Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AIRFLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Ventilation in Residential Care Environments

The purpose of this study was to evaluate the effect of ventilation rate, directional airflow (e.g. pressure relationships) and airflow barriers on bioaerosol concentration and movement within assisted-living and residential care environments. Included within this report is a comprehensive literature review, field data collection test plan and, an evaluation of commercially available mitigation technologies related to the transmission of COVID-19 in LTC environments. Additionally, this report includes aerosol testing in an actual LTC facility using the test plan developed herein. Nearly 1.5 million people live in 16,000 nursing homes in the U.S. As of December 20, 2020 the Centers for Medicare and Medicaid Services (CMS) identified a total of 662,549 confirmed and suspected COVID-19 cases in these and other long-term care (LTC) facilities resulting in 92,373 deaths. At this time, COVID-19 cases in LTC facilities accounted for only 3% of the U.S. total of 21M confirmed cases yet nearly a third of the 350,000 total U.S. deaths. Preliminary studies have found little correlation between the quality of care and transmission of COVID-19 in these facilities, suggesting that even the best infection control practices may not be effective in containing the spread of this potentially airborne disease. As a result, many LTC facilities have implemented quarantine procedures and other measures to isolate infectious residents from the general population. Unfortunately, most LTC facilities were not designed for airborne infection control and guidance for retrofitting existing LTC spaces for airborne isolation is limited.

42 ENGINEERING↗

Technical analysis of filter testing at the U.S. Department of Energy Filter Test Facility

The U.S. Department of Energy (DOE) technical standard DOE-STD-3020-2015 requires verification testing at the Filter Test Facility (FTF) of high-efficiency particulate air (HEPA) filters to be installed in nuclear facility (Hazard Category 1, 2, 3, and radiological facilities) confinement ventilation systems, or to be installed in habitability systems (e.g., filters for protection of workers required to act for the control and mitigation of emergency situations). Filters in these applications perform a safety function in accident situations, are designated as important to safety, or are necessary for habitability systems. Different FTFs have operated for decades, and results of tests are available to examine the need for and benefits of continued execution of 100 percent QA verification testing. The objective of this study and resulting report was to assess the need for 100 percent QA testing at the current FTF in Maryland, based on an examination of a database of test results from 2013 to August 2020. Filters that require independent testing per DOE-STD-3020-2015 to be installed in nuclear facilities are sent to the FTF before being shipped to the facilities. The FTF examines the documentation (e.g., certificates of compliance, results of particle penetration and airflow resistance testing by the manufacturers, labels affixed to filters and packages, and other requirements specified in purchase orders by the nuclear facility operators), implements visual inspections of the physical state of the filters, and checks the dimensions of frames. Filters that meet the documentation and visual inspection requirements are subjected to particle penetration and airflow resistance testing. In case of rejections, the filters are shipped back to the manufacturers, at the cost of the manufacturers, for replacement. Filters that pass all tests are shipped to the nuclear facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced HVAC Humidity Control for Hot-Humid Climates

During this project we develop and validate a cost-effective, integrated control solution to improve humidity control and comfort for energy-efficient homes in hot-humid climates. This study focuses on developing a strategy that is effective, field tested, and practical for builders to install with minimal disruption to standard practices. A successful solution would simplify the transition to high-performance humidity control and be the basis for design and installation guidance. By relying on the central system as a starting point, the strategy employed minimizes system complexity and cost for builders, while improving comfort and operating cost for homeowners. The solution strategy was to coordinate the cooling, dehumidification, and ventilation functions of central, ducted HVAC systems to better control indoor humidity, improve occupant thermal comfort, and capture energy savings. The primary strategic goals were to: (1) optimize dehumidification by the central air-conditioning system, particularly during part-load conditions, using conventional equipment with modified control settings and lower system airflows; (2) maximize ventilation during heating/cooling on-cycles, to “bank” and condition outdoor ventilation air, and minimize ventilation during off-cycles; (3) quantify the effectiveness and energy impact of the dehumidification and ventilation strategies, while identifying a metric that would be useful to evaluate latent effectiveness. For the test houses in our study, located in Richmond Hill, Georgia; Houston, Texas; and Monroe, Louisiana we observed: (1) the indoor humidity did not exceed 60% RH during the monitored cooling season for 99% of the time in Richmond Hill, 96% of the time in Houston, and 90% of the time in Monroe; (2) the dehumidification strategy improved the steady-state latent capacity of the HVAC system at design conditions by 16% to 49% at the Houston test house and by 28% to 71% at the Monroe test house, depending on which mode the system was operating in; and (3) the good results at the test houses were primarily due to the amount of time the air-conditioning system operated in ramping or dehumidification modes, or both, particularly during the early cooling season. This study demonstrates that air conditioners or heat pumps with a single-stage compressor can provide good humidity control without the need for a two-stage or variable-stage compressor system. The airflow and control settings for ramping and dehumidification modes are critical to control indoor humidity in hot-humid climates, particularly during part-load and shoulder season conditions. The dehumidification strategy used in this study did not jeopardize the mechanical reliability of the cooling equipment. The strategies used in this study are applicable across various equipment brands, models, and efficiency levels, and also applicable to a broad range of homes in hot-humid climates. Results will vary by specific equipment, location, and house configuration and construction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Statistical Analysis of Imaging Laser Scan Data of an Exhaust Tunnel at the SRS

