A Fully Reversible Water Electrolyzer Cell Made Up from FeCoNi (Oxy)hydroxide Atomic Layers
Abstract not provided
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
Regardless of current market conditions and availability of conventional petroleum sources, alternatives are needed to circumvent future economic and environmental impacts from continued exploration and harvesting of conventional hydrocarbons. Diatoms and green algae (microalgae) are eukaryotic photoautotrophs that can utilize inorganic carbon (e.g., CO 2 ) as a carbon source and sunlight as an energy source, and many microalgae can store carbon and energy in the form of neutral lipids. In addition to accumulating useful precursors for biofuels and chemical feed stocks, the use of autotrophic microorganisms can further contribute to reduced CO 2 emissions through utilization of atmospheric CO 2 . Because of the inherent connection between carbon, nitrogen, and phosphorus in biological systems, macronutrient deprivation has been proven to significantly enhance lipid accumulation in different diatom and algae species. However, much work is needed to understand the link between carbon, nitrogen, and phosphorus in controlling resource allocation at different levels of biological resolution (cellular versus ecological). An improved understanding of the relationship between the effects of N, P, and micronutrient availability on carbon resource allocation (cell growth versus lipid storage) in microalgae is needed in conjunction with life cycle analysis. This mini-review will briefly discuss the current literature on the use of nutrient deprivation and other conditions to control and optimize microalgal growth in the context of cell and lipid accumulation for scale-up processes.
A modification to the setup algorithm for the multigrid preconditioner of Wilson fermions in lattice QCD is presented. A larger basis of test vectors than that used in regular multigrid is calculated by the smoother and truncated by singular value decomposition on the chiral components of the test vectors. The truncated basis is used to form the prolongation and restriction matrices of the multigrid hierarchy. This modification of the setup method is demonstrated to increase the convergence of linear solvers on an anisotropic lattice with m π ≈ 239 MeV from the Hadron Spectrum Collaboration and an isotropic lattice with m π ≈ 220 MeV from the MILC Collaboration. The lattice volume dependence of the method is also examined. Increasing the number of test vectors improves speedup up to a point, but storing these vectors becomes impossible in limited memory resources such as GPUs. To address storage cost, we implement a streaming singular value decomposition of the basis of test vectors on the chiral components and demonstrate a decrease in the number of fine level iterations by a factor of 1.7 for m q ≈ m crit
A high performance binder-free SiO x /C composite electrode was synthesized by mixing SiO x particles and Kraft lignin in a cryo-mill followed by heat treatment at 600 °C. After the heat treatment, lignin formed a conductive matrix hosting SiO x particles, ensuring electronic conductivity, connectivity, and accommodation of volume changes during lithiation/delithiation. As the result, no conventional binder or conductive agent was necessary. When electrochemically cycled, the composite electrode delivered excellent performance, maintaining ~900 mAh g -1 after 250 cycles at a rate of 200 mA g -1 , and good rate capability. The robustness of the electrode was also examined by post-cycling SEM images, where few cracks were observed. The excellent electrochemical performance can be attributed to the comparatively small volume change of SiO x -based electrodes (160%) and the flexibility of the lignin derived carbon matrix to accommodate the volume change. In conclusion, this work should stimulate further interests in using bio-renewable resources in making advanced electrochemical energy storage systems.
In the past several years, Materials Genome Initiative (MGI) efforts have produced myriad examples of computationally designed materials in the fields of energy storage, catalysis, thermoelectrics, and hydrogen storage as well as large data resources that are used to screen for potentially transformative compounds. The bottleneck in high-Throughput materials design has thus shifted to materials synthesis, which motivates our development of a methodology to automatically compile materials synthesis parameters across tens of thousands of scholarly publications using natural language processing techniques. To demonstrate our framework's capabilities, we examine the synthesis conditions for various metal oxides across more than 12 thousand manuscripts. We then apply machine learning methods to predict the critical parameters needed to synthesize titania nanotubes via hydrothermal methods and verify this result against known mechanisms. Lastly, we demonstrate the capacity for transfer learning by using machine learning models to predict synthesis outcomes on materials systems not included in the training set and thereby outperform heuristic strategies.
