Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARGON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Unpaired image translation to mitigate domain shift in liquid argon time projection chamber detector responses

Deep learning algorithms often are developed and trained on a training dataset and deployed on test datasets. Any systematic difference between the training and a test dataset may severely degrade the final algorithm performance on the test dataset—what is known as the domain shift problem . This issue is prevalent in many scientific domains where algorithms are trained on simulated data but applied to real-world datasets. Typically, the domain shift problem is solved through various domain adaptation (DA) methods. However, these methods are often tailored for a specific downstream task, such as classification or semantic segmentation, and may not easily generalize to different tasks. This work explores the feasibility of using an alternative way to solve the domain shift problem that is not specific to any downstream algorithm. The proposed approach relies on modern Unpaired Image-to-Image (UI2I) translation techniques, designed to find translations between different image domains in a fully unsupervised fashion. In this study, the approach is applied to a domain shift problem commonly encountered in Liquid Argon Time Projection Chamber (LArTPC) detector research when seeking a way to translate samples between two differently distributed LArTPC detector datasets deterministically. This translation allows for mapping real-world data into the simulated data domain where the downstream algorithms can be run with much less domain-shift-related performance degradation. Conversely, using the translation from the simulated data to a real-world domain can increase the realism of the simulated dataset and reduce the magnitude of any systematic uncertainties. To evaluate the quality of the translations, we use both pixel-wise metrics and a downstream task to measure the effectiveness of UI2I methods for mitigating the domain shift problem. We adapted several popular UI2I translation algorithms to work on scientific data and demonstrated the viability of these techniques for solving the domain shift problem with LArTPC detector data. To facilitate further development of DA techniques for scientific datasets, the ‘Simple Liquid-Argon Track Samples’ dataset used in this study is also published.

97 MATHEMATICS AND COMPUTING↗

Impact of reverse flow induced by a sawtooth anode on the performance of an argon Hall thruster

This study reports the performance comparison of the RAIJIN-66 TAL-type Hall thruster with argon propellant, using two hollow anode designs, one with a simple straight shape and another one with a sawtooth shape. Simulations of the rarefied gas in the sawtooth hollow anode region suggest a successful reversal of the direction of neutral particle flow, with an average increase in the neutral particle density by 15.5% when compared to the straight-shaped hollow anode. This contributes to the improvement in performance across a range of discharge voltages that was measured experimentally. When the thruster is operated with a discharge voltage of 150 V and a flow rate of 70 SCCM, the propellant utilization efficiency with the straight anode is 14%, while with the sawtooth anode it is 25.1%. The anode efficiency reaches in the vicinity of 15% with the sawtooth anode in high voltage conditions, exceeding the efficiencies achieved with the straight anode in the same operating conditions. The optimal magnetic field condition for argon operation and the tuning parameters of the sawtooth anode design for RAIJIN-66 are also discussed.

Satpathy, Dibyesh [Univ. of Tokyo (Japan)] (ORCID:↗

Non-intrusive measurement of magnetic field strengths in a low-pressure argon plasma using quantum beat spectroscopy

Abstract Accurate measurement of magnetic field strengths is critical in many plasma environments, ranging from astrophysical systems to fusion energy research. In this work, a non-perturbative laser-based optical diagnostic known as quantum beat spectroscopy is demonstrated to be good alternative for measuring the magnetic field strength in low-pressure laboratory plasmas. The technique is investigated using both ns and fs pulsed lasers in an argon plasma. Preliminary results for a helium plasma are also given. Zeeman-split J = 1 electron states with transitions from metastable states were identified and tested for neutral argon ( 2 P 1 / 2 o ) 4 p 2 [ 1 / 2 ] and neutral helium 1 s 3 p 1 P 1 o . Magnetic fields are measured with sub-Gauss precision at near single laser pulse acquisition rates.