• The SRS H-Canyon Building is a critical facility under the responsibility of DOE-EM. • It includes an Air Exhaust Tunnel (HCAEX) that allows for ventilation of the process airflow. • Inspections are performed remotely because of hazards, e.g. radioactivity, debris, high airflow, and nitric acid vapors.

Wells, William Willie [Savannah River National Lab↗

New Thermochemical Salt Hydrate System for Energy Storage in Buildings

This paper introduces an innovative design for an “inorganic salt-expanded graphite” composite thermochemical system. The storage unit is made of a perforated, compressed, expanded graphite block impregnated with molten CaCl 2 ∙6H 2 O; the humid air passes through the holes that allow the moisture to diffuse and react with the salt. The prepared block underwent 90 hydration-dehydration cycles. Although most of the performed cycles were carried out with salt overhydration and deliquescence, the treated samples have remained mechanically and thermally stable with no drop in energy density. The volumetric energy density of the composite ranged from 135.5 to 277.6 kWh/m 3 , depending on airflow rate and absolute humidity. To ensure composite material cycling stability, the energy density of the block was measured during hydration at similar conditions of absolute humidity, inlet temperature, and airflow rate (0.01 kg water /kg air , 20 °C, 400 l/min). The average energy density at these conditions was sustained at 219 kWh/m 3 . The block integrity was monitored by visual inspection after removing it from the reactor chamber every few cycles. Both the composite material and its manufacturing process are simple and easy to scale up for future commercialization.

25 ENERGY STORAGE↗

The mechanisms and seasonal differences of the impact of aerosols on daytime surface urban heat island effect

The urban heat island intensity (UHII) is the temperature difference between urban areas and their rural surroundings. It is commonly attributed to changes in the underlying surface structure caused by urbanization. Air pollution caused by aerosol particles can affect the UHII through changing (1) the surface energy balance by the aerosol radiative effect (ARE) and (2) planetary-boundary-layer (PBL) stability and airflow intensity by modifying thermodynamic structure, which is referred to as the aerosol dynamic effect (ADE). By analyzing satellite data and ground-based observations collected from 2001 to 2010 at 35 cities in China and using the WRF-Chem model, we find that the impact of aerosols on UHII differs considerably: reducing the UHII in summer but increasing the UHII in winter. This seasonal contrast is proposed to be caused by the different strengths of the ARE and ADE between summer and winter. In summer, the ARE on UHII is dominant over the ADE, cooling down surface temperature more strongly in urban areas than in rural areas because of much higher aerosol loading, and offsets the urban heating, therefore weakening UHII. In winter, however, the ADE is more dominant, because aerosols stabilize the PBL more in the polluted condition, weakening the near-surface heat transport over urban areas in both vertical and horizontal directions. This means that the heat accumulated in urban areas is dispersed less effectively, and thus the UHII is enhanced. These findings shed new light on the impact of the interaction between urbanization-induced surface changes and air pollution on urban climate.urban areas and their rural surroundings. It is commonly attributed to changes in the underlying surface structure caused by urbanization. Air pollution caused by aerosol particles can affect the UHII through changing (1) the surface energy balance by the aerosol radiative effect (ARE) and (2) planetary-boundary-layer (PBL) stability and airflow intensity by modifying thermodynamic structure, which is referred to as the aerosol dynamic effect (ADE). By analyzing satellite data and ground-based observations collected from 2001 to 2010 at 35 cities in China and using the WRF-Chem model, we find that the impact of aerosols on UHII differs considerably: reducing the UHII in summer but increasing the UHII in winter. This seasonal contrast is proposed to be caused by the different strengths of the ARE and ADE between summer and winter. In summer, the ARE on UHII is dominant over the ADE, cooling down surface temperature more strongly in urban areas than in rural areas because of much higher aerosol loading, and offsets the urban heating, therefore weakening UHII. In winter, however, the ADE is more dominant, because aerosols stabilize the PBL more in the polluted condition, weakening the near-surface heat transport over urban areas in both vertical and horizontal directions. This means that the heat accumulated in urban areas is dispersed less effectively, and thus the UHII is enhanced. These findings shed new light on the impact of the interaction between urbanization-induced surface changes and air pollution on urban climate.

