Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

NASA’s Quiet Electric ENgines (QUEEN): Thermal Analysis and Testing of the Electronic Speed Controller (ESC)

An electric ducted fan system was tested at the NASA Glenn Research Center. Main components of the system include a commercial-off-the-Shelf (COTS) fan and motor, electronic speed controller, and cooling system. Motor speed, voltage, current, and temperatures were measured in this static ground test of the propulsor. The thermal performance of the Electronic Speed Controller (ESC) was also measured using two different methods to cool the ESC: air cooling and cold plate cooling. This propulsor prototype is one of NASA’s Quiet Electric ENgines (QUEENs) and is designated the ‘QUEEN V1.’ The Quiet Electric Engines are being developed for the 25% scale model of the Subsonic Single Aft Engine (SUSAN) Flight Research Vehicle and are intended to explore the potential of distributed electric propulsion for large regional single-aisle aircraft. Lessons learned will be used to guide development of future QUEEN prototypes and thermal management systems.

Firas G Asfoor↗

Epoxy nanodielectrics fabricated with in situ and ex situ techniques

In this study, we report fabrication and characterisation of a nanocomposite system composed of a commercial resin and extremely small (several nanometres in diameter) titanium dioxide particles. Nanoparticles were synthesised in situ with particle nucleation occurring inside the resin matrix. In this nanodielectric fabrication method, the nanoparticle precursor was mixed to the resin solution, and the nanoparticles were in situ precipitated. Note that no high shear mixing equipment was needed to improve particle dispersion - nanoparticles were distributed in the polymer matrix uniformly since particle nucleation occurs uniformly throughout the matrix. The properties of in situ nanodielectrics are compared to the unfilled resin and an ex situ nanocomposite. We anticipate that the presented in situ nanocomposite would be employed in high-temperature superconductivity applications. In additions, the improvement shown in the dielectric breakdown indicates that conventional high-voltage components and systems can be reduced in size with novel nanodielectrics.

36 MATERIALS SCIENCE↗

Development of copper thiolate organometallic compound as thermal sensitive coating for energy storage system safety

Safety and reliability are primary concerns for the deployment of lithium-ion batteries, especially in electric vehicles (EV) and larger-scale energy storage systems (ESS). Current technology in battery management systems (BMS) includes cell voltage monitoring and positioning temperature sensors in selected locations. For a system with hundreds to thousands of individual batteries, single-point temperature monitoring is inadequate to detect hot spots and cell overheating, which could lead to thermal runaway. Here, we have developed a temperature-sensitive copper-thiol compound that can be directly coated onto battery pouch foils to enable early detection of thermal runaway. Upon reaching specific temperatures, this compound releases a sulfur-containing detectable gas, which can be identified using chemically specific gas sensors to trigger an early warning signal. Such a signal propagate through air offers broad signal coverage and enables a more comprehensive approach to large-area temperature monitoring. The Cu-ethanethiol coating is designed to release volatile gases when the substrate surface temperature exceeds 70 °C, with continuous outgassing as the temperature increases. The compound is composed of Cu, S, Cl, hydrocarbons and trace amounts of oxygen. Upon heating, the oxidation state of Cu(I) transitions to Cu (II), accompanied by gas release. Thermogravimetric analysis coupled with mass spectrometry correlated well with the onset of gas release temperature and emission of sulfur-containing volatile gases. Additionally, an acrylic overcoat is applied to enhance the adhesion of the thermally sensitive compound film to the battery pouch foil. This coating is expected to offer an additional safety layer for ESS, alerting possible thermal runaway events before a failure occurs, thereby allowing sufficient time to implement a mitigation plan.

Early warning systems↗

A spark gap switching system for gasdynamic facilities

A spark gap switching system has been developed to coordinate the discharge of a 300 kJ capacitor bank with the high speed flow of helium in a shock tube driver. The trigger system includes a flow transducer, a pulse forming circuit, a high voltage spark generator, and four heavy duty spark gaps that can carry total peak currents greater than 1.5 million A. A glow gauge flow transducer sensitive to small gas density changes was used whose input power and signal output can withstand high voltage fluctuations. This switching system is of use with gasdynamic discharge devices requiring a minimum number of switches.