The corrosion kinetics of metals in the presence of polymer electrolytes—which are often used in devices for the electrochemical production of hydrogen, hydrocarbons, and alcohols—is convoluted by transport and ill-defined reactive interfaces which mask the fundamental reaction kinetics. Underpotential-deposited monolayers of Cu at Au(111) surfaces provide a structurally welldefined active site for interfacial ion transfer, with a fixed number of sites available for adsorption. Here, we investigate the adsorption behavior of Cu at Au(111) surfaces across a series of sulfate and sulfonate electrolytes, to understand how anion structure influences the kinetics of elementary interfacial ion-transfer reactions. The influence of anion structure is most significant at high adsorbate coverage, with similar adsorption isotherms and kinetics observed for all three molecular sulfates and sulfonates. In contrast, a suspended perfluorosulfonic acid ionomer reduced both the equilibrium coverage of Cu as well as the standard exchange rate at Au(111) at low coverages of Cu. These results suggest that electrocatalyst corrosion is inhibited for metal nanoparticles supported at polymer electrolytes due to changes in adsorbate coverage as well as suppressed kinetics for interfacial ion transfer.
Irrigation modulates the terrestrial water budget, especially in intensively irrigated regions such as Indian sub-continent river basins, where 35% of agricultural land has been irrigated during 2010. Here, we investigate the impact of irrigation on water budget components and land surface temperature (LST), as well as seasonal and annual trends of irrigation water demand in response to climate variability over the Indian sub-continental region. We use the Variable Infiltration Capacity (VIC) model coupled with an irrigation scheme (VIC-IRR) to represent the irrigation activities. The VIC-IRR model was calibrated and evaluated against in-situ and remote sensing observations including streamflow from India-Water Resource Information System (WRIS), Terrestrial Water Storage Change (TWSC) from Gravity Recovery and Climate Experiment (GRACE), LST from Advanced Along-Track Scanning Radiometer (AATSR), and observed gravimetric soil moisture data from India Meteorology Department (IMD). We conducted two simulations (i.e., with and without irrigation) over 18 Indian sub-continental basins at 0.25° spatial resolution from 1951 to 2012. The comparison between the two simulations indicates that as a result of irrigation, evapotranspiration (ET) increases in all the basins. We find that mean annual ET of Indus and Ganges basins increases by 47% and 12%, respectively due to irrigation. After irrigation, basin averaged total runoff (TR) was increased in the most irrigated basins (i.e., Sabarmati, Ganges, and Indus) by 4.62%, 11.87% and 7.06% in the monsoon, pre-monsoon, and post-monsoon seasons, respectively. The land surface temperature was cooled down in range of 0.2-0.65 °C in the Indian sub-continental basins especially in Ganges and Indus basins. Compare to other basins; irrigation water demand was high in Indus and Ganges basins during the post-monsoon season. Using the nonparametric Mann–Kendall trend test we find that in the pre-monsoon and monsoon seasons over the study period, irrigation demand decreased by 8.25 mm/year in 13 basins. Whereas for the post-monsoon season, irrigation water demand increased in 12 out of the 18 basins. Changes in irrigation demands are largely driven by changes in soil moisture due to decline in the summer monsoon precipitation.