54 ENVIRONMENTAL SCIENCES↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Zonal Infiltration Measurement Method for Multifamily Buildings: A Novel Test Procedure to Determine Air Leakage Through External and Internal Surfaces

Measuring air infiltration through the external building envelope as well as between adjacent zones within a building is important since air leakage is related to increased energy use and poor indoor air quality (IAQ). State of the art methods can determine both leakages, however it can be both time consuming and labor intensive as it requires running both guarded and compartmentalization tests. This paper presents our work on developing a simplified testing procedure to determine power law flow equation leakage parameters of both external and internal boundaries of tested zones. The proposed Zonal Multipoint Pressure Test (ZMPT) method modulates airflow in the zone using a variable airflow measurement panel (mounted in either a window or the door), and solving the mass balance equations for the leakage parameters. ZMPT results were compared to conventional test results and found to correlate to within +/-7%.

Jayarathne, Tharanga↗

Metrics for Interzonal Dispersion Assessment of Airborne SARS-CoV-2 Within Office Buildings

High ventilation rate is increasingly considered as a mitigation strategy in the rapid spread of COVID-19 in existing buildings in addition to other options like UVGI and added filtration. However, this and other similar measures may also impact energy use and the efficiency of the buildings in which they are installed. Without concrete metrics, the impact of all these potential changes to the system cannot be properly assessed relative to the other impacts the measures might have, including additional energy use, added operation and maintenance costs, and reduced system life. Multizone airflow and contaminant transport simulations involving parameters such as infiltration rate, system configuration, and level of occupancy can provide critical information on relative risk distribution within a building. In this study, prototype airflow models are used to assess the degree to which ventilation-related measures can mitigate the spread of a virus like SARS-CoV-2 in a similar way that prototype energy models are used to study energy efficiency measures. A new detailed medium-sized office building prototype model is developed using the CONTAM software to represent contaminant transport in buildings like those modeled by the U.S. Department of Energy’s detailed medium office prototype model. The goal of this study is to generate a set of suitable metrics that will give a whole-building picture of airborne SARS-CoV-2 virus distributions across the different zones of the building under different parameters and scenarios.

DeGraw, Jason↗

Environmental control and air distribution system and method of using the same

An indoor environmental control and air distribution system for a building includes: an air handling unit; a manifold connected to the air handling unit having a chamber formed by a plurality of walls and a plurality of orifices formed through at least one of the walls; air distribution conduits each independently having a first end connected to the orifices of the manifold and a second end extending out from the manifold into different zones throughout the building; and an airflow modulating device having one or more airflow regulating dampers independently configured to move into at least two positions in which each position provides a different percentage of total air volume to each air distribution conduit. A method of using the indoor environmental control and air distribution system is also included.

Poerschke, Andrew↗

Design Optimization of A-Type Heat Exchangers based on High Performance, Non-Round Tubes

