Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “utility rate analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Steam Generator Model Design Parameter Sensitivity Study Using Advanced Optimization Tools

This study focuses on design parameter sensitivity studies pertaining to a steam generator (SG) model, using both Python and machine-learning tools. The SG model is a mathematical representation (including fluid flow and heat transfer equations/models/correlations) of a steam-generating unit in a pressurized water reactor (PWR)-type small modular reactor (SMR) system. Design studies involve changing the model’s input design parameters (e.g., temperature, pressure, mass flow rate) to observe the resulting effects on the output of the system (e.g., heat transfer coefficient [HTC], Nusselt number, heat transfer performance). Sensitivity studies analyze the degree to which system output and/or desired parameters (e.g., HTC or heat transfer performance) are sensitive to changes in input parameters. By using machine-learning tools such as the Risk Analysis Virtual Environment (RAVEN) developed at Idaho National Laboratory (INL), detailed design parametric sensitivity studies and model optimization were performed. Six input parameters—namely, the pressure, temperature, and mass flow rate for the inlet of the primary-side (hot fluid) and secondary-side (cold fluid) of the SG—were randomly perturbed via RAVEN’s Monte Carlo Sampler module, using uniform distributions (±1% relative changes). The analysis results give valuable insights into SG system performance and optimization, and provide justification for researching optimized sensor placement to effectively monitor and obtain experimental data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Catalyst and reactor design considerations for selective production of acids by oxidative cleavage of alkenes and unsaturated fatty acids with H 2 O 2

Oxidative cleavage of alkenes and unsaturated fatty acids with hydrogen peroxide gives an efficient and sustainable process to obtain mono- and di-acids for polymers and lubricants with fewer safety risks and less environmental impact than processes that utilize ozone or other inorganic oxidizers (e.g., permanganate, dichromate, etc.). Guided by insight into the mechanisms for competing reaction pathways (i.e., epoxidation of alkene on W–(η 2 -O 2 ) complexes vs. H 2 O 2 decomposition) and the apparent kinetics derived from kinetic experiments, here, we postulate that W-based heterogeneous catalysts can provide high performance and stable operations at low H 2 O 2 concentrations. Semi-batch reactors with continuous introduction of H 2 O 2 solutions offer the means to maintain low H 2 O 2 concentrations while providing sufficient quantities of H 2 O 2 to satisfy the reaction stoichiometry. We derived simple kinetic model equations for the epoxidation, ring-opening, oxidative cleavage, and oxidation steps and fit theses equations to batch experimental data to obtain kinetic parameters. Furthermore, this kinetic model describes the concentration profiles of reactant, oxidant, and products well as shown by agreement with experimental data. Further predictions of the optimal H 2 O 2 feed rate for semi-batch operation utilized by the proposed rate expressions and the reactor design equations suggest that low H 2 O 2 feed rate increases selectivity towards oxidative cleavage products and selective use of H 2 O 2 for oxidative cleavage pathway. Comparisons of oxidative cleavage of 4-octene in batch and semi-batch reactors show that semibatch reactors with optimized molar feed rates of H 2 O 2 increased oxidative cleavage product selectivities (76% to 99%; with an increase in butyric acid selectivity from 1% to 55%) and H 2 O 2 selectivity (3% to 30%). In addition, semibatch reaction conditions used avoid H 2 O 2 -mediated dissolution of W-atoms from the catalyst. Analysis of these findings suggest that solid oxide catalysts will be effective for continuous oxidative cleavage reactions if deployed within fixed-bed reactors that allow for distributed introduction of reactants and therefore low in situ concentrations of H 2 O 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Developing affordable and efficient heating devices for enhanced live cell imaging in confocal microscopy

