Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “APEX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

SU-E-T-448: Heightened Apical Positivity of 2-Year Post-Radiotherapy Biopsies Is Not Related to Suboptimal Dosimetry

Purpose: Previous research has demonstrated that following radiation therapy for prostate cancer, there is a relative increase in positive biopsies in the apex versus the rest of the prostate. The increase could be due to: 1) Inter-fraction apex motion or deformation, 2) Intra-fraction apex motion or deformation, 3) Suboptimal dose coverage in the apex, 4) Tissue composition in the apex and/or 5) Prostate size. In this initial study, the potential for suboptimal dose coverage in the apex was assessed by splitting the prostate planning target volume into the apex (inferior third) and remainder. Methods: 69 patients were selected from 303 patients treated on a clinical radiotherapy trial for prostate cancer. These patients were selected as they had both a localized (sextant template) 2-year post-treatment biopsy and 3D dose information. Of these patients, 10 had positive biopsies in the apex, 8 in the remainder and 11 in both locations. For all patients, the following dosimetric data was acquired from the apex dose volume histogram: Dmean, Dmax, Dmin, D95% and V100%. Unpaired, one-tailed t-tests were used to test for statistical significance (p < 0.05) between all dosimetric parameters for patients with positive versus negative apical biopsies. Additionally, D95% for the apex was plotted against D95% of the remainder. Results: There was no statistical difference for the selected apical dosimetric parameters for patients with positive versus negative biopsies (p-values > 0.05). No correlation was found between D95% (normalized to the prescription dose) for the apex and remainder (R{sup 2} = 0.0116). Conclusion: No correlation was found between positive apical biopsy and suboptimal dosimetric coverage. Current research is looking into inter-fraction apex motion and deformation as a potential source of the increased apical failure using daily CBCT images.

60 APPLIED LIFE SCIENCES↗

Optimized Dose Distribution of Gammamed Plus Vaginal Cylinders

Endometrial carcinoma is the most common malignancy arising in the female genital tract. Intracavitary vaginal cuff irradiation may be given alone or with external beam irradiation in patients determined to be at risk for locoregional recurrence. Vaginal cylinders are often used to deliver a brachytherapy dose to the vaginal apex and upper vagina or the entire vaginal surface in the management of postoperative endometrial cancer or cervical cancer. The dose distributions of HDR vaginal cylinders must be evaluated carefully, so that clinical experiences with LDR techniques can be used in guiding optimal use of HDR techniques. The aim of this study was to optimize dose distribution for Gammamed plus vaginal cylinders. Placement of dose optimization points was evaluated for its effect on optimized dose distributions. Two different dose optimization point models were used in this study, namely non-apex (dose optimization points only on periphery of cylinder) and apex (dose optimization points on periphery and along the curvature including the apex points). Thirteen dwell positions were used for the HDR dosimetry to obtain a 6-cm active length. Thus 13 optimization points were available at the periphery of the cylinder. The coordinates of the points along the curvature depended on the cylinder diameters and were chosen for each cylinder so that four points were distributed evenly in the curvature portion of the cylinder. Diameter of vaginal cylinders varied from 2.0 to 4.0 cm. Iterative optimization routine was utilized for all optimizations. The effects of various optimization routines (iterative, geometric, equal times) was studied for the 3.0-cm diameter vaginal cylinder. The effect of source travel step size on the optimized dose distributions for vaginal cylinders was also evaluated. All optimizations in this study were carried for dose of 6 Gy at dose optimization points. For both non-apex and apex models of vaginal cylinders, doses for apex point and three dome points were higher for the apex model compared with the non-apex model. Mean doses to the optimization points for both the cylinder models and all the cylinder diameters were 6 Gy, matching with the prescription dose of 6 Gy. Iterative optimization routine resulted in the highest dose to apex point and dome points. The mean dose for optimization point was 6.01 Gy for iterative optimization and was much higher than 5.74 Gy for geometric and equal times routines. Step size of 1 cm gave the highest dose to the apex point. This step size was superior in terms of mean dose to optimization points. Selection of dose optimization points for the derivation of optimized dose distributions for vaginal cylinders affects the dose distributions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anatomic-Based Three-Dimensional Planning Precludes Use of Catheter-Delivered Contrast for Treatment of Prostate Cancer

