Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Integrated Energy Systems Program Management Plan

In 2012, the U.S. Department of Energy (DOE) Office of Nuclear Energy (NE) initiated the Nuclear Energy Enabling Technology Program, which includes the Crosscutting Technology Development (CTD) portfolio of subprograms, to conduct research, development, and demonstration (RD&D) to support existing, new and advanced reactor designs and fuel cycle technologies. This program plan describes the Integrated Energy Systems (IES) Program, an element of the CTD portfolio since 2016 that seeks to improve the economic competitiveness, efficiency and environmental performance of nuclear energy systems by expanding their potential application space beyond electricity and optimizing their utilization in the context of the larger U.S. electric and non-electric energy system.

08 HYDROGEN↗

An integrated knowledge system for the Space Shuttle hazardous gas detection system

A computer-based integrated Knowledge-Based System, the Intelligent Hypertext Manual (IHM), was developed for the Space Shuttle Hazardous Gas Detection System (HGDS) at NASA Marshall Space Flight Center (MSFC). The IHM stores HGDS related knowledge and presents it in an interactive and intuitive manner. This manual is a combination of hypertext and an expert system which store experts' knowledge and experience in hazardous gas detection and analysis. The IHM's purpose is to provide HGDS personnel with the capabilities of: locating applicable documentation related to procedures, constraints, and previous fault histories; assisting in the training of personnel; enhancing the interpretation of real time data; and recognizing and identifying possible faults in the Space Shuttle sub-systems related to hazardous gas detection.

Lo, Ching F.↗

Renewable Energy Technologies and Integrated Energy Systems

As renewable energy deployment expands, its integration into broader energy systems becomes an opportunity for providing clean energy across multiple sectors. This presentation will review statistics about the growth of renewable energy and potential future trends, with an additional focus technologies important to Colorado. It will also present options for integration with other low emissions technologies, such as nuclear energy and storage, and how together they could create an integrated energy system for multiple sectors. The presentation will also include an introduction to the mission and research of the National Renewable Energy Laboratory (NREL) and the Joint Institute for Strategic Energy Analysis (JISEA).

ENERGY PLANNING, POLICY, AND ECONOMY,ENVIRONMENTAL↗

DMS Advanced Applications for Accommodating High Penetrations of DERs and Microgrids: Preprint

Efficient and effective management of the electrical distribution system requires an integrated system approach for Distribution Management Systems (DMS), Distributed Energy Resources (DERs), Distributed Energy Resources Management System (DERMS), and microgrids to work in harmony. This paper highlights some of the outcomes from a U.S. Department of Energy (DOE), Office of Electricity (OE) project, including 1) Architecture of these integrated systems, and 2) Expanded functions of two example DMS applications, Volt-VAR optimization (VVO) and Fault Location, Isolation and Service Restoration (FLISR), to accommodate DER. For these two example applications, the relevant DER Group Functions necessary to support communication between DMS and Microgrid Controller (MC) in grid-tied mode are identified.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Understanding Impacts of Data Integrity Attacks on Transactive Control Systems

With the rapid growth of internet-connected smart devices capable of exchanging energy price information and adaptively controlling energy consumption of connected loads, the role of transactive control is expected to become more prominent in the modern grid. Transactive control systems integrate the wholesale and retail energy markets, and enable active participation of end users, thereby playing a key role in managing the rising number of distributed assets in the smart grid. The use of internet for the communication of data between the controllers at the building, distribution, and transmission levels makes the system susceptible to cyber-attacks. A skilled adversary can potentially manipulate the exchanged data with the intention of inflicting damage to the system. In this paper, four categories of metrics are put forth for evaluating the performance of the system when under data integrity attacks. A model for scaling-based data integrity attack has been described, and co-simulations have been performed on a 240 bus WECC transmission system model with detailed modeling of distribution systems at specific buses. Our results show that scaling-based data integrity attacks can have non-trivial impacts on the operational, financial, and comfort aspects of the transactive control system.

Smart grid, transactive control system, Buildings-↗

DIASCoPE: Directly integrated acoustic system combined with pressure experiments—A new method for fast acoustic velocity measurements at high pressure

A novel experimental system to measure elastic wave velocities in samples in situ under extreme conditions of pressure and temperature in a multi-anvil apparatus has been installed at Beamline 6-BM-B of the Advanced Photon Source at Argonne National Laboratory. This system allows for measurement of acoustic velocities via ultrasonic interferometry, and makes use of the synchrotron beam to measure sample densities via X-ray diffraction and sample lengths using X-radiographic imaging. This system is fully integrated into the automated software controls of the beamline and is capable of collecting robust data on elastic wave travel times in less than 1 s, which is an improvement of more than one to two orders of magnitude over existing systems. Moreover, this fast data collection time has been shown to have no effect on the obtained travel time results. This allows for more careful study of time-dependent phenomena with tighter snapshots in time of processes that would otherwise be lost or averaged out in other acoustic measurement systems.

