Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3-He detector electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

On-Orbit Calibration and Performance Assessments of Terra and Aqua Modis Thermal Emissive Bands

Terra and Aqua MODIS have successfully operated for more than 20 and 18 years, respectively, and far exceeded their designed lifetimes of 6 years. MODIS has 36 spectral bands, among which 16 are the thermal emissive bands (TEB) covering a wavelength range from 3.75 to 14.24 μm. Observations from the MODIS TEB have been used to generate a number of data products, such as surface/cloud/atmospheric temperatures, cloud top altitude, and water vapor properties. To a large extent, the quality of the MODIS L1B radiance product has been maintained through the entirety of each mission via extensive on-orbit calibration and validation efforts. MODIS TEB calibration uses a quadratic algorithm and is referenced to an on-board blackbody with its temperature measurements traceable to the NIST standard. We provide an overview of the MODIS instrument operations, key TEB calibration activities, and algorithms used in the latest L1B data Collection 6.1 (C6.1) and describe the TEB on-orbit performance for both Terra and Aqua MODIS. The TEB gain trends have been stable to within 5% over the Terra mission after 2003 under the same electronic configuration, except for bands 27 to 30, and within 3% over the Aqua mission. The Terra MODIS optical crosstalk correction implemented right after launch has been very effective in removing the ghost images in its photoconductive detector bands 32 to 36. Starting from C6.1, an electronic crosstalk correction algorithm has also been applied to the Terra MODIS photovoltaic detector long-wave infrared bands 27 to 30. The noise characterization performance remains stable with most TEB detectors continuously meeting their design requirements. A gradual loss of the Aqua MODIS radiative cooler margin reached its maximum in 2013 and has been slowly recovering since then. On-orbit changes in TEB response versus scan angle are extremely small based on pitch maneuver observations and assessments using vicarious approaches. The remaining challenges in TEB calibration and proposed improvements for the upcoming data collection with L1B data production and reprocessing are discussed.

Terra↗

Electrical NEP in Hot-Electron Titanium Superconducting Bolometers

We are presenting the current progress on the titanium (Ti) hot-electron transition-edge devices. The ultimate goal of this work is to develop a submillimeter Hot-Electron Direct Detector (HEDD) with the noise equivalent power NEP = 10(sup -1) - 10(sup -20) W/Hz(sup 1/2) for the moderate resolution spectroscopy and Cosmic Microwave Background (CMB) studies on future space telescope (e.g., SPICA, SAFIR, SPECS, CMBPol) with cryogenically cooled (approximately 4-5 K) mirrors. Recently, we have achieved the extremely low thermal conductance (approximately 20 fW/K at 300 mK and approximately 0.1 fW/K at 40 mK) due to the electron-phonon decoupling in Ti nanodevices with niobium (Nb) Andreev contacts. This thermal conductance translates into the "phonon-noise" NEP approximately equal to 3 x 10(sup -21) W/Hz(sup 1/2) at 40 mK and NEP approximately equal to 3 x 10(sup -19) W/Hz(sup 1/2) at 300 mK. These record data indicate the great potential of the hot-electron detector for meeting many application needs. Beside the extremely low phonon-noise NEP, the nanobolometers have a very low electron heat capacitance that makes them promising as detectors of single THz photons. As the next step towards the practical demonstration of the HEDD, we fabricated and tested somewhat larger than in Ref.1 devices (approximately 6 micrometers x 0.35 micrometers x 40 nm) whose critical temperature is well reproduced in the range 300-350 mK. The output electrical noise measured in these devices with a low-noise dc SQUID is dominated by the thermal energy fluctuations (ETF) aka "phonon noise". This indicates the high electrothermal loop gain that effectively suppresses the contributions of the Johnson noise and the amplifier (SQUID) noise. The electrical NEP = 6.7 x 10(sup -18) W/Hz(sup 1/2) derived from these measurements is in good agreement with the predictions based on the thermal conductance data. The very low NEP and the high speed (approximately microns) are a unique combination not found in other detectors.

transition-edge sensor↗

Demonstration of Energy-Resolved γ-Ray Detection at Room Temperature by the CsPbCl 3 Perovskite Semiconductor

