Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “73 NUCLEAR PHYSICS AND RADIATION PHYSICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

New Cross Section Measurements and Evaluations of Zirconium Isotopes [Slides]

This presentation gives a look to new cross section measurements and evaluations of Zirconium (Zr) isotopes. This lecture includes highlights of accomplishments made in 2022. Additionally, it explains the motivation for investigation, new measurements, and re-evaluation of the Zr isotopes. This presentation concludes with a preliminary evaluation result from RPI 90 Zr evaluation and preliminary results from Eigenvalue sensitivity study on Zr sensitive critical benchmark experiments.

07 ISOTOPE AND RADIATION SOURCES↗

Fast Neutron Evaluations for Advanced Lead Systems [Slides]

This presentation touches on fast neutron evaluations for advanced lead systems. This lecture covers project goals to evaluate lead (Pb) isotopes with a focus on improving predictive capabilities of fast systems. Additionally, the project sets out to benchmark available critical and shielding experiments with sensitivity to Pb and utilize RPI Quasi-Differential Scattering experiment for scattering reactions. This project will perform Resolved Resonance Region (RRR) and fast region evaluations for natural Pb isotopes with differential data on EXchange FORmat for experimental numerical nuclear reaction data (EXFOR) and ultimately will submit evaluations to the ENDF/B-VIII.1 library.

07 ISOTOPE AND RADIATION SOURCES↗

Neutron Capture and Transmission Measurements and Evaluation of 54 Fe at the RPI LINAC [Slides]

This presentation covers neutron capture and transmission measurements and evaluation of 54 Fe (Iron) at the Rensselaer Polytechnic Insitute (RPI) Linear Accelerator (LINAC). Presentation conclusions find that 54 Fe is near its conclusion, covariance matrix generation is needed for both experiments before data is made available and released (Completion by April 2023). RPI will be conducting a full Resolved Resonance Region (RRR) evaluation following release of data (Completion by September 2023). Additionally, the neutron beam imager shows promise in providing an easy way to align samples in the most intense part of the neutron beam and there will be a new evaluation that will offer improvements in crit safety, shielding, and stellar applications.

07 ISOTOPE AND RADIATION SOURCES↗

R -Matrix Analysis and Statistical Properties of Dysprosium Isotopes in the Neutron Energy Ranges Up To A Few Kev

In support of the Nuclear Criticality Safety Program, a set of evaluated resonance parameters was generated for seven dysprosium isotopes in the neutron energy range from thermal up to a few keV. The evaluation methodology used the Reich-Moore approximation to fit, with the R-matrix code SAMMY, the high-resolution capture and transmission measurements on natural and enriched samples recently performed at the Rensselaer Polytechnic Institute Gaerttner LINear ACcelerator facility. Additional transmission data measured on enriched samples by Liou at the Columbia University Nevis synchrocyclotron in the mid-seventies were used to gauge the neutron widths above 15 eV. Thermal constants such as absorption and (in)coherent scattering cross sections and corresponding scattering lengths were calibrated to the National Institute of Standards and Technology’s compilation except for 161,164 Dy isotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Measurement of Plutonium Ratios for CRM 137A Recertification

This report documents the analytical methodologies used by the Chemical and Isotopics Mass Spectrometry (CIMS) Group at the US Department of Energy’s Oak Ridge National Laboratory (ORNL) for plutonium isotopic ratio characterizations on purified ~1 mg units prepared by Lawrence Livermore National Laboratory (LLNL) from a mother solution created from an existing 250 mg unit of certified reference material (CRM) 137. The analytical processes described are designed to maintain traceability of the final certified attributes and to eliminate sources of systematic bias for the measurements described. The measurands for certification are the plutonium isotope ratios: 238 Pu/ 239 Pu, 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu. The preparation and analytical process included the following activities: Preparation of reference materials to be used as calibrants to establish traceability to the SI unit of mass for the isotopic analyses and quality controls. For the plutonium isotopic analyses, CRM 128 (a CRM comprising equal atoms of 239 Pu and 242 Pu) was used as the primary calibrant; Each CRM 137A unit was reconstituted using dilute high-purity HNO3. From each, seven replicates were distributed for the isotopic characterizations by thermal ionization mass spectrometry (TIMS) using the total evaporation (TE) method for isotope ratio measurements and MC-ICP-MS using a dynamic peak hooping method for secondary isotope ratio measurements; Due to time delay in the analyses from the last purification of the original CRM 137 mother solution by LLNL, an aliquot of the three provided plutonium units was purified using Eichrom TEVA separation methods to remove americium in-growth and uranium impurities; Minimally corrected data were reported from each analysis using reporting templates provided by the New Brunswick Laboratory Program Office (NBL PO) for the specific methods used for isotopic measurements. In addition, a copy of the instrument exports, Excel templates for isotopic data corrections, and the uncertainty budgets completed with the GUM Workbench software package were submitted to NBL PO.