Whitaker, Matthew L.↗

Integrated analysis system for box truss antenna mesh performance

An integrated analysis system has been developed to more efficiently design and analyze the mesh reflective surface and the mesh tie system of the box truss antenna. Six integrated computer programs using nonlinear finite-element, surface topography and interpolation, and RF aperture integration techniques, analyze the effects of manufacturing errors, mesh pillowing, and operating environment on antenna performance. The level of rigor of analysis can be varied, providing the possibility of a lower cost preliminary study on various designs using a minimum number of reduced box section models. By including the random and systematic errors with the aperture integration of minimum rms reflector surface roughness, the RF Performance Solver determines the far-field pattern, including the beam efficiency, and thus the antenna performance of the mesh reflector antenna.

Bachtell, E. E.↗

Xcel Energy – LBNL ‘Beyond Widgets’ Project. Workstation Specific Lighting with Daylight Dimming Controls System Program Manual

This program manual was developed through a U.S. Department of Energy project to develop streamlined utility program approaches to the deployment of integrated systems in commercial offices. Integrated systems present deep opportunities for energy savings, however by nature these systems have additional levels of complexity and effort required for their design and energy savings assessment, which create barriers for utility incentive programs to develop streamlined cost effective incentive programs to capture these savings. This project worked with Xcel Energy in Colorado and Minnesota to select an integrated system and develop a streamlined approach to its deployment for small and large commercial offices. Xcel Energy worked with LBNL to select a workstation specific lighting system with daylight dimming controls, applied as a retrofit in commercial office spaces. Previous studies indicated a potential lighting annual energy savings of 28-63%, with an average of 47% for this system type, due to reduced fixture LPD and controls only, not including a full fixture replacement from a condition such as T8 to LED. Xcel also had a desire to incorporate this fixture replacement in their integrated system package, and as a result annual energy lighting savings are expected to be higher. FLEXLAB testing of the system for 500 lux minimum output conditions translated into a 94% annual energy savings for this system. Market analysis was developed for large and medium commercial office buildings in Xcel’s Minnesota and Colorado markets showing a potential for 48-295 and 120-672 GWh of energy savings potential for Colorado and Minnesota respectively. Total Resource Costs (TRC) vary by location and technology package used (enterprise versus non-enterprise lighting controls system), and vary from 0.29 to 1.27 and 0.06 and 0.44 for a Retrofit case, and 0.20 to 1.63 and 0.07 to 0.57 for a Replace on Burnout strategy for Colorado and Minnesota respectively. These results indicate good potential for demonstrating a strong technical and economic case for deployment of this system type in Xcel’s Colorado territory, while deployment in the Minnesota market may be advisable as well as part of a portfolio of programs, or as an effort to help shift the market into integrated systems deployment in general. It should be noted that the cost of avoided energy in both markets is significantly low ($0.07/kWh for Minnesota, $0.08/kWh for Colorado), and these TRC values would not be representative of deployment potential in other markets with higher utility rates. In addition, installation costs used for these systems may decrease with time, further enhancing their return on investment. Overall, workstation specific lighting systems with daylight dimming controls present a very strong potential for cost effective lighting energy savings, as demonstrated by the FLEXLAB test results and previous case studies. Further energy savings may be realized from the use of fixture-specific occupancy sensors as well, although this approach was not considered in this study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Study of component technologies for fuel cell on-site integrated energy systems

Heating, ventilation and air conditioning equipment are integrated with three types of fuel cells. System design and computer simulations are developed to utilize the thermal energy discharge of the fuel in the most cost effective manner. The fuel provides all of the electric needs and a loss of load probability analysis is used to ensure adequate power plant reliability. Equipment cost is estimated for each of the systems analyzed. A levelized annual cost reflecting owning and operating costs including the cost of money was used to select the most promising integrated system configurations. Cash flows are presented for the most promising 16 systems. Several systems for the 96 unit apartment complex (a retail store was also studied) were cost competitive with both gas and electric based conventional systems. Thermal storage is shown to be beneficial and the optimum absorption chiller sizing (waste heat recovery) in connection with electric chillers are developed. Battery storage was analyzed since the system is not electric grid connected. Advanced absorption chillers were analyzed as well. Recommendations covering financing, technical development, and policy issues are given to accelerate the commercialization of the fuel cell for on-site power generation in buildings.

Lee, W. D.↗

Applications of integrated design/analysis systems in aerospace structural design

Integrated structural analysis and design systems and structural optimization procedures are being used in a production environment. Successful use of these systems requires experienced personnel. Interactive computer graphics can and will play a significant role in the analysis, optimization, design and manufacturing areas. Practical structural optimization procedures are tools that must be made available to the team. Much work still needs to be done to tie finite-element modeling to actual design details which are being tracked on systems such as CADAM or CATIA. More work needs to be done to automate the detailed design and analysis process. More emphasis should be placed on the real design problems.