Gilbert, Tyler J. (ORCID:0000000160400119)↗

Dynamics of argon metastables in Ar–CH 4 radio frequency capacitively-coupled plasma: real-time monitoring with neural network-augmented broadband optical emission spectroscopy

In moderate-pressure radio frequency (RF) capacitively coupled plasmas generated in argon–methane mixtures, the density of argon metastable atoms (Ar 1 s 5 ) exhibits a non-monotonic dependence on methane (CH 4 ) concentration. Laser-induced fluorescence (LIF) was used to measure and compare local Ar 1 s 5 densities in Ar and Ar–CH 4 plasmas at 2.6 Torr and RF powers of 17–117 W. The addition of 1% CH 4 increases the metastable density, and 2% CH 4 triggers a strong depletion by an order of magnitude, compared to 1% CH 4 case. This non-monotonic behavior demonstrates the sensitivity of metastable populations to small gas admixtures, which is critical for processes where metastables drive precursor dissociation. For real-time monitoring of metastable population, broadband optical emission spectroscopy (OES) is augmented with a feedforward neural network (NN) to predict Ar s1 5 densities from spectral features. When trained on LIF data, the NN replicates the absolute densities and the dynamic trends of Ar 1 s 5 density variation. The NN-augmented broadband OES approach can be used as a simple and cost-effective tool for tracking Ar metastables in Ar-rich plasmas, facilitating industrial-scale optimization.

Yatom, Shurik [Princeton Plasma Physics Laboratory↗

The track-length extension fitting algorithm for energy measurement of interacting particles in liquid argon TPCs and its performance with ProtoDUNE-SP data

This paper introduces a novel track-length extension fitting algorithm for measuring the kinetic energies of inelastically interacting particles in liquid argon time projection chambers (LArTPCs). The algorithm finds the most probable offset in track length for a track-like object by comparing the measured ionization density as a function of position with a theoretical prediction of the energy loss as a function of the energy, including models of electron recombination and detector response. The algorithm can be used to measure the energies of particles that interact before they stop, such as charged pions that are absorbed by argon nuclei. The algorithm's energy measurement resolutions and fractional biases are presented as functions of particle kinetic energy and number of track hits using samples of stopping secondary charged pions in data collected by the ProtoDUNE-SP detector, and also in a detailed simulation. Additional studies describe the impact of the dE/dx model on energy measurement performance. The method described in this paper to characterize the energy measurement performance can be repeated in any LArTPC experiment using stopping secondary charged pions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flow and thermal modelling of the argon volume in the DarkSide-20k TPC

The DarkSide-20k dark matter experiment, currently under construction at LNGS, features a dual-phase time projection chamber (TPC) with a ∼ 50 t argon target from an underground well. At this scale, it is crucial to optimise the argon flow pattern for efficient target purification and for fast distribution of internal gaseous calibration sources with lifetimes of the order of hours. To this end, we have performed computational fluid dynamics simulations and heat transfer calculations. The residence time distribution shows that the detector is well-mixed on time-scales of the turnover time (∼ 40 d). Notably, simulations show that despite a two-order-of-magnitude difference between the turnover time and the half-life of 83m Kr of 1.83 h, source atoms have the highest probability to reach the centre of the TPC 13 min after their injection, allowing for a homogeneous distribution before undergoing radioactive decay. We further analyse the thermal aspects of dual-phase operation and define the requirements for the formation of a stable gas pocket on top of the liquid. We find a best-estimate value for the heat transfer rate at the liquid-gas interface of 62 W with an upper limit of 144 W and a minimum gas pocket inlet temperature of 89 K to avoid condensation on the acrylic anode. This study also informs the placement of liquid inlets and outlets in the TPC. The presented techniques are widely applicable to other large-scale, noble-liquid detectors.

