Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchrotron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Experimental Charge Density in an Oxidized Trinuclear Iron Complex using 15 K Synchrotron and 100 K Conventional Single-Crystal X-ray Diffraction

The experimental electron density distribution in a crystal consisting of the simplest conceivable trinuclear carboxylate-bridged iron-{mu}3-oxo dianion with two {alpha}-picolinium cations has been determined using both synchrotron (15 K) and conventional (100 K) X-ray diffraction data. The constituent trinuclear oxo-centered molecule consists of six 2-bridging formate groups between the iron pairs, while the axial ligand for all iron atoms is another formate group. The compound {l_brace}[Fe3O(HCOO)6(HCOO)3]2-{center_dot}H2O{center_dot}2({alpha}-CH3NC5H5)+{r_brace}, ( 1) crystallizes in the monoclinic space group P21/m with charge assisted hydrogen bonds linking the {alpha}-picolinium cations to the trinuclear groups. The chemical bonding in the weakly asymmetric Fe3O-core of 1 has been examined through the use of the quantum theory of atoms in molecules, and in combination with experimental d-orbital populations, a significant electron sharing is observed between the Fe atoms and the central oxygen. The central oxygen exhibits clear sp2 hybridization, and the iron atoms have valence shell charge concentrations in all metal-ligand bond directions. The relative bond strengths are evaluated based upon the charge density distribution and found to be in accordance with the geometrical results. Integrated group charges follow expectations from formal chemical valences.

43 PARTICLE ACCELERATORS↗

A synchrotron beamline for delivering high purity vacuum ultraviolet photons

We report on the current status and performance of the toroidal grating monochromator beamline at the Brazilian Synchrotron Light Laboratory (Laboratorio Nacional de Luz Sincrotron). This beamline provides photons in the vacuum ultraviolet and soft x-ray regions from 12 to 330 eV with three interchangeable gratings. We report on the improvement, which allows the possibility of choosing the light polarization degree from linear to almost circular. Here, we also describe the development of a new apparatus, namely, the mirror-inserted harmonic attenuator and calibrating-device with a long length (MIRHACLLE). All beamlines based on diffraction gratings suffer from the problem of high harmonics contaminations to some extent. The MIRHACLLE provides a way to efficiently suppress high harmonics from 25% to 1 ppm in a grazing incidence bending magnet beamline. Its principle of operation relays on the absorption of the high energy photons in a gas phase region. It allows negligible high harmonics contamination for photon energies ranging from 12 eV to the gas first ionization threshold, 21.6 eV, in the case of neon. We also demonstrate the possibility to use this device for energy calibration and resolution evaluation together with any experiment needing its filtering capabilities. The device is also very cost effective compared to other filters presented previously in the literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Refraction Introscopy Imaging at Synchrotron Radiation for Medical Diagnostics

The technique of X-ray refraction introscopy imaging is reviewed. Experiments on the refraction imaging carried out at the Kurchatov Synchrotron Radiation Source with mammographic phantom, small laboratory animals, and model objects are described. Contrast enhancement compared to conventional imaging is demonstrated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low temperature plasma diagnostics with tunable synchrotron vacuum ultraviolet photoionization mass spectrometry

Plasma-based technology is of great importance for a range of industrial applications. However, due to the complexity of gas-phase and surface chemical reactions, the underlying plasma chemistry is still poorly understood, leading to a growing demand for experimental setups on plasma diagnostics. In this paper, we report an apparatus that combines tunable synchrotron vacuum ultraviolet (VUV) photoionization with molecular-beam mass spectrometry for detecting ionic and neutral species formed in the processes of plasma discharge. The products including reactive intermediates such as enols can be identified unambiguously with the measurements of photoionization mass spectrometry (PIMS) and photoionization efficiency spectra. The tunable VUV PIMS has been proven as an ideal and sensitive tool for a comprehensive understanding of plasma chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal Equation of State of Copper Studied by High P-T Synchrotron X-ray Diffraction

The unit-cell volume of copper (Cu) has been measured by synchrotron x-ray at pressures and temperatures of up to 8.1 GPa and 1100 K. From pressure-volume-temperature (P-V-T) measurements, thermoelastic parameters of Cu were derived based on a modified high-T Birch-Murnaghan equation of state and a thermal pressure approach. The ambient bulk modulus derived from this work is comparable to previously reported value, whereas all other thermoelastic parameters of Cu have never been determined before. These results extend our knowledge of the fundamental thermophysical properties on Cu.

36 MATERIALS SCIENCE↗

An Efficient Referencing And Sample Positioning System To Investigate Heterogeneous Substances With Combined Microfocused Synchrotron X-ray Techniques

A referencing and sample positioning system has been developed to transfer object positions measured with an offline microscope to a synchrotron experimental station. The accuracy should be sufficient to deal with heterogeneous samples on micrometer scale. Together with an online fluorescence mapping visualisation the optical alignment helps to optimize measuring procedures for combined microfocused X-ray techniques.