Temperature control is crucial for live cell imaging, particularly in studies involving plant responses to high ambient temperatures and thermal stress. This study presents the design, development, and testing of two cost-effective heating devices tailored for confocal microscopy applications: an aluminum heat plate and a wireless mini-heater. The aluminum heat plate, engineered to integrate seamlessly with the standard 160 mm × 110 mm microscope stage, supports temperatures up to 36°C, suitable for studies in the range of non-stressful warm temperatures (e.g., 25-27°C forArabidopsis thaliana) and moderate heat stress (e.g., 30-36°C forA. thaliana). We also developed a wireless mini-heater that offers rapid, precise heating directly at the sample slide, with a temperature increase rate over 30 times faster than the heat plate. The wireless heater effectively maintained target temperatures up to 50°C, ideal for investigating severe heat stress and heat shock responses in plants. Both devices performed well in controlled studies, including the real-time analysis of heat shock protein accumulation and stress granule formation inA. thaliana. Our designs are effective and affordable, with total construction costs lower than $300. This accessibility makes them particularly valuable for small laboratories with limited funding. Future improvements could include enhanced heat uniformity, humidity control to mitigate evaporation, and more robust thermal management to minimize focus drift during extended imaging sessions. These modifications would further solidify the utility of our heating devices in live cell imaging, offering researchers reliable, budget-friendly tools for exploring plant thermal biology.

Plant Sciences↗

A cloud physics radiometer

The paper describes the design features and capabilities of a seven-channel cloud physics radiometer (CPR) for remote sensing of cloud properties. The CPR channel characteristics and functions are tabulated and diagrammed. Each of the first three channels utilizes a photo-multipler detector, with the high-voltage power supply integrated with the tube into a single unit. In operation a heater is used to keep the optics temperature at or above 273 K and this temperature is constantly monitored. The last four channel detectors and filters are all cooled to the temperature of liquid nitrogen. The inclined scanning mirror rotates at a rate of 3.48 rps. Registration pulses are triggered and recorded as the mirror enters and leaves the + or -45 deg earth observation region. The ice-cloud, water cloud, snow discriminator detector has worked quite well in general. Interesting radiometer data have been obtained and their analysis is under way. The combination of the CPR and the Cloud Lidar System will make possible sophisticated remote sensing cloud studies.

Kyle, H. L.↗

Acquisition and tracking performance measurements for a high speed area array detector system

A proof-of-concept (POC) demonstration system has been developed which demonstrates acquisition, tracking and point-ahead angle sensing for a space optical communications terminal utilizing a single high speed area array detector. The detector is the 128 x 128 pixel Kodak HS-40 photodiode array. It has 64 parallel readout channels and can operate at frames rates up to 40,000 frames/sec with rms readout noise of 20 photoelectrons. A windowing scheme and special purpose digital signal processing electronics are employed to implement acquisition and tracking algorithms. The system operates at greater than 1 kHz sample (frame) rates. Acquisition can be performed in as little as 30 milliseconds with less than 1 picowatt of 0.85 micron beacon power on the detector. At the same power level, the rms tracking accuracy is approximately 1/16 pixel. Results of system analysis and measurements using the POC system are presented.

Short, R. C.↗

Modernization of the Radiation Measurements Laboratory at the Advanced Test Reactor Complex

The Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) is a unique, water-cooled, high-flux test reactor capable of performing tests prototypical of PWR operating conditions. The Radiation Measurements Laboratory (RML) was founded in the 1960s to support reactor operations and to conduct independent scientific research. For nearly six decades RML has performed four primary functions: monitoring of radioactivity by gamma-ray spectroscopy of routine reactor samples, fluence rate determinations for irradiation cycles, fission-rate measurements for the ATR-Critical (ATR-C) Facility, and independent research and development of radiation detection systems and applications. Through the decades, RML has seen technological advancements that have been integrated into each of the critical functions of the laboratory. However, many of the measurement and analysis systems employed to this day can be improved by modernization. Recent progress at RML is improving reliability and accuracy of the radiation measurements performed in support of nuclear energy research for the U.S.A. Department of Energy. The control and data collection systems supporting ATR-C have been upgraded. New High-Purity Germanium (HPGe) spectrometers have been procured with liquid nitrogen recycling capabilities to improve up-time and reduce measurement uncertainties. Fluence-rate measurement techniques are also being improved to ensure accuracy, avoid systemic errors, and identify biases. In a parallel effort, new scientific research avenues are being explored which will provide an opportunity to further enhance the utilization of ATR and ensure the sustainability of the RML as nuclear research continues to evolve. The RML is improving the effectiveness of irradiation services provided by ATR while ensuring a sustainable future for nuclear energy research.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Correlation Between Weather Alerts and Grid Component Failures for Grid Alert

