Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “undulators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

The PETRA III extension

The 3{sup rd} generation low-emittance 6 GeV PETRA III facility has been substantially modified to add new beamlines. This extension project involved the complete removal and reconstruction of part of the storage ring with a double-bend achromat lattice as well as the construction of two new experimental halls. Making use of two long straight sections and a canted undulator scheme in the rebuilt arcs, up to ten new insertion device beamlines can be accommodated. In the current phase of the project, seven insertion device and one bending magnet beamline are being implemented.

43 PARTICLE ACCELERATORS↗

Photon beamline frontends for the PETRA III extension project

The photon beamline frontend design for the new insertion device (ID) beamlines of the PETRA III extension project will be presented. The design is based on the concepts developed for the photon beamline frontends at PETRA III. This generic design approach minimized the number of specialized components for all beamlines. The girder concept with kinematic mounts at each girder allowed a fast and reliable installation phase. The extension beamlines are located in two new additional buildings. There will be 4 sectors with two undulator IDs in each sector with a canting angle of 20 mrad between the insertion devices. Additionally, two straight sections and a bending magnet chamber will be modified: one straight section will be transformed to a side station sector, the straight section with the 40 m long damping wiggler will be used as a hard X-ray source, and the bending magnet will serve as a soft-X-ray source.

43 PARTICLE ACCELERATORS↗

Micro- and nano-imaging at the diamond beamline I13L-imaging and coherence

The Diamond Beamline I13L is dedicated to imaging on the micron- and nano-lengthscale, operating in the energy range between 6 and 30 keV. For this purpose two independent stations have been built. The imaging branch is fully operational for micro-tomography and in-line phase contrast imaging with micrometer resolution. Currently a full-field microscope providing 50nm spatial resolution over a field of view of 100 µm is being tested. On the coherence branch, coherent diffraction imaging techniques such as ptychography and coherent X-ray Bragg diffraction are currently developed. The beamline contains a number of unique features. The machine layout has been modified to the so-called mini-beta scheme, providing significantly increased flux from the two canted undulators. New instrumental designs such as a robot arm for the detector in diffraction experiments have been employed. The imaging branch is operated in collaboration with Manchester University, called therefore the Diamond-Manchester Branchline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Construction and performance of combustion beamline at NSRL

An undulator-based VUV beamline BL03U is constructed at the National Synchrotron Radiation Laboratory. Optical design and performance test results are presented in this paper. The monochromator is a Czerny–Turner configuration with a toroidal collimating mirror, two plane gratings, and a toroidal focusing mirror. Plane gratings with line densities of 200 and 400 l/mm are used to cover the photon energy range of 5–21 eV. A gas absorption spectrum is used to evaluate the beamline performance. The photon energy resolving power (E/ΔE) of the beamline is approximately 3900 at 7.3 eV for the 200 l/mm grating and 4200 at 14.6 eV for the 400 l/mm grating. The photon flux is approximately 5×10{sup 12} photons/s/300 mA at energy of 10 eV.

43 PARTICLE ACCELERATORS↗

Low energy soft x-ray emission spectrometer at BL-09A in NewSUBARU

A compact soft X-ray emission spectrometer for the energy region of 50-600 eV has been designed and constructed for the long undulator beamline BL-09A in the NewSUBARU synchrotron radiation (SR) facility. The optical design of the spectrometer is based on a grazing incidence flat-field spectrometer using a valid line-spacing grating. The average groove density of the grating is 2000 L/mm, and the angle of incidence to the grating is 86.5 deg. The distances from the slit to the grating and from the grating to the CCD are 355 mm and 650 mm, respectively. The energy resolution, E/ΔE, was estimated to be greater than 1000 in the energy range of 50-600 eV. Spectra of K-emission X-rays of several light elements, such as B, C, N, and O, from various samples were successfully obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft x-ray spectromicroscopy using compact scanning transmission x-ray microscope at the photon factory