Purpose: Retrograde urethrography is a standard method to identify the prostatic apex during planning for prostate cancer radiotherapy. This is an invasive and uncomfortable procedure. With modern three-dimensional computed tomography planning, we explored whether retrograde urethrography was still necessary to accurately identify the prostatic apex. Methods and Materials: Fifteen patients underwent computed tomography simulation with and without bladder, urethral, and rectal contrast. The prostatic base and apex were identified on both scans, using contrast and anatomy, respectively. The anatomic location of the prostatic apex as defined by these methods was confirmed in another 57 patients with postbrachytherapy imaging. Results: The prostatic base and apex were within a mean of 3.8 mm between the two scans. In every case, the beak of the retrograde urethrogram abutted the line drawn parallel to, and bisecting, the pubic bone on the lateral films. With these anatomic relationships defined, in the postbrachytherapy patients, the distance from the prostatic apex to the point at which the urethra traversed the pelvic floor was an average of 11.7 mm. On lateral films, we found that the urethra exited the pelvis an average of 16.6 mm below the posterior-most fusion of the pubic symphysis. On axial images, this occurred at a mean separation of the ischia of about 25 mm. Conclusion: With a knowledge of the anatomic relationships and modern three-dimensional computed tomography planning equipment, the prostatic apex can be easily and consistently identified, obviating the need to subject patients to retrograde urethrography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uveal Melanoma Treated With Iodine-125 Episcleral Plaque: An Analysis of Dose on Disease Control and Visual Outcomes

Purpose: To investigate, in the treatment of uveal melanomas, how tumor control, radiation toxicity, and visual outcomes are affected by the radiation dose at the tumor apex. Methods and Materials: A retrospective review was performed to evaluate patients treated for uveal melanoma with {sup 125}I plaques between 1988 and 2010. Radiation dose is reported as dose to tumor apex and dose to 5 mm. Primary endpoints included time to local failure, distant failure, and death. Secondary endpoints included eye preservation, visual acuity, and radiation-related complications. Univariate and multivariate analyses were performed to determine associations between radiation dose and the endpoint variables. Results: One hundred ninety patients with sufficient data to evaluate the endpoints were included. The 5-year local control rate was 91%. The 5-year distant metastases rate was 10%. The 5-year overall survival rate was 84%. There were no differences in outcome (local control, distant metastases, overall survival) when dose was stratified by apex dose quartile (<69 Gy, 69-81 Gy, 81-89 Gy, >89 Gy). However, increasing apex dose and dose to 5-mm depth were correlated with greater visual acuity loss (P=.02, P=.0006), worse final visual acuity (P=.02, P<.0001), and radiation complications (P<.0001, P=.0009). In addition, enucleation rates were worse with increasing quartiles of dose to 5 mm (P=.0001). Conclusions: Doses at least as low as 69 Gy prescribed to the tumor apex achieve rates of local control, distant metastasis–free survival, and overall survival that are similar to radiation doses of 85 Gy to the tumor apex, but with improved visual outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Factors Affecting Prostate Volume Estimation in Computed Tomography Images