Air-to-refrigerant heat exchangers (HXs) have been the topic of considerable research as they are the fundamental heat transfer components of HVAC&R systems. For residential and commercial applications, indoor heat exchangers are often in A-type configurations to reduce air-conditioner system footprint while still delivering the required cooling or heating. Classical HX design practices typically assume a uniform frontal air velocity profile to facilitate the use of conventional tube-fin airside heat transfer and pressure drop correlations for performance prediction. However, it is well-reported throughout the literature that A-type HXs experience significant airflow maldistribution which can severely degrade HX performance. Additionally, recent advancements in simulation software such as Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA) and optimization algorithms have led researchers to consider primary heat transfer surface optimization to achieve highly compact HXs which do not require fins. In this paper, an A-type HX which utilizes shape-optimized non-round tubes is optimized for minimum duct size and airside pressure drop. This is achieved through coupling of an experimentally validated finite volume HX model with automated 2D CFD simulations of airflow through the HX for airside thermal-hydraulic performance evaluation. Preliminary results show that the optimal designs deliver similar capacity while achieving 20% reductions in airside pressure drop and duct cross-section area. Additionally, the optimal design apex angles in this study were similar to those from previous A-Type HX optimization studies for conventional tube-fin HX geometries, suggesting that the apex angle for optimal A-Type configuration performance may be independent of tube geometry.

42 ENGINEERING↗

Nationwide Energy Saving Potential Evaluation for Office Buildings with Occupant-Based Building Controls

The heating ventilation and air-conditioning (HVAC) system is a major contributor to building energy consumption. This paper aims to quantify the nationwide energy savings potential of implementing the occupancy-based control (OBC) for the HVAC system in typical medium-sized office buildings using a whole building simulation program (i.e., EnergyPlus). First, the medium-sized office from the DOE Commercial Prototype Building Models was modified to have detailed layout and space functions. Then, a statistic-algorithm-based tool was used to generate the dynamic occupancy schedules for various rooms. Next, both a baseline case and two OBC cases were created for the comparison based on the updated ASHRAE Standard 90.1 and ASHRAE Guideline 36. The HVAC operation in the baseline case follows a static occupancy schedule and fixed setpoint schedules for both room air temperatures and minimal system outside air flowrates, while the proposed OBC cases use the room temperature reset, system minimum outdoor airflow reset, and zone minimal supply airflow rate reset. These cases were extended to five climate zones in the United States to further quantify the energy savings potential associated with the OBC on a nationwide scale. The preliminary result of this case study shows that there could be significant energy savings potential from the proposed OBC strategies in medium-sized office buildings in the United States.

Pang, Zhihong↗

Analysis of Frost Prevention for Heat Recovery Ventilation in an Arctic Facility

Sub-Arctic environments present a unique challenge for the continuous operation of mechanical ventilation systems in occupied buildings where cold temperatures create complications for maintaining adequate air quality, efficiency, and system operability. Heat recovery ventilation is most difficult at the coldest temperatures, when there is the greatest availability to transfer heat between airstreams, due to the potential for frost accumulation in the exhaust airstream. Frost limits heat transfer and creates the potential for subsequent blockage of airflow. A successful frost prevention strategy is necessary to ensure that recovery ventilation systems function in locations with a large amount of annual heating degree days. Commonly, this is achieved by preheating outdoor air above freezing temperatures via airflow through a glycol-water mix hydronic coil before heat exchange occurs. Preheating the outdoor air proactively inhibits frost formation but is associated with a penalty to recovery efficiency. A commercial-scale heat recovery ventilator in a facility in Fairbanks, Alaska was analyzed for sensible recovery effectiveness and exhaust temperature at different winter conditions. The system utilized the common defrost strategy of preheating the air above-freezing with a static temperature control scheme. The heat transfer efficiency of the recovery ventilator was observed to be poor at various winter conditions with elevated exhaust temperatures indicating lost heat recovery effectiveness. Using prior findings on strategies for sub-freezing temperatures along with observed field conditions it was determined that a dynamic relationship between the coil and the exterior conditions would reduce the energy required to preheat the air and allow the heat exchanger to maximize effectiveness due to temperate difference. This reduction in preheated temperature of the air is achieved by modulating the temperature of the coil to keep the discharge air stream above a certain dewpoint temperature threshold, likely leading to energy savings for other sub-Arctic facilities using this frost control strategy.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Environmental control and air distribution system and method of using the same

An indoor environmental control and air distribution system for a building includes: an air handling unit; a manifold connected to the air handling unit having a chamber formed by a plurality of walls and a plurality of orifices formed through at least one of the walls; air distribution conduits each independently having a first end connected to the orifices of the manifold and a second end extending out from the manifold into different zones throughout the building; and an airflow modulating device having one or more airflow regulating dampers independently configured to move into at least two positions in which each position provides a different percentage of total air volume to each air distribution conduit. A method of using the indoor environmental control and air distribution system is also included.

