Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ANNULAR FLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

90 records · Page 5

Effect of Cathode Cooling in Three-Dimensional Simulations of an Atmospheric Pressure Glow Discharge

The Atmospheric Pressure Glow Discharge (APGD) is a relatively simple and versatile plasma source used in a wide range of applications. Active cooling of the cathode can effectively mitigate instabilities, leading to glow-to-arc transitions. This study investigates the effect of varying the degree of cathode cooling in APGD with a planar cathode in helium. The plasma flow model incorporates mass conservation, chemical species transport, momentum conservation, conservation of thermal energy of heavy species and of electrons, and electrostatics. The model is applied to time-dependent simulations through a three-dimensional computational domain describing the whole discharge, without geometric symmetry or steady-state assumptions. Simulations of an experimentally characterized APGD explore the effects of electric current and cathode cooling—ranging from thermally insulated to extreme convective cooling. Results show the formation of an annular region with high electric field over the cathode surface under conditions of high current and low cooling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Propellant Mass Gauging in a Spherical Tank under Micro-Gravity Conditions Using Capacitance Plate Arrays and Machine Learning

Propellant mass gauging under micro-gravity conditions is a challenging task due to the unpredictable position and shape of the fuel body inside the tank. Micro-gravity conditions are common for orbiting satellites and rockets that operate on limited fuel supplies. Capacitance sensors have been investigated for this task in recent years; however, the effect of various positions and shapes of the fuel body is not analyzed in detail. In this paper, we investigate this with various fill types, such as annular, core-annular, and stratified fills at different positions. We compare the performance among several curve-fitting-based approaches and a machine-learning-based approach, the latter of which offers superior performance in estimating the fuel content.

47 OTHER INSTRUMENTATION↗

Combustor with dual pressure premixing nozzles

A combustor may include a combustor liner and flow sleeve. A high pressure air cools an outer surface of the combustor liner via openings in the flow sleeve, creating a lower pressure air in an annulus between the combustor liner and the flow sleeve. A first fuel nozzle is positioned at a primary combustion zone, and a second fuel nozzle is positioned at a secondary combustion zone of the liner. A fuel source is configured to deliver a fuel to the fuel nozzles. The fuel nozzles produce a premixture of high pressure air and the fuel, and produce a mixture of the premixture and the lower pressure air, prior to introducing the mixture to a respective primary or secondary combustion zone of the combustor. The combustor provides improved fuel premixing and is fuel flexible, and reduces pressure drop requirements. The combustor is usable in a can, annular, or segmented annular combustor assembly.

Berry, Jonathan Dwight↗

NMDQi Thermal-hydraulic Optimization, Analysis, and Scoping Tool (TOAST)

The Thermal-hydraulic Optimization, Analysis, and Scoping Tool (TOAST) is developed to support the thermal-hydraulic aspects for the design of optimal irradiation vehicles for the Nuclear Materials Discovery and Qualification initiative (NMDQi). TOAST is currently a MATLAB-based tool that utilizes a simplified steady-state analytical model where a radial thermal resistance circuit is utilized to account for conduction through up to 2 capsules, a gas gap, a thermal bond, a sample cladding, and a sample, as well as the convection from a water coolant outside the capsules. The geometry is discretized axially along the user-defined height of a basket with a user-defined number of points/nodes, essentially turning TOAST into a semi-2D heat transfer analysis utility for cylindrical irradiation vehicles with practically any configuration, solving for temperatures radially at multiple axial locations. TOAST utilizes a Graphical User Interface (GUI) in-which a user can define the geometrical layout, the materials utilized for each component, the coolant characteristics, and the required solution. The user can define the geometry by inputting the diameters, thicknesses, and heights for each component, whereas the materials are defined via the user-provided constant or variable thermal conductivities. The user can select the coolant's inlet temperature, pressure, and the pressure drop across the height of the problem (which is used to calculate the velocity of the flow). Finally, the user can choose to solve for a sample heat generation rate limit by inputting temperature limits for the sample and capsules or can choose to purely solve for the axial temperature distributions of each component by inputting a pre-selected heat generation rate. Either way, TOAST provides the user with axial temperature distributions of all the components including the coolant, and the heat generation rate limit as well as the maximum outlet coolant temperature. The user can also choose to do one of 6 sensitivity analyses in TOAST. The sensitivity analyses yield plots of the sensitivity of the heat generation rate limit, the maximum coolant temperature, and the pressure limit for the annular components due to perturbations in 1-2 unknown variables based on the selected sensitivity analysis. Benchmarks between computations in TOAST and equivalent 2D axis symmetric ABAQUS models are presented, showing that TOAST results are within less than 3% of ABAQUS results in most cases, and a maximum of 8% difference in some cases. The benchmarks also revealed that this uncertainty is tied to the selection of an appropriate Nusselt number correlation and appropriate thermal conductivities, which the user can do from the GUI. Regardless, TOAST is demonstrated as a computationally efficient, highly accessible, and accurate utility for optimization and scoping s of studies different irradiation vehicles.