The aim of this study was to investigate how apex-localizing methods and the computed tomography (CT) slice thickness affected the CT-based prostate volume estimation. Twenty-eight volunteers underwent evaluations of prostate volume by CT, where the contour segmentations were performed by three observers. The bottom of ischial tuberosities (ITs) and the bulb of the penis were used as reference positions to locate the apex, and the distances to the apex were recorded as 1.3 and 2.0 cm, respectively. Interobserver variations to locate ITs and the bulb of the penis were, on average, 0.10 cm (range 0.03-0.38 cm) and 0.30 cm (range 0.00-0.98 cm), respectively. The range of CT slice thickness varied from 0.08-0.48 cm and was adopted to examine the influence of the variation on volume estimation. The volume deviation from the reference case (0.08 cm), which increases in tandem with the slice thickness, was within {+-} 3 cm{sup 3}, regardless of the adopted apex-locating reference positions. In addition, the maximum error of apex identification was 1.5 times of slice thickness. Finally, based on the precise CT films and the methods of apex identification, there were strong positive correlation coefficients for the estimated prostate volume by CT and the transabdominal ultrasonography, as found in the present study (r > 0.87; p < 0.0001), and this was confirmed by Bland-Altman analysis. These results will help to identify factors that affect prostate volume calculation and to contribute to the improved estimation of the prostate volume based on CT images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Atomic-scale understanding of the electronic structure-crystal facets synergy of nanopyramidal CoPi/BiVO 4 hybrid photocatalyst for efficient solar water oxidation

The observation of a spontaneous electron enrichment at the apexes of bismuth vanadate (BiVO 4 ) nanopyramidal arrays is achieved by performing synchrotron-based angular dependent X-ray absorption spectroscopy. In accordance with density function theory calculations, the formation of (112) facets enriched apexes is proposed. Such intrinsically electron-enriched (112) facets at the apexes produce a potential facilitating the diffusion of photoexcited holes, which not only mitigates the recombination with the photoexcited electrons, but also provide an active reaction site for the photoassisted selective growth of cobalt phosphate (CoPi), a well known and highly active co-catalyst for water oxidation at the apex of BiVO 4 nanopyramids. Benefiting from the element-resolved properties of synchrotron-based X-ray spectroscopy, 3d electrons on the vanadium site are directly resolved by resonant inelastic X-ray scattering measurements. Due to this unique morphology, the charge at the apex is expected to induce a strong interaction with CoPi, as a result of the metal-to-ligand charge transfer spectroscopy feature observed from the cobalt site. Substantial evidences are collected by means of comprehensive soft X-ray spectroscopy techniques with high spectral resolution revealing the atomic-scale origin and the nature of the synergy as well as the strong correlation between its unique structural properties and the electronic structure of this novel highly-ordered hybrid photocatalyst and its significantly improved photoelectrochemical performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron-bombarded 〈110〉-oriented tungsten tips for stable tunneling electron emission

A clean tungsten (W) tip apex with a robust atomic plane is required for producing a stable tunneling electron emission under strong electric fields. Because a tip apex fabricated from a wire by aqueous chemical etching is covered by impurity layers, heating treatment in ultra-high vacuum is experimentally known to be necessary. However, strong heating frequently melts the tip apex and causes unstable electron emissions. We investigated quantitatively the tip apex and found a useful method to prepare a tip with stable tunneling electron emissions by controlling electron-bombardment heating power. Careful characterizations of the tip structures were performed with combinations of using field emission I–V curves, scanning electron microscopy, X-ray diffraction (transmitted Debye-Scherrer and Laue) with micro-parabola capillary, field ion microscopy, and field emission microscopy. Tips were chemically etched from (1) polycrystalline W wires (grain size ∼1000 nm) and (2) long-time heated W wires (grain size larger than 1 mm). Heating by 10-40 W (10 s) was found to be good enough to remove oxide layers and produced stable electron emission; however, around 60 W (10 s) heating was threshold power to increase the tip radius, typically +10 ± 5 nm (onset of melting). Further, the grain size of ∼1000 nm was necessary to obtain a conical shape tip apex.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proximity-dependent proteomics of the Chlamydia trachomatis inclusion membrane reveals functional interactions with endoplasmic reticulum exit sites