07 ISOTOPE AND RADIATION SOURCES↗

Fitting $\overline{ν}$ for Minor Pu Isotopes

After successful fitting of prompt ν for 235 U, 238 U, and 239 Pu(n,f) using CGMF, we have moved on to the minor plutonium isotopes. Minor isotopes pose a greater challenge both because there is less data available and we do not, by default, have parametrizations in CGMF already. Initially, we had planned to mitigate these challenges—and provide consistency within CGMF—by taking a stepped approach to the optimization. Continuing from the 239 Pu work, we would then fit 241Pu(n,f) $\overline{ν}$, where there is also a number of experimental measurements, keeping consistency between the parameters that are included in the calculation for 239 Pu and 241 Pu. With these parametrizations settled, we could consistently optimize 240 Pu(n,f) $\overline{ν}$. Following that step, we would move on to 242 Pu(n,f) (and increasing neutron number) and 238 Pu(n,f) (and decreasing neutron number). By including the fissioning systems in this manner, we should be able to minimize the unknown parameters in CGMF. We were also able to develop systematics for the CGMF input parameters along the Pu isotopic chain. However, after studies in the beginning of FY23, where we found reasonable agreement between CGMF and experimental prompt neutron multiplicities for 238−242 Pu, using a compound mass dependent parametrization from, and from discussions with I. Stetcu and P. Talou, we instead performed the evaluation of all five isotopes simultaneously. For all parameters in CGMF, they are either the same for each compound nucleus, or have a dependence on the compound mass. The details of these updates are given in. This report builds upon those details. In this short report, we first give an example of how we have updated CGMF to include 240 Pu(n,f) and 242 Pu(n,f), keeping consistency with the current 239 Pu and 241 Pu calculations, but without rigorous optimization (Sec. 2). Then, we will show in Section 3 what experimental data exist for the various isotopes to provide some insight into why 241 Pu and 239 Pu are used as anchor points. The evaluation is detailed in Section 4, and the comparison between CGMF calculations using the evaluated parameters and other prompt observables besides average neutron multiplicity are discussed in Section 2.2. Finally, we present conclusions and future work in Section 5.

07 ISOTOPE AND RADIATION SOURCES↗

Comparison of the sensitivity of 236 U measurements in environmental samples by MC-ICP-MS and ATONA based high precision U TIMS measurements

The ATONA project is focused upon exploring the improvements in uranium isotope ratio measurements by thermal ionization mass spectrometry (TIMS) provided by a new, capacitor-based, amplifier technology. These “ATONA” Faraday amplifiers (Isotopx Ltd, UK) promise accurate, low-noise measurements of very small signals (< 1 femto-amp) in a traditional Faraday cup, which was only previously possible using an ion counter. This report outlines a series of experiments that were performed to assess the performance of the system in samples that test our rapid analysis procedures, and then compare the results against other mass spectrometry techniques currently available for environmental analyses. The following major goals were achieved: (1) illustrated the importance of 236 U measurements for the screening and analysis of environmental samples; (2) improved sensitivity for 236 U, and then identified 236 U in the 4350B standard at ultra-trace levels (3) Provided comparison of the 236 U sensitivity to multi-collector inductively coupled mass spectrometry techniques (4) Illustrated high TRL for the ATONA based measurement technique. This completes the reporting requirements for task 4 in the project LCP and highlights the utility of the system to make highly sensitive 236 U measurements in programmatically relevant sample matrices and at relevant uranium concentrations.

07 ISOTOPE AND RADIATION SOURCES↗

Report on New and Upgraded National User Facilities in Basic Energy Sciences

On December 1, 2023, the Director of the of the Office of Science (SC) charged all the Department of Energy Office of Science Federal Advisory Committees to respond to look toward the scientific horizon and identify what new or upgraded facilities will best serve the SC community needs in the next ten years (2024-2034). This report by the Basic Energy Sciences Advisory Committee (BESAC) assess facilities for the Basic Energy Sciences (BES) program.

