing was accomplished with a Texas Instruments' 54L10, low power triple-3 input NAND gate manufactured with a titanium- tungsten (Ti-W), Gold (Au) metallization system. A number of design and/or manufacturing anomalies were also noted with the Ti-W, Au metallization system. Further study of the exact nature and cause(s) of these anomalies is recommended prior to the use of microcircuits with Ti-W, Au metallization in long life/high reliability applications. Photomicrographs of tested circuits are included.

Johnson, G. M.↗