42 ENGINEERING↗

Design optimization of gap distance for the capillary limitation of a heat pipe with annular-type wick structure

In this study, an experimental investigation was conducted on the rising height and contact angle of fluid in an annular wick-type heat pipe. The annular wick-type heat pipe was characterized by a small gap between the wick structure and tube wall, which compensated for the pressure drop along the porous media and created additional capillary force. To describe and model the advantage of this gap, the rising of a wetting liquid in the gap between a vertical solid plate and a mesh (with a small angle between them) was experimentally measured and analyzed. An additional experiment was performed to investigate the effect of curvature on the capillary rise using tubes and meshes of varying radii. Resultantly, we confirmed that the linear combination of the contact angles of the solid plate and mesh could be applied to calculate the rising height from the Laplace–Young equation. Furthermore, the effect of curvature on the rising height of the liquid was negligible. These results were extended to the investigation of finding the optimal gap distance for the annular wick-type heat pipe by referring to previous studies. We observed that a gap distance of 1.27 mm provided the largest permeability (K) over the effective pore radius (r eff ) value for a heat pipe with ethanol, which in turn resulted in the highest capillary limitation. For a sodium heat pipe, a gap distance of 0.84 mm resulted in the highest capillary limitation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sudden collapse of a pressure profile generated by off-axis heating in a linear magnetized plasma

Here, the features of an unexpected, large event that arises spontaneously during a basic heat transport experiment are presented. It consists of the sudden collapse of the radial plasma pressure profile, akin to disruption events observed in toroidal magnetic confinement devices. The experiment is performed on the Large Plasma Device at the University of California, Los Angeles (UCLA). It uses a LaB6 thermionic emitter of annular shape to induce off-axis heating of a cold, afterglow plasma, in a linear magnetic geometry. The temporal evolution consists of three regimes. During an early, quiescent period, classical heat transport along and across the magnetic field arises from Coulomb collisions. After significant pressure gradients develop, drift-Alfvén waves become unstable. Upon reaching large amplitude, they trigger avalanche events that flatten the outer part of the heated region, which, in turn, quenches the instability. Due to the sustained heating, the pressure profile rebuilds and the process repeats, leading to a relatively long, second regime that displays multiple avalanches, but suddenly, the annular pressure profile is observed to collapse. After this collapse, the system enters a third regime with large fluctuations. Before the collapse, a rapid, runaway heating environment arises whose time evolution exhibits a self-similar dependence on the applied voltage. The time evolution, morphology, and scaling of the collapse event are presented, and an examination is made of the underlying mechanisms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Analysis of Advanced Turbine for Supercritical CO2 Power Cycle

An advanced first stage high pressure turbine blade for a supercritical CO2 power cycle is tested in the Big Rig for Aerothermal Stationary Turbine Analysis (BRASTA) annular cascade at the Purdue Experimental Turbine Aerothermal Laboratory (PETAL) high pressure blow down facility alongside a baseline blade for comparison of aerodynamic performance. Both geometries are tested simultaneously using a novel off-axis rig design to allow for the blade geometries to be scaled up to achieve higher Reynolds numbers. The off-axis design necessitates the use of discrete sectors of airfoils, which are designed and additively manufactured in house using an mSLA printer. Printing the blades allows for unique routing of passage for blade surface static pressure taps that contour to the blade shape instead of requiring a straight line view from surface tap to egress, allowing all instrumentation for 15%, 50%, and 85% span to exist in the same passage. A flow conditioning gauze [1] is placed upstream of the blade passages to impart pressure, Mach, and swirl profiles to mimic the rotor relative frame inlet conditions to the blade. Downstream, a sonic valve is used to alter the backpressure to achieve different pressure ratios for different blowdown setpoints. The design of the rig, sonic wheel, and instrumentation are discussed along with the manufacturing and GD&T of the blades with respect to the build-up of this novel experimental apparatus. Initial commissioning data is obtained from inlet total pressure and temperature rakes, blade static pressure taps, and exit total pressure rakes. Oil visualization is performed using a silicone oil mixture containing titanium dioxide and pigmented for contrast of the blade suction side surface with the hub and shroud endwalls. The viscosity of the oil is tuned so that the oil does not fully thin and blow away during the time of the test, and endoscopic cameras are placed in the rig for live monitoring and recording. The preliminary oil visualization and rake profiles are presented, showcasing the operability of this additively manufactured off-axis flow path design.