The detection of gamma-rays at room temperature with high-energy resolution using semiconductors is one of the most challenging applications. The presence of even the smallest amount of defects is sufficient to kill the signal generated from gamma-rays which makes the availability of semiconductors detectors a rarity. Lead halide perovskite semiconductors exhibit unusually high defect tolerance leading to outstanding and unique optoelectronic properties and are poised to strongly impact applications in photoelectric conversion/detection. Here we demonstrate for the first time that large size single crystals of the all-inorganic perovskite CsPbCl 3 semiconductor can function as a high-performance detector for gamma-ray nuclear radiation at room temperature. CsPbCl 3 is a wide-gap semiconductor with a bandgap of 3.03 eV and possesses a high effective atomic number of 69.8. We identified the two distinct phase transitions in CsPbCl 3 , from cubic (Pm-3m) to tetragonal (P4/mbm) at 325 K and finally to orthorhombic (Pbnm) at 316 K. Despite crystal twinning induced by phase transitions, CsPbCl 3 crystals in detector grade can be obtained with high electrical resistivity of similar to 1.7 X 10 9 Ω∙cm. The crystals were grown from the melt with volume over several cubic centimeters and have a low thermal conductivity of 0.6 W m -1 K -1 . The mobilities for electron and hole carriers were determined to similar to 30 cm 2 /(V s). Using photoemission yield spectroscopy in air (PYSA), we determined the valence band maximum at 5.66 +/- 0.05 eV. Under gamma-ray exposure, our Schottky-type planar CsPbCl 3 detector achieved an excellent energy resolution (similar to 16% at 122 keV) accompanied by a high figure-of-merit hole mobility-lifetime product (3.2 x 10 -4 cm 2 /V) and a long hole lifetime (16 mu s). The results demonstrate considerable defect tolerance of CsPbCl 3 and suggest its strong potential for gamma-radiation and X-ray detection at room temperature and above.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and Testing of the Endcap Concentrator ASICs for the CMS High-Granularity Calorimeter Upgrade

A major upgrade of the High-Granularity Calorimeter (HGCAL) in the CMS detector is planned for Long-Shutdown 3 (LS3), currently expected to start in 2026. This upgrade will contain over 6 million channels and the electronics will be required to be low power and to withstand a radiation environment with a High-Energy Hadron flux of 3x10**6 particles per square centimeter per second. The solution to this significant challenge is the two Endcap Concentrator (ECON) ASICs, ECON-T and ECON-D, working in tandem with the HGCROC front-end ASIC. The two ECON ASICs provide critical on-detector data reduction for both the 40 MHz trigger path (ECON-T) and 750 kHz data acquisition path (ECON-D) of the HGCAL. The ASICs are fabricated in 65nm CMOS. They are rad-tolerant to 600 Mrad with low power consumption (<2.5 mW/channel). This presentation will be a comprehensive description of each ECON design, including the infrastructure that they share as well as the elements that make each unique. The presentation will also include functionality and radiation tests for both ASICs, and the first high statistics characterization results from the full production of 75k ECON-D and ECON-T ASICs.

Hoff, James R. [Fermilab] (ORCID:0000000163514592)↗

Use of a Mylar filter to eliminate vacuum ultraviolet pulse pileup in low-energy x-ray measurements

We describe a method to reduce vacuum ultraviolet (VUV) pulse pileup (PPU) in x-ray pulse-height Silicon Drift Detector (SDD) signals. An Amptek FAST SDD, with C1 (Si 3 N 4 ) window, measures bremsstrahlung emitted from PFRC-2 plasma to extract the electron temperature (T e ) and density (n e ). The C1 window has low transmissivity for photons with energy below 200 eV though will transmit some VUV and soft x-ray photons, which PFRC-2 plasmas abundantly emit. Multi-VUV-photon PPU contaminates the interpretation of x rays with energy > 100 eV, particularly in a low-energy exponential tail. The predicted low transmissivity of ~1 μm thick Mylar [polyethylene terephthalate (PET)] to photons of energy <100 eV led to the selection of Mylar as the candidate filter to reduce VUV PPU. Experiments were conducted on an x-ray tube with a graphite target and on a quasi-Maxwellian tenuous plasma (n e ~ 10 9 cm –3 ) with effective temperatures reaching 1500 eV. A Mylar filter thickness of 850 nm is consistent with the results. The Mylar-filter-equipped SDD was then used on the PFRC-2 plasma, showing a substantial reduction in the low-energy x-ray signal, supporting our hypothesis of the importance of VUV PPU. Here, we describe the modeling and experiments performed to characterize the effect of the Mylar filter on SDD measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Concept for a High-Energy Gamma-ray Polarimeter

