Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “target variability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Determinants for Efficient Editing with Cas9-Mediated Recombineering in Escherichia coli

In E. coli, editing efficiency with Cas9-mediated recombineering varies across targets due to differences in the level of Cas9:gRNA-mediated DNA double-strand break (DSB)-induced cell death. We found that editing efficiency with the same gRNA and repair template can also change with target position, cas9 promoter strength, and growth conditions. Incomplete editing, off-target activity, nontargeted mutations, and failure to cleave target DNA even if Cas9 is bound also compromise editing efficiency. These effects on editing efficiency were gRNA-specific. We propose that differences in the efficiency of Cas9:gRNA-mediated DNA DSBs, as well as possible differences in binding of Cas9:gRNA complexes to their target sites, account for the observed variations in editing efficiency between gRNAs. We show that editing behavior using the same gRNA can be modified by mutating the gRNA spacer, which changes the DNA DSB activity. Finally, we discuss how variable editing with different gRNAs could limit high-throughput applications and provide strategies to overcome these limitations.

59 BASIC BIOLOGICAL SCIENCES↗

Variational Optical Phase Learning on a Continuous-Variable Quantum Compiler

Quantum process learning is a fundamental primitive that draws inspiration from machine learning with the goal of better studying the dynamics of quantum systems. One approach to quantum process learning is quantum compilation, whereby an analog quantum operation is digitized by compiling it into a series of basic gates. While there has been significant focus on quantum compiling for discrete-variable systems, the continuous-variable (CV) framework has received comparatively less attention. We present an experimental implementation of a CV quantum compiler that uses two-mode squeezed light to learn a Gaussian unitary operation. We demonstrate the compiler by learning a parameterized linear phase unitary through the use of target and control phase unitaries to demonstrate a factor of 5.4 increase in the precision of the phase estimation and a 3.6-fold acceleration in the time-to-solution metric when leveraging quantum resources. We further show how our approach can be extended to higher-dimensional compilation tasks. Our results are enabled by the tunable control of our cost landscape via variable squeezing, thus providing a critical framework to simultaneously increase precision and reduce time-to-solution.

97 MATHEMATICS AND COMPUTING↗

Spectroscopic Analysis of Milky Way Outer Halo Satellites: Aquarius II and Boötes II

In this paper, we present a chemical and kinematic analysis of two ultrafaint dwarf galaxies (UFDs), Aquarius II (Aqu II) and Boötes II (Boo II), using Magellan/IMACS spectroscopy. We present the largest sample of member stars for Boo II (12), and the largest sample of red giant branch members with metallicity measurements for Aqu II (eight). In both UFDs, over 80% of targets selected based on Gaia proper motions turned out to be spectroscopic members. In order to maximize the accuracy of stellar kinematic measurements, we remove the identified binary stars and RR Lyrae variables. For Aqu II, we measure a systemic velocity of -65.3 ± 1.8 km s-1 and a metallicity of [Fe/H] = $-2.57^{+0.17}_{-0.17}$. When compared with previous measurements, these values display a ~6 km s -1 difference in radial velocity and a decrease of 0.27 dex in metallicity. Similarly for Boo II, we measure a systemic velocity of $-130.4^{+1.4}_{-1.1}$ km s -1 , more than 10 km s -1 different from the literature, a metallicity almost 1 dex smaller at [Fe/H] = $-2.71^{+0.11}_{-0.10}$, and a velocity dispersion 3 times smaller at σ v hel = $2.9^{+1.6}_{-1.2}$km s -1 . Additionally, we derive systemic proper-motion parameters and model the orbits of both UFDs. Finally, we highlight the extremely dark-matter-dominated nature of Aqu II and compute the J-factor for both galaxies to aid searches of dark matter annihilation. Despite the small size and close proximity of Boo II, it is an intermediate target for the indirect detection of dark matter annihilation due to its low-velocity dispersion and corresponding low dark matter density.