We report the stability and recent performances of a new type of scanning transmission X-ray microscopy. The optics and compact design of the microscope realized mobility and robust performance. Detailed consideration to the vibration control will be described. The insertion device upgraded to elliptical polarization undulator enabled linear dichroism and circular dichroism experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Newly designed double surface bimorph mirror for BL-15A of the photon factory

BL-15A is a new x-ray undulator beamline at the Photon Factory. It will be dedicated to two independent research activities, simultaneous XAFS/XRF/XRD experiments, and SAXS/WAXS/GI-SAXS studies. In order to supply a choice of micro-focus, low-divergence and collimated beams, a double surface bimorph mirror was recently developed. To achieve further mirror surface optimization, the pencil beam scanning method was applied for “in-situ” beam inspection and the Inverse Matrix method was used for determination of optimal voltages on the piezoelectric actuators. The corrected beam profiles at every focal spot gave good agreement with the theoretical values and the resultant beam performance is promising for both techniques. Quick and stable switching between highly focused and intense collimated beams was established using this new mirror with the simple motorized stages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-heat-load monochromator options for the RIXS beamline at the APS with the MBA lattice

With the MBA lattice for APS-Upgrade, tuning curves of 2.6 cm period undulators meet the source requirements for the RIXS beamline. The high-heat-load monochromator (HHLM) is the first optical white beam component. There are four options for the HHLM such as diamond monochromators with refrigerant of either water or liquid nitrogen (LN{sub 2}), and silicon monochromators of either direct or indirect cooling system. Their performances are evaluated at energy 11.215 keV (Ir L-III edge). The cryo-cooled diamond monochromator has similar performance as the water-cooled diamond monochromator because GaIn of the Cu-GaIn-diamond interface becomes solid. The cryo-cooled silicon monochromators perform better, not only in terms of surface slope error due to thermal deformation, but also in terms of thermal capacity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New x-ray pink-beam profile monitor system for the SPring-8 beamline front-end

A new beam profile monitoring system for the small X-ray beam exiting from the SPring-8 front-end was developed and tested at BL13XU. This system is intended as a screen monitor and also as a position monitor even at beam currents of 100 mA by using photoluminescence of a chemical vapor deposition-grown diamond film. To cope with the challenge that the spatial distribution of the photoluminescence in the vertical direction is too flat to detect the beam centroid within a limited narrow aperture, a filter was installed that absorbs the fundamental harmonic concentrated in the beam center, which resulted in “de-flattening” of the vertical distribution. For the measurement, the filter crossed the photon beam vertically at high speed to withstand the intense heat flux of the undulator pink-beam. A transient thermal analysis, which can simulate the movement of the irradiation position with time, was conducted to determine the appropriate configuration and the required moving speed of the filter to avoid accidental melting. In a demonstration experiment, the vertically separated beam profile could be successfully observed for a 0.8 × 0.8 mm{sup 2} beam shaped by an XY slit and with a fundamental energy of 18.48 keV. The vertical beam centroid could be detected with a resolution of less than 0.1 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simultaneous 8.2 keV phase-contrast imaging and 24.6 keV X-ray diffraction from shock-compressed matter at the LCLS

In this paper, we demonstrate simultaneous phase-contrast imaging (PCI) and X-ray diffraction from shock compressed matter at the Matter in Extreme Conditions endstation, at the Linac Coherent Light Source (LCLS). We utilize the chromaticity from compound refractive X-ray lenses to focus the 24.6 keV 3rd order undulator harmonic of the LCLS to a spot size of 5 μm on target to perform X-ray diffraction. Simultaneous PCI from the 8.2 keV fundamental X-ray beam is used to visualize and measure the transient properties of the shock wave over a 500 μm field of view. Furthermore, we demonstrate the ability to extend the reciprocal space measurements by 5 Å –1 , relative to the fundamental X-ray energy, by utilizing X-ray diffraction from the 3rd harmonic of the LCLS.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lasing Below 170 nm Using an Oscillator FEL