Leibowitz, L. P.↗

SP-100 Dynamic Power and Lithium-Propellant MPD Nuclear Electric Propulsion Technology Requirements

The objective of this study was to evaluate the requirements (including system integration, design, test requirements, and schedule) for the propulsion and power conversion systems of a nuclear electric propulsion (NEP) vehicle using an SP-100 reactor with a dynamic power conversion system, Li-propellant magnetoplasmadynamic (MPD) thrusters, Li-propellant storage and feed systems, and the power conditioning electronics required to convert the power output from the power system to the form (voltage, current) needed by the thrusters. Potassium-Rankine power conversion systems have the potential for the greatest mission benefit in terms of minimum mass and volume (as compared to Brayton or Stirling power conversion systems), but they require the most development.

Murray, Kathy H.↗

Models and methods for assessing the value of HVDC adn MVDC technologies in modern power grids (Annual Report, Executive Summary)

Evolution of today’s predominantly alternating current (ac) transmission grid in to mixed ac transmission – high-voltage direct current (HVdc) systems is expected with the decreasing costs of and advancements in power electronics technologies. The recent technological advancements include the development of more efficient and compact voltage source converters (VSCs) that can provide fast response. Because of their controllability and fast response, HVdc systems provide the ability to enhance reliability of the ac transmission grid through frequency support, voltage control, and congestion relief. The HVdc systems can also provide other ancillary services to enhance the economics and reliability of the ac transmission grids, and to optimize their performance. The tools, models, and methods developed to evaluate their benefits will be key enablers to understanding the value proposition introduced by the fast-acting HVdc systems. The main motivation of this work was to develop models and methods to explore and quantify the technical and economic benefits of HVdc systems and fast response VSC technologies in the future grid of United States. The models and methods explore the benefits of HVdc systems through provision of controlled active/reactive power and fast response. The fast response can provide much-needed multiobjective services to the grid (e.g., frequency response, voltage control) while moving blocks of energy. The models and methods can be applied to study other power electronics technologies and scenarios such as those undertaken in ongoing studies led by the North American Electric Reliability Corporation (NERC) Inverter-based Resource Performance Task Force (IRPTF). The IRPTF studies identify the problems associated with power electronics-based technologies as they are integrated in to the bulk power system (or the ac transmission system).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimizing Voltage Control for Large-Scale Solar

Learn how NREL researchers, working with GE’s Grid Solution business and Duke Energy, used an advanced distribution management system to better manage voltage swings from utility-scale photovoltaic systems. The research brought NREL’s extensive power-hardware-in-the-loop and modeling capabilities together with real data from Duke Energy and GE’s advanced distribution management system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Durable, Inexpensive and Scalable Redox Flow Battery Based on Iron Sulfate and Anthraquinone Disulfonic Acid

A new redox flow battery system based on iron sulfate and anthraquinone disulfonic acid (AQDS) is shown here to have excellent electrical performance, capacity retention, and chemical durability. While these redox couples, iron(II)/iron(III) and AQDS are well known individually, their combination in a redox flow battery is shown here for the first time to provide unique benefits for large-scale energy storage. Based on iron sulfate, a waste product of the steel industry, the active materials cost for this battery is anticipated to be $66/kWh. Cycling studies of over 500 cycles in the symmetric cell configuration show a negligibly low capacity fade rate of 7.6 × 10 −5 % per cycle. This symmetric cell also shows a notably high average coulombic efficiency of 99.63%. Using a graphite felt electrode modified with multi-walled carbon nanotubes (MWCNTs), we could achieve a peak power density of 194 mW cm −2 . The major voltage losses are ascribed to the ohmic resistance of the electrode and electrolyte. Despite the lower cell voltage of the system relative to the vanadium flow battery, the iron–AQDS flow battery system presents a good prospect for simultaneously meeting the demanding requirements of cost, durability and scalability for large-scale sustainable energy storage.