Tuite, Logan [Purdue University]↗

Development and construction status of the Mu2e electromagnetic calorimeter mechanical structures

Abstract The Mu2e experiment at Fermilab will search for the CLFV neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the evidence of physics beyond the Standard Model. Mu2e comprises a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides electron identification, a fast trigger and aids track reconstruction. It is a state-of-the-art crystal calorimeter and employs 1340 pure CsI crystals readout by UV-extended SiPM and fast electronics. The design consists of two identical annular disks positioned at the relative distance of 70 cm downstream the target.The hostile Mu2e conditions (total ionizing dose of 12 krad and a neutron fluence of 5 × 10 10 n/cm 2 @ 1 MeVeq (Si)/y, 1 T magnetic field and vacuum level of 10 −4 Torr) posed tight constraints on the mechanical structures and materials choice. The support structure of the two crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. SiPMs and front-end electronics for each crystal are assembled in one mechanical unit inserted in a machined copper holder. The units are supported by a plate made of vacuum-compatible material. The plate integrates the cooling system made of a network of copper lines flowing a low temperature fluid and placed in thermal contact with the copper holders. The DAQ is hosted in aluminum crates positioned on the lateral surface of the disks. The crates also integrate the DAQ electronics cooling system. We review the constraints on the calorimeter structures design, the development of all the structural components, including the simulations that have determined the materials and technological choices and the specifications of the cooling station, components production and quality assurance tests, the procedures for detector assembly, transportation and installation in the experimental area.

Instruments & Instrumentation↗

Wellbore cement fracture permeability as a function of confining stress and pore pressure

Cemented annulus fractures are a major leakage path in a wellbore system, and their permeability plays an important role in the behavior of fluid flow through a leaky wellbore. The permeability of these fractures is affected by changing conditions including the external stresses acting on the fracture and the fluid pressure within the fracture. Laboratory gas flow experiments were conducted in a triaxial cell to evaluate the permeability of a wellbore cement fracture under a wide range of confining stress and pore pressure conditions. For the first time, an effective stress law that considers the simultaneous effect of confining stress and pore pressure was defined for the wellbore cement fracture permeability. Here the results showed that the effective stress coefficient (λ) for permeability increased linearly with the Terzaghi effective stress ( -p) with an average of λ = 1 in the range of applied pressures. The relationship between the effective stress and fracture permeability was examined using two physical-based models widely used for rock fractures. The results from the experimental work were incorporated into numerical simulations to estimate the impact of effective stress on the interpreted hydraulic aperture and leakage behavior through a fractured annular cement. Accounting for effective stress-dependent permeability through the wellbore length significantly increased the leakage rate at the wellhead compared with the assumption of a constant cemented annulus permeability.

58 GEOSCIENCES↗

Development, construction and qualification tests of the mechanical structures of the electromagnetic calorimeter of the Mu2e experiment at Fermilab

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides excellent electron identification, complementary information to aid pattern recognition and track reconstruction, and a fast calorimetric online trigger. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1340 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements.The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5x1010 n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 670 crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 670 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system.The constraints on the calorimeter mechanical structures design, the development from the conceptual design to the specifications of all the structural components, the status of components production and the components quality assurance tests are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and assembling status of the Mu2e electromagnetic calorimeter mechanical structures

The muon-to-electron conversion (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named disks ) positioned at the relative distance of 70 cm, downstream the aluminum target along the muon beamline, satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5 10^{10} n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10−4 Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 674 crystal matrices employs two aluminum hollow rings and parts made of open- cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 674 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal con- tact with the copper holders. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system. In this poster we will review the constraints on the calorimeter mechanical structures, the technological choices, and the status of assembling at Fermilab.