39↗

Feasibility study of high-resolution coherent diffraction microscopy using synchrotron x rays focused by Kirkpatrick-Baez mirrors

High-flux coherent x rays are necessary for the improvement of the spatial resolution in coherent x-ray diffraction microscopy (CXDM). In this study, high-resolution CXDM using Kirkpatrick-Baez (KB) mirrors is proposed, and the mirrors are designed for experiments of the transmission scheme at SPring-8. Both the photon density and spatial coherence of synchrotron x rays focused by the KB mirrors are investigated by wave optical simulation. The KB mirrors can produce nearly diffraction-limited two-dimensional focusing x rays of approx1 mum in size at 8 keV. When the sample size is less than approx1 mum, the sample can be illuminated with full coherent x rays by adjusting the cross-slit size set between the source and the mirrors. From the estimated photon density at the sample position, the feasibility of CXDM with a sub-1-nm spatial resolution is suggested. The present ultraprecise figuring process enables us to fabricate mirrors for carrying out high-resolution CXDM experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchrotron photoionization mass spectrometry study of intermediates in fuel-rich 1,2-dimethoxyethane flame

Intermediates in a fuel-rich premixed laminar 1,2-dimethoxyethane (DME) flame are studied by molecular beam mass spectrometry combined with tunable synchrotron vacuum ultraviolet photoionization. About 30 intermediate species are identified in the present work, and their mole fraction profiles are evaluated. The experimental results show that the formations of intermediates, both hydrocarbons and oxygenated hydrocarbons, are closely linked to the structure of fuel, which is consistent with the previous reports. Species produced from H atom abstraction and beta scission of DME usually have much higher concentrations than others. The oxygen atoms in DME are considered to act as partitions of the primary intermediates; therefore farther reactions among these primary intermediates are difficult to occur, resulting in absence of most large intermediate species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Field-free molecular alignment for studies using x-ray pulses from a synchrotron radiation source.

A short, intense laser pulse may be employed to create a spatially aligned molecular sample that persists after the laser pulse is over. We theoretically investigate whether this impulsive molecular alignment technique may be exploited for experiments using x-ray pulses from a third-generation synchrotron radiation facility. Using a linear rigid rotor model, the alignment dynamics of model molecular systems with systematically increasing size is calculated utilizing both a quantum density matrix formalism and a classical ensemble method. For each system, the alignment dynamics obtained for a 95 ps laser is compared with that obtained for a 10 ps laser pulse. The average degree of alignment after the laser pulse, as calculated quantum mechanically, increases with the size of the molecule. This effect is quantitatively reproduced by the classical calculations. The average degree of impulsive alignment is high enough to induce a pronounced linear dichroism in resonant x-ray absorption using the intense 100 ps x-ray pulses currently available. However, for structural studies based on elastic x-ray scattering, bright x-ray pulses with a duration of 1 ps or shorter will be required in order to make full use of impulsive molecular alignment.

43 PARTICLE ACCELERATORS↗

High Resolution Far-Infrared Spectra of Thiophosgene with a Synchrotron Source: The nu{sub 2} and nu{sub 4} Bands Near 500 cm{sup -1}

Thiophosgene (Cl{sub 2}CS) is a favorite model system for studies of vibrational dynamics. But there are no previous rotationally-resolved infrared studies because the spectra are very congested due to its (relatively) large mass and multiple isotopic species. Here we report a detailed gas-phase study of the nu{sub 2} (approx504 cm{sup -1}) and nu{sub 4} (approx471 cm{sup -1}) fundamental bands, based on spectra obtained at the Canadian Light Source far-infrared beamline using synchrotron radiation and a Bruker IFS125 FT spectrometer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Test Study for Generation of Short Pulsed Synchrotron Radiation by Kicker Magnet in SPring-8 Storage Ring

A shorter pulse of synchrotron radiation is desired to measure a fast dynamic process exploration with a better resolution by material structure physics users. Among many complex schemes proposed for this purpose, we tested a simple scheme which makes use of a head-tail oscillation of a circulating electron beam with a small beam emittance. We have developed a new kicker magnet system which generated a short pulsed horizontal field of about 4.19 mT in 1.4 {mu}s pulse width with 1 Hz repetition. With this new developed kicker magnet system, we observed a bunch profile which leaned impressively between head and tail position by a visible light streak camera. Then we succeeded in achieving the shorter X-ray pulse width than the original one after a vertical slit being sliced by {approx}6 times. The observed X-ray pulse width was 7.38{+-}2.35 ps in FWHM.