Yang, Bo↗

Endogenous Interface Pricing for Consistent Transmission–Distribution Co-Optimization With Discrete Distribution Controls

This paper proposes an endogenous interface pricing model for day-ahead transmission–distribution co-optimization that co-determines the interface locational marginal price (LMP) and the transmission–distribution exchange, ensuring price–dispatch consistency while optimally scheduling discrete distribution controls. The formulation couples a DC optimal power flow (OPF) with a branch-flow AC OPF that schedules distributed energy resources (DERs), tap-changer settings, capacitor banks (CBs), and multi-period energy storage systems (ESSs) under feeder voltage and current limits, and is solved as a mixed-integer second-order cone program (MISOCP). In a T14–D33 system, coordinated device scheduling recovers about 90% of the distribution-to-transmission export achievable in a reference case that ignores distribution network (DN) limits, while satisfying a 1.05 p.u. voltage upper bound. In a T39–D34/D37/D123 system, a sequential decoupled benchmark produces interface LMP distortions up to 12.5% and a 7.28% mismatch in net export energy, whereas the proposed model removes these distortions and the associated settlement mismatches. Second-order cone (SOC) relaxation gaps remain below $10^{-3}$ in all cases.

Noh, Seung-Gil↗

Ferroelectric opening switches for large-scale pulsed power drivers.

Fast electrical energy storage or Voltage-Driven Technology (VDT) has dominated fast, high-voltage pulsed power systems for the past six decades. Fast magnetic energy storage or Current-Driven Technology (CDT) is characterized by 10,000 X higher energy density than VDT and has a great number of other substantial advantages, but it has all but been neglected for all of these decades. The uniform explanation for neglect of CDT technology is invariably that the industry has never been able to make an effective opening switch, which is essential for the use of CDT. Most approaches to opening switches have involved plasma of one sort or another. On a large scale, gaseous plasmas have been used as a conductor to bridge the switch electrodes that provides an opening function when the current wave front propagates through to the output end of the plasma and fully magnetizes the plasma - this is called a Plasma Opening Switch (POS). Opening can be triggered in a POS using a magnetic field to push the plasma out of the A-K gap - this is called a Magnetically Controlled Plasma Opening Switch (MCPOS). On a small scale, depletion of electron plasmas in semiconductor devices is used to affect opening switch behavior, but these devices are relatively low voltage and low current compared to the hundreds of kilo-volts and tens of kilo-amperes of interest to pulsed power. This work is an investigation into an entirely new approach to opening switch technology that utilizes new materials in new ways. The new materials are Ferroelectrics and using them as an opening switch is a stark contrast to their traditional applications in optics and transducer applications. Emphasis is on use of high performance ferroelectrics with the objective of developing an opening switch that would be suitable for large scale pulsed power applications. Over the course of exploring this new ground, we have discovered new behaviors and properties of these materials that were here to fore unknown. Some of these unexpected discoveries have lead to new research directions to address challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Olkiluoto 1 and 2 - Plant efficiency improvement and lifetime extension-project (PELE) implemented during outages 2010 and 2011

Teollisuuden Voima Oyj (TVO) is a non-listed public company founded in 1969 to produce electricity for its stakeholders. TVO is the operator of the Olkiluoto nuclear power plant. TVO follows the principle of continuous improvement in the operation and maintenance of the Olkiluoto plant units. The PELE project (Plant Efficiency Improvement and Lifetime Extension), mainly completed during the annual outages in 2010 and 2011, and forms one part of the systematic development of Olkiluoto units. TVO maintains a long-term development program that aims at systematically modernizing the plant unit systems and equipment based on the latest technology. According to the program, the Olkiluoto 1 and Olkiluoto 2 plant units are constantly renovated with the intention of keeping them safe and reliable, The aim of the modernization projects is to improve the safety, reliability, and performance of the plant units. PELE project at Olkiluoto 1 was done in 2010 and at Olkiluoto 2 in 2011. The outage length of Olkiluoto 1 was 26 d 12 h 4 min and Olkiluoto 2 outage length was 28 d 23 h 46 min. (Normal service-outage is about 14 days including refueling and refueling-outage length is about seven days. See figure 1) The PELE project consisted of several single projects collected into one for coordinated project management. Some of the main projects were as follows: - Low pressure turbines: rotor, stator vane, casing and turbine instrumentation replacement. - Replacement of Condenser Cooling Water (later called seawater pumps) pumps - Replacement of inner isolation valves on the main steam lines. - Generator and the generator cooling system replacement. - Low voltage switchgear replacement. This project will continue during future outages. PELE was a success. 100 TVO employees and 1500 subcontractor employees participated in the project. The execution of the PELE projects went extremely well during the outages. The replacement of the low pressure turbines and seawater pumps improved the efficiency of the plant units, and a power increase of nearly 20 MW was achieved at both plant units. PELE wonderfully manifests one of the strategic goals of our company; developing the competence of our in-house personnel by working in projects. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analytical Expression for DC Link Capacitor Current in a Cascaded H-Bridge Multi-Level Active Front-End Converter

