Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wind engineering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Nalu-Wind v.1.2.0

Nalu-Wind is derived from Nalu-CFD (for which Sandia has an existing copyright assertion). Nalu-Wind is specific to the wind energy simulation space. SAND2019-10379 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

Crozier, Paul↗

NYSEG Seneca Compressed Air Energy Storage (CAES) Demonstration Project

Compressed Air Energy Storage (CAES) is a hybrid energy storage and generation concept that has many potential benefits especially in a location with increasing percentages of intermittent wind energy generation. The objectives of the NYSEG Seneca CAES Project included: for Phase 1, development of a Front End Engineering Design for a 130MW to 210 MW utility-owned facility including capital costs; project financials based on the engineering design and forecasts of energy market revenues; design of the salt cavern to be used for air storage; draft environmental permit filings; and draft NYISO interconnection filing; for Phase 2, objectives included plant construction with a target in-service date of mid-2016; and for Phase 3, objectives included commercial demonstration, testing, and two-years of performance reporting. This Final Report is presented now at the end of Phase 1 because NYSEG has concluded that the economics of the project are not favorable for development in the current economic environment in New York State. The proposed site is located in NYSEG’s service territory in the Town of Reading, New York, at the southern end of Seneca Lake, in New York State’s Finger Lakes region. The landowner of the proposed site is Inergy, a company that owns the salt solution mining facility at this property. Inergy would have developed a new air storage cavern facility to be designed for NYSEG specifically for the Seneca CAES project. A large volume, natural gas storage facility owned and operated by Inergy is also located near this site and would have provided a source of high pressure pipeline quality natural gas for use in the CAES plant. The site has an electrical take-away capability of 210 MW via two NYSEG 115 kV circuits located approximately one half mile from the plant site. Cooling tower make-up water would have been supplied from Seneca Lake. NYSEG’s engineering consultant WorleyParsons Group thoroughly evaluated three CAES designs and concluded that any of the designs would perform acceptably. Their general scope of work included development of detailed project construction schedules, capital cost and cash flow estimates for both CAES cycles, and development of detailed operational data, including fuel and compression energy requirements, to support dispatch modeling for the CAES cycles. The Dispatch Modeling Consultant selected for this project was Customized Energy Solutions (CES). Their general scope of work included development of wholesale electric and gas market price forecasts and development of a dispatch model specific to CAES technologies. Parsons Brinkerhoff Energy Storage Services (PBESS) was retained to develop an air storage cavern and well system design for the CAES project. Their general scope of work included development of a cavern design, solution mining plan, and air production well design, cost, and schedule estimates for the project. Detailed Front End Engineering Design (FEED) during Phase 1 of the project determined that CAES plant capital equipment costs were much greater than the $\$$125.6- million originally estimated by EPRI for the project. The initial air storage cavern Design Basis was increased from a single five million cubic foot capacity cavern to three, five million cubic foot caverns with associated air production wells and piping. The result of this change in storage cavern Design Basis increased project capital costs significantly. In addition, the development time required to complete the three cavern system was estimated at approximately six years. This meant that the CAES plant would initially go into service with only one third of the required storage capacity and would not achieve full capability until after approximately five years of commercial operation. The market price forecasting and dispatch modeling completed by CES indicated that the CAES technologies would operate at only 10 to 20% capacity factors and the resulting overall project economics were not favorable for further development. As a result of all of these factors, the Phase 1 FEED developed an installed CAES plant cost estimate of approximately $\$$2,300/KW for the 210MW CAES 1A and 2 cycles. The capital cost for the 136 MW CAES 1 cycle was even higher due to the lower generating capacity of the cycle. Notably, the large equipment could have generated additional capacity (up to 270MW) which would have improved the cost per KW; however, the output was limited by the night time transmission system capability. The research herein, therefore, is particular to the site-specific factors that influenced the design and the current and forecasted generation mix and energy prices in Upstate New York and may not necessarily indicate that CAES plants cannot be economically constructed in other places in New York State or the world.