Weather events cause most grid failures. Often, we even get notifications on our phones to take cover or be prepared for an imminent event. If electric grid utilities had a similar warning that also included probable scenarios and the equipment involved, they could prepare and minimize the effects. Recent research at Idaho National Laboratory into electric grid risk analysis methods resulted in a tool that allows for the development of the most likely scenarios given failure probabilities of grid components. INL has a project with the U.S. Department of Energy’s Cybersecurity, Energy Security, and Emergency Response (CESER) program to develop a Grid Alert application that receives messages from the existing emergency alert system, filters and determines components possibly affected by the emergency event, calculates probable scenarios uses MASTERRI and then notifies the utility if there is significant risk. Historical failure data of elements that comprise the U.S. electric grid have been compiled by utilities and organizations such as the international regulatory body North American Electric Reliability Corporation (NERC). Nominal failure rates are obtained from this data. To make this tool possible, estimated failure rates are needed for different component types given the alert type, severity, and location. Historic weather-related grid element failures are correlated with historic weather events from Integrated Public Alert & Warning System (IPAWS). These correlated events and failures are used along with Bayesian updates from the historical norms to provide a modified failure rate for grid elements in the alert areas and calculate probable scenarios. This discusses the Grid Alert project plan but focuses on the data gathered and process used in determining failure rates for possible grid failure scenarios.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Luminescent Bimetallic Two-Coordinate Gold(I) Complexes Utilizing Janus Carbenes

A series of bimetallic carbene-metal-amide (cMa) complexes have been prepared with bridging biscarbene ligands to serve as a model for the design of luminescent materials with large oscillator strengths and small energy differences between the singlet and triplet states (ΔE ST ). The complexes have a general structure (R 2 N)Au(:carbene—carbene:)Au(NR 2 ). The bimetallic complexes show solvation-dependent absorption and emission that is analyzed in detail. It is found that the molar absorptivity of the bimetallic complexes is correlated with the energy barrier to rotation of the metal–ligand bond. The bimetallic cMa complexes also exhibit short emission lifetimes (τ = 200–300 ns) with high photoluminescence efficiencies (Φ PL > 95%). The radiative rates of bimetallic cMa complexes are 3–4 times faster than that of the corresponding monometallic complexes. Analysis of temperature-dependent luminescence data indicates that the lifetime for the singlet state (τS 1 ) of bimetallic cMa complexes is near 12 ns with a ΔE ST of 40–50 meV. Here the presented compounds provide a general design for cMa complexes to achieve small values for ΔE ST while retaining high radiative rates. Solution-processed organic light-emitting devices (OLEDs) made using two of the complexes as luminescent dopants show high efficiency and low roll-off at high luminance.

14 SOLAR ENERGY↗

An analysis of the Seasat Satellite Data Distribution System

A computerized data distribution network for remote accessing of Seasat generated data is described. The service is intended as an experiment to determine user needs and operational abilities for utilizing on-line satellite generated oceanographic data. Synoptic weather observations are input to the U.S. Fleet Numerical Oceanographic Central for preparation and transfer to a PDP 11/60 central computer, from which all access trunks originate. The data available includes meteorological and sea-state information in the form of analyses and forecasts, and users are being monitored for reactions to the system design, data products, system operation, and performance evaluation. The system provides data on sea level and upper atmospheric pressure, sea surface temperature, wind magnitude and direction, significant wave heights, direction, and periods, and spectral wave data. Transmissions have a maximum rate of 1.1 kbit/sec over the telephone line.