47 OTHER INSTRUMENTATION↗

Measurement of single- and double-differential cross sections for mesonless charged-current muon neutrino interactions on argon with final-state protons using the MicroBooNE detector

Charged-current neutrino interactions with final states containing zero mesons and at least one proton are of high interest for current and future accelerator-based neutrino oscillation experiments. Using the Booster Neutrino Beam and the MicroBooNE detector at Fermi National Accelerator Laboratory, we have obtained the first double-differential cross-section measurements of this channel for muon neutrino scattering on an argon target with a leading proton momentum threshold of 0.25 GeV/𝑐. We also report a flux-averaged total cross section of 𝜎 = (11.8±1.2) × 10 −38 cm 2 /Ar and several single-differential measurements which extend and improve upon previous results. Statistical and systematic uncertainties are quantified with a full treatment of correlations across 359 kinematic bins, including correlations between distributions describing different observables. The resulting dataset provides the most detailed information obtained to date for testing models of mesonless neutrino-argon scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Event-by-Event Identification of Cherenkov Radiation from Sub-Mev Particles in Liquid Argon

This Letter reports the event-by-event observation of Cherenkov light from sub-MeV electrons in a high scintillation light-yield liquid argon detector by the coherent CAPTAIN-Mills (CCM) experiment. The CCM200 detector, located at Los Alamos National Laboratory, instruments seven tons (fiducial volume) of liquid argon with 200 eight-inch photomultiplier tubes, 80% of which are coated in a wavelength-shifting material and the remaining 20% are uncoated. In the prompt time region of an event, defined as - 6 ≤ t < 0 ns relative to the event start time t = 0 , the uncoated photomultiplier tubes are primarily sensitive to visible Cherenkov photons. Using gamma rays from a Na 22 source for production of sub-MeV electrons, we isolated prompt Cherenkov light with > 5 σ confidence and developed a selection to obtain a low-background electromagnetic sample. This is the first event-by-event observation of Cherenkov photons from sub-MeV electrons in a high-yield scintillator detector and represents a milestone in low-energy particle detector development.

Aguilar-Arevalo, A. A. [UNAM, Mexico]↗

Observation and origin of multi-THz quantum beats in superfluorescent emission from argon

We report observation of multi-THz quantum beats in the amplitude of superfluorescence in pure argon gas, using a time delayed 780-nm probe beam that interrogates the relevant population densities. The superfluorescence is induced by three-photon absorption of an ultrashort 260.5-nm laser pulse that creates coherent and coupled populations in multiple closely spaced 3⁢d and 5⁢s Ar levels. Argon pressure and pump laser focusing parameters are seen to modify the frequency of the quantum beats, which is attributed to the absorption of the self-generated, nonresonant third harmonic of the pump from Ar near the zero of the real part of the overlapping linear susceptibilities of the closely spaced 3⁢d and 5⁢s excited states. The self-absorption of the phase-matched THG photons creates a coherent population of atoms which acts like an atomic excited state (3⁢ω-induced state). Furthermore, we have also observed a new two-step superfluorescent cascade that results from the population redistribution enabled by the 780-nm probe pulse between the 3⁢d'[5/2] 3 and the 3⁢ω-induced state and gives rise to a previously unknown transition that emits on 1587 nm.

74 ATOMIC AND MOLECULAR PHYSICS↗

First measurement of the total inelastic cross section of positively charged kaons on argon at energies between 5.0 and 7.5 GeV

ProtoDUNE Single-Phase (ProtoDUNE-SP) is a 770-ton liquid argon time projection chamber that operated in a hadron test beam at the CERN Neutrino Platform in 2018. We present a measurement of the total inelastic cross section of charged kaons on argon as a function of kaon energy using 6 and 7 GeV/𝑐 beam momentum settings. The flux-weighted average of the extracted inelastic cross section at each beam momentum setting was measured to be 380 ± 26 mbarns for the 6 GeV/𝑐 setting and 379 ± 35 mbarns for the 7 GeV/𝑐 setting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of Pion and Muon Nuclear Capture at Rest on Argon in the LArIAT Experiment