Chlamydia trachomatis is the most common bacterial sexually transmitted infection, responsible for millions of infections each year. Despite this high prevalence, the elucidation of the molecular mechanisms of Chlamydia pathogenesis has been difficult due to limitations in genetic tools and its intracellular developmental cycle. Within a host epithelial cell, chlamydiae replicate within a vacuole called the inclusion. Many Chlamydia –host interactions are thought to be mediated by the Inc family of type III secreted proteins that are anchored in the inclusion membrane, but their array of host targets are largely unknown. To investigate how the inclusion membrane proteome changes over the course of an infected cell, we have adapted the APEX system of proximity-dependent biotinylation. APEX is capable of specifically labeling proteins within a 20 nm radius in living cells. We transformed C. trachomatis to express the enzyme APEX fused to known inclusion membrane proteins, allowing biotinylation and pull-down of inclusion-associated proteins. Using quantitative mass spectrometry against APEX labeled samples, we identified over 400 proteins associated with the inclusion membrane at early, middle, and late stages of epithelial cell infection. This system was sensitive enough to detect inclusion interacting proteins early in the developmental cycle, at 8 hours post infection, a previously intractable time point. Mass spectrometry analysis revealed a novel, early association between C. trachomatis inclusions and endoplasmic reticulum exit sites (ERES), functional regions of the ER where COPII-coated vesicles originate. Pharmacological and genetic disruption of ERES function severely restricted early chlamydial growth and the development of infectious progeny. APEX is therefore a powerful in situ approach for identifying critical protein interactions on the membranes of pathogen-containing vacuoles. Furthermore, the data derived from proteomic mapping of Chlamydia inclusions has illuminated an important functional role for ERES in promoting chlamydial developmental growth.

59 BASIC BIOLOGICAL SCIENCES↗

Note: Advancement in tip etching for preparation of tunable size scanning tunneling microscopy tips

The two aspects of a scanning tunneling microscopy tip, the macroscopic profile and the nanoscale apex, can be tailored by controlling the tension during electrochemical etching and the solution-electrode contact area via acetone vapor. The apex diameter is shown to be proportional to the square root of the tension, and is demonstrated over apex diameters of 150-500 nm. The apex was found to be created in four distinct shapes where a secondary etching can reshape the tip into a single geometry. Improvement in tip height and stability of the profile are demonstrated versus a non-acetone fabrication control.

36 MATERIALS SCIENCE↗

Comparison of CT and MR-CT Fusion for Prostate Post-Implant Dosimetry

Purpose: The use of T2 MR for postimplant dosimetry (PID) after prostate brachytherapy allows more anatomically accurate and precise contouring but does not readily permit seed identification. We developed a reproducible technique for performing MR-CT fusion and compared the resulting dosimetry to standard CT-based PID. Methods and Materials: CT and T1-weighted MR images for 45 patients were fused and aligned based on seed distribution. The T2-weighted MR image was then fused to the aligned T1. Reproducibility of the fusion technique was tested by inter- and intraobserver variability for 13 patients. Dosimetry was computed for the prostate as a whole and for the prostate divided into anterior and posterior sectors of the base, mid-prostate, and apex. Results: Inter- and intraobserver variability for the fusion technique showed less than 1% variation in D90. MR-CT fusion D90 and CT D90 were nearly equivalent for the whole prostate, but differed depending on the identification of superior extent of the base (p = 0.007) and on MR/CT prostate volume ratio (p = 0.03). Sector analysis showed a decrease in MR-CT fusion D90 in the anterior base (ratio 0.93 {+-}0.25, p < 0.05) and an increase in MR-CT fusion D90 in the apex (p < 0.05). The volume of extraprostatic tissue encompassed by the V100 is greater on MR than CT. Factors associated with this difference are the MR/CT volume ratio (p < 0.001) and the difference in identification of the inferior extent of the apex (p = 0.03). Conclusions: We developed a reproducible MR-CT fusion technique that allows MR-based dosimetry. Comparing the resulting postimplant dosimetry with standard CT dosimetry shows several differences, including adequacy of coverage of the base and conformity of the dosimetry around the apex. Given the advantage of MR-based tissue definition, further study of MR-based dosimetry is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ambient Tip-Enhanced Photoluminescence with 5 nm Spatial Resolution