The short wavelength operation of free-electron laser (FEL) oscillators is limited by the availability of high-reflectivity, thermally stable, and radiation-resistant FEL mirrors in the VUV wavelength. We report our recent work to extend the shortest lasing wavelength of the oscillator FEL to 168.6 nm using a storage ring FEL. This progress has been made possible by developing a new FEL configuration with substantially reduced undulator harmonic radiation on the FEL mirror, a thermally stable FEL optical cavity, and a new type of high-reflectivity fluoride-based multilayer coating with a protective capping layer. Using these fluoride-based mirrors, we have demonstrated storage ring FEL lasing from 168.6 to 179.7 nm with excellent beam stability. Employing this VUV FEL in Compton scattering, we have produced the first 120 MeV gamma rays at the High Intensity Gamma-ray Source (HIGS). Furthermore, operating the HIGS in this new high-energy region will create many new opportunities for photonuclear physics research, in particular, the low-energy QCD research.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Shaded fraction and backtracking in single-axis trackers on rolling terrain

A generalized closed-form equation for the shaded collector fraction in solar arrays on rolling or undulating terrain is provided for single-axis tracking and fixed-tilt systems. The equation accounts for different rotation angles between the shaded and shading trackers, cross-axis slope between the two trackers, and offset between the collector plane and axis of rotation. The validity of the equation is demonstrated through comparison with numerical ray-tracing simulations and remaining minor sources of error are quantified. Additionally, a simple procedure to determine backtracking rotations for each row in an array installed on the rolling terrain (varying in the direction perpendicular to the tracker axes) is provided. The backtracking equation accounts for a desired shaded fraction (including complete shade avoidance) as well as an axis-collector offset. Test cases are provided to facilitate implementation of these equations.

14 SOLAR ENERGY↗

“Beam à la carte”: Laser heater shaping for attosecond pulses in a multiplexed x-ray free-electron laser

Electron beam shaping allows the control of the temporal properties of x-ray free-electron laser pulses from femtosecond to attosecond timescales. Here, we demonstrate the use of a laser heater to shape electron bunches and enable the generation of attosecond x-ray pulses. We demonstrate that this method can be applied in a selective way, shaping a targeted subset of bunches while leaving the remaining bunches unchanged. This experiment enables the delivery of shaped x-ray pulses to multiple undulator beamlines, with pulse properties tailored to specialized scientific applications.

43 PARTICLE ACCELERATORS↗

Electrostatic shape control of a charged molecular membrane from ribbon to scroll

Bilayers of amphiphiles can organize into spherical vesicles, nanotubes, planar, undulating, and helical nanoribbons, and scroll-like cochleates. These bilayer-related architectures interconvert under suitable conditions. Here, a charged, chiral amphiphile (palmitoyl-lysine, C 16 -K 1 ) is used to elucidate the pathway for planar nanoribbon to cochleate transition induced by salt (NaCl) concentration. In situ small- and wide-angle X-ray scattering (SAXS/WAXS), atomic force and cryogenic transmission electron microscopies (AFM and cryo-TEM) tracked these transformations over angstrom to micrometer length scales. AFM reveals that the large length (L) to width (W) ratio nanoribbons (L/W > 10) convert to sheets (L/W → 1) before rolling into cochleates. Furthermore, a theoretical model based on electrostatic and surface energies shows that the nanoribbons convert to sheets via a first-order transition, at a critical Debye length, with 2 shallow minima of the order of thermal energy at L/W >> 1 and at L/W = 1. SAXS shows that interbilayer spacing ( D ) in the cochleates scales linearly with the Debye length, and ranges from 13 to 35 nm for NaCl concentrations from 100 to 5 mM. Theoretical arguments that include electrostatic and elastic energies explain the membrane rolling and the bilayer separation–Debye length relationship. These models suggest that the salt-induced ribbon to cochleate transition should be common to all charged bilayers possessing an intrinsic curvature, which in the present case originates from molecular chirality. Our studies show how electrostatic interactions can be tuned to attain and control cochleate structures, which have potential for encapsulating, and releasing macromolecules in a size-selective manner.