79 ASTRONOMY AND ASTROPHYSICS↗

Probing the Origin of Changing-look Quasar Transitions with Chandra

Extremely variable quasars can also show strong changes in broad-line emission strength and are known as changing-look quasars (CLQs). To study the CLQ transition mechanism, we present a pilot sample of CLQs with X-ray observations in both the bright and faint states. From a sample of quasars with bright-state archival SDSS spectra and (Chandra or XMM-Newton) X-ray data, we identified five new CLQs via optical spectroscopic follow-up and then obtained new target-of-opportunity X-ray observations with Chandra. No strong absorption is detected in either the bright- or the faint-state X-ray spectra. The intrinsic X-ray flux generally changes along with the optical variability, and the X-ray power-law slope becomes harder in the faint state. Large-amplitude mid-infrared variability is detected in all five CLQs, and it echoes the variability in the optical with a time lag expected from the light-crossing time of the dusty torus for CLQs with robust lag measurements. The changing-obscuration model is not consistent with the observed X-ray spectra and spectral energy distribution changes seen in these CLQs. It is highly likely that the observed changes are due to the changing accretion rate of the supermassive black hole, so the multiwavelength emission varies accordingly, with promising analogies to the accretion states of X-ray binaries.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison and validation of the QuEChERSER mega-method for determination of per- and polyfluoroalkyl substances in foods by liquid chromatography with high-resolution and triple quadrupole mass spectrometry

Instances of food contamination with per- and polyfluoroalkyl substances (PFAS) continue to occur globally, but sample preparation and analytical methods are quite limited and often monitor for a small percentage of known PFAS. This study aimed to evaluate, validate, and compare performance of two instruments with the recently developed “quick, easy, cheap, effective, rugged, safe, efficient, and robust” (QuEChERSER) sample preparation mega-method – a method developed to monitor chemicals over a broad range of physicochemical properties. Initial evaluation of the QuEChERSER mega-method for determination of PFAS in food demonstrated recoveries, matrix interferences, and co-extractive removal comparable to (or better than) US Food and Drug Administration (FDA) and USDA Food Safety and Inspection Service (FSIS) methods. Subsequent validation of QuEChERSER in beef, catfish, chicken, pork, liquid eggs, and powdered eggs on a high-resolution mass spectrometer achieved acceptable recoveries (70–120%) and precision (RSDs ≤20%) for all 33 target analytes at the 1 and 5 ng g –1 levels and 67–88% of analytes at the 0.1 ng g –1 level, depending on the matrix. Additional validation was performed by tandem mass spectrometry on a triple quadrupole instrument. This approach provided no non-detects and better recoveries at the 0.1 ng g –1 level than the HRMS method but exhibited more variability at 1 and 5 ng g –1 spiking levels. Analysis of NIST SRMs 1946 and 1947 gave accuracies of 70–117%. Furthermore, these results demonstrate the capability of combining PFAS analysis with a mega-method previously validated for 350 analytes, while collecting non-target data for future retrospective analysis of emerging alternatives with a high-resolution mass spectrometry method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inhibition of SCF ubiquitin ligases by engineered ubiquitin variants that target the Cul1 binding site on the Skp1–F-box interface

Skp1–Cul1–F-box (SCF) E3 ligases play key roles in multiple cellular processes through ubiquitination and subsequent degradation of substrate proteins. Although Skp1 and Cul1 are invariant components of all SCF complexes, the 69 different human F-box proteins are variable substrate binding modules that determine specificity. SCF E3 ligases are activated in many cancers and inhibitors could have therapeutic potential. Here, we used phage display to develop specific ubiquitin-based inhibitors against two F-box proteins, Fbw7 and Fbw11. Unexpectedly, the ubiquitin variants bind at the interface of Skp1 and F-box proteins and inhibit ligase activity by preventing Cul1 binding to the same surface. Using structure-based design and phage display, we modified the initial inhibitors to generate broad-spectrum inhibitors that targeted many SCF ligases, or conversely, a highly specific inhibitor that discriminated between even the close homologs Fbw11 and Fbw1. We propose that most F-box proteins can be targeted by this approach for basic research and for potential cancer therapies.