We achieve record spatial resolution in ambient tip-enhanced photoluminescence (TEPL) from CdSe/ZnS semiconductor quantum dots (QDs). Our approach only takes advantage of surface roughness at the apex of a sputtered plasmonic gold probe. When irradiated with visible light (633 and 532 nm lasers), nano-corrugated regions of the apex of an Au tip support 5-nm spatial resolution in TEPL imaging of QD aggregates on silicon. The reproducibility of our observations is illustrated using different plasmonic probes and samples. The origin of the observed near-field contrast, underlying the demonstrated high spatial resolution in TEPL, is discussed in the context of field enhancement at the metal tip-fluorophore interface.

Chemical Dynamics Initiative↗

Chemisorption-Induced Structural Changes and Transition from Chemisorption to Physisorption in Au6(CO)n-(n=4-9)

The interactions of CO with gold clusters are essential to understanding the catalytic mechanisms of CO oxidation on supported gold nanoparticles. Here we report a photoelectron spectroscopy and theoretical study of CO adsorption on a well-defined Au6- cluster in Au6(CO)n- (n = 4-9). Previous studies have shown that the first three CO successively bind the three apex sites of the triangular Au6-. The current work reveals that the forth CO induces a major structural change to create more apex sites to accommodate the additional CO. Definitive spectroscopic evidence is obtained for the chemisorption saturation at Au6(CO)6 -, in which Au6 has rearranged to accommodate the six CO adsorbates. The photoelectron spectra of larger clusters from Au6(CO)7 - to Au6(CO)9 - are observed to be almost identical to that of Au6(CO)6 -, suggesting that the additional CO’s are simply physisorbed onto the Au6(CO)6 - core. Quasirelativistic density functional calculations are performed on both Au6(CO)n and Au6(CO)n - (n = 4-6). The theoretical results are used to interpret the experimental observations and provide insight into the nature of CO interactions with gold clusters. The Au6 cluster is shown to be highly fluxional upon multiple CO adsorptions, stabilizing structures with more apex sites to accommodate the additional CO’s. The CO-induced structural transformation is analogous to structural flexibility and mobility in heterogeneous catalysis. The observations of the propensity of CO toward apex sites and CO-induced structural changes in small gold clusters m

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SIMS analyses of the oldest known assemblage of microfossils document their taxon-correlated carbon isotope compositions

Analyses by secondary ion mass spectroscopy (SIMS) of 11 specimens of five taxa of prokaryotic filamentous kerogenous cellular microfossils permineralized in a petrographic thin section of the ~3,465 Ma Apex chert of northwestern Western Australia, prepared from the same rock sample from which this earliest known assemblage of cellular fossils was described more than two decades ago, show their δ 13 C compositions to vary systematically taxon to taxon from -31‰ to -39‰. These morphospecies-correlated carbon isotope compositions confirm the biogenicity of the Apex fossils and validate their morphology-based taxonomic assignments. Perhaps most significantly, the δ 13 C values of each of the five taxa are lower than those of bulk samples of Apex kerogen (-27‰), those of SIMS-measured fossil-associated dispersed particulate kerogen (-27.6‰), and those typical of modern prokaryotic phototrophs (-25 ± 10‰). The SIMS data for the two highest δ 13 C Apex taxa are consistent with those of extant phototrophic bacteria; those for a somewhat lower δ 13 C taxon, with nonbacterial methane-producing Archaea; and those for the two lowest δ 13 C taxa, with methane-metabolizing γ-proteobacteria. Although the existence of both methanogens and methanotrophs has been inferred from bulk analyses of the carbon isotopic compositions of pre-2,500 Ma kerogens, these in situ SIMS analyses of individual microfossils present data interpretable as evidencing the cellular preservation of such microorganisms and are consistent with the near-basal position of the Archaea in rRNA phylogenies.