07 ISOTOPE AND RADIATION SOURCES↗

Improvements to the 115g/115m Cd Nuclear Data

Repeated measurements of the isotope 115m Cd by Los Alamos National Laboratory (LANL), Pacific Northwest National Laboratory (PNNL), and Atomic Weapons Establishment (AWE) have revealed a consistent discrepancy between beta and gamma counting. This suggests that a significant disparity exists between the true value of the isotope’s gamma-ray branching ratios and the values reported by the National Nuclear Data Center (NNDC). Enriched 114 Cd was irradiated using thermal neutrons to produce a high-purity 115m/g Cd source for counting and analysis using traditional singles gamma-ray spectroscopy, liquid scintillation counting, gas-proportional counting, and analysis using the new Gamma-Alpha-Beta-Gamma (GABγ) and Gamma-Alpha-Beta Radio-Isotope EvaLuator (GABRIEL) coincidence detection systems. Using the D-T fusion generated neutrons, reduces the wait time required to let the short-lived 115Cd ground state decay away by leveraging the 1:1 production ratio of the ground and metastable state of 115 Cd from the 115 In (n,p) reaction relative to the 10:1 production ratio of the ground and metastable isotopes of 115 Cd by thermal neutron capture on 114 Cd. However, the much higher flux in from the Washington State University TRIGA reactor is a more rapid method of production of 115m/gCd but requires access to enriched 114 Cd. High purity 115m/g Cd samples were analyzed on regular intervals over a period of 140-days. The activity of 115m Cd measured by beta and gamma show a clear discrepancy using the current best known gamma-ray decay branching ratios. Based on these observations and measurements, a set of new branching ratio recommendations have been produced using conventional counting techniques and the advanced GAB? and GABRIEL instruments.

07 ISOTOPE AND RADIATION SOURCES↗

A Robust Assessment of High-Precision Plutonium Isotopic Analysis by Thermal Ionization Mass Spectrometry [Slides]

TIMS at SRNL • SRNL consolidated analytical laboratories and services into one area – loss of TIMS capability during relocation. • SRNL installed a new Thermo Scientific TRITON Plus TIMS in our Category II Nuclear Facility to re-establish the lab’s TIMS capabilities in Feb. 2024. • Allows for handling, preparation, purification, and analysis of high-level radiological materials within a single location • Pu and U isotopic composition and assay measurement qualification have been priority since installation. • Once the instrument has been qualified, this capability will support internal and external customers.

07 ISOTOPE AND RADIATION SOURCES↗

Radiation Dose Modeling for Niowave’s Accelerator Driven Uranium Target Assembly 3

Molybdenum-99 is a high-value radionuclide commonly used for medical purposes within the United States. The National Nuclear Security Administration (NNSA) seeks to reliably produce the radioisotope 99 Mo without the use of highly enriched uranium. NNSA’s Office of Material Management and Minimization (M3) provides funding and government laboratory expertise to private companies to expedite the production process domestically and currently funds designs that use low-enriched uranium or other 99 Mo production pathways. Several production designs are being explored across the industry, including uranium fission and photonuclear conversion of 100 Mo targets. Niowave Inc. seeks to produce 99 Mo via a high-energy electron accelerator that strikes a lead-bismuth eutectic target that ultimately produces a consistent neutron flux. The neutron flux then interacts in a subcritical reactor core configuration to produce fission in low-enriched or natural uranium targets. These fissionable targets are then processed to extract 99 Mo. The purpose of this work is to estimate the neutron and photon dose response across Niowave’s proposed facility for worker safety during operation. Owing to the size of the proposed Niowave facility and necessary shielding, unbiased Monte Carlo radiation transport is impractical, and variance reduction methods are required. This work focuses on the weight window variance reduction method to produce high confidence dose response results within a Monte Carlo radiation transport code. Specifically, an adjoint-informed weight window methodology was created to improve the dose response estimates for accelerator-driven subcritical reactor designs. This adjoint-informed methodology was implemented for Niowave’s proposed design and improved dose results at far-field locations across the facility. Acceptable dose rate contours for the proposed facility were generated across the facility and are presented in this work.

07 ISOTOPE AND RADIATION SOURCES↗

Consistent $\overline{ν}$ evaluation for minor U isotopes with $\tt{CGMF}$

Following several successful prompt $\overline{ν}$ evaluations using $\tt{CGMF}$, including consistent evaluations for minor Pu isotopes, we detail in this report our efforts to perform a consistent $\overline{ν}$ evaluation for minor U isotopes during FY25. Although we have not yet produced a finalized evaluation, we present the progress that we have made towards such an evaluation for 232,233,234,236,237,239 U prompt $\overline{ν}$. Our milestone explicitly calls out evaluations for 233 U, 234 U, and 236 U, however, to better constrain the model with reliable experimental $\overline{ν}$ data, we also include 235 U and 238 U in the evaluation procedure. Then, we additionally produce evaluations for 232 U, 237 U and 239 U $\overline{ν}$ as a byproduct. Elsewhere, we will report our efforts on a stand-alone 233 U $\overline{ν}$ evaluation. This report is organized in the following manner. In Sec. 2, we briefly outline the updates to CGMF that were needed to be able to calculate all of these minor U fission reactions. The experimental data overview is given in Sec. 3. The evaluation methodology and results are presented in Secs. 4 and 5, respectively. Finally, we conclude and outline work for FY26 in Sec. 6.