59 BASIC BIOLOGICAL SCIENCES↗

A novel femtosecond-gated, high-resolution, frequency-shifted shearing interferometry technique for probing pre-plasma expansion in ultra-intense laser experiments

Ultra-intense laser-matter interaction experiments (>10{sup 18} W/cm{sup 2}) with dense targets are highly sensitive to the effect of laser “noise” (in the form of pre-pulses) preceding the main ultra-intense pulse. These system-dependent pre-pulses in the nanosecond and/or picosecond regimes are often intense enough to modify the target significantly by ionizing and forming a plasma layer in front of the target before the arrival of the main pulse. Time resolved interferometry offers a robust way to characterize the expanding plasma during this period. We have developed a novel pump-probe interferometry system for an ultra-intense laser experiment that uses two short-pulse amplifiers synchronized by one ultra-fast seed oscillator to achieve 40-fs time resolution over hundreds of nanoseconds, using a variable delay line and other techniques. The first of these amplifiers acts as the pump and delivers maximal energy to the interaction region. The second amplifier is frequency shifted and then frequency doubled to generate the femtosecond probe pulse. After passing through the laser-target interaction region, the probe pulse is split and recombined in a laterally sheared Michelson interferometer. Importantly, the frequency shift in the probe allows strong plasma self-emission at the second harmonic of the pump to be filtered out, allowing plasma expansion near the critical surface and elsewhere to be clearly visible in the interferograms. To aid in the reconstruction of phase dependent imagery from fringe shifts, three separate 120° phase-shifted (temporally sheared) interferograms are acquired for each probe delay. Three-phase reconstructions of the electron densities are then inferred by Abel inversion. This interferometric system delivers precise measurements of pre-plasma expansion that can identify the condition of the target at the moment that the ultra-intense pulse arrives. Such measurements are indispensable for correlating laser pre-pulse measurements with instantaneous plasma profiles and for enabling realistic Particle-in-Cell simulations of the ultra-intense laser-matter interaction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Life cycle assessment of co-firing biomass at coal-fired power plants with carbon capture and storage toward net-zero emissions

Co-firing biomass with carbon capture and storage (BECCS) offers a technological option to decarbonize coal-fired power plants toward net-zero emissions. This study estimates the life cycle emissions of co-firing biomass at coal-fired power plants with CCS and quantifies its variability and uncertainty. Deployment of co-firing BECCS at coal-fired power plants can significantly reduce the life cycle emissions toward the net-zero target but lower the power plant performance, which vary with numerous factors, including coal type, biomass type, co-firing level, and CO 2 capture rate. The breakeven co-firing levels required for biomass at coal-fired power plants with 90 % CO 2 capture to reach net-zero emissions fall with a range roughly from 15 % to 25 % on an energy basis, depending on coal and biomass types. Increasing the CO 2 capture rate from 90 % to 95 % can lower the breakeven co-firing levels by about 5 to 8 percentage points for the biomass resources of interest, which can lower reliance on biomass resources and facilitate large-scale deployment of co-firing BECCS in fossil-rich regions but with limited biomass resources. Furthermore, findings improve the understanding of the techno-environmental performance of co-firing BECCS and inform strategic planning decisions on net-zero emissions in the coal-fired power sector.

Breakeven co-firing level↗

Long-term Cardiac Mortality After Hypofractionated Radiation Therapy in Breast Cancer

Purpose: To explore very-long-term mortality from ischemic heart disease (IHD) after locoregional radiation therapy of breast cancer (BC) in relation to degree of hypofractionation and other treatment variables. Methods and Materials: Two hypofractionated regimens used for locoregional radiation therapy for BC from 1975 to 1991 were considered. Patients received 4.3 Gy × 2/week (10 fractions; target dose 43 Gy; n=1107) or 2.5 Gy × 5/week (20 fractions; target dose 50 Gy; n=459). To estimate cardiac doses, radiation fields were reconstructed in a planning system. Time to death from IHD was the endpoint, comparing the groups with each other and with age-matched, cancer-free control individuals, modeled with the Cox proportional hazards model. Results: Patients given 4.3 Gy × 10 had an increased risk of dying of IHD compared with both the 2.5 Gy group (hazard ratio [HR] = 2.37; 95% confidence interval [CI]: 1.06-5.32; P=.036) and the control group (HR = 1.59; 95% CI: 1.13-2.23; P=.008). Photon beams for parasternal fields gave an increased risk of dying of IHD compared with electron beams (HR = 2.56; 95% CI: 1.12-5.84; P=.025). Multivariate analysis gave an increased risk for the 4.3-Gy versus 2.5-Gy regimen with borderline significance (HR = 2.90; 95% CI: 0.97-8.79; P=.057) but not for parasternal irradiation. Conclusions: The degree of hypofractionation and parasternal photon beams contributed to increased cardiac mortality in this patient cohort. Differences emerged after 12 to 15 years, indicating the need of more studies with observation time of 2 decades.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The value of fusion energy to a decarbonized United States electric grid