25 ENERGY STORAGE↗

AGC-3 Irradiation Creep Strain Data Analysis

The Advanced Reactor Technologies Graphite Research and Development Program is conducting an extensive graphite irradiation experiment to provide data for licensing of a high temperature reactor (HTR) design. In past applications, graphite has been used effectively as a structural and moderator material in both research and commercial high temperature gas cooled reactor designs. , Nuclear graphite H 451, used previously in the United States for nuclear reactor graphite components, is no longer available. New nuclear graphite grades have been developed and are considered suitable candidates for new HTR reactor designs. To support the design and licensing of HTR core components within a commercial reactor, a complete irradiated properties database must be developed for these current grades of graphite. Quantitative data on in service material performance are required for the physical, mechanical, and thermal properties of each graphite grade, with a specific emphasis on data accounting for the life limiting effects of irradiation creep on key physical properties of the HTR candidate graphite grades. Further details on the research and development activities and associated rationale required to qualify nuclear grade graphite for use within the HTR are documented in the graphite technology research and development plan.

42 ENGINEERING↗

The AWAKEN wind farm benchmark, Part 2: Modeling results

Accurately modeling wind farm performance in complex atmospheric flows remains a challenge. This paper presents the modeling results of the American WAKE experimeNt (AWAKEN) wind farm benchmark, a collaborative effort involving 16 research groups from academia and industry within the International Energy Agency Wind Technology Collaboration Programme Task 57. The study evaluates a diverse suite of simulation tools, ranging from fast-running engineering wake models to high-fidelity large-eddy simulations, against a diurnal case study observed during the AWAKEN campaign. The benchmark utilized a three-phase structure to progressively assess model performance as observational data availability increased. Initial blind predictions showed that higher-fidelity models did not uniformly outperform simpler simulation tools. A distinct spatial bias was observed where models struggled to resolve the interplay between a low-level jet, wakes, and terrain-induced flow acceleration. In subsequent phases, leveraging additional measurements for model improvement led to a reduction in mean absolute error across the model ensemble; however, this effect was most pronounced in engineering wake models, where targeted calibration reduced error by up to 40~\%. Overall, the study demonstrates that inflow characterization remains a primary prerequisite for accuracy, particularly for models relying on coarse forcing datasets. While the limited ability to resolve local terrain-flow interactions under single-day conditions represent a recognized constraint, the overall findings on wake modeling and real-world validation still provide valuable guidance for model application and for mitigating this limitation.

Bodini, Nicola↗

Energy harvesting to power sensing hardware onboard wind turbine blade

Wind turbines are becoming a larger source of renewable energy in the United States. However, most of the designs are geared toward the weather conditions seen in Europe. Also, in the United States, manufacturers have been increasing the length of the turbine blades, often made of composite materials, to maximize power output. As a result of the more severe loading conditions in the United States and the material level flaws in composite structures, blade failure has been a more common occurrence in the U.S. than in Europe. Therefore, it is imperative that a structural health monitoring system be incorporated into the design of the wind turbines in order to monitor flaws before they lead to a catastrophic failure. Due to the rotation of the turbine and issues related to lightning strikes, the best way to implement a structural health monitoring system would be to use a network of wireless sensor nodes. In order to provide power to these sensor nodes, piezoelectric, thermoelectric and photovoltaic energy harvesting techniques are examined on a cross section of a CX-100 wind turbine blade in order to determine the feasibility of powering individual nodes that would compose the sensor network.

42 ENGINEERING↗

Searching for Grid-Forming Technologies That Do Not Impact Protection Systems: A promising technology

The design of legacy-line protection elements has been guided by the behavior of synchronous machines during faults. Because of the significant field-winding inductance and rotating mass, the magnitude, angular frequency, and phase angle of the back-electromotive force (EMF) voltage waveforms of synchronous machines remain practically constant for several hundreds of milliseconds after a fault occurs. Furthermore this has facilitated the engineering of the memory-polarization technique in mho distance elements, which has been effective for machine-dominant power grids. However, this assumption is no longer held for inverter-based resources (IBRs) because of the lack of field winding and moment of inertia in power electronics devices. Notably, the negative-sequence directional overcurrent protection and the quadrilateral distance elements have been impacted by early IBRs with grid-following (GFL) controls because they did not inject negative-sequence currents during asymmetrical faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy transitions in the early 21st Century

