SEARCH · Engineering Papers
Results for “systems”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A performance comparison of current HPC systems: Blue Gene/Q, Cray XE6 and InfiniBand systems
We present here a performance analysis of three of current architectures that have become commonplace in the High Performance Computing world. Blue Gene/Q is the third generation of systems from IBM that use modestly performing cores but at large-scale in order to achieve high performance. The XE6 is the latest in a long line of Cray systems that use a 3-D topology but the first to use its Gemini interconnection network. InfiniBand provides the flexibility of using compute nodes from many vendors that can be connected in many possible topologies. The performance characteristics of each vary vastly, and the way in which nodes are allocated in each type of system can significantly impact on achieved performance. In this work we compare these three systems using a combination of micro-benchmarks and a set of production applications. In addition we also examine the differences in performance variability observed on each system and quantify the lost performance using a combination of both empirical measurements and performance models. Our results show that significant performance can be lost in normal production operation of the Cray XE6 and InfiniBand Clusters in comparison to Blue Gene/Q.
Land system architecture: Using land systems to adapt and mitigate global environmental change
Land systems (mosaics of land use and cover) are human environment systems, the changes in which drive and respond to local to global environmental changes, climate to macro-economy (Foley et al., 2005). Changes in land systems have been the principal proximate cause in the loss of habitats and biota globally, long contributed to atmospheric greenhouse gases, and hypothesized to have triggered climate changes in the early Holocene (Ruddiman, 2003). Land use, foremost agriculture, is the largest source of biologically active nitrogen to the atmosphere, critical to sources and sinks of carbon, and a major component in the hydrologic cycle (e.g., Bouwman et al., 2011). Changes in land systems also affect regional climate (Feddema et al., 2005; Pielke, 2005), ecosystem functions, and the array of ecosystem services they provide. Land systems, therefore, are a central feature of how humankind manages its relationship with nature-intended or not, or whether this relationship proceeds sustainably or not.
A rule-based phase control methodology for a slider-crank wave energy converter power take-off system
Not Available
Towards understanding HPC users and systems: A NERSC case study
High performance computing (HPC) scheduling landscape currently faces new challenges due to thechanges in the workload. Previously, HPC centers were dominated by tightly coupled MPI jobs. HPCworkloads increasingly include high-throughput, data-intensive, and stream-processing applications. Asa consequence, workloads are becoming more diverse at both application and job levels, posing newchallenges to classical HPC schedulers. There is a need to understand the current HPC workloads andtheir evolution to facilitate informed future scheduling research and enable efficient scheduling in futureHPC systems.In this paper, we present a methodology to characterize workloads and assess their heterogeneity,at a particular time period and its evolution over time. We apply this methodology to the workloads ofthree systems (Hopper, Edison, and Carver) at the National Energy Research Scientific Computing Center(NERSC). We present the resulting characterization of jobs, queues, heterogeneity, and performance thatincludes detailed information of a year of workload (2014) and evolution through the systems’ lifetime(2010–2014).
Conversion of the LLNL/CAMS 1 MV biomedical AMS system to a semi-automated natural abundance 14C spectrometer: system optimization and performance evaluation
The Lawrence Livermore National Laboratory – Center for Accelerator Mass Spectrometry compact 1 MV biomedical accelerator mass spectrometer was repurposed and optimized for the semi-automated radiocarbon measurement of natural abundance environmental samples. Here we present results from 15 months of routine system operation and evaluate the system performance based on 30 sample wheels measured with consistent operating conditions over 7 months from August 2019 to March 2020. Additionally, the average measurement precision was 2.7 ± 0.7‰. System accuracy was assessed with measurements of 14 C-free materials, standard materials with 14 C-content spanning 0.5 to 1.5 F 14 C, and by comparison to split samples measured with the 10 MV AMS system. Overall, this system can routinely measure samples as small as 300 µgC and less than 33000 years without the need for size-specific correction protocols.