Fusion could be a part of future decarbonized electricity systems, but it will need to compete with other technologies. In particular, pulsed tokamak plants have a unique operational mode, and evaluating which characteristics make them economically competitive can help select between design pathways. Using a capacity expansion and operations model, here we determined cost thresholds for pulsed tokamaks to reach a range of penetration levels in a future decarbonized US Eastern Interconnection. The required capital cost to reach a fusion capacity of 100 GW varied from $2,700 to $7,500 kW -1 , and the equilibrium penetration increases rapidly with decreasing cost. The value per unit power capacity depends on the variable operational cost and on the cost of its competition, particularly fission, much more than on the pulse cycle parameters. These findings can therefore provide initial cost targets for fusion more generally in the United States.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A memory-distributed quasi-Newton solver for nonlinear programming problems with a small number of general constraints

We approach the problem of parallelizing state-of-the-art nonlinear programming optimization algorithms.Specifically, we focus on parallelizing quasi-Newton interior-point methods that use limited-memory secant Hessian approximations. Such interior-point methods are known to have better convergence properties and to be more effective on large-scale problems than gradient-based and derivative-free optimization algorithms. We target nonlinear and potentially nonconvex optimization problems with an arbitrary number of bound constraints and a small number of general equality and inequality constraints on the optimization variables. These problems occur for example in the form of optimal control, optimal design, and inverse problems governed by ordinary or partial differential equations, whenever they are expressed in a “reduced-space” optimization approach. We introduce and analyze the time and space complexity of a decomposition method for solving the quasi-Newton linear systems that leverages the fact that the quasi-Newton Hessian matrix has a small number of dense blocks that border a low-rank update of a diagonal matrix. This enables an efficient parallelization on memory-distributed computers of the iterations of the optimization algorithm, a state-of-the-art filter line-search interior-point algorithm by Wächter et. al. We illustrate the efficiency of the proposed method by solving structural topology optimization problems on up to 4608 cores on a parallel machine.

97 MATHEMATICS AND COMPUTING↗

Feasibility study of volumetric modulated arc therapy with constant dose rate for endometrial cancer

To investigate the feasibility, efficiency, and delivery accuracy of volumetric modulated arc therapy with constant dose rate (VMAT-CDR) for whole-pelvic radiotherapy (WPRT) of endometrial cancer. The nine-field intensity-modulated radiotherapy (IMRT), VMAT with variable dose-rate (VMAT-VDR), and VMAT-CDR plans were created for 9 patients with endometrial cancer undergoing WPRT. The dose distribution of planning target volume (PTV), organs at risk (OARs), and normal tissue (NT) were compared. The monitor units (MUs) and treatment delivery time were also evaluated. For each VMAT-CDR plan, a dry run was performed to assess the dosimetric accuracy with MatriXX from IBA. Compared with IMRT, the VMAT-CDR plans delivered a slightly greater V{sub 20} of the bowel, bladder, pelvis bone, and NT, but significantly decreased the dose to the high-dose region of the rectum and pelvis bone. The MUs decreased from 1105 with IMRT to 628 with VMAT-CDR. The delivery time also decreased from 9.5 to 3.2 minutes. The average gamma pass rate was 95.6% at the 3%/3 mm criteria with MatriXX pretreatment verification for 9 patients. VMAT-CDR can achieve comparable plan quality with significant shorter delivery time and smaller number of MUs compared with IMRT for patients with endometrial cancer undergoing WPRT. It can be accurately delivered and be an alternative to IMRT on the linear accelerator without VDR capability.

