Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ABSORPTIVE INDEX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Soft X-ray spectral observations of low-luminosity active galaxies

The X-ray spectra of a sample of 12 low-luminosity AGNs observed using the solid state spectrometer on the HEAO 2 satellite are investigated. The AGNs discussed here have X-ray luminosities below about 10 to the 44th erg/s, and thus form a sample complementary to the higher luminosity sample discussed by Petre et al. (1984). The spectra are well described by a simple model consisting of a power law, with photon spectral index about 1.7, plus absorption by cold gas. The objects in the sample can be separated into three groups: (1) those whose spectra show no significant absorption; (2) those for which the X-ray source is totally covered by a spatially uniform absorbing medium; and (3) those for which partial covering by 'patchy' absorbers is indicated. Column densities and covered fractions do not correlate systematically with X-ray luminosity. Implications regarding physical conditions in AGNs are discussed.

Reichert, G. A.↗

A ROSAT observation of the transient X-ray pulsar GRO J1008-57

We report results of a brief Target of Oppurtunity observation of the newly discovered transient X-ray pulsar Gamma Ray Observatory (GRO) J1008-57 using the ROSAT Position Sensitive Proportional Counter (PSPC). The observation was performed well into the decline of the source outburst as monitored by the BATSE hard X-ray light curve. The PSPC cleanly detected the source, at a 0.1-2.4 keV flux of 2.3 x 10(exp -11) erg/sq cm/s. A position centroid accurate to 10 arc seconds has been determined. The 0.1-2.4 keV spectrum is best characterized by a flat power law with substantial interstellar absorption. The PSPC photon index and column density are consistent with that measured at higher energy by ASCA; there is no evidence for an additional soft component. Light-curve folding reveals a period of 93.4 s, consistent with that measured at higher energies; the 0.1-2.4 keV folded light curve shows a high pulsed fraction and a strongly double-peaked pulse profile. The spectral and temporal properties of GRO J1008-57 as observed using the PSPC are entirely consistent with a pulsar orbiting a massive (OB) companion.

Petre, R.↗

Performance Properties of Graphite Reinforced Composites with Advanced Resin Matrices

This article looks at the effect of different resin matrices on thermal and mechanical properties of graphite composites, and relates the thermal and flammability properties to the anaerobic char yield of the resins. The processing parameters of graphite composites utilizing graphite fabric and epoxy or other advanced resins as matrices are presented. Thermoset resin matrices studied were: aminecured polyfunctional glycidyl aminetype epoxy (baseline), phenolicnovolac resin based on condensation of dihydroxymethyl-xylene and phenol cured with hexamine, two types of polydismaleimide resins, phenolic resin, and benzyl resin. The thermoplastic matrices studied were polyethersulfone and polyphenylenesulfone. Properties evaluated in the study included anaerobic char yield, limiting oxygen index, smoke evolution, moisture absorption, and mechanical properties at elevated temperatures including tensile, compressive, and short-beam shear strengths. Generally, it was determined that graphite composites with the highest char yield exhibited optimum fire-resistant properties.

Kourtides, Demetrius A.↗

The Flora Mission for Ecosystem Composition, Disturbance and Productivity

Global land use and climate variability alter ecosystem conditions - including structure, function, and biological diversity - at a pace that requires unambiguous observations from satellite vantage points. Current global measurements are limited to general land cover, some disturbances, vegetation leaf area index, and canopy energy absorption. Flora is a pathfinding mission that provides new measurements of ecosystem structure, function, and diversity to understand the spatial and temporal dynamics of human and natural disturbances, and the biogeochemical and physiological responses of ecosystems to disturbance. The mission relies upon high-fidelity imaging spectroscopy to deliver full optical spectrum measurements (400-2500 nm) of the global land surface on a monthly time step at 45 meter spatial resolution for three years. The Flora measurement objectives are: (i) fractional cover of biological materials, (ii) canopy water content, (iii) vegetation pigments and light-use efficiency, (iv) plant functional types, (v) fire fuel load and fuel moisture content, and (vi) disturbance occurrence, type and intensity. These measurements are made using a multi-parameter, spectroscopic analysis approach afforded by observation of the full optical spectrum. Combining these measurements, along with additional observations from multispectral sensors, Flora will far advance global studies and models of ecosystem dynamics and change.

Asner, Gregory P.↗

Determining CDOM Absorption Spectra in Diverse Aquatic Environments Using a Multiple Pathlength, Liquid Core Waveguide System

We evaluated the accuracy, sensitivity and precision of a multiple pathlength, liquid core waveguide (MPLCW) system for measuring colored dissolved organic matter (CDOM) absorption in the UV-visible spectral range (370-700 nm). The MPLCW has four optical paths (2.0, 9.8, 49.3, and 204 cm) coupled to a single Teflon AF sample cell. Water samples were obtained from inland, coastal and ocean waters ranging in salinity from 0 to 36 PSU. Reference solutions for the MPLCW were made having a refractive index of the sample. CDOM absorption coefficients, aCDOM, and the slope of the log-linearized absorption spectra, S, were compared with values obtained using a dual-beam spectrophotometer. Absorption of phenol red secondary standards measured by the MPLCW at 558 nm were highly correlated with spectrophotometer values and showed a linear response across all four pathlengths. Values of aCDOM measured using the MPLCW were virtually identical to spectrophotometer values over a wide range of concentrations. The dynamic range of aCDOM for MPLCW measurements was 0.002 - 231.5 m-1. At low CDOM concentrations spectrophotometric aCDOM were slightly greater than MPLCW values and showed larger fluctuations at longer wavelengths due to limitations in instrument precision. In contrast, MPLCW spectra followed an exponential to 600 nm for all samples.