Pasciuto, D.↗

Development, construction and tests of the Mu2e electromagnetic calorimeter mechanical structures

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the charged lepton flavour violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of the existence of physics beyond the standard model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. In particular, the calorimeter provides excellent electron identification, a fast calorimetric online trigger, and complementary information to aid pattern recognition and track reconstruction. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total expected ionizing dose of 12 krad and a neutron fluence of 5 × 10$^{10}$ n/cm$^{2}$ @ 1 MeV$_{eq}$ (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on scintillating materials, sensors, electronics and on the design of the detector mechanical structures and material choice. The support structure of each 674 crystal matrix is composed of an aluminum hollow ring and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and front-end electronics for the readout of each crystal are inserted in a machined copper holder and make a unique mechanical unit. The resulting 674 mechanical units are supported by a machined plate of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics are hosted in aluminum custom crates positioned on the external lateral surface of the disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system. In this paper we report on the calorimeter mechanical structure design, the mechanical and thermal simulations that have determined the design technological choices, and the status of component production, quality assurance tests and plans for assembly at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancement of EM Pump Performance through Modeling and Testing

Liquid sodium has seen development as a nuclear reactor coolant in the United States for over 50 years. While sodium has many desirable characteristics as a heat transfer fluid, its reactivity poses numerous engineering challenges for even the most basic plant components like pumps. Despite the challenges, mechanical pumps have seen success in sodium service albeit at the expense of simplicity and flexibility. In fact, significant failures of these pumps have been recorded which can be attributed to their complexity. Notwithstanding the complexity, mechanical pumps are still widely proposed for the main circuit pump of sodium cooled reactors. However, an alternative to mechanical pumps are Electromagnetic Induction Pumps (EMIPs) which use the principle of the Lorentz Force. EMIPs avoid mechanically moving parts in contact with sodium which simplifies the design by avoiding mechanical wear and seals. Therefore, these pumps are generally safer and more reliable than their mechanical counterparts. That being said, EMIPs suffer from relatively low efficiencies that range from 5% to 45%. Some of the inefficiencies are inherent to the EMIPs pumps; namely, inefficiencies arise in the form of resistive heating losses in the fluid itself. However, other inefficiencies arise from Edge Effects which include Finite Length and Finite Width effects. Due to the significant safety advantages EMIPs have compared to mechanical pumps, there is a strong motivation to integrate these technologies into the design of Generation IV liquid-metal-cooled nuclear power plants. However, EMIPs have low efficiencies partly attributed to Edge Effects. Much of the literature focusing on Edge Effects is dated or simply does not exist in the public domain. More recently, numerical models of EMIPs have shown promising results. However, these models are often custom solvers or use complex software suits which limit their application. This report describes the work completed to understand Edge Effects in two EMIPs designs. These designs are the Annular Linear Induction Pump (ALIP) and Permanent Magnet Induction Pump (PMIP) also known as a Moving Magnet Pump (MMP). The methodology developed during this project aim at measuring key performance parameters (pressure-flowrate and efficiency-slip performance) using high temperature liquid-sodium. Baseline experimental measurements were then used to verify the accuracy of numerical models developed in the software suit ANSYS/FLUENT. On the experimental side, instrumentation was developed to characterize the pressure-flowrate and efficiency-slip performance of both the ALIP and PMIP in high-temperature liquid-sodium. Additionally, instrumentation was developed to measure potential output pressure pulsations and the magnetic field distributions. Moreover, a specialized ALIP was constructed to study the impacts magnetic field tapering, also known as coil grading, on the Finite Length Effect. Lastly, experimental performance curves of the PMIP were collected at 300 oC and 600 oC and compared to analytical theory which accounted for Finite Width Effects. These results showed that the Finite Width Effect and non-uniform magnetic field in a PMIP impact the performance. On the numerical side, models were developed using the software suit FLUENT/ANSYS. These methods were initially compared against a simple MHD flow in a Permanent Magnet Electromagnet Flowmeter (PMEMFM). The results were significant in that they showed agreeance between the numerical model and demonstrated that PMEMFM’s could be calibrated numerically. These modeling methods were then applied to a prototypic PMIP. Results showed that this simple model provided reasonably accurate results of the PMIP p-Q performance.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Entropy generation from hydrodynamic mixing in inertial confinement fusion indirect-drive targets