61 RADIATION PROTECTION AND DOSIMETRY↗

Seasonality and Declining Intensity of Methane Emissions from the Permian and Nearby US Oil and Gas Basins

We quantify weekly methane emissions and trends from oil and gas production in the US Permian Basin for 2019-2023, and in nearby basins for 2022-2023, by analytical inversion of Tropospheric Monitoring Instrument (TROPOMI) satellite observations with the Integrated Methane Inversion (IMI) at 25 km resolution. Permian oil and gas emissions averaged 4.0 ± 1.1 Tg a-1 over 2019-2023, with large seasonal variation but little interannual variability. Methane intensity fell from 5.2 to 3.2% as production surged. Intensity in the New Mexico Permian fell from 4.5 to 2.1%, approaching the state's 2026 target of <2%. Emissions were on average 50 ± 10% higher in winter than summer, which we corroborate with Permian Basin Tower Network measurements, Insight M aircraft data, and GHGSat satellite observations. This seasonality may be driven in part by higher winter emissions from liquid storage tanks due to decreased separator efficiency in cold conditions. Similar but weaker seasonality along with decreasing emissions and intensities is found in weekly inversions for the Anadarko, Barnett, Eagle Ford, and Haynesville basins in 2022-2023. Our work suggests that better weatherization of oil and gas facilities could significantly reduce methane emissions.

Permian↗

Model evaluation guidelines for geomagnetic index predictions

Geomagnetic indices are convenient quantities that distill the complicated physics of some region or aspect of near–Earth space into a single parameter. Most of the best–known indices are calculated from ground–based magnetometer data sets, such as Dst, SYM–H, Kp, AE, AL, and PC. Many models have been created that predict the values of these indices, often using solar wind measurements upstream from Earth as the input variables to the calculation. This document reviews the current state of models that predict geomagnetic indices and the methods used to assess their ability to reproduce the target index time series. These existing methods are synthesized into a baseline collection of metrics for benchmarking a new or updated geomagnetic index prediction model. These methods fall into two categories: (1) fit performance metrics such as root mean square error (RMSE) and mean absolute error (MAE) that are applied to a time–series comparison of model output and observations; and (2) event detection performance metrics such as Heidke Skill Score and probability of detection (POD) that are derived from a contingency table that compares model and observation values exceeding (or not) a threshold value. Furthermore, a few examples of codes being used with this set of metrics are presented, and other aspects of metrics assessment best practices, limitations, and uncertainties are discussed, including several caveats to consider when using geomagnetic indices.

79 ASTRONOMY AND ASTROPHYSICS↗

A new class of variable-radii diffraction optics for high-resolution x-ray spectroscopy at the National Ignition Facility (invited)

A new class of crystal shapes has been developed for x-ray spectroscopy of point-like or small (a few mm) emission sources. These optics allow for dramatic improvement in both achievable energy resolution and total throughput of the spectrometer as compared with traditional designs. This class of crystal shapes, collectively referred to as the Variable-Radii Spiral (VR-Spiral), utilize crystal shapes in which both the major and minor radii are variable. A crystal using this novel VR-Spiral shape has now been fabricated for high-resolution Extended X-ray Absorption Fine Structure (EXAFS) experiments targeting the Pb-L 3 (13.0 keV) absorption edge at the National Ignition Facility. The performance of this crystal has been characterized in the laboratory using a microfocus x-ray source, showing that high-resolution high-throughput EXAFS spectra can be acquired using this geometry. Importantly, these successful tests show that the complex three-dimensional crystal shape is manufacturable with the required precision needed to realize the expected performance of better than 5 eV energy resolution while using a 30 mm high crystal. An improved generalized mathematical form for VR-Spiral shapes is also presented allowing improved optimization as compared to the first sinusoidal-spiral based design. Finally, this new formulation allows VR-Spiral spectrometers to be designed at any magnification with optimized energy resolution at all energies within the spectrometer bandwidth.

