Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Single photon detection and timing in the Lunar Laser Ranging Experiment.

The goals of the Lunar Laser Ranging Experiment lead to the need for the measurement of a 2.5 sec time interval to an accuracy of a nanosecond or better. The systems analysis which included practical retroreflector arrays, available laser systems, and large telescopes led to the necessity of single photon detection. Operation under all background illumination conditions required auxiliary range gates and extremely narrow spectral and spatial filters in addition to the effective gate provided by the time resolution. Nanosecond timing precision at relatively high detection efficiency was obtained using the RCA C31000F photomultiplier and Ortec 270 constant fraction of pulse-height timing discriminator. The timing accuracy over the 2.5 sec interval was obtained using a digital interval with analog vernier ends. Both precision and accuracy are currently checked internally using a triggerable, nanosecond light pulser. Future measurements using sub-nanosecond laser pulses will be limited by the time resolution of single photon detectors.

Poultney, S. K.↗

Camera memory study for large space telescope

Specifications were developed for a memory system to be used as the storage media for camera detectors on the large space telescope (LST) satellite. Detectors with limited internal storage time such as intensities charge coupled devices and silicon intensified targets are implied. The general characteristics are reported of different approaches to the memory system with comparisons made within the guidelines set forth for the LST application. Priority ordering of comparisons is on the basis of cost, reliability, power, and physical characteristics. Specific rationales are provided for the rejection of unsuitable memory technologies. A recommended technology was selected and used to establish specifications for a breadboard memory. Procurement scheduling is provided for delivery of system breadboards in 1976, prototypes in 1978, and space qualified units in 1980.

Hoffman, C. P.↗

A moderate-resolution, wide-band, astronomical echelle spectrograph

An echelle spectrograph is described which is specifically designed for use on a 52-in. f/7.6 telescope as an instrument optimally suited for studying spectra of the faint optical counterparts to X-ray stars at moderate spectral resolution. The spectrograph is also able to accomodate a two-dimensional photon-tagging panoramic image detector so that high-time-resolution studies of the spectra of variable stars can be carried out. The equations for echelle spectrographs are summarized, and some features of the present instrument are discussed. These include its prism cross-disperser, small elliptical flat mirror, and unusually high efficiency. An iron-argon calibration spectrum obtained by pressing the film against the output fiber optics of a three-stage electrostatically focused image intensifier, a spectrum of P Cygni taken by placing the film directly in the image plane of the spectrograph, and a photon-counted image of a small section of an echellogram produced during an observation of the Ring nebula in Lyra are provided to illustrate the performance of the instrument.

Bardas, D.↗

Aircraft Cargo Compartment Fire Test Simulation Program

The objective of the test was to assess fire containment and fire extinguishment in the cargo by reducing the ventilation through the cargo compartment. Parameters which were measured included ignition time, burnthrough time, and physical damage to the cargo liner, composition of selected combustible gases, temperature-time histories, heat flux, and detector response. The ignitor load was made of a typical cargo consisting of filled cardboard cartons occupying 50% of the compartment volume.

Blumke, R. E.↗

Shuttle orbiter Ku-band radar/communications system design evaluation. Ku band bent-pipe channel performance evaluation

Because of difficulties with the bit detector of the SPA mode 1 channel 3 input port, a new bit synchronizer was required. The two prime candidate designs are described and analyzed. The selected design is a modification of one which utilizes a phase frequency detector to track the received data clock frequency and a mid-bit transition point sample detector to generate a bit timing error (phase error) signal to control the relative phase between the local clock and the local data stream. The model used to calculate the effects of cable attenuation and rise time degradation is discussed.