The increase in entropy from the physical mixing of two adjacent materials in inertial confinement fusion (ICF) implosions and gas-filled hohlraums is analytically assessed. An idealized model of entropy generation from the mixing of identical ideal-gas particles across a material interface in the presence of pressure and temperature gradients is applied. Physically, mix-driven entropy generation refers to the work done by the gases in expanding into a larger common volume from atomic mixing under the condition of no internal energy change, or work needed to restore the initial unmixed state. Furthermore, the effect of a mix-generated entropy increase is analytically shown to lead to less compression of the composite ICF fluid under adiabatic conditions. The amount of entropy generation is estimated to be ~10 J for a Rayleigh–Taylor-induced micrometer-scale annular mixing layer between the solid deuterium–tritium fuel and (undoped) high-density carbon pusher of an imploding capsule at the National Ignition Facility (NIF). This level of entropy generation is consistent with lower-than-expected fuel compressions measured on the NIF [Hurricane et al., Phys. Plasmas 26, 052704 (2019)]. The degree of entropy increase from mixing of high-Z hohlraum wall material and low-Z, moderate- to high-density gas fills is estimated to lead to ~100 kJ of heat generation for NIF-scale experiments [Moody et al., Phys. Plasmas 21, 056317 (2014)]. This value represents a significant fraction of the inferred missing x-ray drive energy based on observed delays in capsule implosion times compared with mainline simulations [Jones et al., Phys. Plasmas 19, 056315 (2012)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of the moderators in the STS preliminary design

This report details the results for an optimization of the dimensions of the moderators in the preliminary design of the Spallation Neutron Source Second Target Station (STS). This study uses the optimization algorithms of Dakota and an unstructured mesh model for the moderators in MCNP. More details on the unstructured mesh model and the automated mesh generation can be found in [3]. Parallel to this effort, the same moderator geometries have been optimized using a constructive solid geometry (CSG) MCNP model. More details on this model and its results can be found in [4]. Three optimal designs are selected for each moderator: one that is optimized for maximum peak brightness, one for maximum time-integrated brightness, and one for a combination of peak and time-integrated brightness. The backbone of the optimization work flow is provided by Dakota. For each set of design parameters requested by Dakota, a new solid geometry is automatically built in Creo and SpaceClaim, and subsequently exported to Attila4MC to generate an unstructured mesh geometry for MCNP. After the MCNP calculation is finished, the objective function (e.g., brightness metric) is returned to Dakota. After the new design has been evaluated, a result-file is written, and Dakota proposes the next set of design parameters to be evaluated. The loop continues until a specified convergence criterion has been met. The design parameters of the cylindrical (upper) moderator include the hydrogen radius, the premoderator thickness (top, bottom, radial), the beryllium radius and the horizontal position of the moderator. The crucial design choice is the hydrogen radius. A radius of 62 mm is shown to provide the maximum time-integrated brightness. The maximum peak brightness occurs with a radius of 40 mm. A combined (middle) design, which balances peak and time-integrated brightnesses, is obtained with a hydrogen radius of 50 mm. The premoderator thicknesses and the beryllium radius are slightly larger in the design optimized for time-integrated brightness than in the design optimized for peak brightness. The sensitivity to these two parameters is relatively small close to the optimal configurations. The hydrogen vessel and vacuum vessel wall thicknesses are dependent on the radius of the liquid hydrogen due to structural integrity requirements. The increased wall thicknesses for larger vessels significantly penalize the time-integrated brightness, with the maximum obtainable value reduced by more than 10% relative to earlier studies which used fixed vessel wall thicknesses. The impact of the variable wall thicknesses is much less for the peak brightness and combined brightness designs. The design parameters of the tube (lower) moderator selected for the optimization are the tube length, the annular premoderator thickness, the beryllium radius and the horizontal position of the moderator. The tube length is the crucial parameter and is chosen large (210 mm) and small (125 mm) in the designs optimized for time-integrated and peak brightness respectively. A combined optimal design has a tube length of 170 mm. The premoderator thickness and the beryllium radius are chosen larger in the design optimized for time-integrated brightness.