Ferrari, A. J.↗

Experimental investigation of unsteady flow dynamics in therminol-66 using edge tone-induced oscillations

Recent research has demonstrated that flow oscillations induced by a wedge positioned opposite the jet outlet in edge tones can be effectively utilized for flow measurement purposes. This highlights the necessity for developing advanced instrumentation capable of precise flow measurements in experimental setups exposed to radiation and in challenging fluids such as molten salts. Here, this study contributes to the existing body of knowledge by conducting experiments using Therminol-66, an effective surrogate for FLiBe under appropriate temperature conditions for nuclear applications, across a broad range of Reynolds numbers from 17,700 to 555,000. Experiments were conducted with Therminol-66 at approximately 368.8 K under atmospheric pressure, with varying flow rates. A reliable correlation was established between the generated frequencies, corresponding flow rates, and device geometry parameters. The data were subjected to non-dimensional analysis to reveal the interrelationships among flow rate, fluid properties, device geometry, and their impact on the acoustic tones produced by the edge tone device. These findings contribute to the development of precise flow measurement instrumentation for use in challenging environments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Demonstration of sub-micron UCN position resolution using room-temperature CMOS sensor

High spatial resolution of ultracold neutron (UCN) measurement is of growing interest to UCN experiments such as UCN spectrometers, UCN polarimeters, quantum physics of UCNs, and quantum gravity. Here we utilize physics informed deep learning to enhance the experimental position resolution and to demonstrate sub-micron spatial resolutions for UCN position measurements obtained using a room-temperature CMOS sensor, extending our previous work that demonstrated a position uncertainty of 1.5 microns. We explore the use of the open-source software Allpix Squared to generate experiment-like synthetic hit images with ground-truth position labels. We use physics-informed deep learning by training a fully connected neural network (FCNN) to learn a mapping from input hit images to output hit position. The automated analysis for sub-micron position resolution in UCN detection combined with the fast data rates of current and next generation UCN sources will enable improved precision for future UCN research and applications.

10B nanometer thin film↗

Characterizing Ultrafast Intersystem Crossing Pathways in Molecular Pt Dimers Using Time-Resolved Wide-Angle X-ray Scattering

Vibronic coupling between transition metal charge transfer states is a potential mechanism for enhancing the intersystem crossing (ISC) rate. Vibronic coupling-driven ISC has been observed in Pt­(II) dimer complexes, where the trajectory across excited-state pathways is tuned by atomic displacements via Pt–Pt stretching vibrations. Time-resolved wide-angle X-ray scattering (TR-WAXS) was utilized to quantify the Pt–Pt contraction following metal–metal-to-ligand charge transfer (MMLCT) excitation in Pt dimers with different bridging ligands. Both complexes exhibit Pt–Pt bond formation with a decrease in Pt–Pt distance of ∼ 0.25 Å and coherent vibrational wavepackets (CVWPs) encoded in the Pt–Pt contraction of both dimers. However, the complexes exhibit different time-dependent evolution of their CVWPs. Analysis of interference patterns between different CVWPs is used to track the trajectory across the excited-state surfaces. Furthermore, this work demonstrates that the interference between CVWPs in ultrafast TR-WAXS encodes indirect information regarding electronic excited-states to reveal the Pt dimer bridge-dependent ISC mechanism.

Computational chemistry↗

Characterizing the effect of incrementally increasing dry bulb temperature on linear and nonlinear measures of heart rate variability in nonpregnant, mid-gestation, and late-gestation sows

