Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “90”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Program operational summary: Operational 90 day manned test of a regenerative life support system

An operational 90-day manned test of a regenerative life support system was successfully completed. This test was performed with a crew of four carefully selected and trained men in a space station simulator (SSS) which had a two gas atmosphere maintained at a total pressure of 68.9, 10 psia, and composed of oxygen at a partial pressure of 3.05 psia with nitrogen as the diluent. The test was planned to provide data on regenerative life support subsystems and on integrated system operations in a closed ecology, similar to that of a space station. All crew equipment and expendables were stored onboard at the start of the mission to eliminate the need for pass-in operations. The significant accomplishments of the test, some of the pertinent test results, some of the problem areas, and conclusions are presented.

Jackson, J. K.↗

A model for analysis of the temperature field downstream of a heated jet injected into an isothermal crossflow at an angle of 90 deg

The temperature distribution downstream of a heated jet entering an isothermal crossflow at an angle of 90 deg is predicted using two conduction models with energy sources above the point of injection, in one case a point source and in the second a line source. The models use effective turbulent diffusivities that are determined empirically from previous measurements. Temperatures predicted by the models are compared to experimental results.

Eriksen, V. L.↗

Seventeen Ketogenic steroids excretion in crewmen in a 90-day manned test of an advanced regenerative life support system

Seventeen KGS (17-Ketogenic steroids) and Na/K were determined in 19 urine specimens collected by each of 4 crewmen during the 90-day test. The specimens represented 10% aliquots of 24-hour collections stored frozen onboard the simulator until passthrough. Electrolytes were analyzed immediately after sample passthrough while the steroids were determined post-test on aliquots of the original sample held at 203 K. Steroid data was corrected for body weight and also for analytical variation in the laboratory urine pool control. Long-term nonspecific responses to low-level stress appear to be reflected by the individual and group mean 17-KGS excretion patterns. The first 39 and the last 20 days of the test were significantly different--and presumably more stressful to the crew--than the period from days 39 to 67. Reduction of adrenocortical function during the mid-test phase is attributed to either an adaptation to chronic or intermittent stress or was the result of an actual reduction in the operational demands of the test during this time. Most remarkable of the metabolic findings is the prevalance of high Na/K ratios and an abrupt peak on day 74 for all 4 crewmen.

Myers, D. J.↗

Training and certification program of the operating staff for a 90-day test of a regenerative life support system

Prior to beginning a 90-day test of a regenerative life support system, a need was identified for a training and certification program to qualify an operating staff for conducting the test. The staff was responsible for operating and maintaining the test facility, monitoring and ensuring crew safety, and implementing procedures to ensure effective mission performance with good data collection and analysis. The training program was designed to ensure that each operating staff member was capable of performing his assigned function and was sufficiently cross-trained to serve at certain other positions on a contingency basis. Complicating the training program were budget and schedule limitations, and the high level of sophistication of test systems.

Source record↗

Facilities and support systems for a 90-day test of a regenerative life support system

A 90-day test is reported of a regenerative life support system which was completed in a space station simulator. The long duration of the test and the fact that it was manned, imposed rigid reliability and safety requirements on the facility. Where adequate reliability could not be built into essential facility systems, either backup systems or components were provided. Awareness was intensified by: (1) placing signs on every piece of equipment that could affect the test, (2) painting switches on all breaker panels a bright contrasting color, (3) restricting access to the test control area, and (4) informing personnel in the facility (other than test personnel) of test activities. It is concluded that the basic facility is satisfactory for conducting long-duration manned tests, and it is recommended that all monitor and alarm functions be integrated into a single operation.

Malin, R. L.↗

Space shuttle: Aerodynamic characteristics of cone-cylinder-flare-fin configurations at Mach numbers of 1.96, 2.74, and 4.96 and angles of attack from 50 to 90 degrees

A 0.00227-scale parametric model of an LMSC/MSFC water recoverable booster was tested in the MSFC 14 x 14-inch trisonic wind tunnel. The purpose of the test was to obtain high angle of attack force and static stability data which could be used by MSFC in preliminary design and aerodynamic trade studies. These data were obtained using six-component internal strain gauge balances. One hundred forty-four different geometrical combinations were possible as all model parts were interchangeable (three nose cones, three cylinder lengths, four flare sections and three sets of fins, plus a no-fin case in combination with the other components). However, due to tunnel occupancy limitations, only the most representative combinations were tested. All configurations investigated were tested at Mach 1.96, 2.74 and 4.96 with data obtained at angles of attack from 50 degrees to 90 degrees and at angles of sideslip from -10 degrees to +10 degrees (at an angle of attack of 60 degrees).

Bradley, D.↗

Dynamic stability derivatives at angles of attack from minus 5 deg to 90 deg for a variable-sweep fighter configuration with twin vertical tails

An investigation was conducted in the Langley full-scale tunnel to determine the dynamic stability derivatives in pitch, roll, and yaw over an angle-of-attack range of -5 deg to 90 deg for a variable-sweep fighter configuration with twin vertical tails. The study consisted of forced-oscillation tests of a 1/10-scale model of the airplane at a Reynolds number of 0.4 million based on the reference wing mean aerodynamic chord. Tests were conducted for wing sweep angles of 22 deg, 35 deg, 50 deg, and 68 deg, and the effects of the vertical and horizontal tails, wing leading-edge slats, nose-mounted canards, and frequency of the oscillation were also evaluated.

Grafton, S. B.↗

Analysis of fungal type isolates taken from a 90-day manned test of an advanced regenerative life support system

Fungal-like cultures isolated before, during, and after the 90-day test from samples of space station simulator (SSS) atmosphere, surfaces, subsystem componets, and crew dermal sites were identified to genus. Out of the original 525 isolates, approximately 80% were classified as bacteria. Laboratory methods (culture media, moisturization, and incubation temperatures) favored the recovery of medically significant bacteria rather than fungi. Therefore, fungal isolates were mostly, nonfastidious types which are ubiquitous in soil and air and commonly contaminate laboratory cultures of pathogens. Predominant isolates were species of Aspergillus, Penicillium, Pullularia, Rhodotorula, and various yeasts. No instances of fungal proliferation were observed; test data reflect the survival of environmental types indigenous to the SSS pretests.

Sofios, M.↗

Visual motor response of crewmen during a simulated 90 day space mission as measured by the critical task battery

In order to test various components of a regenerative life support system and to obtain data on the physiological and psychological effects of long-duration exposure to confinement in a space station atmosphere, four carefully screened young men were sealed in space station simulator for 90 days. A tracking test battery was administered during the above experiment. The battery included a clinical test (critical instability task) related to the subject's dynamic time delay, and a conventional steady tracking task, during which dynamic response (describing functions) and performance measures were obtained. Good correlation was noted between the clinical critical instability scores and more detailed tracking parameters such as dynamic time delay and gain-crossover frequency. The comprehensive data base on human operator tracking behavior obtained in this study demonstrate that sophisticated visual-motor response properties can be efficiently and reliably measured over extended periods of time.

Allen, R. W.↗

Models of earth's atmosphere (90 to 2500 km)

This monograph replaces a monograph on the upper atmosphere which was a computerized version of Jacchia's model. The current model has a range from 90 to 2500 km. In addition to the computerized model, a quick-look prediction method is given that may be used to estimate the density for any time and spatial location without using a computer.

Source record↗