Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3D imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Time-resolved 3D imaging of two-phase fluid flow inside a steel fuel injector using synchrotron X-ray tomography

The multiphase flow inside a diesel injection nozzle is imaged using synchrotron X-rays from the Advanced Photon Source at Argonne National Laboratory. Through acquisitions performed at several viewing angles and subsequent tomographic reconstruction, in-situ 3D visualization is achieved for the first time inside a steel injector at engine-like operating conditions. The morphology of the internal flow reveals strong flow separation and vapor-filled cavities (cavitation), the degree of which correlates with the nozzle's asymmetric inlet corner profile. Micron-scale surface features, which are artifacts of manufacturing, are shown to influence the morphology of the resulting liquid-gas interface. The data obtained at 0.1 ms time resolution exposes transient flow features and the flow development timescales are shown to be correlated with in-situ imaging of the fuel injector's hydraulically-actuated valve (needle). As more than 98.5% of the X-ray photon flux is attenuated within the steel injector body itself, we are posed with a unique challenge for imaging the flow within. Time-resolved imaging under these low-light conditions is achieved by exploiting both the refractive and absorptive properties of X-ray photons. The data-processing strategy converted these images with a signal-to-noise ratio of similar to 10 into a meaningful dataset for understanding internal flow and cavitation in a nozzle of diameter 200 mu m enclosed within 1-2 millimeters of steel.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comet Wild 2 Sample Track 3D Images and S-XRF Stereo Maps

The NASA Stardust mission to comet Wild 2 returned to Earth in 2006 with cometary material trapped in aerogel. The cometary particles were captured at a relative velocity of 6.1 km/s, creating three-dimensional (3D) tracks containing void space, compressed aerogel, melted aerogel, and fragmented cometary material. Each track represents a unique hypervelocity impact event. The nature of each track forming event, including the original state of the impactor, is recorded in 3D track morphology and material distribution. Tracks were cut from sampling tiles in thin aerogel “keystones” translucent to optical light.

D. S. Ebel↗

Long-range 3D imaging of highly dynamic objects using the intensity ratios of partial beams of reflected laser light

The procedural aspects of obtaining long-range three-dimensional images of highly dynamic objects using the ratios of partial beam intensities of the reflected laser light are considered. Alongside with the object images, the proposed method simultaneously provides the data on the object relief with high resolution on a set of surface points during a single-pulse location cycle. The high resolving power and speed of the method ensure the efficiency of its application to detecting and recognition of remote highly dynamic objects, including low-dimensional ones, by their 3D characteristics. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dark-field x-ray microscopy for 2D and 3D imaging of microstructural dynamics at the European x-ray free-electron laser

Dark field x-ray microscopy (DXFM) can visualize microstructural distortions in bulk crystals. Using the femtosecond x-ray pulses generated by x-ray free-electron lasers (XFELs), DFXM can achieve sub-μm spatial resolution and <100 fs time resolution simultaneously. In this paper, we demonstrate ultrafast DFXM measurements at the European XFEL to visualize an optically driven longitudinal strain wave propagating through a diamond single crystal. We also present two DFXM scanning modalities that are new to the XFEL sources: spatial 3D and 2D axial-strain scans with sub-μm spatial resolution. With this progress in XFEL-based DFXM, we discuss new opportunities to study multi-timescale spatiotemporal dynamics of microstructures.

47 OTHER INSTRUMENTATION↗

WE-G-207-06: 3D Fluoroscopic Image Generation From Patient-Specific 4DCBCT-Based Motion Models Derived From Physical Phantom and Clinical Patient Images

Purpose: Respiratory-correlated cone-beam CT (4DCBCT) images acquired immediately prior to treatment have the potential to represent patient motion patterns and anatomy during treatment, including both intra- and inter-fractional changes. We develop a method to generate patient-specific motion models based on 4DCBCT images acquired with existing clinical equipment and used to generate time varying volumetric images (3D fluoroscopic images) representing motion during treatment delivery. Methods: Motion models are derived by deformably registering each 4DCBCT phase to a reference phase, and performing principal component analysis (PCA) on the resulting displacement vector fields. 3D fluoroscopic images are estimated by optimizing the resulting PCA coefficients iteratively through comparison of the cone-beam projections simulating kV treatment imaging and digitally reconstructed radiographs generated from the motion model. Patient and physical phantom datasets are used to evaluate the method in terms of tumor localization error compared to manually defined ground truth positions. Results: 4DCBCT-based motion models were derived and used to generate 3D fluoroscopic images at treatment time. For the patient datasets, the average tumor localization error and the 95th percentile were 1.57 and 3.13 respectively in subsets of four patient datasets. For the physical phantom datasets, the average tumor localization error and the 95th percentile were 1.14 and 2.78 respectively in two datasets. 4DCBCT motion models are shown to perform well in the context of generating 3D fluoroscopic images due to their ability to reproduce anatomical changes at treatment time. Conclusion: This study showed the feasibility of deriving 4DCBCT-based motion models and using them to generate 3D fluoroscopic images at treatment time in real clinical settings. 4DCBCT-based motion models were found to account for the 3D non-rigid motion of the patient anatomy during treatment and have the potential to localize tumor and other patient anatomical structures at treatment time even when inter-fractional changes occur. This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc., Palo Alto, CA. The project was also supported, in part, by Award Number R21CA156068 from the National Cancer Institute.