Impacts of valuing resilience on cost-optimal PV and storage systems for commercial buildings
Not Available
Understanding ice cloud-precipitation properties of three modes of mesoscale convective systems during PECAN
This study analyzes the precipitation and ice cloud microphysical features of three common modes of linear mesoscale convective systems (MCSs) during the Plains Elevated Convection at Night (PECAN) campaign. Three cases, one for each linear MCS archetype (trailing stratiform (TS), leading stratiform (LS), and parallel stratiform (PS) precipitation), are selected. We focus primarily on analyzing ice cloud microphysical properties and precipitation rates over the classified convective core (CC) and stratiform rain (SR) regions, as well as the two stratiform regions that developed behind (SR1) and ahead (SR2) of the convective line relative to the storm motion. In the three selected cases, the ice water path (IWP) and precipitation rate (PR) have strong correlations in the CC, but not in the SR. In terms of the temporal evolution of the mean IWPs and PRs, both CC and SR IWPs, as well as CC PRs, reach peaks quickly, but take a longer time to dissipate than the increase period. For all three cases, both SR1 and SR2 IWPs are 20-70% of their corresponding CC values in both the LS and PS cases, and up to 95% for the TS case, while all of their PRs are only 7-25% of their CC values. These values suggest that the SR PRs may not only depend on IWPs, but also that the microphysical properties of ice particles such as habit and size distribution may play an important role. Utilizing cloud resolving simulations of these systems may provide better understanding of the physical meanings behind the results in the future.
Stochastic approximation methods-Powerful tools for simulation and optimization: A survey of some recent work on multi-agent systems and cyber-physical systems
Stochastic approximation methods have found extensive and diversified applications. Recent emergence of networked systems and cyber-physical systems has generated renewed interest in advancing stochastic approximation into a general framework to support algorithm development for information processing and decisions in such systems. This paper presents a survey on some recent developments in stochastic approximation methods and their applications. Using connected vehicles in platoon formation and coordination as a platform, we highlight some traditional and new methodologies of stochastic approximation algorithms and explain how they can be used to capture essential features in networked systems. Distinct features of networked systems with randomly switching topologies, dynamically evolving parameters, and unknown delays are presented, and control strategies are provided.
Near equilibrium distributions for beams with space charge in linear and nonlinear periodic focusing systems
Not Available
Explicit high-order non-canonical symplectic particle-in-cell algorithms for Vlasov-Maxwell systems
Not Available
Comparison of the dose distribution obtained from dosimetric systems with intensity modulated radiotherapy planning system in the treatment of prostate cancer
The aim of this study is to compare Intensity Modulated Radiation Therapy (IMRT) plan of prostate cancer patients with different dose verification systems in dosimetric aspects and to compare these systems with each other in terms of reliability, applicability and application time. Dosimetric control processes of IMRT plan of three prostate cancer patients were carried out using thermoluminescent dosimeter (TLD), ion chamber (IC) and 2D Array detector systems. The difference between the dose values obtained from the dosimetric systems and treatment planning system (TPS) were found to be about % 5. For the measured (TLD) and calculated (TPS) doses %3 percentage differences were obtained for the points close to center while percentage differences increased at the field edges. It was found that TLD and IC measurements will increase the precision and reliability of the results of 2D Array.
Upgraded Divertor Thomson Scattering System on DIII-D
Explore the source record for details and available documents.