Miller, Richard L.↗

Determining CDOM Absorption Spectra in Diverse Coastal Environments Using a Multiple Pathlength, Liquid Core Waveguide System. Measuring the Absorption of CDOM in the Field Using a Multiple Pathlength Liquid Waveguide System

We evaluated the accuracy, sensitivity and precision of a multiple pathlength, liquid core waveguide (MPLCW) system for measuring colored dissolved organic matter (CDOM) absorption in the UV-visible spectral range (370-700 nm). The MPLCW has four optical paths (2.0, 9.8, 49.3, and 204 cm) coupled to a single Teflon AF sample cell. Water samples were obtained from inland, coastal and ocean waters ranging in salinity from 0 to 36 PSU. Reference solutions for the MPLCW were made having a refractive index of the sample. CDOM absorption coefficients, a(sub CDOM), and the slope of the log-linearized absorption spectra, S, were compared with values obtained using a dual-beam spectrophotometer. Absorption of phenol red secondary standards measured by the MPLCW at 558 nm were highly correlated with spectrophotometer values (r > 0.99) and showed a linear response across all four pathlengths. Values of a(sub CDOM) measured using the MPLCW were virtually identical to spectrophotometer values over a wide range of concentrations. The dynamic range of a(sub CDOM) for MPLCW measurements was 0.002 - 231.5/m. At low CDOM concentrations (a(sub 370) < 0.1/m) spectrophotometric a(sub CDOM) were slightly greater than MPLCW values and showed larger fluctuations at longer wavelengths due to limitations in instrument precision. In contrast, MPLCW spectra followed an exponential to 600 nm for all samples. The maximum deviation in replicate MPLCW spectra was less than 0.001 absorbance units. The portability, sampling, and optical characteristics of a MPLCW system provide significant enhancements for routine CDOM absorption measurements in a broad range of natural waters.

Miller, Richard L.↗

Third Order Optical Nonlinearity of Colloidal Metal Nanoclusters Formed by MeV Ion Implantation

We report the results of characterization of nonlinear refractive index of the composite material produced by MeV Ag ion implantation of LiNbO(sub 3) crystal (z-cut). The material after implantation exhibited a linear optical absorption spectrum with the surface plasmon peak near 430 nm attributed to the colloidal silver nanoclusters. Heat treatment of the material at 500 deg C caused a shift of the absorption peak to 550 nm. The nonlinear refractive index of the sample after heat treatment was measured in the region of the absorption peak with the Z-scan technique using a tunable picosecond laser source (4.5 ps pulse width).The experimental data were compared against the reference sample made of MeV Cu implanted silica with the absorption peak in the same region. The nonlinear index of the Ag implanted LiNbO(sub 3) sample produced at five times less fluence is on average two times greater than that of the reference.

Sarkisov, S. S.↗

Optical properties of CO2 ice and CO2 snow in the ultraviolet, visible, and infrared

The project was to measure the optical constants of CO2 ice in the spectral regions of weak absorption. Many previous measurements had been made by others in the strong absorption bands, but the weak regions had been poorly measured or not measured at all. In these regions the emissivity of CO2 frost and CO2 clouds is quite sensitive to particle sizes and to the value of the absorption coefficient, so the new measurements will have applications to energy budget and remote sensing of the Martian surface and atmosphere. During the time period covered by this grant, a method was developed for growing clear crystals of CO2, 4 cm in length. An apparatus was constructed for accurate measurement of spectral transmission through these crystals, for wavelengths 0.18-3.8 micrometers, covering the near-ultraviolet, visible, and near-infrared regions, bounded by the strong ultraviolet absorption and the 4.3-micrometer band. Our new best estimate of the spectral absorption coefficient (expressed as imaginary refractive index) is shown. It is a composite result of many measurements on dozens of crystals. Now that we have a good dataset for the shortwave absorption spectrum, the focus of the research has moved to the thermal infrared, for which a Fourier Transform interferometer has been adapted for use with C02-ice crystals.