Holmes, J. K.↗

Sensor failure and multivariable control for airbreathing propulsion systems

A new sensor/actuator failure analysis technique for turbofan jet engines was developed. Three phases of failure analysis, namely detection, isolation, and accommodation are considered. Failure detection and isolation techniques are developed by utilizing the concept of Generalized Likelihood Ratio (GLR) tests. These techniques are applicable to both time varying and time invariant systems. Three GLR detectors are developed for: (1) hard-over sensor failure; (2) hard-over actuator failure; and (3) brief disturbances in the actuators. The probability distribution of the GLR detectors and the detectability of sensor/actuator failures are established. Failure type is determined by the maximum of the GLR detectors. Failure accommodation is accomplished by extending the Multivariable Nyquest Array (MNA) control design techniques to nonsquare system designs. The performance and effectiveness of the failure analysis technique are studied by applying the technique to a turbofan jet engine, namely the Quiet Clean Short Haul Experimental Engine (QCSEE). Single and multiple sensor/actuator failures in the QCSEE are simulated and analyzed and the effects of model degradation are studied.

Behbehani, K.↗

Real-time synthetic aperture radar processing

Real-time acousto-optic SAR processors are described and experimentally demonstrated. SAR imaging is performed in one of the architectures by applying the signal to an acousto-optic device and correlating it with chirp signals recorded on an optical transparency by time integration on a CCD detector. In a different implementation, the imaging is preformed by interfering the light beams diffracted from two separate acousto-optic devices, one modulated the radar signal and the second by the reference chirp waveform.

Psaltis, D.↗

A cooled avalanche photodiode with high photon detection probability

An avalanche photodiode has been operated as a photon-counting detector with 2 to 3 times the sensitivity of currently-available photomultiplier tubes. APD (avalanche photodiodes) detection probabilities that exceed 27% and approach 50% have been measured at an optimum operating temperature which minimizes noise. The sources of noise and their dependence on operating temperature and bias voltage are discussed.

Robinson, D. L.↗

Rapid code acquisition algorithms employing PN matched filters

The performance of four algorithms using pseudonoise matched filters (PNMFs), for direct-sequence spread-spectrum systems, is analyzed. They are: parallel search with fix dwell detector (PL-FDD), parallel search with sequential detector (PL-SD), parallel-serial search with fix dwell detector (PS-FDD), and parallel-serial search with sequential detector (PS-SD). The operation characteristic for each detector and the mean acquisition time for each algorithm are derived. All the algorithms are studied in conjunction with the noncoherent integration technique, which enables the system to operate in the presence of data modulation. Several previous proposals using PNMF are seen as special cases of the present algorithms.

Su, Yu T.↗

Simultaneous observations of a theta aurora and associated magnetotail plasmas

Observations of a transpolar arc and simultaneous measurements of associated plasmas in the magnetotail lobe on March 25, 1982, are presented. The auroral imager on board Dynamics Explorer 1 observes a theta aurora in the northern polar cap for more than two hours, between 0502 and 0720 UT. ISEE 1 is located in the southern lobe of the geomagnetic tail at a distance of 22.2 R(E) during this time. The plasma and particle detectors measure intermittent bursts of particle fluxes between 0530 and 0705 UT. The observations suggest that these particle fluxes represent the high-altitude signature of a theta aurora in the southern polar cap. The relatively dense and energetic plasmas are organized into several filamentary structures. Magnetic mapping between the two polar regions indicates that the theta aurora in the Southern Hemisphere is a mirror reflection about the noon-midnight meridional plane of the theta aurora in the Northern Hemisphere.

Huang, C. Y.↗

Capabilities of GRO/OSSE for observing solar flares

The launch of the Gamma Ray Observatory (GRO) near solar maximum makes solar flare studies early in the mission particularly advantageous. The Oriented Scintillation Spectrometer Experiment (OSSE) on GRO, covering the energy range 0.05 to 150 MeV, has some significant advantages over the previous generation of satellite-borne gamma-ray detectors for solar observations. The OSSE detectors will have about 10 times the effective area of the Gamma-Ray Spectrometer (GRS) on Solar Maximum Mission (SMM) for both photons and high-energy neutrons. The OSSE also has the added capability of distinguishing between high-energy neutrons and photons directly. The OSSE spectral accumulation time (approx. 4s) is four times faster than that of the SMM/GRS; much better time resolution is available in selected energy ranges. These characteristics will allow the investigation of particle acceleration in flares based on the evolution of the continuum and nuclear line components of flare spectra, nuclear emission in small flares, the anisotropy of continuum emission in small flares, and the relative intensities of different nuclear lines. The OSSE observational program will be devoted primarily to non-solar sources. Therefore, solar observations require planning and special configurations. The instrumental and operational characteristics of OSSE are discussed in the context of undertaking solar observations. The opportunities for guest investigators to participate in solar flare studies with OSSE is also presented.