59 BASIC BIOLOGICAL SCIENCES↗

DYNAMICS OF DUST PARTICLES RELEASED FROM OORT CLOUD COMETS AND THEIR CONTRIBUTION TO RADAR METEORS

The Oort Cloud Comets (OCCs), exemplified by the Great Comet of 1997 (Hale-Bopp), are occasional visitors from the heatless periphery of the solar system. Previous works hypothesized that a great majority of OCCs must physically disrupt after one or two passages through the inner solar system, where strong thermal gradients can cause phase transitions or volatile pressure buildup. Here we study the fate of small debris particles produced by OCC disruptions to determine whether the imprints of a hypothetical population of OCC meteoroids can be found in the existing meteor radar data. We find that OCC particles with diameters D {approx}< 10 {mu}m are blown out from the solar system by radiation pressure, while those with D {approx}> 1 mm have a very low Earth-impact probability. The intermediate particle sizes, D {approx} 100 {mu}m, represent a sweet spot. About 1% of these particles orbitally evolve by Poynting-Robertson drag to reach orbits with semimajor axis a {approx} 1 AU. They are expected to produce meteors with radiants near the apex of Earth's orbital motion. We find that the model distributions of their impact speeds and orbits provide a good match to radar observations of apex meteors, except for the eccentricity distribution, which is more skewed toward e {approx} 1 in our model. Finally, we propose an explanation for the long-standing problem in meteor science related to the relative strength of apex and helion/antihelion sources. As we show in detail, the observed trend, with the apex meteors being more prominent in observations of highly sensitive radars, can be related to orbital dynamics of particles released on the long-period orbits.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetostatic dipolar domain-wall pinning in chains of permalloy triangular rings.

In a combined experimental and numerical study, we investigated the details of the motion and pinning of domain walls in isolated and interacting permalloy triangular rings (side 2 {micro}m, width 250 nm, and thickness 25 nm). To induce interaction between the rings, they were arranged either in vertical chains with an apex of each triangle in proximity to the edge center of the triangle above it or in horizontal chains where the proximity is between the adjacent corners of the triangles. Using longitudinal and diffraction magneto-optic Kerr effects, magnetic force microscopy, and micromagnetic simulations, we determined the field dependence of the spin structure in the rings. In all cases the remnant state of each ring is an 'onion' state characterized by two domain walls - one head to head the other tail to tail - pinned at the apexes. In isolated rings the magnetization reversal occurs between two onion states via the formation of an intermediate vortex state, which arises from the motion and annihilation of the two domain walls. In the case of the horizontal chains the reversal mechanism is unchanged except that the dipolar interaction affects the field range in which the rings are in the vortex state. In the case of vertical chains an additional intermediate state is observed during reversal. The new state involves a domain wall pinned at the center of the edge that is in close proximity to the apex of its neighbor. We show that the domain-wall motion in this last case can be modeled by a triple potential well. Because the new state requires that a domain wall be pinned at the neighboring apex, our observations can be viewed as a very elementary form of magnetic logic.

36 MATERIALS SCIENCE↗

SU-E-T-16: A Comparison of Expected Dwell Times and Dose Variations for NAMD Patients Treated with An Episcleral Brachytherapy Device