We explored methane hydrate formation with sedimentation with a newly developed one-dimensional, multiphase flow, multicomponent transport numerical model. Our model couples methane hydrate formation from in situ microbial methane generation within the hydrate stability zone (HSZ), methane recycling, and microbial methane generation below the base of the hydrate stability zone (BHSZ). Both recycled methane and deeply generated methane are transported into the HSZ by buoyancy-driven free gas flow. Free gas flows through the HSZ by both the processes of capillary-dependent pore fillings and by salt exclusion during hydrate formation, with the former being the dominant mechanism. We quantitively illustrated the formation of enriched hydrate in muddy sediments above, and interconnected free gas below, the BHSZ, which are common features along the world's continental margin. In addition, we showed two ways to form concentrated methane hydrate above the BHSZ. The first mechanism is local free gas flow during methane recycling. This happens at sites with sufficient methane generation above the BHSZ. The second mechanism is deep microbial methane generation which is transported into the HSZ by free gas flow. This mechanism plays a more important role at sites with high sedimentation rates. This study provides new insights into methane hydrate formation and distribution below the seafloor. It is important for understanding the carbon cycle and carbon storage below the seafloor and for resource evaluation and exploitation.
Cost-effective energy storage is a critical enabler for the large-scale deployment of renewable electricity. Significant resources have been directed toward developing cost-effective energy storage, with research and development efforts dominated by work on lithium ion (Li-ion) battery technology. Though Li-ion batteries have many attractive qualities, it is not clear whether they can provide an affordable levelized cost of storage (LCOS) for certain applications, such as buildings. Buildings consume most of the world's electricity, and as much as 50% of their consumption goes toward meeting thermal loads. Thermal energy storage (TES) can provide a cost-effective alternative to Li-ion batteries for buildings; however, two questions remain to be answered. First, how much of total building energy storage requirements can be met via thermal storage for building loads? Second, can the LCOS for TES be favorable compared with Li-ion batteries? In this perspective, using the United States as a case study, we show that the total requirement for TES in buildings is in the range of ~1200–4500 electrical GW h, depending on the fraction of solar versus wind in the generation mix. Furthermore, we show that with at least 25% wind generation, all of the storage needed by buildings to support the grid can be met by TES. We also introduce a framework to calculate LCOS for on-site TES in buildings to enable a direct comparison with electrical storage technologies such as Li-ion batteries. This is not trivial, because the input energy type for TES (electricity) differs from the output energy type (thermal energy), and the efficiency can depend on ambient conditions. Our LCOS analysis shows that in many situations, TES can be more cost-effective for buildings than Li-ion batteries. We conclude our perspective by discussing future research and development opportunities that can significantly advance the deployment of TES for buildings to help enable a renewable electricity-dependent grid.
This review synthesizes the state of development of saline water-based reactive carbon capture, assessing how sources, processes, and products impact viability.
The ATLAS experiment at CERN's LHC stores detector and simulation data in raw and derived data formats across more than 150 Grid sites world-wide, currently in total about 200PB on disk and 250PB on tape. Data have different access characteristics due to various computational workflows, and can be accessed from different media, such as remote I/O, disk cache on hard disk drives or SSDs. Also, larger data centers provide the majority of offline storage capability via tape systems. For the High-Luminosity LHC (HL-LHC), the estimated data storage requirements are several factors bigger than the present forecast of available resources, based on a flat budget assumption. On the computing side, ATLAS Distributed Computing was very successful in the last years with high performance and high throughput computing integration and in using opportunistic computing resources for the Monte Carlo simulation. On the other hand, equivalent opportunistic storage does not exist. ATLAS started the "Data Carousel" project to increase the usage of less expensive storage, i.e. tapes or even commercial storage, so it is not limited to tape technologies exclusively. Data Carousel orchestrates data processing between workload management, data management, and storage services with the bulk data resident on offline storage. The processing is executed by staging and promptly processing a sliding window of inputs onto faster buffer storage, such that only a small percentage of input data are available at any one time. With this project, we aim to demonstrate that this is the natural way to dramatically reduce our storage cost. The first phase of the project was started in the fall of 2018 and was related to I/O tests of the sites archiving systems. Phase II now requires a tight integration of the workload and data management systems. Additionally, the Data Carousel studies the feasibility to run multiple computing workflows from tape. The project is progressing very well and the results presented in this document will be used before the LHC Run 3.