Medium-voltage grid-tied systems often use a cascaded H-bridge multi-level active front-end. In this converter, dc link bus capacitors play an important role in stabilizing the converter and enabling both active and reactive power injections. The present work provides analytical expressions for the capacitor current, which are essential for optimizing system design (especially capacitor size vs. lifetime). Then, the expression is incorporated into the grid connected bidirectional power system model. Consequently, this work contributes to the guiding principles to choose accurate dc link capacitor ratings against grid-side power delivery requirements. The analytical results have been validated with detailed simulations and hardware results.

cascaded H-bridge, carrier-based PWM, dc-link capa↗

Dual expression of constitutively active Gαs-protein-coupled receptors differentially establishes the resting activity of the cAMP-gated HCN2 channel in a single compartment

Highlights: • Constitutively active GPCRs were dually expressed in a single compartment. • HCN2 channels were differentially activated depending on the GPCR pairs. • Basal actions of GPCRs were abolished by an adenylate cyclase inhibitor. • Basal cAMP pools were specifically established by constitutively active GPCR pairs. The hyperpolarization-activated cyclic nucleotide-gated 2 (HCN2) channel is a major subtype of the HCN channel family expressed in the nervous system that sets the membrane potential, regulates cell excitability and senses changes in the extracellular environment. Neurons express various Gα{sub s}-protein-coupled receptors (GPCRs), many of which show ligand-independent constitutive activity. These membrane-bound proteins are expressed in various subcellular compartments of neurons. Therefore, some proportion of HCN2 channels opens in response to the basal cAMP pool size produced by constitutively active GPCRs. Here, we employed an exogenous HEK293 expression system and voltage-clamp patch-clamp recordings to investigate basal HCN2 channel activity in the presence of two GPCRs with diverse basal activities in a single compartment. We utilized the β2-adrenoceptor (β2AR) together with odorant receptors (ORs), as both GPCR families are known to show strong basal activity. Consequently, β2AR alone strongly enhanced the activity of HCN2 channels, and co-expression of ORs further diversified the HCN2 channel activity, which was totally abolished by an adenylate cyclase inhibitor. Thus, we conclude that the dual expression of constitutively active GPCRs establishes the diverse range of the basal cAMP pool size in resting cells through mutual additive or suppressive interactions, even in the absence of external stimulation.

60 APPLIED LIFE SCIENCES↗

Plasma Interactions with High Voltage Solar Arrays for a Direct Drive Hall Effect Thruster System

The Environmental Effects Group of NASA s Marshall Space Flight Center (MSFC) is conducting research into the effects of plasma interaction with high voltage solar arrays. These high voltage solar arrays are being developed for a direct drive Hall Effect Thruster propulsion system. A direct drive system configuration will reduce power system mass by eliminating a conventional power-processing unit. The Environmental Effects Group has configured two large vacuum chambers to test different high-voltage array concepts in a plasma environment. Three types of solar arrays have so far been tested, an International Space Station (ISS) planar array, a Tecstar planar array, and a Tecstar solar concentrator array. The plasma environment was generated using a hollow cathode plasma source, which yielded densities between 10(exp 6) - 10(exp 7) per cubic centimeter and electron temperatures of 0.5-1 eV. Each array was positioned in this plasma and biased in the -500 to + 500 volt range. The current collection was monitored continuously. In addition, the characteristics of arcing, snap over, and other features, were recorded. Analysis of the array performance indicates a time dependence associated with the current collection as well as a tendency for "conditioning" over a large number of runs. Mitigation strategies, to reduce parasitic current collection, as well as arcing, include changing cover-glass geometry and layout as well as shielding the solar cell edges. High voltage performance data for each of the solar array types tested will be presented. In addition, data will be provided to indicate the effectiveness of the mitigation techniques.