We report the measurement of the final-state products of negative pion and muon nuclear capture at rest on argon by the LArIAT experiment at the Fermilab Test Beam Facility. We measure a population of isolated MeV-scale energy depositions, or blips, in 296 LArIAT events containing tracks from stopping low-momentum pions and muons. The average numbers of visible blips are measured to be 0.74 ± 0.19 and 1.86 ± 0.17 near muon and pion track endpoints, respectively. The 3.6⁢𝜎 statistically significant difference in blip content between muons and pions provides the first demonstration of a new method of pion-muon discrimination in neutrino liquid argon time projection chamber experiments. LArIAT Monte Carlo simulations predict substantially higher average blip counts for negative muon (1.22 ± 0.08) and pion (2.34 ± 0.09) nuclear captures. We attribute this difference to geant4’s inaccurate simulation of the nuclear capture process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity to low-mass WIMPs with an improved liquid argon ionization response model within the DarkSide program

Dark matter detection experiments using liquid argon rely on a precise characterization of the ionization response to nuclear recoils, especially in the keV energy range relevant for light dark matter interactions. In this work, we present a comprehensive analysis that combines new measurements from the ReD setup, part of the DarkSide experimental program, with calibration data from DarkSide-50, as well as results from the ARIS and SCENE experiments. These combined datasets enable improved constraints on atomic screening effects in the modeling of the ionization response of liquid argon to nuclear recoils. The analysis is performed within the Thomas-Imel recombination framework adopted in previous DarkSide studies, and is here further constrained by the inclusion of ReD data, which allow the screening function to be determined from calibration measurements. By including the updated ionization model into the DarkSide-50 analysis framework, we obtain stronger exclusion limits on low-mass weakly interacting massive particle (WIMP) interactions, setting new world-leading constraints in the 1 – 3 GeV / c 2 WIMP mass range. Finally, we recast the sensitivity projections for the upcoming DarkSide-20k detector, demonstrating a significantly enhanced discovery potential for low-mass dark matter candidates.

Acerbi, F. [Fond. Bruno Kessler, Trento]↗

Measurement of charged-current muon neutrino-argon interactions without pions in the final state using the MicroBooNE detector

We report a new measurement of flux-integrated differential cross sections for charged-current (CC) muon neutrino interactions with argon nuclei that produce no final-state pions (𝜈 𝜇 ⁢CC⁢0⁢𝜋). These interactions are of particular importance as a topologically defined signal dominated by quasielasticlike interactions. This measurement was performed with the MicroBooNE liquid argon time projection chamber detector located at the Fermilab Booster Neutrino Beam and uses an exposure of 1.3 ×10 21 protons on target collected between 2015 and 2020. The results are presented in terms of single- and double-differential cross sections as a function of the final-state muon momentum and angle. The data are compared with widely used neutrino event generators. We find good agreement with the single-differential measurements, while only a subset of generators are also able to adequately describe the data in double-differential distributions. This work facilitates comparison with Cherenkov detector measurements, including those located at the Booster Neutrino Be

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of Pion and Muon Nuclear Capture at Rest on Argon in the LArIAT Test Beam Experiment

LArIAT is a liquid argon time projection chamber (LArTPC) experiment in a test beam at Fermilab from 2015 to 2017 to understand and characterize interactions of particles in LAr which are commonly observed in neutrino-Ar final-states. Tracks for pions and muons in LArTPCs are difficult to differentiate since both particles exhibit very similar ionization profiles for muon and pion that stop in the TPC. We are exploring unique new particle discrimination capabilities by exploiting information from small, isolated ionization depositions, referred to as "blips", reconstructed near the endpoint of stopping tracks. These blips are formed by gammas emitted when an at-rest pion or muon captures on the argon nucleus. The relatively low beam energy provided by LArIAT makes it uniquely suited for performing this demonstration. In this poster, we present an overview of event candidate selection, blip reconstruction, and background subtraction corresponding to our signal of interest, nuclear captures of pions and muons at rest inside LArIAT's TPC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multi-Differential Charged Current $\nu_{\mu}$ - Argon Cross Section without Pions in the Final State Measurement in MicroBooNE