Kurfess, J. D.↗

The 3 micron spectrum of NGC 4565

Researchers spectrum of NGC 4565 is essentially featureless. The absence of the 3.0 micron feature (Tau 3.0 less than 0.05) implies that the extinction to the nucleus does not arise to a significant degree in molecular clouds. Researchers deduce Tau 3.0/A sub V less than 0.01, compared with approx. 0.022 for GC-IRS7. These results support the conclusion (McFadzean et al. 1989) that the 3.0 micron absorption in the GC-IR sources is due to the presence of ice in a (probably single) foreground molecular cloud. The 3.4 micron feature is also weak or absent in the researchers spectrum of NGC 4565 (Tau 3.4 less than or equal to 0.07), hence, Tau 3.4/A sub V less than or equal to 0.016, compared with approx. 0.008 towards GC-IRS7. The absence of the feature in NGC 4565 at the signal-to-noise level of the current observations is consistent with a probable moderate degree of extinction towards the nucleus. The observations of NGC 4565 provide a useful comparison for studies of dust in the Galaxy. Limits have been set on the strengths of the 3.0 and 3.4 micron features in NGC 4565. The absence of 3.0 micron absorption is significant, and supports the view that the feature at this wavelength in the Galactic Centre is due to water-ice absorption in a foreground molecular cloud. The non-detection of the 3.4 micron absorption is less surprising and provides indirect support for the association between this feature and the diffuse interstellar medium. The current spectrum probably represents the best that can be achieved with a single-detector instrument within reasonable integration times. It will clearly be of interest in the future to obtain spectra of higher signal-to-noise, as a positive detection of the 3.4 micron feature in an external galaxy, even at a low level, would be of considerable astrophysical significance.

Adamson, A. J.↗

Lower-hybrid collapse, caviton turbulence, and charged particle energization in the topside auroral ionosphere and magnetosphere

A scenario, first introduced by Retterer et al. (1986), is described which can result in the collapse of the lower-hybrid modes to shorter wavelengths to achieve the resonance matching with the tail region of the cold ionospheric ion distribution. The theory also predicts the simultaneous occurrence of counterstreaming electrons that are commonly observed in conjunction with the ion conics in the suprauroral region. These theoretical predictions are confirmed by recent high-altitude sounding rocket experiments utilizing innovative high time resolution wave and particle detectors.

Chang, Tom↗

Chopped molecular beam multiplexing system

The integration of a chopped molecular beam mass spectrometer with a time multiplexing system is described. The chopping of the molecular beam is synchronized with the time intervals by a phase detector and a synchronous motor. Arithmetic means are generated for phase shifting the chopper with respect to the multiplexer. A four channel amplifier provides the capacity to independently vary the baseline and amplitude in each channel of the multiplexing system.