Warren, Stephen↗

Spectroscopy of candidate young globular clusters in NGC 1275

We present spectra of the brightest member of the population of compact blue objects discovered in the peculiar galaxy NGC 1275 by Holtzman et al. (1992) using Hubble Space Telescope images. These spectra show strong Balmer absorption lines like those observed in A-type stars, as expected if the object is a young globular cluster. The age estimated from the strength of the Balmer lines is about 0.5 Gyr, although ages ranging from 0.1 Gyr to 0.9 Gyr cannot be confidently excluded given current models of stellar populations. If these estimated ages are adopted for the young cluster population of NGC 1275 as a whole, the fading predicted by stellar populations models gives a luminosity function which is consistent with that of the Galactic globular cluster system convolved with the observational selection function for the NGC 1275 system. We also use the equivalent widths of the Mg b and Fe 5270 features to constrain the metallicity of the young cluster. Combining these absorption-line widths with the age estimates from the Balmer lines and stellar population models, we find a metallicity of roughly solar, based on the Mg b index, and somewhat higher for the Fe 5270 index. The radial velocity of the absorption lines of the cluster spectrum is offset from the emission lines of the galaxy spectrum at the same position by - 130 km/s, providing further evidence for the identification of the object as a global cluster and opening up the future possibility of studying the kinematics of young cluster systems. The discovery of objects with the characteristics of young globular clusters in NGC 1275, which shows evidence of a recent interaction or merger, supports the hypothesis that galaxy interactions and mergers are favorable sites for the formation of globular clusters.

Zepf, Stephen E.↗

X-ray observations of the Vela pulsar: Statistics and spectrum

The Vela pulsar was observed in the range 2-60 keV by the GSFC proportional counter experiment onboard OSO-8 with temporal resolution sufficient to make possible a sensitive search for pulsed X-rays at the radio pulsar period. A statistical analysis yielded 8 per cent as the 3 sigma upper limit on the pulsed fraction. The energy spectrum is fit well by a structureless power law with number index 2.21 + or - 0.2 and absorption by a hydrogen column density of N sub H equals 2.9 + or - 2.0 times ten to the twenty-second power per sq.cm.

Pravdo, S. H.↗

ANS results on X-ray binaries

A short description is given of the Astronomical Netherlands Satellite ANS and the X-ray instruments of the Space Research Laboratory in Utrecht. ANS observed in February 1975 a soft _ KeV) X-ray flux in Her-x-I during the 'off'-state with an intensity of a factor I0 lower than observed previously in the 'on'-state. The measured uncorrected intensity is (1.1 ± 0.2)10^(-11) ergs/sq.cm sec in 0.2 - 0.28 keV at earth. The ANS observations on Cyg-X-I are summarized. Duping the May 75 flaring state a very high intensity at 0.5 keV is measured consistent with a power-law Ph0ton-spectrum with index 3.5 and an interstellar absorption of 7.10^(21) atoms/sq.cm, but not consistent with spectra that show an additional cut-off below 1KeV and an absorption of 7 10^(21) atoms/sq.cm. Intensity changes on a time scale of minutes, as observed in Cyg-X-1 lowstate, are not observed during the flaring state.

J. Heise↗

X-ray observations of the Vela pulsar - Statistics and spectrum

The Vela pulsar (3U 0833-45) was observed in the range 2-60 keV by a proportional-counter experiment on board OSO-8 with temporal resolution sufficient to make possible a sensitive search for pulsed X-rays at the radio pulsar period. A statistical analysis yielded 8 percent as the 3-sigma upper limit on the pulsed fraction. The energy spectrum is fitted well by a structureless power law with number index 2.2 (+ or - 0.2) and absorption by a hydrogen column density of 2.9(+ or - 2.0) by 10 to the 22nd power per sq cm.

Pravdo, S. H.↗

An optical burst from the star identified with the X-ray source 2S1254-690

High time-resolution photometry of the proposed optical counterpart (Star 30) of the X-ray source 2S1254-690 is reported here. An event of high statistical significance was observed from the star that has all the temporal characteristics of an X-ray burst (see, for example, ref. 3). 2S1254-690 has not previously been identified as an X-ray burst source, but its optical counterpart shows properties in common with this class of objects. We also derive the X-ray spectrum of 2S1254-690 using data obtained with the HEAO 1 satellite. The spectrum can be fit in the energy range 0.18-30 keV by a power law of photon index -2.5, modified by interstellar absorption.

Mason, K. O.↗

Hydrogenated amorphous silicon deposited by ion-beam sputtering

Hydrogenated amorphous silicon films 1/2 to 1 micron thick were deposited on metal and glass substrates using ion-beam sputtering techniques. The 800 eV, 2 mA/sq cm beam was a mixture of argon and hydrogen ions. The argon sputtered silicon from a pure (7.6 cm) single crystal wafer, while the hydrogen combined with the sputtered material during the deposition. Hydrogen to argon pressure ratios and substrate temperatures were varied to minimize the defect state density in the amorphous silicon. Characterization was done by electrical resistivity, index of refraction and optical absorption of the films.

Lowe, V. E.↗

Scandium oxide antireflection coatings for superluminescent LEDs

For an employment of laser diodes as superluminescent LEDs (SLDs) or amplifiers, the facets of the diodes must be coated with antireflection films. In the work reported, scandium oxide was evaporated from an e-beam source onto Supersil II fused silica substrates. The obtained samples were used for measurements of absorption and reflectivity. Results of index measurements on e-beam evaporated films are presented. It is shown that excellent coatings with reflectivities of 0.00025 can be obtained using these films. Attention is given to the refractive indices for scandium oxide films as a function of wavelength, the power output vs current for laser before coating and after coating with Sc2O3.

Ladany, I.↗