MicroBooNE, an 85-tonne liquid argon time projection chamber (LArTPC) detector is on-axis to the Booster Neutrino Beam (BNB) beamline facility at Fermi National Accelerator Laboratory. MicroBooNE is elucidating neutrino interactions with argon through cross-section measurements to refine interaction models and reduce uncertainties. In this poster, we present the status of the single and double multi-differential charged current (CC) cross section with zero pions in the final state (CC-0$\pi$) as a function of muon momentum ($0.1<p_\mu<2.0\,\mathrm{GeV/c}$) and the cosine of the muon angle ($-1<\cos\theta_\mu<1$). We present the details of the event selection and cross section extraction along with a set of tests using fake data to establish the robustness of the analysis methodology. We also discuss prospects for a future combined measurement with the Gd-H$_2$O target at the ANNIE experiment, to explore MicroBooNE’s proton multiplicity alongside ANNIE’s neutron multiplicity.

43 PARTICLE ACCELERATORS↗

New Measurement of Electron Neutrino Interactions on Argon in MicroBooNE

MicroBooNE, located at the Fermi National Accelerator Laboratory, is an 85-tonne liquid argon time-projection chamber designed to study neutrinos from the Booster Neutrino Beam and Neutrinos at the Main Injector (NuMI) beam. Understanding neutrino-nucleon interactions is essential for improving the accuracy of neutrino event generators, which are critical for modelling neutrino behaviour and interpreting data from oscillation experiments. The NuMI beam's high electron neutrino flux relative to its muon neutrino flux makes it particularly suited to probe these interactions. This poster presents new single-differential cross-section measurements of charged-current electron-neutrino interactions on argon with protons and no pions in the final state. These results use data from NuMI beam operations in both neutrino and antineutrino modes. Cross sections are reported as functions of key kinematic observables, including electron energy, total visible energy, and the opening angle between the electron and leading proton. Interaction rates as a function of proton multiplicity are also shown. These results are compared to theoretical predictions generated by widely used neutrino event generators.

Barnard, Abbey G. [Oxford U.] (ORCID:0000000161171↗

Measurement of cross sections for mesonless charged-current muon neutrino interactions on argon with and without protons at MicroBooNE

urrent and upcoming neutrino experiments at Fermilab will rely on liquid argon time projection chambers (LArTPCs) as the primary detector technology. To reach the ambitious precision required for their physics goals, a detailed understanding of neutrino-argon scattering must be achieved. For the present Short-Baseline Neutrino program, the dominant reaction channel is charged-current muon neutrino interactions leading to mesonless final states with and without protons. Using a large data set of neutrino interactions recorded by the MicroBooNE LArTPC detector at Fermilab, we report progress towards new measurements of differential cross sections in this channel. The analysis leverages multiple event reconstruction paradigms and observables specifically chosen to maximize sensitivity to nuclear effects of interest for improving neutrino scattering models. Related previous cross-section results from MicroBooNE and a preview of what to expect from the new analysis will both be featured in this presentation.

Liu, Liang [Fermilab]↗

LArCADe | Liquid Argon Charge Amplification Devices

The Liquid Argon Charge Amplification Devices (LArCADe) project is an R$\&$D effort aimed at developing instrumentation capable of lowering detection thresholds for ionization signatures in liquid and gaseous argon detectors and achieving O(100 $\mu$m) position resolution. The core concept is the use of sharp “tip arrays” that generate strong local electric-field enhancement, enabling charge amplification and collection with improved spatial resolution. A key physics motivation for this work is to enhance the experimental sensitivity of Coherent Elastic Neutrino-Nucleus Scattering (CEvNS) measurements to low-energy nuclear recoils by enabling spatially resolved charge reconstruction at reduced ionization thresholds, with the goal of achieving event-by-event energy reconstruction for interactions originating from localized accelerator or astrophysical neutrino sources. This poster will present the current status of the instrumentation R$\&$D, which leverages Fermilab’s Noble Liquid Test Facility and UC Santa Barbara’s Nanofabrication Facility, and will discuss the potential physics impact of this technology.

Antonakis, Alexander [UC, Santa Barbara]↗