36 MATERIALS SCIENCE↗

Cryo-EM structures of light-harvesting 2 complexes from Rhodopseudomonas palustris reveal the molecular origin of absorption tuning

The genomes of some purple photosynthetic bacteria contain a multigene puc family encoding a series of α- and β-polypeptides that together form a heterogeneous antenna of light-harvesting 2 (LH2) complexes. To unravel this complexity, we generated four sets of puc deletion mutants in Rhodopseudomonas palustris , each encoding a single type of pucBA gene pair and enabling the purification of complexes designated as PucA-LH2, PucB-LH2, PucD-LH2, and PucE-LH2. The structures of all four purified LH2 complexes were determined by cryogenic electron microscopy (cryo-EM) at resolutions ranging from 2.7 to 3.6 Å. Uniquely, each of these complexes contains a hitherto unknown polypeptide, γ, that forms an extended undulating ribbon that lies in the plane of the membrane and that encloses six of the nine LH2 αβ-subunits. The γ-subunit, which is located near to the cytoplasmic side of the complex, breaks the C9 symmetry of the LH2 complex and binds six extra bacteriochlorophylls (BChls) that enhance the 800-nm absorption of each complex. The structures show that all four complexes have two complete rings of BChls, conferring absorption bands centered at 800 and 850 nm on the PucA-LH2, PucB-LH2, and PucE-LH2 complexes, but, unusually, the PucD-LH2 antenna has only a single strong near-infared (NIR) absorption peak at 803 nm. Comparison of the cryo-EM structures of these LH2 complexes reveals altered patterns of hydrogen bonds between LH2 αβ-side chains and the bacteriochlorin rings, further emphasizing the major role that H bonds play in spectral tuning of bacterial antenna complexes.

59 BASIC BIOLOGICAL SCIENCES↗

APS: High-Energy X-rays Expediting Applied and Fundamental Research

The Advanced Photon Source (APS) at Argonne National Laboratory (ANL) was designed and built as one of the first large 3rd generation synchrotrons operated at 7 GeV. The United States Department of Energy (DOE) Office of Science funded the construction and continues to fund the operation of this national facility. Furthermore, the beamlines were originally operated by Collaborative Access Teams (CAT), which allowed a strong involvement of research institutes, universities, and industry. Today 43 of 68 beamlines are operated by the X-ray Science Division (XSD) and 35 beamlines are directly funded by the DOE Office of Science. The APS became operational in 1995, and was planned right from the beginning with 4 beamlines dedicated to high-energy x-rays above 40 keV: 1-ID designed to study engineering materials science, 6-ID-D for magnetism and condensed matter research, 11-ID-B dedicated to magnetic Compton scattering using an Elliptical Multipole Wiggler, and 11-ID-C for materials science and condensed matter physics. These stations were later joined by the bending magnet beamlines 6-BM for white beam studies and 17-BM for rapid powder diffraction. CAT operated beamlines such as 15-ID for crystallography or 16-ID for high-pressure studies also use the high-energy x-ray regime frequently. The program in Compton scattering ended in 2004 and the wiggler was replaced by an undulator. 11-ID-B became the first dedicated station for Pair Distribution Function (PDF) Analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-pressure studies of melamine

We performed the first high-pressure study of melamine using X-ray Raman spectroscopy (XRS) up to -17 GPa in a diamond anvil cell at ambient temperature. We utilized the 16 ID-D undulator beamline at the Advanced Photon Source for the X-ray source. The observed diminishment of the 1s {yields} {pi}* peak as well as other changes in the XRS spectra with pressure suggest the possibility of intra- and inter-molecular bonding changes due to two phase changes in the investigated pressure range or hybridization changes of atomic orbitals in the material with pressure. We also performed a complementary X-ray powder diffraction study of neat melamine up to 24 GPa observing at least two phase transitions with pressure. Pressure cycling indicated that the phase transitions were reversible. Density-functional theory calculations performed on the system at ambient and low pressure show a high level of agreement with the experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