We present a concept for an imaging gamma-ray polarimeter operating from approx. 50 MeV to approx. 1 GeV. Such an instrument would be valuable for the study of high-energy pulsars, active galactic nuclei, supernova remnants, and gamma-ray bursts. The concept makes use of pixelized gas micro-well detectors, under development at Goddard Space Flight Center, to record the electron-positron tracks from pair-production events in a large gas volume. Pixelized micro-well detectors have the potential to form large-volume 3-D track imagers with approx. 100 micron (rms) position resolution at moderate cost. The combination of high spatial resolution and a continuous low-density gas medium permits many thousands of measurements per radiation length, allowing the particle tracks to be imaged accurately before multiple scattering masks their original directions. The polarization of the incoming radiation may then be determined from the azimuthal distribution of the electron-positron pairs. We have performed Geant4 simulations of these processes to estimate the polarization sensitivity as a function of instrument parameters and event selection criteria.

Bloser, P. F.↗

The JSNS 2 detector

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for oscillations involving a sterile neutrino in the eV 2 mass-splitting range. The experiment will search for the appearance of electron antineutrinos oscillated from muon antineutrinos. The electron antineutrinos are detected via the inverse beta decay process using a liquid scintillator detector. A 1 MW beam of 3 GeV protons incident on a spallation neutron target produces an intense and pulsed neutrino source from pion, muon, and kaon decay at rest. The JSNS detector is located 24 m away from the neutrino source and began operation from June 2020. The detector contains 17 tonnes of gadolinium (Gd) loaded liquid scintillator (LS) in an acrylic vessel, as a neutrino target. It is surrounded by 31 tonnes of unloaded LS in a stainless steel tank. Optical photons produced in LS are viewed by 120 R7081 Hamamatsu 10-inch Photomultiplier Tubes (PMTs). In this study, we describe the JSNS detector design, construction, and operation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improving CdMnTe Detector Performance by Adding 2% of Selenium

About 2% of selenium was added to CdMnTe (CMT) to reveal the role of selenium in CMT material used as a gamma-ray detector. The average etch-pit density (EPD) in a typical 2-in CdMnTeSe (CMTS) wafer was measured to be about 8.3×10 3 cm –2 except for the edge regions, and the radial nonuniformity of the bandgap along the wafer was about 2-meV. The typical mobility-lifetime product of electrons and holes was evaluated to be 3.06×10 –3 cm 2 /V and 3.1×10 –4 cm 2 /V, respectively. The energy resolution of the 122-keV photo-peak for a Co-57 radioactive source with a planar CMTS detector was 5.2%, demonstrating a positive effect associated with adding dilute amounts of Se to CMT. Finally, the enhanced detector performance in a planar CMTS detector is attributed to an improved value of hole mobility-lifetime product in CMTS, which mitigates the adverse hole tailing effect found in CdZnTe (CZT) and CMT detectors.

47 OTHER INSTRUMENTATION↗

Interferometric bunch length measurements of 3 MeV picocoulomb electron beams

We report picosecond bunch length measurements using an interferometric method for a 3 MeV electron beam having bunch charge ranging from 1 to 14 pC. The method senses the single-cycle sub-terahertz (THz) pulse emitted by each electron bunch as coherent transition radiation which, in turn, is analyzed using a Michelson-type interferometer, forming an interferogram that is then processed to yield the nominal electron bunch length. This sub-THz coherent radiation intensity was measured using a quasi-optical detector (QOD) operated at room temperature. This experiment was quite challenging since the divergence angle of the sub-THz pulse emitted by the low-energy electron bunch exceeds ±10°, and its pulse energy at the entrance to the detector was as low as 100 pJ. When compared to a conventional helium-cooled silicon composite bolometer designed for frequencies above 0.5 THz, the QOD provided much better signal-to-noise ratio in the ~80 GHz frequency range, which was critical for the successful measurement of the bunch length.

36 MATERIALS SCIENCE↗

Infrared fiber optic focal plane dispersers

Far infrared transmissive fiber optics as a component in the design of integrated far infrared focal plane array utilization is discussed. A tightly packed bundle of fibers is placed at the focal plane, where an array of infrared detectors would normally reside, and then fanned out in two or three dimensions to individual detectors. Subsequently, the detectors are multiplexed by cryogenic electronics for relay of the data. A second possible application is frequency up-conversion (v sub 1 + v sub 2 = v sub 3), which takes advantage of the nonlinear optical index of refraction of certain infrared transmissive materials in fiber form. Again, a fiber bundle is utilized as above, but now a laser of frequency v sub 1 is mixed with the incoming radiation of frequency v sub 1 within the nonlinear fiber material. The sum, v sub 2 is then detected by near infrared or visible detectors which are more sensitive than those available at v sub 2. Due to the geometrical size limitations of detectors such as photomultipliers, the focal plane dispersal technique is advantageous for imaging up-conversion.