We are in the early stages of a long and complex transition from a global economy based on fossil energy to an economy based on low carbon renewable energy. However, fossil fuel resources are abundant and widely distributed, and they will remain the dominant source of primary energy for at least the next quarter century. In the United States, displacement of coal by natural gas for electric power generation has done more to reduce CO2 emissions than all new renewables combined, and this may occur globally for the next decade or two, even if the European Union does not take advantage of its large unconventional natural gas resources. Greater energy efficiency (not including the efficiencies associated with displacement of coal by gas) will also be more important than new renewables. Cost/benefit ratios are important for sustainability of the transition, and some energy efficiency technologies and displacement of coal by natural gas have lower cost/benefit ratios than wind power, solar power or biofuels. Money spent on the large scale deployment of wind, solar and especially biofuels would be better spent on research, development and demonstration of a broader suite of technologies that would support the energy transition, with a focus on improving the cost benefit ratios of already deployed technologies and developing alternatives. Advanced nuclear reactors, engineered geothermal systems, fossil fuel recovery coupled with CO2 sequestration and pre-combustion or post-combustion decarbonation of fossil fuels with geological CO2 sequestration are among the technologies that might be more cost effective than wind, solar or biofuels, and biofuels have serious adverse societal and environment consequences.

58 GEOSCIENCES↗

Convection heat loss from cavity receiver in parabolic dish solar thermal power system: A review

The convection heat loss from cavity receiver in parabolic dish solar thermal power system can significantly reduce the efficiency and consequently the cost effectiveness of the system. It is important to assess this heat loss and subsequently improve the thermal performance of the receiver. This paper aims to present a comprehensive review and systematic summarization of the state of the art in the research and progress in this area. The efforts include the convection heat loss mechanism, experimental and numerical investigations on the cavity receivers with varied shapes that have been considered up to date, and the Nusselt number correlations developed for convection heat loss prediction as well as the wind effect. One of the most important features of this paper is that it has covered numerous cavity literatures encountered in various other engineering systems, such as those in electronic cooling devices and buildings. The studies related to those applications may provide valuable information for the solar receiver design, which may otherwise be ignored by a solar system designer. Finally, future development directions and the issues that need to be further investigated are also suggested. It is believed that this comprehensive review will be beneficial to the design, simulation, performance assessment and applications of the solar parabolic dish cavity receivers. (author)

14 SOLAR ENERGY↗

Michigan: Michigan's Clean Energy Resources and Economy [Brochure]

By harnessing its abundant supply of conventional hydroelectric power, biomass, and wind, Michigan is well on its way to meeting its goal, set by the 2008 Clean Renewable and Efficient Energy Act, of generating 10% of retail electricity from renewable sources by 2015. Renewable biomass accounted for 39% of renewable energy credits certified in Michigan between 2009 and 2011, thanks in part to Michigan’s 19 million acres of forest land. Small hydroelectric plants, landfill gas, and municipal solid waste are all important sources of renewable electricity in Michigan—together accounting for 34% of renewable energy credits during the same time period. Michigan also has significant undeveloped wind energy potential. Michigan also requires electric providers to develop and fund “energy optimization” programs aimed at reducing electricity consumption. Michigan is one of the few states to count efficiency as an eligible clean energy resource, awarding “energy optimization credits” for successfully reducing energy consumption. Energy optimization credits can be substituted for renewable energy credits. As of December 2009, all utility customers in Michigan are eligible to participate in at least one energy-efficiency program offered through a local utility, and aggregate statewide funding for energy optimization programs has more than tripled from $\$$67 million in 2009 to $\$$208 million in 2011. Michigan is becoming a center for the domestic advanced battery industry. Companies all along the battery supply chain cluster in the state and draw from a talented pool of scientists, engineers, and other skilled workers with decades of experience in the auto industry. Michigan’s geographic position makes the state an attractive site for wind industry manufacturing; 2010 counted 31 wind technology manufacturing facilities in the state.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predicting Instability and the Effect of Wind Loading on Single-Axis Trackers