42 ENGINEERING↗

Experimental study on the startup of the annular wick type heat pipe using fiber optical temperature measurement technique

This study used optical fiber-distributed temperature sensors to measure the internal and external temperature distributions of a water-cooled heat pipe. The sensor technology used in this study is fiber optical distributed temperature sensing, a distributed sensing technique based on the naturally occurring Rayleigh backscatter in optical fibers. This measurement technique provides maximum spatial resolution for static and semi-static applications. Using this sensor, the temperature distribution of the heat pipe's internal, external, vapor core, and the wick was measured with a spatial resolution of 0.65 mm, a sampling frequency of 40 Hz, and a temperature resolution of 0.1 °C. Through the measured temperature distribution database, the starting phenomenon, the effective length trend, and the limitation onset were observed. From the results, it is found that a high-temperature peak appears at the evaporator if a high initial power (75 W) is imposed on the heat pipe, even after the heat pipe approaches the normal operating status. The peak is not observed in a slower startup (30 W initial power then slowly increased to 75 W). It is also found that the temperature distributions and effective condenser length of the heat pipe highly depend on the cooling conditions. There are variations in the temperature according to the radial direction of the horizontal heat pipe due to gravity. In conclusion, lead and lag of the temperature evolution were observed at the onset of the operating limitations.

42 ENGINEERING↗

Implosion dynamics of triple-nozzle gas-puff z pinches on COBRA

Experiments on the 1-MA, 220-ns COBRA generator at Cornell University were conducted to provide detailed measurements of structured cylindrical gas-puff z pinches. In the experiments, a 7 cm diameter triple-nozzle gas valve assembly with concentric outer and inner annular nozzles and a central gas jet initialize the z-pinch load with various working gases, radial density profiles, and externally applied axial magnetic fields. Planar laser-induced fluorescence provides a measure of the initial neutral gas density of the load, while three-frame laser shearing interferometry and multi-frame extreme ultraviolet (XUV) cameras reveal the formation and propagation of a magneto-Rayleigh–Taylor (MRT) unstable shock layer. Implosion trajectories are compared to simple, experimentally informed models and found to be in good agreement. Differences in the structure of the accelerating plasma sheath and evolution of the MRT instability are observed for different gas species and axial magnetic field strengths, correlating with differences in pinch uniformity and x-ray emission. Here, the average instability growth is compared to linear MRT theory predictions using the instantaneous acceleration of the best-fit implosion models and characteristic instability wavelength, with the effective Atwood number and seed perturbation size as fit parameters. For high density argon center jets, ionization prior to the arrival of the imploding plasma sheath suggests a heating mechanism consistent with photoionization by XUV self-emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Critical heat flux on zircaloy and accident tolerant fuel cladding under prototypical conditions of pressurized and boiling water reactors

First of a kind high spatial and temporal resolution temperature measurements of Pressurized Water Reactor and Boiling Water Reactor simulated fuel pins (high heat flux cosine profile heaters) in annular rod type geometry during nucleate boiling, departure from nucleate boiling and re-wetting has been performed. Distributed fiber optic measurements of the cladding axial temperature with spatial resolutions down to 2.5 mm axially at up to three equally spaced azimuthal locations per rod have demonstrated the similarities and differences of the different accident tolerant fuel cladding materials. These experiments show the performance of accident tolerant cladding with a precise measurement of the location and evolution of dryout followed by the re-wetting phenomena (see supplementary time history of a critical heat flux event). Experimental parameters varied coolant mass fluxes from 1695 to 2712 kg/m 2 s, pressures from 10 to 20 MPa, and inlet subcooling from 10 to 55 °C. It was found that the coatings and different material have little effect on the value of the critical heat flux. Any discrepancies between the local critical heat flux verified among the cladding material are attributed to different departure from nucleate boiling phenomena captured during the experiment with the high-resolution optical fiber temperature data. Substantial differences in the performance of the different cladding material to survive a critical heat flux event were however observed by post-test X-ray and optical inspection. External evident damage and internal cracks to the simulated fuel pin having the bare zircaloy cladding were observed in regions associated with the occurrence of the critical heat flux for longer periods. Such damages were associated with zirconium oxidation, and not noticed on the Cr coated zircaloy or FeCrAl claddings. These results indicate that the use of FeCrAl or a Cr coated zircaloy as cladding in Pressurized Water Reactor and Boiling Water Reactor may increase the survivability of the cladding material for short transients.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