Mason, Philip↗

The integrated sounding system: Description and preliminary observations from TOGA COARE

An Integrated Sounding System (ISS) that combines state-of-the-art remote and in situ sensors into a single transportable facility has been developed jointly by the National Center for Atmospheric Research (NCAR) and the Aeronomy Laboratory of the National Oceanic and Atmospheric Administration (NOAA/AL). The instrumentation for each ISS includes a 915-MHz wind profiler, a Radio Acoustic Sounding System (RASS), an Omega-based NAVAID sounding system, and an enhanced surface meteorological station. The general philosophy behind the ISS is that the integration of various measurement systems overcomes each system's respective limitations while taking advantage of its positive attributes. The individual observing systems within the ISS provide high-level data products to a central workstation that manages and integrates these measurements. The ISS software package performs a wide range of functions: real-time data acquisition, database support, and graphical displays; data archival and communications; and operational and posttime analysis. The first deployment of the ISS consists of six sites in the western tropical Pacific--four land-based deployments and two ship-based deployments. The sites serve the Coupled Ocean-Atmosphere Response Experiment (COARE) of the Tropical Ocean and Global Atmosphere (TOGA) program and TOGA's enhanced atmospheric monitoring effort. Examples of ISS data taken during this deployment are shown in order to demonstrate the capabilities of this new sounding system and to demonstrate the performance of these in situ and remote sensing instruments in a moist tropical environment. In particular, a strong convective outflow with a pronounced impact of the atmospheric boundary layer and heat fluxes from the ocean surface was examined with a shipboard ISS. If these strong outflows commonly occur, they may prove to be an important component of the surface energy budget of the western tropical Pacific.

Parsons, David↗

Propulsion system structural integration and engine integrity; Proceedings of the Symposium, U.S. Naval Postgraduate School, Monterey, Calif., September 3-6, 1974

Current problems involving the structural integrity of propulsion systems, and proposed approaches to solving them, are reviewed. Areas investigated include the stall hammershock at the engine inlet, distortion-induced vibration in fan and compressor blading, modeling engine static structures with conical-shell finite elements, design and development of low-cost, self-contained bearing lubrication systems for turbine engines, and roller bearing slip and skidding damage. Individual items are announced in this issue.

Walker, W. J.↗

Data management

The following tasks were prioritized: software acquisition management plan; space station flight data system architectural study; space station user data system interface; automation of software development process; automation of software testing; distributed data base management; ADA (automated data acquisition) evaluation and transition and planning; network operating system software; fault tolerant computer validation methodology for onboard data management system; systems integration; artificial intelligence/expert systems; space station data network concept; space station standard interface protocols; space station data networks systems; integrated software development facility; and language trade studies.

Love, G.↗

Control and Non-Payload Communications (CNPC) Prototype Radio - Generation 2 Security Flight Test Report

NASA Glenn Research Center (GRC), in cooperation with Rockwell Collins, is working to develop a prototype Control and Non-Payload Communications (CNPC) radio platform as part of NASA Integrated Systems Research Program's (ISRP) Unmanned Aircraft Systems (UAS) Integration in the National Airspace System (NAS) project. A primary focus of the project is to work with the Federal Aviation Administration (FAA) and industry standards bodies to build and demonstrate a safe, secure, and efficient CNPC architecture that can be used by industry to evaluate the feasibility of deploying a system using these technologies in an operational capacity. GRC has been working in conjunction with these groups to assess threats, identify security requirements, and to develop a system of standards-based security controls that can be applied to the GRC prototype CNPC architecture as a demonstration platform. The proposed security controls were integrated into the GRC flight test system aboard our S-3B Viking surrogate aircraft and several network tests were conducted during a flight on November 15th, 2014 to determine whether the controls were working properly within the flight environment. The flight test was also the first to integrate Robust Header Compression (ROHC) as a means of reducing the additional overhead introduced by the security controls and Mobile IPv6. The effort demonstrated the complete end-to-end secure CNPC link in a relevant flight environment.

Communication Networks↗

Investigation of storage system designs and techniques for optimizing energy conservation in integrated utility systems. Volume 2: (Application of energy storage to IUS)

The applicability of energy storage devices to any energy system depends on the performance and cost characteristics of the larger basic system. A comparative assessment of energy storage alternatives for application to IUS which addresses the systems aspects of the overall installation is described. Factors considered include: (1) descriptions of the two no-storage IUS baselines utilized as yardsticks for comparison throughout the study; (2) discussions of the assessment criteria and the selection framework employed; (3) a summary of the rationale utilized in selecting water storage as the primary energy storage candidate for near term application to IUS; (4) discussion of the integration aspects of water storage systems; and (5) an assessment of IUS with water storage in alternative climates.

Source record↗