As PV modules continue to trend toward larger, thinner, and more flexible forms they grow more susceptible to damage from dynamic wind loading. As a result, understanding the impact of wind on PV systems, particularly when mounted on solar-tracking hardware, and identifying robust, stable array layouts and stow strategies is becoming increasingly important for the PV community. In our ongoing DuraMAT project, we are developing an open-source software package, PVade (PV aerodynamic design engineering), to simulate the cascading fluid-structure interaction that occurs within solar-tracking arrays to enable researchers to test hardware, layout, and tracker control changes, leading to enhanced stability and a reduction in wind-driven damage. We will give an overview of the PVade software, highlighting recent user-interface and algorithm developments, before presenting the latest outcomes from our ongoing validation campaign in which we analyze and compare with experimental data obtained from a DuraMAT 1 project. From there, we will present simulated results from a larger, multi-row array and highlight relationships between varying tracker angles and stability as measured by different experimentally validated metrics.

fluid structure interaction↗

Simulating Wind-Driven Loading on PV Systems

As PV modules continue to trend toward larger, thinner, and more flexible forms they grow more susceptible to damage from dynamic wind loading. As a result, understanding the impact of wind on PV systems, particularly when mounted on compliant solar-tracking hardware, and identifying robust, stable array layouts and stow strategies is becoming increasingly important for the PV community. We are developing an open-source software package, PVade (PV aerodynamic design engineering), to simulate the cascading fluid-structure interaction that occurs within single-axis, solar-tracking arrays to enable researchers to test hardware, layout, and tracker control changes, leading to enhanced stability and a reduction in wind-driven damage. We will give an overview of the PVade software and present the latest outcomes from our ongoing validation campaign in which we compare time series and statistical structural responses with field data. From there, we will present simulated results from a larger, multi-row array and highlight the effect of varying tracker angles on stability and the differences between positive and negative tilt angles.

fluid↗

A three-dimensional model of terrain-induced updrafts for movement ecology studies

Abstract Background Spatially explicit simulation models of animal movements through the atmosphere necessarily require a representation of the spatial and temporal variation of atmospheric conditions. In particular, for movements of soaring birds that rely extensively on vertical updrafts to avoid flapping flight, accurate and reliable estimation of the vertical component of wind is critical. The interaction between wind and complex terrain shapes both the horizontal and vertical wind fields, highlighting the need to model the coupling between local terrain features and atmospheric conditions at scales relevant to animal movement. Methods In this work, we propose a new empirical model for estimating the orographic updraft field. The model is developed using computational fluid dynamics simulations of canonical atmospheric conditions over moderately complex terrain. To isolate buoyancy and thermal effects, and focus on terrain-induced effects, we use only simulations of a neutrally stratified atmosphere to develop the model. The model, which we name Engineering Vertical Velocity Estimator (EVVE), is simple to implement and is a function of the underlying terrain elevation map, the desired height above ground level (AGL), and wind conditions at a reference height (80 m). We validate the model with data from the Alaiz mountain (Spain) field campaign. Results Compared to observations, the proposed improved model estimates the updrafts at 120 m AGL with a mean error of 0.11 m/s ( $$\sigma =0.28$$ σ = 0.28 m/s), compared to 0.85 m/s ( $$\sigma =0.58$$ σ = 0.58 m/s) for its baseline. For typical land-based wind turbine hub heights of 80 m AGL, the proposed model has a mean error of 0.04 m/s ( $$\sigma =0.25$$ σ = 0.25 m/s), compared to baseline 0.54 m/s ( $$\sigma =0.45$$ σ = 0.45 m/s) estimations. We illustrate an application of the model in movement ecology by comparing simulated tracks and presence maps of golden eagles ( Aquila chrysaetos ) moving across two distinct landscapes. The tracks and presence maps are obtained using a simple heuristic-based movement model, with the updraft field given by the proposed model and a wind vector-based estimation approach that is currently in wide use in movement ecology studies of raptors and other soaring birds. Conclusions We highlight that movement model results can be sensitive to the underlying orographic updraft model, especially in studies of fine-scale movements in regions of complex topography. We suggest adopting the proposed model rather than the wind vector estimation method for studies of soaring bird movements.

17 WIND ENERGY↗