Goebel, J. H.↗

Using Deep Learning Techniques to Search for the MiniBooNE Low Energy Excess in MicroBooNE with > 3$\sigma$ Sensitivity

This thesis describes an analysis developed for the MicroBooNE experiment to investigate an anomalous excess of electron-like events observed in the MiniBooNE detector. The hypothesis investigated here is that the MiniBooNE anomaly represents appearance of electron neutrinos. Using an amalgam of novel Deep Learning and standard algorithmic techniques this analysis reconstructs and identifies a highly pure sample of charged current quasi-elastic muon neutrino and electron neutrino interactions. This thesis describes the steps in the analysis chain and provides data-to-simulation comparisons for each step that establish confidence in the final prediction. When interpreted in the context of a $\nu e$ appearance like model, this analysis predicts a 3.2$\sigma$ sensitivity to exclude a standard model fluctuation which would appear as a MiniBooNE like anomaly using $7\times10^{20}$ protons on target of MicroBooNE Data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiometry using synchrotron radiation

It is possible to use synchrotron radiation from electron synchrotrons and electron storage rings as an absolute source, especially in the VUV and soft X-ray regions where other standards are difficult to find. At the NBS, an electron storage ring (SURF-II) has been used to calibrate spectrometers and photometers utilized in solar and aeronomy research and in fusion plasma diagnostics. The radiation incident on these spectrometers can be calculated to uncertainties of 3%, and a technique to exactly determine the number of electrons orbiting in the ring is currently being developed to reduce this uncertainty. Detector calibrations between 5 and 55 nm are routinely performed at SURF-II and transfer standard detectors with 6-10% uncertainties over the range 5-254 nm are supplied.

Saloman, E. B.↗

Transit Detection with a Distributed Network of Telescopes

The discovery since 1995 of more than 80 planets around nearby solar-like stars and the photometric detection of a transit of the planet orbiting HD 209458 (producing a more than 1% drop in brightness that lasts 3 hours) has heralded a new era in astronomy. It has now been demonstrated that small telescopes equipped with sensitive and stable electronic detectors can produce fundamental scientific discoveries regarding the frequency and nature of planets outside the solar system. The modest equipment requirements for the measurement of extrasolar planetary transits are achieved by commercial small aperture telescopes and CCD imagers common among amateur astronomers. With equipment already in hand and armed with target lists, observing techniques and software procedures developed b NASA's Ames Research Center and the University of California at Santa Cruz, non-professional astronomers can contribute significantly to the study of planets around others stars. Statistical analyses of the population of parent stars of the known extrasolar planets indicate that approximately one in ten metal-rich stars should harbor a short-period planet. Given the ten percent chance that a given short-period planet displays transits, we therefore expect that approximately 1% of the most metal rich stars will have a planetary companion detectable by this project. A catalog of 206 highly metal rich nearby F, G and K stars has been compiled, and this catalog will provide a rich source of targets. In addition, main sequence F, G, K and M stars identified to have "transit-like" features in the Hipparcos satellite photometry archive will also be monitored. A commercially available "amateur grade" telescope/CCD/software system acquired late during the 2001 "transit season" for HID 209458 has achieved 0.47% RMS precision for 13 minute time sampling from a suburban backyard under less than ideal observing conditions and a realistic range of airmass values.

Castellano, T.↗

The Discovery of Extrasolar Planets by Backyard Astronomers

The discovery since 1995 of more than 80 planets around nearby solar-like stars and the photometric measurement of a transit of the jovian mass planet orbiting the solar-like star HD 209458 (producing a more than 1% drop in brightness that lasts 3 hours) has heralded a new era in astronomy. It has now been demonstrated that small telescopes equipped with sensitive and stable electronic detectors can produce fundamental scientific discoveries regarding the frequency and nature of planets outside the solar system. The modest equipment requirements for the discovery of extrasolar planetary transits of jovian mass planets in short period orbits around solar-like stars are fulfilled by commercial small aperture telescopes and CCD (charge coupled device) imagers common among amateur astronomers. With equipment already in hand and armed with target lists, observing techniques and software procedures developed by scientists at NASA's Ames Research Center and the University of California at Santa Cruz, non-professional astronomers can contribute significantly to the discovery and study of planets around others stars. In this way, we may resume (after a two century interruption!) the tradition of planet discoveries by amateur astronomers begun with William Herschel's 1787 discovery of the 'solar' planet Uranus.

