Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ACTIVATION ANALYSIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A laser-induced repetitive fast neutron source applied for gold activation analysis

A laser-induced repetitively operated fast neutron source was developed for applications in laser-driven nuclear physics research. The developed neutron source, which has a neutron yield of approximately 4 Multiplication-Sign 10{sup 5} n/pulse and can be operated up to a pulse repetition rate of 10 Hz, was applied for a gold activation analysis. Relatively strong delayed gamma spectra of the activated gold were measured at 333 keV and 355 keV, and proved the possibility of the neutron source for activation analyses. In addition, the nuclear reactions responsible for the measured gamma spectra of gold were elucidated by the 14 MeV fast neutrons resulting from the D(t,n)He{sup 4} nuclear reaction, for which the required tritium originated from the primary fusion reaction, D(d,p)T{sup 3}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A structure-activity analysis of the variation in oxime efficacy against nerve agents

A structure-activity analysis was used to evaluate the variation in oxime efficacy of 2-PAM, obidoxime, HI-6 and ICD585 against nerve agents. In vivo oxime protection and in vitro oxime reactivation were used as indicators of oxime efficacy against VX, sarin, VR and cyclosarin. Analysis of in vivo oxime protection was conducted with oxime protective ratios (PR) from guinea pigs receiving oxime and atropine therapy after sc administration of nerve agent. Analysis of in vitro reactivation was conducted with second-order rate contants (k{sub r2}) for oxime reactivation of agent-inhibited acetylcholinesterase (AChE) from guinea pig erythrocytes. In vivo oxime PR and in vitro k{sub r2} decreased as the volume of the alkylmethylphosphonate moiety of nerve agents increased from VX to cyclosarin. This effect was greater with 2-PAM and obidoxime (> 14-fold decrease in PR) than with HI-6 and ICD585 (< 3.7-fold decrease in PR). The decrease in oxime PR and k{sub r2} as the volume of the agent moiety conjugated to AChE increased was consistent with a steric hindrance mechanism. Linear regression of log (PR-1) against log (k{sub r2} {center_dot} [oxime dose]) produced two offset parallel regression lines that delineated a significant difference between the coupling of oxime reactivation and oxime protection for HI-6 and ICD585 compared to 2-PAM and obidoxime. HI-6 and ICD585 appeared to be 6.8-fold more effective than 2-PAM and obidoxime at coupling oxime reactivation to oxime protection, which suggested that the isonicotinamide group that is common to both of these oximes, but absent from 2-PAM and obidoxime, is important for oxime efficacy.

60 APPLIED LIFE SCIENCES↗

The simultaneous determination of 20 trace elements in terrestrial, lunar and meteoritic material by radiochemical neutron activation analysis

A radiochemical neutron activation method has been developed and applied to determine the content of 20 trace elements (Ag, Au, Bi, Br, Cd, Co, Cs, Cu, Ga, Ge, In, Ir, Ni, Rb, Re, Sb, Te, Tl, and Zn) in 45 terrestrial, 230 lunar, and 70 meteoritic samples. Results obtained for the U.S.G.S. standard basalt BCR-1 indicate that the inherent precision for most elements is 10% or better. The values obtained for the trace elements investigated are compared to those previously reported in the literature. Data for Type I carbonaceous chondrites show their compositions to be far more uniform than previously supposed. The values obtained for several elements represent significant revisions in the accepted cosmic abundances. These new values include: Zn, 1250; Cd, 1.51; and Ir, 0.72 atoms/million Si atoms. Further results have provided insight into the meteoritic material and accretion of the moon, and give evidence of lunar highland vulcanism.

Keays, R. R.↗

Epithermal Neutron Activation Analysis of the Asian Herbal Plants

Asian medicinal herbs Chrysanthemum (Spiraea aquilegifolia Pall.) and Red Sandalwood (Pterocarpus Santalinus) are widely used in folk and Ayurvedic medicine for healing and preventing some diseases. The modern medical science has proved that the Chrysanthemum (Spiraea aquilegifolia Pall.) possesses the following functions: reducing blood press, dispelling cancer cell, coronary artery's expanding and bacteriostating and Red Sandalwood (Pterocarpus Santalinus) is recommended against headache, toothache, skin diseases, vomiting and sometimes it is taken for treatment of diabetes. Species of Chrysanthemums were collected in the north-eastern and central Mongolia, and the Red Sandalwood powder was imported from India. Samples of Chrysanthemums (branches, flowers and leaves)(0.5 g) and red sandalwood powder (0.5 g) were subjected to the multi-element instrumental neutron activation analysis using epithermal neutrons (ENAA) at the IBR-2 reactor, Frank Laboratory of Neutron Physics (FLNP) JINR, Dubna. A total of 41 elements (Na, Mg, Al, Cl, K, Ca, Sc, V, Cr, Mn, Fe, Co, Ni, Zn, As, Se, Br, Rb, Sr, Zr, Mo, Cd, Cs, Ba, La, Hf, Ta, W, Sb, Au, Hg, Ce, Nd, Sm, Eu, Tb, Dy, Yb, Th, U, Lu) were determined. For the first time such a large group of elements was determined in the herbal plants used in Mongolia. The quality control of the analytical results was provided by using certified reference material Bowen Cabbage. The results obtained are compared to the ''Reference plant? data (B. Markert, 1992) and interpreted in terms of excess of such elements as Se, Cr, Ca, Fe, Ni, Mo, and rare earth elements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-Group Transport Methods for High-Resolution Neutron Activation Analysis