W-band system-on-chip electron cyclotron emission imaging system on DIII-D
Monolithic, millimeter wave “system-on-chip” (SoC) technology has been employed in heterodyne receiver integrated circuit radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature profile and fluctuation evolution diagnostics. Here, a prototype module operating in E-band (72-80 GHz) was first employed in a 2 x 10 element array that demonstrated significant improvements over the previous quasi-optical Schottky diode mixer arrays during the 2018 operational campaign of the DIII-D tokamak. For compatibility with International Thermonuclear Experimental Reactor (ITER) relevant scenarios on DIII-D, the SoC ECEI system was upgraded with 20 horn-waveguide receiver modules. Each individual module contains a University of California at Davis designed W-band (75 -110 GHz) receiver die that integrates a broadband low noise amplifier (LNA), a double balanced down-converting mixer, and a x4 multiplier on the local oscillator (LO) chain. A x2 multiplier and two IF amplifiers are packaged and selected to further boost the signal strength as well as downconvert the signal frequency. The upgraded W-band array exhibits > 30 dB additional gain and 20x improvement in noise temperature comparing with the previous Schottky diode radio frequency (RF) mixer input systems; an internal 8 times multiplier chain is used to bring down the LO frequency below 12 GHz, thereby obviating the need for a large aperture for quasi-optical LO coupling and replacing it with coaxial connectors. The horn-waveguide shielding housing avoids out-of-band noise interference on each individual module. The upgraded ECEI system plays an important role for absolute electron temperature evolution and fluctuation measurements for edge and core region transport physics studies.
Lighting System Control Data to Improve Design and Operation: Tunable Lighting System Data from NICU Patient Rooms
The advancement of LED and controls technology, computing capacity, and software provides new opportunities for researchers and designers to work together to further optimize spaces for occupant benefit. Here, lighting system control data from five neonatal intensive care unit patient rooms was collected over a 25-week monitoring period and analyzed to better understand occupant response to a tunable lighting system with automatic transitions throughout the day. Lighting systems are very rarely refined after installation based on actual use. Objective data detailing how the lighting system is used by the actual occupants highlights the opportunities for optimization after installation and provides insight for improving the next design. As use of the data becomes more commonplace, it can be leveraged for design recommendations. The collection of the data required no additional cost beyond the time for examining the data. The analysis revealed several clear opportunities for improvement, including adjustments to the default control setting at night, re-labeling of the control stations, and adjustments to the nighttime fade rate. The patient room occupants were active users of the different zones, dimming options, and manual overrides made available by the lighting system.
Platform for Automated Anomaly Detection in the Mercury Process System at the Target System in the Spallation Neutron Source
The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory accelerates proton beams, which are directed toward a mercury target to generate the world’s most intense neutron beams via spallation. The target system consists of several interconnected subsystems and accounts for a major share of the facility’s overall downtime. Early detection of anomalies in the target system response can thus provide the possibility of taking corrective actions to reduce downtime. Accelerator facilities have largely focused on the beam side for data-driven fault prognostics. On the target side, SNS relies on operational shift technicians (OSTs), who respond to alarms and manually flag anomalies onto the System Tracking and Reliability (STAR) platform. This paper presents one of the first studies of using machine learning (ML) to automate anomaly detection in the target system. The study focused on the mercury process system as the first use case and employed reconstruction-based anomaly detection on minutely sampled time series signals. The pipeline was integrated into the STAR platform to autonomously rank and flag anomalies every week. The STAR platform provides a user interface for the OSTs to evaluate the flagged anomalies, thereby incorporating human feedback.
PIP-II Cryogenic System and the evolution of Superfluid Helium Cryogenic Plant Specifications
The PIP-II cryogenic system consists of a Superfluid Helium Cryogenic Plant (SHCP) and a Cryogenic Distribution System (CDS) connecting the SHCP to the Superconducting (SC) Linac consisting of 25 cryomodules. The dynamic heat load of the SC cavities for continuous wave (CW) as well as pulsed mode of operation has been listed out. The static heat loads of the cavities along with the CDS have also been discussed. Simulation study has been carried out to compute the supercritical helium (SHe) flow requirements for each cryomodule. Comparison between the flow requirements of the cryomodules for the CW and pulsed modes of operation have also been made. From the total computed heat load and pressure drop values in the CDS, the basic specifications for the SHCP, required for cooling the SC Linac, have evolved.