Castellano, Tim↗

Investigating Gadolinium-Lined Sodium-Iodide Neutron Detectors for Mobile Applications

For enhancing the effectiveness of nonproliferation efforts in neutron detection, most portable instruments rely on 6 Li scintillators, 10 B-based detectors, or gas-filled 3 He proportional counters. Additionally, gamma-ray detectors based on scintillators and semiconductors are often employed for search applications to find radioactive material in the field. These systems typically include dedicated detectors along with separate high voltage supplies and processing electronics for the gamma-ray and neutron detectors. Ideally, a portable radiation detection system should be lightweight, compact, and cost-effective. In the field, scintillators can serve a dual purpose: (1) detecting gamma-rays and (2) detecting neutrons. Gamma-ray detection with scintillators is based on the interaction of gamma-rays within the scintillating material, whereas neutron detection depends indirectly on neutron capture events. These capture events generate conversion electrons and gamma-rays, which can interact with the scintillator. For enhancing neutron capture, the scintillator can be surrounded by neutron absorber materials with a high neutron cross section. The resulting secondary electrons and gamma-rays from neutron interactions, depending on the absorber material used, can then be analyzed to detect the presence of neutron sources. Similarly, semiconductor-based detectors can be employed along with neutron absorbers as liners for neutron detection. 158 Gd has a significantly larger neutron cross section than 3 He, commonly used in gas-filled proportional counters, as shown in Figure 1. For thermal (0.025 eV) neutrons, the absorption cross section of 158 Gd is 10,000 times greater than that of 3 He (refer to Figure 1). This feature makes naturally occurring gadolinium, which consists of 24.8% 158 Gd, a promising neutron absorber material for use in combination with gamma-ray detectors–yielding a hybrid detector–for neutron detection.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Electron and photon reconstruction and identification with the CMS experiment at the CERN LHC

The performance is presented of the reconstruction and identification algorithms for electrons and photons with the CMS experiment at the LHC. The reported results are based on proton-proton collision data collected at a center-of-mass energy of 13 TeV and recorded in 2016–2018, corresponding to an integrated luminosity of 136 fb^-1. Results obtained from lead-lead collision data collected at √(sNN)=5.02 TeV are also presented. Innovative techniques are used to reconstruct the electron and photon signals in the detector and to optimize the energy resolution. Events with electrons and photons in the final state are used to measure the energy resolution and energy scale uncertainty in the recorded events. The measured energy resolution for electrons produced in Z boson decays in proton-proton collision data ranges from 2 to 5%, depending on electron pseudorapidity and energy loss through bremsstrahlung in the detector material. The energy scale in the same range of energies is measured with an uncertainty smaller than 0.1 (0.3)% in the barrel (endcap) region in proton-proton collisions and better than 1 (3)% in the barrel (endcap) region in heavy ion collisions. The timing resolution for electrons from Z boson decays with the full 2016–2018 proton-proton collision data set is measured to be 200 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Concept of an Opto-electronic Accelerometer System (OAS)

An accelerometer based on a spring-suspended reference mass and its precise relative motion measurement by means of 3 two-dimensional position sensitive detectors (PSD) is described. A breadboard model achieves a resolution (longterm linearity) of 25 nm in one direction. Due to the physical principle of the PSD, the second layer is slightly less sensitive than the top layer; accordingly for gravity gradient detection the more sensitive layer is selected for the Z/X component detection. At 10 Hz sampling rate an acceleration gradient of under 10 to the minus 12th power g (i.e., 0.01 E or 0.001 Gal/km) is considered to be detectable.

Kunkel, B.↗

High Resolution X-Ray (HRX) Detector Development

During the performance period of this grant we carried out the following activities: (1) High resolution CCD camera specification and acquisition; (2) Design of CCD camera electronics; (3) Image acquisition hardware and related software development; (4) Design and construction of vacuum-compatible high resolution camera. These activities are described in detail in the report.

Golub, Leon↗