43 PARTICLE ACCELERATORS↗

Instrumentation and Experimental Developments for the Beamlines at the Synchrotron SOLEIL

This paper presents an overview of the instrumentation and experiments developed for the beamlines at Synchrotron SOLEIL in France. Currently fourteen beamlines are opened to users out of the twenty six scheduled. About half of the beamlines cover the soft x-rays region using spectroscopy and imagery techniques. The second half covers the hard x-rays field studying diffraction of matter. Some sample environments carried out for beamlines, for biology, chemistry and surface sciences are described. For the soft x-rays beamlines, carbon contamination of optics is a crucial issue. Different experiments are currently under study in order to reduce or even avoid this effect. Other studies relate to the improvement of metrological methods for beamline optics, to the reduction of vibrational effects for the microbeams and development of computer control for diffractometers. The various types of instruments and experiments will be presented both with an overview of the status of the beamlines in operation and under construction.

43 PARTICLE ACCELERATORS↗

High-Speed X-ray Phase Imaging with Grating Interferometer and White Synchrotron Light

Taking advantage of the fact that an X-ray Talbot interferometer functions with X-rays of a broad energy band width, high-speed X-ray phase imaging and tomography have been achieved by using white synchrotron light. An X-ray phase tomogram could be measured with a 0.25 s exposure. Furthermore, a series of X-ray phase tomograms, in other words, a four-dimensional X-ray phase tomogram, could be reconstructed with a tomogram frame rate of 25.5 fps. This achievement advances X-ray phase imaging/tomography from a technique for static imaging to one for dynamic imaging of weakly absorbing objects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanoscale chemical imaging using synchrotron x-ray enhanced scanning tunneling microscopy

The combination of synchrotron radiation with scanning tunneling microscopy provides a promising new concept for chemical imaging of nanoscale structures. It employs detection of local x-ray absorption, which directly yields chemical, electronic, and magnetic sensitivity. The study of the tip current in the far field (800 nm tip/sample separation) shows that insulator-coated tips have to be considered in order to reduce the background from stray photoelectron. A picture of the different channels contributing to the x-ray enhanced STM process is proposed. If during electron tunneling the sample is illuminated with monochromatic x-rays, characteristic absorption will arise, and core electrons are excited, which might modulate the conventional tunnel current and facilitate chemical imaging at the nanoscale.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Numerical Algorithm to Calculate the Pressure Distribution of the TPS Front End Due to Desorption Induced by Synchrotron Radiation

The pressure distribution is an important aspect of a UHV subsystem in either a storage ring or a front end. The design of the 3-GeV, 400-mA Taiwan Photon Source (TPS) foresees outgassing induced by photons and due to a bending magnet and an insertion device. An algorithm to calculate the photon-stimulated absorption (PSD) due to highly energetic radiation from a synchrotron source is presented. Several results using undulator sources such as IU20 are also presented, and the pressure distribution is illustrated.

43 PARTICLE ACCELERATORS↗

Synchrotron Area X-ray Detectors, Present and Future

X-ray experiments are very frequently detector limited at today's storage ring synchrotron radiation (SR) sources, and will be even more so at future Energy Recovery Linac and X-ray Free Electron Laser sources. Image plate and phosphor-coupled CCD detectors that predominate at present-day sources were outgrowths of technologies initially developed for the medical and astronomical communities, respectively, with resultant limitations for SR. These limitations are enumerated. The growth of commercial silicon foundries and design tools enabling the production of large, customized integrated circuits is beginning to have a profound impact on SR detectors and is ushering in the age of 'designer detectors'. Novel area Pixel Array Detectors (PADs) are starting to appear in which each pixel has dedicated, complex circuitry capable of high speed and, in some cases, significant data processing power for specific applications. PADs now at, or near the horizon will be described. Integrated circuit methods continue to develop at a rapid pace. Implications for future x-ray detectors will be discussed.

43 PARTICLE ACCELERATORS↗

Medipix3 array high performance read-out board for synchrotron research

The Medipix3 ASIC is one of the most advanced chip that is presently available to build photon counting area detectors. The capabilities of the chip include adjacent pixels charge summing circuitry to sort out the distortion due to charge sharing, simultaneous counting and read-out that enables frames to be acquired without dead time, the colour mode of operation that enables up to eight energy bands to be acquired. In order to fully exploit the capabilities of the Medipix3 chip in synchrotron research, a high performance electronic board capable of driving large arrays of chips is necessary. We propose a parallel read-out board of Medipix3 chip arrays with a scalable architecture that allows driving the Medipix3 chip in all of its modes of operation. The board functions include the control of the chip arrays, data formatting and data compression, the management of the communications with the data storage devices, and operation in various trigger modes. In addition to this the board will have some 'intelligence' embedded. This will add some very important features to the final detector such as pattern recognition, capability of variable frame duration as a function of the photon flux, feedback to other equipment and real time calculations of data relevant to experiments such as the autocorrelation function.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