Schneider, T.↗

Voltage Probability Density Function Shaping Control Strategy Considering Grid Operational Uncertainties

It is well-known that power systems operation always affected by various uncertainties which make the bus voltage a random process that can be characterized by its probability density function (PDF) at any time instant. In this context, this paper presents a novel PDF-based voltage control framework for power systems. By modeling voltage as a stochastic process, we formulate a stochastic differential equationthat captures grid uncertainties. The associated Fokker-Planck-Kolmogorov equation is derived to describe the evolution of the voltage PDF, which enables the formulation of a PDF-shaping control strategy. To simplify the PDF control formulation, a B-spline neural network is introduced for real-time estimation and regulation of the voltage distribution. The proposed PDF control law updates voltage references for energy storage systems and synchronous generators using real-time PDF measurements and feedback signals. The proposed method is validated on a modified Kundur’s two-area system. Simulation results demonstrate that the controller can significantly improve the voltage stability under stochastic conditions, highlighting its effectiveness in modern inverter-rich grids.

Gui, Yonghao [ORNL] (ORCID:0000000250435534)↗

Models and Methods for Assessing the Value of HVDC and MVDC Technologies in Mondern Power Grids

Evolution of today’s predominantly alternating current (ac) transmission grid in to mixed ac transmission – high-voltage direct current (HVdc) systems is expected with the decreasing costs of and advancements in power electronics technologies. The recent technological advancements include the development of more efficient and compact voltage source converters (VSCs) that can provide fast response. Because of their controllability and fast response, HVdc systems provide the ability to enhance reliability of the ac transmission grid through frequency support, voltage control, and congestion relief. The HVdc systems can also provide other ancillary services to enhance the economics and reliability of the ac transmission grids, and to optimize their performance. The tools, models, and methods developed to evaluate their benefits will be key enablers to understanding the value proposition introduced by the fast-acting HVdc systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of power electronics for TVC and EMA systems

The Component Development Division of the Propulsion Laboratory at Marshall Space Flight Center (MSFC) is currently developing a class of electromechanical actuators (EMA's) for use in space transportation applications such as thrust vector control (TVC) and propellant control valves (PCV). These high power servomechanisms will require rugged, reliable, and compact power electronic modules capable of modulating several hundred amperes of current at up to 270 volts. MSFC has selected the brushless dc motor for implementation in EMA's. A previous project performed by Auburn University examined the use of the resonant dc link (RDCL) inverter, pulse density modulation (PDM), and mos-controlled thyristors (MCT's) for speed control of a brushless dc motor. The speed of the brushless dc motor is proportional to the applied stator voltage. In a PDM system, the control system determines the number of resonant voltage pulses which must be applied to the stator to achieve a desired speed. The addition of a waveshaping circuit to the front end of a standard three-phase inverter yields a RDCL inverter; the resonant voltage pulses are produced through the action of this wave shaping circuit and the inverter. This project has focused on the implementation of a system which permits zero-voltage switching with the bus voltage clamped at the input voltage level. In the same manner as the RDCL inverter, the inverter selected for this implementation is a combination of waveshaping circuit and a standard three-phase inverter. In addition, this inverter allows a pulse-width modulated (PWM)-like control scheme instead of a PDM scheme. The operation of waveshaping circuit will be described through analysis and waveforms. Design relationships will also be presented.

Nelms, R. Mark↗

The Redox flow system for solar photovoltaic energy storage

A new method of storage was applied to a solar photovoltaic system. The storage method is a redox flow system which utilizes the oxidation-reduction capability of two soluble electrochemical redox couples for its storage capacity. The particular variant described separates the charging and discharging function of the system such that the electrochemical couples are simultaneously charged and discharged in separate parts of the system. The solar array had 12 solar cells; wired in order to give a range of voltages and currents. The system stored the solar energy so that a load could be run continually day and night. The main advantages of the redox system are that it can accept a charge in the low voltage range and produce a relatively constant output regardless of solar activity.

Odonnell, P.↗