07 ISOTOPE AND RADIATION SOURCES↗

Novel Methods to Produce an Argon-37 Standard

The purpose of this research was to produce a measurable quantity of radioactive argon-37 through photonuclear production methods. The detection of argon-37, above background levels, uniquely and clearly indicates the underground detonation of a nuclear device.

07 ISOTOPE AND RADIATION SOURCES↗

Novel Methods to Produce an Argon-37 Standard

This poster describes details of a Laboratory Directed Research and Development project to produce and measure argon-37 for nuclear explosion detection.

07 ISOTOPE AND RADIATION SOURCES↗

Why Lady Godiva Should be Replaced as the Default Validation Experiment for U-235 Nuclear Data

For the past seven decades the Lady Godiva benchmark (HEU-MET-FAST-001) has been the primary experiment used for 235 U nuclear data validation. The papers associated with large nuclear data library releases such as ENDF/B-VII.1 and ENDF/B-VIII.0 refer to it frequently. The reasons why HEU-MET-FAST-001 has been used as the primary validation experiment for 235 U nuclear data validation will be discussed in the following section. However, as discussed among the benchmark community, the standards associated with International Criticality Safety Benchmark Evaluation Project (ICSBEP) evaluations have changed throughout time; this is subject of the OECD/NEA WPEC (Working Party on Nuclear Criticality Safety) Subgroup 8. HEU-MET-FAST-001 is an older benchmark (issued during the inaugural year of ICSBEP in 1996 with only minor revisions occurring since then) and (along with many of the other benchmarks from this era) does not meet the standards for a modern benchmark. This work explores why HEU-MET-FAST-001 is useful for 235 U nuclear data validation and discusses other alternative validation experiments.

07 ISOTOPE AND RADIATION SOURCES↗

Design Optimization for EUROPA Critical Experiment

The Experiment for Unresolved Region Of Plutonium Actinides (EUROPA) is an integral critical experiment currently being designed to target the intermediate energy region of plutonium. Intermediate energies, those between 0.625 eV - 100 keV, contain the end of resolved and beginning of the unresolved resonance region, making experiments in this energy range prudent for validating the representation of cross sections in this transition region. Below is the preliminary design of the experiment to be performed at the National Criticality Experiments Research Center (NCERC). Experiment optimization required an exhaustive down selection of several moderating, absorbing, and reflecting materials using Particle Swarm Optimization (PSO) in order to achieve maximum sensitivity to the intermediate energy region.

07 ISOTOPE AND RADIATION SOURCES↗

Measurement of ( n, γ ) cross section of 90 Zr [Abstract]

The isotopes of Zr with A = [90, 91, 92, 94] make up more than 97% of naturally occurring Zr and are important to many nuclear applications such as nuclear reactors. One of the attractive qualities of naturally occurring Zr isotopes is that they have a low σγ/σt ratio at most neutron energies, such that they improve the neutron economy in reactors by preferentially scattering neutrons rather than absorbing them. This same quality also presents a challenge to measuring the capture cross section, σγ, of Zr isotopes. The ENDF/B-VIII.0 library has a relative uncertainty of approximately 10-20% for incident neutron energies < 0.1 MeV, and uncertainty greater than 20% for energies > 0.1 MeV for the majority of natural Zr isotopes. This motivated the Nuclear Criticality Safety Program (NCSP) to embark on a campaign to accurately measure and evaluate these isotopes of Zr. Here we will show energy-dependent neutron capture cross section measurements for the first enriched sample to be measured: 90 Zr. The measurements of isotopically enriched samples are being carried out at the Geel Electron Linear Accelerator (GELINA) facility of the Joint Research Center - Geel (JRC-Geel) of the European Union. As isotopic enrichment is a costly process we are careful not to activate any of the samples, as this may hinder future radiation-sensitive measurements. The activation analysis is presented in a report by Brown et al.. Once we were satisfied that the Zr samples would not be activated by the measurements, the 90 Zr sample was fabricated at Oak Ridge National Laboratory (ORNL) and shipped to GELINA. The dimensions of the cylindrical sample are approximately 0.12 cm thick and a radius of 2.5 cm. Since 90 Zr is not chemically reactive to air, bare metallic samples were employed. The sample was measured at a flight path (FP) length of 60 m, using four C 6 D 6 detectors on FP14. The final paper will include experimental details and measured cross section data for 90 Zr compared to current evaluated nuclear data libraries.

07 ISOTOPE AND RADIATION SOURCES↗