The accurate and efficient simulation of coupled neutron-photon problems is necessary for various radiation detection applications. Examples include the detection of nuclear threats concealed in cargo containers and prompt gamma neutron activation analysis for nondestructive determination of elemental composition of unknown samples. In these applications, high-resolution gamma-ray spectrometers are used to preserve as much information as possible about the emitted photon flux, which consists of both continuum and characteristic gamma rays with discrete energies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Application of artificial neural network to prompt gamma neutron activation analysis for chemical warfare agents identification

The Portable Isotopic Neutron Spectroscopy (PINS) is a commercialized system developed by Idaho National Laboratory (INL) to examine chemical warfare agents (CWA) non-destructively, utilizing Prompt Gamma Neutron Activation Analysis (PGNAA) techniques. The PINS system takes advantage of a high-resolution gamma-ray spectrum from a mechanically-cooled high-purity germanium (HPGe) detector, and gamma-ray peak analysis provides input to its chemical identification logic with a probabilistic decision tree (PDT). The effectiveness of the chemical identification algorithm is determined by the availability of a wide range of data to train the algorithm to identify chemical-fills with accuracy. INL has a collection of gamma-ray spectra of various chemical-fills from the field-deployed PINS systems over the years, and it was envisaged to leverage such a database with the Artificial Neural Network (ANN) technique. Therefore, an ANN-based chemical identification algorithm was developed as an independent verification of the current algorithm. The ANN-based algorithm’s performance was evaluated against the U.S. Army blind test data, and results were presented and discussed in this study.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Quantitative Evaluation of Ion-implanted Arsenic in Silicon by Instrumental Neutron Activation Analysis

Certified reference materials (CRMs) of shallow arsenic implants in silicon are now under development at the National Metrology Institute of Japan (NMIJ). The amount of ion-implanted arsenic atoms is quantified by Instrumental Neutron Activation Analysis (INAA) using research reactor JRR-3 in Japan Atomic Energy Agency (JAEA). It is found that this method can evaluate arsenic amounts of 10{sup 15} atoms/cm{sup 2} with small uncertainties, and is adaptable to shallower dopants. The estimated uncertainties can satisfy the industrial demands for reference materials to calibrate the implanted dose of arsenic at shallow junctions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flux Estimation of a PuBe source using Delayed Gamma Neutron Activation Analysis

For handling and storage of a highly radioactive source, it is necessary to have an accurate knowledge of the radioactive source as well as the neutron flux. Recently, due to radiation safety requirements, a PuBe alpha-neutron source at an activation facility at IIT-Kanpur had to be taken out of its original damaged howitzer and placed inside a new shielded container. While, this effort was successful in reducing the radiation dose, and making the setup safe for laboratory measurements, the new source moderator configuration left the new Pu-Be source spectrum unknown. Therefore, in this work we have used delayed gamma neutron activation analysis (DGNAA) of aluminum, copper, iron, manganese (found in iron), and silver for thermal neutron flux estimation of the Pu-Be neutron source. A series of DGNAA measurements with different samples were carried out to find the value of the average thermal neutron flux of a Pu-Be neutron source at Indian Institute of Technology-Kanpur. The order of the thermal neutron flux is found to be nearly 1.64 x 10{sup 5} excluding aluminum. Upon including aluminum, the value of thermal neutron flux decreases to 1.57x10{sup 5}. We have used common metals (like aluminum, silver, copper and iron) to calculate the thermal neutron flux. The calculated value of the thermal neutron flux is consistent for all the metals except for iron. Iron is giving a value almost four times larger than the average calculated value of the thermal neutron flux using other six samples. The reason is currently being investigated. The DGNAA technique came out to be a very useful technique. Now that we know the thermal neutron flux of the Pu-Be source, our future work will include improving the safety and shielding calculations for our activation facility at IIT-Kanpur. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Ion Uptake Determination of Dendrochronologically-Dated Trees Using Neutron Activation Analysis

Uptake of metal ions by plan roots is a function of the type and concentration of metal in the soil, the nutrient biochemistry of the plant, and the immediate environment of the root. Uptake of gold (Au) is known to be sensitive to soil pH for many species. Soil acidification due to acid precipitation following volcanic eruptions can dramatically increase Au uptake by trees. Identification of high Au content in tree rings in dendrochronologically-dated, overlapping sequences of trees allows the identification of temporally-conscribed, volcanically-influenced periods of environmental change. Ion uptake, specifically determination of trace amounts of gold, was performed for dendrochronologically-dated tree samples utilizing Neutron Activation Analysis (NAA) technique. The concentration of gold was correlated with known enviironmental changes, e.g. volcanic activities, during historic periods.

54 ENVIRONMENTAL SCIENCES↗