Poerschke, Andrew↗

The impact of simplified window and exhaust fan assumptions on indoor air quality in multifamily buildings

In residential buildings, the indoor air quality can be significantly affected by ventilation measures initiated by occupants, including the operation of windows and in-unit exhaust fans in kitchens and bathrooms. Many simulations simplify these factors by disregarding window opening behaviors and using fixed schedules for exhaust fan operation across all residential units. To estimate the impact of these simplifications in the U.S. context, this study used coupled CONTAM and EnergyPlus models to simulate airflow and contaminant transport in multifamily buildings. The coupled models parametrically varied climate zone, building airtightness, and mechanical ventilation system types. The study conducted a sensitivity analysis on two key occupant behaviors: (1) operating kitchen and bathroom exhausts on different schedules in individual dwelling units, and (2) scheduling open windows on ground and top floors. The simplified assumptions (i.e. uniform in-unit exhaust fan operation and window operation) had a minimal impact on inter-unit air flow and contaminant transport simulations across a broad range of building air leakage and mechanical ventilation system types. These findings suggest that for buildings with tight construction it is reasonable for most modelling and simulation efforts to ignore the effects of non-uniform exhaust fan operation and window opening.

Occupant behavior↗

Review of Variable Geometry Air-to-Refrigerant Heat Exchangers

Air-to-refrigerant heat exchangers (HXs) are fundamental components to HVAC&R systems and as a result there is an ever-increasing need for performance and packaging improvements. Typically, HX’s are designed in uniform arrangements with the goal of providing the necessary heat transfer for minimal material costs. Recent research on fin tube heat exchangers (FTHX) with variation in one or more key parameters has shown significant potential for increasing heat transfer, reducing pressure losses, and making HXs more resilient to environmental externalities like airflow maldistribution and frost accumulation. In particular, researchers have increased heat transfer by 7.6% and j/f by 16% via non-uniform tube and winglet shapes. Additionally, multiple cases have shown that variable geometry heat exchangers (VGHX) are able to match the performance of conventional HXs with reductions in material mass and envelope volume of up to 33% and 40%, respectively. This paper presents a literature review of VGHXs specifically with regards to non-uniform FTHX’s.

42 ENGINEERING↗

Coupling Mesoscale Budget Components to Large-Eddy Simulations for Wind-Energy Applications

To simulate the airflow through a wind farm across a wide range of atmospheric conditions, microscale models (e.g., large-eddy simulation, LES, models) have to be coupled with mesoscale models, because microscale models lack the atmospheric physical processes to represent time-varying local forcing. Here we couple mesoscale model outputs to a LES solver by applying mesoscale momentum- and temperature-budget components from the Weather Research and Forecasting model to the governing equations of the Simulator fOr Wind Farm Applications model. We test whether averaging the budget components affects the LES results with regard to quantities of interest to wind energy. Our study focuses on flat terrain during a quiescent diurnal cycle. The simulation results are compared with observations from a 200-m tall meteorological tower and a wind-profiling radar, by analyzing time series, profiles, rotor-averaged quantities, and spectra. However, while results show that averaging reduces the spatio-temporal variability of the mesoscale momentum-budget components, when coupled with the LES model, the mesoscale bias (in comparison with observations of wind speed and direction, and potential temperature) is not reduced. In contrast, the LES technique can correct for shear and veer. In both cases, however, averaging the budget components shows no significant impact on the mean flow quantities in the microscale and is not necessary when coupling mesocale budget components to the LES model.

17 WIND ENERGY↗

Laser Speckle Pattern Stability in Hypersonic Regimes for Experimental Mechanics and Metrological Studies

Here, an empirical study assessing the suitability of laser speckle patterns for use in experimental mechanics research conducted at hypersonic conditions is presented. Speckle patterns generated via coherent optical scattering from a gold-coated graphite surface inserted into a Mach 10 air stream were collected and analyzed using Computer-Aided Speckle Interferometry using two methodologies: a typical spanwise approach involving increasing temporal span between image pairs, and a sequential approach that utilizes a combination of temporal re-referencing and spatial resampling. Results were characterized for spatial-temporal stability and variance. Our observations demonstrate that optical methods relying on stable and properly formed speckle patterns can be used in a hypersonic regime at various Reynolds numbers and common camera frame rates, but the technique is sensitive to the conditions of the airflow and the processing methodology chosen.

42 ENGINEERING↗