Adams, Billy R.↗

A simulation of the intracluster medium with feedback from cluster galaxies

We detail method and report first results from a three-dimensional hydrodynamical and N-body simulation of the formation and evolution of a Coma-sized cluster of galaxies, with the intent of studying the history of the hot, X-ray emitting intracluster medium. Cluster gas, galaxies, and dark matter are included in the model. The galaxies and dark matter fell gravitational forces; the cluster gas also undergoes hydrodynamical effects such as shock heating and PdV work. For the first time in three dimensions, we include modeling of ejection of processed gas from the simulated galaxies by winds, including heating and heavy element enrichment. For comparison, we employ a `pure infall' simulation using the same initial conditions but with no galaxies or winds. We employ an extreme ejection history for galactic feedback in order to define the boundary of likely models. As expected, feedback raises the entropy of the intracluster gas, preventing it from collapsing to densities as high as those attained in the infall model. The effect is more pronounced in subclusters formed at high redshift. The cluster with feedback is always less X-ray luminous, but experiences more rapid luminosity evolution, than the pure infall cluster. Even employing an extreme ejection model, the final gas temperature is only approximately 15% larger than in the infall model. The radial temperature profile is very nearly isothermal within 1.5 Mpc. The cluster galaxies in the feedback model have a velocity dispersion approximately 15% lower than the dark matter. This results in the true ratio of specific energies in galaxies to gas being less than one, beta(sub spec) approximately 0.7. The infall model predicts beta(sub spec) approximately 1.2. Large excursions in these values occur over time, following the complex dynamical history of the cluster. The morphology of the X-ray emission is little affected by feedback. The emission profiles of both clusters are well described by the standard beta-model with beta(sub fit) approximately equal to 0.7 - 0.9. X-ray mass estimates based on the assumptions of hydrostatic equilibrium and the applicability of the beta-model are quite accurate in both cases. A strong, radial iron abundance gradient is present, which develops as a consequence of the steepening of the galaxy density profile over time. Spectroscopic observations using nonimaging detectors with wide (approximately 45 min) fields of view dramatically smear the gradient. Observations with arcminute resolution, made available with the ASCA satellite, would readily resolve the gradient.

Metzler, Christopher A.↗

The LXeCAT instrument for gamma-ray astrophysics

The Liquid Xenon Coded Aperture Telescope (LXeCAT) and its capability to image astrophysical gamma-ray sources in the MeV region is described. The gamma-ray detector is a Liquid Xenon Time Projection Chamber (LXeTPC) triggered by the primary scintillation light. Effective background rejection is a direct consequence of the intrinsic three-dimensional imaging capability of the LXeTPC. Initial results with a 10 liter prototype confirm an energy resolution of 6% FWHM, a position resolution of 1 mm RMS and a light triggering efficiency higher than 90% for 1 MeV gamma-rays.

Aprile, E.↗

Evolution of a localized Langmuir packet in the solar wind and on auroral field lines

Langmuir emissions in space are reported to be clumpy and intermittent. The high-frequency wave power appears concentrated in spatial packets, whether amidst the solar wind or on auroral field lines. Due to the plasma motion relative to the spacecraft, determining the source for the wave free energy in the three-dimensional electron distribution function has always been difficult, since the unstable features pass by the detector in presumably too short time to be measured. The range of unstable phase velocities and growth rates have generally been estimated rather than determined by unequivocal measurements. The analysis of wave-particle interactions in a space environment has taken recently a new turn with the development of wave correlators on board rockets and satellites. Such instruments seek to identify correlations between the phase of the wave-field and the fluxes of energetic particles. The data interpretation is complex, however, it must be backed by a detailed theoretical understanding of the wave-particle interaction, including the phase relation for inhomogeneous packets. To this end Langmuir packets interacting with fast electrons can be studied in the appropriate regime by means of particle-in-cell simulations, provided that one succeeds in reducing the level of the fluctuations, enhancing the signal-to-noise ratio, and incorporating the appropriate boundary conditions. The first results of such simulations are presented here as a test and expansion of previous analysis.

Roth, I.↗

Energy Scales in X-Ray Microcalorimeters

Microcalorimeter pulse shape characteristics, such as pulse height, decay time and rise time, are dependent on the detector temperature and bias as well as the photon energy and flux. We examine the nature of the temperature dependency by illuminating the ASTRO-E2 X-ray Spectrometer (XRS) microcalorimeter array with X-rays generated by electron impact on a range of foil targets. The resulting pulses are collected for a range of detector temperatures. We observe and model the temperature dependence of the pulse shape characteristics by fitting the data with non-linear pulse models. Our aim is to determine a robust method for correcting the energy scale obtained in ground calibration for slight differences in the operating conditions while in orbit.

Tillotson, W. A.↗