Abstract Characterizing the sow physiological response to an increased heat load is essential for effective heat stress mitigation. The study objective was to characterize the effects of a 400-min heating episode on sow heart rate variability (HRV) at different reproductive stages. HRV is a commonly used noninvasive proxy measure of autonomic function. Twenty-seven sows were enrolled in the study according to their gestation stage at time of selection: 1) nonpregnant (NP; n = 7), 2) mid-gestation (MID; 57.3 ± 11.8 d gestation; n = 11), and 3) late-gestation (LATE; 98.8 ± 4.9 d gestation; n = 8). The HRV data utilized in the study were collected from each pig as the dry bulb temperature in the room increased incrementally from 19.84 ± 2.15 °C to 35.54 ± 0.43 °C (range: 17.1–37.5 °C) over a 400-min period. After data collection, one 5-min set of continuous heart rate data were identified per pig for each of nine temperature intervals (19–20.99, 21–22.99, 23–24.99, 25–26.99, 27–28.99, 29–30.99, 31–32.99, 33–34.99, and 35–36.99 °C). Mean inter-beat interval length (RR), standard deviation of r-r intervals (SDNN), root mean square of successive differences (RMSSD), high frequency spectral power (HF), sample entropy (SampEn), short-term detrended fluctuation analysis (DFAα1), and three measures (%REC, DET, LMEAN) derived from recurrence quantification analysis were calculated for each data set. All data were analyzed using the PROC GLIMMIX procedure in SAS 9.4. Overall, LATE sows exhibited lower RR than NP sows (P < 0.01). The standard deviation of r–r intervals and RMSSD differed between each group (P < 0.01), with LATE sows exhibiting the lowest SDNN and RMSSD and NP sows exhibiting the greatest SDNN and RMSSD. Late-gestation sows exhibited lower HF than both MID and NP sows (P < 0.0001), greater DFA values than NP sows (P = 0.05), and greater DET compared to MID sows (P = 0.001). Late-gestation also sows exhibited greater %REC and LMEAN compared to MID (P < 0.01) and NP sows (all P < 0.01). In conclusion, LATE sows exhibited indicators of greater autonomic stress throughout the heating period compared to MID and NP sows. However, temperature by treatment interactions were not detected as dry bulb increased. Future studies are needed to fully elucidate the effect of gestational stage and increasing dry bulb temperature on sow HRV.

Agriculture↗

Hanford Site Composite Analysis Special Analysis: P2R Model Predictive Contaminant Transport Simulations - Sensitivity Case

This environmental calculation file (ECF) documents the methodologies, assumptions, and results of predictive fate and transport simulations using the Plateau-to-River (P2R) model. This ECF supports the reevaluation of the representativeness of solid-waste radionuclide inventory and release rate from three solid waste sites included in the recently completed Hanford Site Composite Analysis (CA) (DOE-RL-2019-52, Composite Analysis for Low-Level Waste Disposal in the Hanford Site Central Plateau (FY 2020)). Specifically, this ECF supports the reevaluation of the representativeness of the base case inventory and radionuclide waste release rates from three solid waste sites (i.e., 218-E-12B, 218-W-3A and 218-W-3AE) and two radionuclides (carbon-14 [C-14] and technetium [Tc-99]). These three waste sites and two radionuclides were identified as being the most significant contributors to groundwater contamination and dose in the CA at time periods after the compliance period. The release rates and footprints of the releases from the vadose zone are implemented in the fate and transport modeling utilizing the HSS package.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Accurate and Fast Anomaly Detection in Additive Composite-Based Manufacturing using Thermal Cameras

Today, large-scale additive manufacturing with plastics and composite materials requires continuous monitoring by experienced staff to prevent, detect and correct anomalous events affecting the performance of the printed part. We address the complexity of this demanding task by designing a camera-based anomaly detection system utilizing probabilistic principal component analysis (PPCA). This is a machine learning technique is trained with thermal images collected during normal operation of the large-scale printer (Cincinnati BAAM). This technique is advantageous for practical applications as there is no need to artificially introduce anomalous conditions into model training. During deployment, we challenge this model by introducing deliberate variations of the extruder speed. We reduce extrusion speed to a lower level, between 70 and 95% of the nominal value to collected test images. Our results show that images are easily identified as anomalous for extruder speeds at or below 85% of the nominal speed, meaning that an anomalous reduction of the material deposition rate can be detected within seconds of its onset. We show that our results are robust to (a) camera-to-camera variability and (b) print-to-print variability.