60 APPLIED LIFE SCIENCES↗

Pore system characterization of organic-rich shales using nanoscale-resolution 3D imaging

The Vaca Muerta Shale in Argentina is the first signifcant commercial shale oil/gas play outside of North America. High-resolution 2D/3D imaging of shale rocks for the purpose of establishing their mineralogy, total, and connected porosities has become more and more sophisticated. In this paper, nanoscale-resolution focused ion beam (FIB)-scanning electron microscopy (SEM) nano-tomography was used to obtain images of pore structures within two organic-rich regions of interest (ROIs), selected based on correlative SEM and automated mineralogy maps. Advanced machine learning classification tools were used to segment the images and assign porosities and other components. Pore size distribution and pore connectivity analyzes revealed that about 95% of all the pores, present within the two ROIs, had a diameter of less than approximately 75 nm, and that most of these pores were poorly connected. In a similar fashion, the flow rate distribution analysis showed that pores with diameters of about 150-330 nm contributed to over 50% of the flow capacity of the connected pore systems. These results suggest that although most of the pores typically found in shales have pore diameter smaller than about 100 nm, most of the hydrocarbon production may be carried by a relatively small number of larger connected pores with pore diameter greater than about 150 nm. This research implies that a large portion of the organic-hosted pores (with diameter typically smaller than about 100 nm) may not provide permeable flow pathways for the oil and/or gas migration, and hence may have very little contribution to the hydrocarbon production.

58 GEOSCIENCES↗

Quality Assurance of Serial 3D Image Registration, Fusion, and Segmentation

Radiotherapy relies on images to plan, guide, and assess treatment. Image registration, fusion, and segmentation are integral to these processes; specifically for aiding anatomic delineation, assessing organ motion, and aligning targets with treatment beams in image-guided radiation therapy (IGRT). Future developments in image registration will also improve estimations of the actual dose delivered and quantitative assessment in patient follow-up exams. This article summarizes common and emerging technologies and reviews the role of image registration, fusion, and segmentation in radiotherapy processes. The current quality assurance practices are summarized, and implications for clinical procedures are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time 3D Image Guidance Using a Standard LINAC: Measured Motion, Accuracy, and Precision of the First Prospective Clinical Trial of Kilovoltage Intrafraction Monitoring–Guided Gating for Prostate Cancer Radiation Therapy

Purpose: Kilovoltage intrafraction monitoring (KIM) is a new real-time 3-dimensional image guidance method. Unlike previous real-time image guidance methods, KIM uses a standard linear accelerator without any additional equipment needed. The first prospective clinical trial of KIM is underway for prostate cancer radiation therapy. In this paper we report on the measured motion accuracy and precision using real-time KIM-guided gating. Methods and Materials: Imaging and motion information from the first 200 fractions from 6 patient prostate cancer radiation therapy volumetric modulated arc therapy treatments were analyzed. A 3-mm/5-second action threshold was used to trigger a gating event where the beam is paused and the couch position adjusted to realign the prostate to the treatment isocenter. To quantify the in vivo accuracy and precision, KIM was compared with simultaneously acquired kV/MV triangulation for 187 fractions. Results: KIM was successfully used in 197 of 200 fractions. Gating events occurred in 29 fractions (14.5%). In these 29 fractions, the percentage of beam-on time, the prostate displacement was >3 mm from the isocenter position, reduced from 73% without KIM to 24% with KIM-guided gating. Displacements >5 mm were reduced from 16% without KIM to 0% with KIM. The KIM accuracy was measured at <0.3 mm in all 3 dimensions. The KIM precision was <0.6 mm in all 3 dimensions. Conclusions: Clinical implementation of real-time KIM image guidance combined with gating for prostate cancer eliminates large prostate displacements during treatment delivery. Both in vivo KIM accuracy and precision are well below 1 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