47 OTHER INSTRUMENTATION↗

Iterative self-organizing SCEne-LEvel sampling (ISOSCELES) for large-scale building extraction

Convolutional neural networks (CNN) provide state-of-the-art performance in many computer vision tasks, including those related to remote-sensing image analysis. Successfully training a CNN to generalize well to unseen data, however, requires training on samples that represent the full distribution of variation of both the target classes and their surrounding contexts. With remote sensing data, acquiring a sufficiently representative training set is a challenge due to both the inherent multi-modal variability of satellite or aerial imagery and the general high cost of labeling data. To address this challenge, we have developed ISOSCELES, an Iterative Self-Organizing SCEne LEvel Sampling method for hierarchical sampling of large image sets. Using affinity propagation, ISOSCELES automates the selection of highly representative training images. Compared to random sampling or using available reference data, the distribution of the training is principally data driven, reducing the chance of oversampling uninformative areas or undersampling informative ones. In comparison to manual sample selection by an analyst, ISOSCELES exploits descriptive features, spectral and/or textural, and eliminates human bias in sample selection. Using a hierarchical sampling approach, ISOSCELES can obtain a training set that reflects both between-scene variability, such as in viewing angle and time of day, and within-scene variability at the level of individual training samples. We verify the method by demonstrating its superiority to stratified random sampling in the challenging task of adapting a pre-trained model to a new image and spatial domain for country-scale building extraction. Using a pair of hand-labeled training sets comprising 1,987 sample image chips, a total of 496,000,000 individually labeled pixels, we show, across three distinct model architectures, an increase in accuracy, as measured by F1-score, of 2.2–4.2%.

42 ENGINEERING↗

SEARCHES FOR MILLISECOND PULSAR CANDIDATES AMONG THE UNIDENTIFIED FERMI OBJECTS

Here we report the results of searching millisecond pulsar (MSP) candidates from the Fermi LAT second source catalog (2FGL). Seven unassociated γ-ray sources in this catalog are identified as promising MSP candidates based on their γ-ray properties. Through the X-ray analysis, we have detected possible X-ray counterparts, localized to an arcsecond accuracy. We have systematically estimated their X-ray fluxes and compared them with the corresponding γ-ray fluxes. The X-ray to γ-ray flux ratios for 2FGL J1653.6-0159 and 2FGL J1946.4-5402 are comparable with the typical value for pulsars. For 2FGL J1625.2-0020, 2FGL J1653.6-0159, and 2FGL J1946.4-5402, their candidate X-ray counterparts are bright enough to perform a detailed spectral and temporal analysis to discriminate their thermal/non-thermal nature and search for the periodic signal. We have also searched for possible optical/IR counterparts at the X-ray positions. For the optical/IR source coincident with the brightest X-ray object associated with 2FGL J1120.0-2204, its spectral energy distribution is comparable with a late-type star. Evidence for the variability has also been found by examining its optical light curve. All the aforementioned 2FGL sources resemble a pulsar in one or more aspects, making them promising targets for follow-up investigations.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-421: Feasibility Study of Volumetric Modulated Arc Therapy with Constant Dose Rate for Endometrial Cancer

Purpose: To investigate the feasibility, efficiency, and delivery accuracy of volumetric modulated arc therapy with constant dose rate (VMAT-CDR) for whole-pelvic radiotherapy (WPRT) of endometrial cancer. Methods: The nine-Field intensity-modulated radiotherapy (IMRT), VMAT with variable dose-rate (VMAT-VDR), and VMAT-CDR plans were created for 9 patients with endometrial cancer undergoing WPRT. The dose distribution of planning target volume (PTV), organs at risk (OARs), and normal tissue (NT) were compared. The monitor units (MUs) and treatment delivery time were also evaluated. For each VMAT-CDR plan, a dry Run was performed to assess the dosimetric accuracy with MatriXX from IBA. Results: Compared with IMRT, the VMAT-CDR plans delivered a slightly greater V20 of the bowel, bladder, pelvis bone, and NT, but significantly decreased the dose to the high-dose region of the rectum and pelvis bone. The MUs Decreased from 1105 with IMRT to 628 with VMAT-CDR. The delivery time also decreased from 9.5 to 3.2 minutes. The average gamma pass rate was 95.6% at the 3%/3 mm criteria with MatriXX pretreatment verification for 9 patients. Conclusion: VMAT-CDR can achieve comparable plan quality with significant shorter delivery time and smaller number of MUs compared with IMRT for patients with endometrial cancer undergoing WPRT. It can be accurately delivered and be an alternative to IMRT on the linear accelerator without VDR capability. This work is supported by the grant project, National Natural; Science Foundation of China (No. 81071237)

60 APPLIED LIFE SCIENCES↗