Pike, John [ORNL]↗

Low temperature simulation of subliming boundary layer flow in Jupiter atmosphere

A low-temperature approximate simulation for the sublimation of a graphite heat shield under Jovian entry conditions is studied. A set of algebraic equations is derived to approximate the governing equation and boundary conditions, based on order-of-magnitude analysis. Characteristic quantities such as the wall temperature and the subliming velocity are predicted. Similarity parameters that are needed to simulate the most dominant phenomena of the Jovian entry flow are also given. An approximate simulation of the sublimation of the graphite heat shield is performed with an air-dry-ice model. The simulation with the air-dry-ice model may be carried out experimentally at a lower temperature of 3000 to 6000 K instead of the entry temperature of 14,000 K. The rate of graphite sublimation predicted by the present algebraic approximation agrees to the order of magnitude with extrapolated data. The limitations of the simulation method and its utility are discussed.

Chen, C. J.↗

An Analytical Tool for Fracture Control

The structural integrity of critical NASA space flight hardware is ensured through a damage tolerance program which is dictated in the fracture control requirements. The goal of a fracture control program is to ensure proper material selection and control, control of working stress levels, use of fracture resistant design concepts, manufacturing process control, and the use of qualified inspection procedures. The damage tolerance philosophy assumes that all components contain initial defects and the damage accumulation process is thus entirely crack propagation. The service capability of fracture critical components is determined by analysis and/or test. A large percentage of NASA fracture critical hardware is certified by analysis only and it is therefore imperative that the analysis code utilized contain the latest state of the art technology. Not all space contractors and vendors are able to develop and maintain an analysis code which meets this requirement. A response to this need has been fulfilled by the development of the NASA/FLAGRO (NASGRO) fracture mechanics code here at the Johnson Space Center. The NASGRO code is based primarily in Linear Elastic Fracture Mechanics (LEFM) and is continually updated to meet to needs of the user community. Development assistance comes from other NASA centers as well as the European Space Agency (ESA). The code currently has a vast materials data file (over 350 different entries) which defines the material strength, fracture toughness, crack growth rate, and crack growth threshold. The code also allows for user defined inputs of data from other sources. The code also provides a large library of stress intensity factor solutions for numerous geometries and loading conditions.

Patin, Raymond M.↗

Observations of Small Debris from the Cosmos 1408 Anti-Satellite Test using the HUSIR and Goldstone Radars

On 15 November 2021, Russia conducted a direct-ascent anti-satellite (ASAT) test against its Cosmos 1408 satellite, which had been in orbit since 1982. The test produced at least 1500 fragments trackable by the U.S. Space Surveillance Network (SSN). The test is a significant event because the resulting cloud has the potential to endanger the International Space Station and other satellites in low Earth orbit (LEO). For almost 30 years, the NASA Orbital Debris Program Office (ODPO) has used the Haystack Ultrawideband Satellite Imaging Radar (HUSIR), operated by the Massachusetts Institute of Technology’s Lincoln Laboratory to perform statistical measurements of debris in LEO too small to be tracked by the SSN, nominally down to 5.5 mm at 1000 km altitude. The ODPO also utilizes the Goldstone Orbital Debris Radar (Goldstone), operated by NASA’s Jet Propulsion Laboratory, to characterize the small debris environment in LEO down to approximately 3 mm at 1000 km altitude. To characterize the small debris component of the Cosmos 1408 ASAT test, a series of observation campaigns were conducted with the HUSIR and Goldstone radars. This paper discusses the observation planning, including beam overlap analysis needed for Goldstone bistatic operation, using a model of the debris cloud produced with the NASA Standard Satellite Breakup Model. A description of the radars and the data processing techniques used to analyze the data are also discussed. Finally, results of the measurement campaigns including cumulative count rate versus size and surface area flux versus altitude and inclination are presented

James Murray↗