Purpose: To evaluate the variations in dwell times and doses expected when using an episcleral brachytherapy device for treatment of neovascular agerelated macular degeneration (n-AMD) based on accurate imaging modalities Methods: Data from 40 eyes from 40 subjects with known n- AMD acquired through the Distance of Choroid Study (DOCS) conducted at Moorfields Eye Hospital was used to determine the target depth; the distance from the outer scleral surface of the eye, through the choroid, to the apex of the choroidal neovascularization (CNV). Each subject underwent, in triplicate, enhanced-depth Spectral Domain Optical Coherence Tomography (SD-OCT), Swept Source Optical Coherence Tomography, (SS-OCT) and Ocular Ultrasound (O-US). These data are the most comprehensive and accurate measurements of the dimensions of the CNV and adjacent layers of the eye for this cohort of patients. During treatment of n-AMD, patients receive a dose of 24Gy to the apex at the target depth. Using the percentage depth dose for a Sr-90 episcleral brachytherapy device, dwell times and doses to the apex were computed to determine the expected variations. Results: The mean target depth and the 95% confidence interval (CI) determined by combining O-US with SD-OCT were 1326 (956,1696)µm and with SS-OCT were 1332 (970,1693)µm. The calculated corresponding mean dwell times and 95% (CI) were 334 (223,445)s and 335 (226,445)s for SD-OCT and SS-OCT determined depths, respectively. The corresponding mean apex dose and 95% (CI) were 24 (35.9,18.0)Gy (SD-OCT) and 24 (35.6,18.1)Gy (SS-OCT). Conclusion: For episcleral brachytherapy treatment of n-AMD, using a patient population average target depth for treatment planning is inadequate, resulting in dose variations of a factor of approximately two over the 95% CI and larger variations for a nontrivial segment of the population. Each patient should have individualized imaging studies to determine the target depth for use in the dwell time calculation. Study was sponsored by Salutaris Medical Devices, Ltd., a subsidiary of Salutaris Medical Devices, Inc. Hamilton and Marsteller are founders of Salutaris Medical Devices, Inc. Drew, McGovern and Vitali are minor equity holders in Salutaris Medical Devices, Inc.

60 APPLIED LIFE SCIENCES↗

SU-F-T-42: MRI and TRUS Image Fusion as a Mode of Generating More Accurate Prostate Contours

Purpose: Transrectal Ultrasound (TRUS) imaging is utilized intra-operatively for LDR permanent prostate seed implant treatment planning. Prostate contouring with TRUS can be challenging at the apex and base. This study attempts to improve accuracy of prostate contouring with MRI-TRUS fusion to prevent over- or under-estimation of the prostate volume. Methods: 14 patients with previous MRI guided prostate biopsy and undergone an LDR permanent prostate seed implant have been selected. The prostate was contoured on the MRI images (1 mm slice thickness) by a radiologist. The prostate was also contoured on TRUS images (5 mm slice thickness) during LDR procedure by a urologist. MRI and TRUS images were rigidly fused manually and the prostate contours from MRI and TRUS were compared using Dice similarity coefficient, percentage volume difference and length, height and width differences. Results: The prostate volume was overestimated by 8 ± 18% (range: 34% to −25%) in TRUS images compared to MRI. The mean Dice was 0.77 ± 0.09 (range: 0.53 to 0.88). The mean difference (TRUS-MRI) in the prostate width was 0 ± 4 mm (range: −11 to 5 mm), height was −3 ± 6 mm (range: −13 to 6 mm) and length was 6 ± 6 (range: −10 to 16 mm). Prostate was overestimated with TRUS imaging at the base for 6 cases (mean: 8 ± 4 mm and range: 5 to 14 mm), at the apex for 6 cases (mean: 11 ± 3 mm and range: 5 to 15 mm) and 1 case was underestimated at both base and apex by 4 mm. Conclusion: Use of intra-operative TRUS and MRI image fusion can help to improve the accuracy of prostate contouring by accurately accounting for prostate over- or under-estimations, especially at the base and apex. The mean amount of discrepancy is within a range that is significant for LDR sources.

60 APPLIED LIFE SCIENCES↗

On thermofield electron emission from metal microtips

The electric field in the vicinity of a cone apex has an integrable singularity. Therefore, in order to calculate the thermofield emission current from a conical tip, it is necessary to find the emission current density at extremely high electric fields at the cone apex. In this paper, an original method for correctly calculating the electric field near a perfect conical tip and a tip with a rounded apex is proposed. A universal numerical approach to calculating thermionic, field, and thermofield electron emission from metal in a wide range of surface electric fields is offered. It is shown that, at high electric fields, the thermofield current density tends to a certain limiting (saturated) value, and the reason for this saturation is revealed. It is found that, for moderate fields, the total electron emission current from a conical tip is determined by the current from the immediate vicinity of the apex and depends substantially on the curvature radius of its rounding.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