The Fermilab Tevatron collider's data-taking run ended in September 2011, yielding a dataset with rich scientific potential. The CDF and DO experiments each have nearly 9 PB of collider and simulated data stored on tape. A large computing infrastructure consisting of tape storage, disk cache, and distributed grid computing for physics analysis with the Tevatron data is present at Fermilab. The Fermilab Run II data preservation project intends to keep this analysis capability sustained through the year 2020 or beyond. To achieve this, we are implementing a system that utilizes virtualization, automated validation, and migration to new standards in both software and data storage technology as well as leveraging resources available from currently-running experiments at Fermilab. Furthermore, these efforts will provide useful lessons in ensuring long-term data access for numerous experiments throughout high-energy physics, and provide a roadmap for high-quality scientific output for years to come.
This article proposes a nonisolated dc converter-based energy router (dc-ER) and its operating strategy. Here, the intent is to integrate energy storage (ES), distributed generation (DG), local load, and dc power grid in an autonomous and more efficient way. The ES/DG power ports are coupled with each other in partial-type connections, which obtains higher voltage supply gain and direct input–output power transmission. High-voltage supply gain allows a wide solar power tracking range and the possibility of optimal battery charging/discharging. Direct input–output power transmission improves the energy conversion efficiency. In this article, the operating modes of dc-ER are first analyzed, followed by the optimal hardware design counting the DG current ripple minimization and the limitation caused by the power flow direction. Second, the mathematical model of dc-ER is deduced. The hierarchical control is then proposed to manage port energy in a flexible manner. The stability is analyzed by using impedance modeling. Finally, experimental and simulation results verify the superiorities of the proposed topology in terms of flexible operating mode transition and high-power conversion efficiency.
Today’s complex grid involves many interdependent systems. Various layers of hierarchical control and communication systems are coordinated, both spatially and temporally to achieve gird reliability. As new communication network based control system technologies are being deployed, the interconnected nature of these systems is becoming more complex. Deployment of smart grid concepts promises effective integration of renewable resources, especially if combined with energy storage. However, without a philosophical focus on resilience, a smart grid will potentially lead to higher magnitude and/or duration of disruptive events. The effectiveness of a resilient infrastructure depends upon its ability to anticipate, absorb, adapt to, and/or rapidly recover from a potentially catastrophic event. Future system operations can be enhanced with a resilient philosophy through architecting the complexity with state awareness metrics that recognize changing system conditions and provide for an agile and adaptive response. The starting point for metrics lies in first understanding the attributes of performance that will be qualified. In this paper, we will overview those attributes and describe how they will be characterized by designing a distributed agent that can be applied to the power grid.
In this paper, a day-ahead market-clearing model for smart distribution systems is proposed. Various types of distributed energy resources (DERs), such as distributed energy storage, distributed generators, microgrids, and load aggregators, can bid into the day-ahead distribution-level electricity market. Considering system Volt/VAR control, network reconfiguration, and interactions with the wholesale market, an optimization model is built to clear the day-ahead market, through which the distribution locational marginal pricing (DLMPs) for both active power and reactive power are determined. Through derivations of the Lagrangian function and sensitivity factors, DLMPs are decomposed to five components (i.e., marginal costs for active power, reactive power, congestion, voltage support, and loss), which provide price signals to motivate DERs to contribute to congestion management and voltage support. Finally, case studies demonstrate the effectiveness of the proposed method.
In isolated power systems, including microgrids, distributed assets, such as renewable energy resources (e.g. wind, solar) and energy storage, can be actively coordinated to reduce dependency on fossil fuel generation. The key challenge of such coordination arises from significant uncertainty and variability occurring at small time scales associated with increased penetration of renewables. Specifically, the problem is with ensuring economic and efficient utilization of DERs, while also meeting operational objectives such as adequate frequency performance. One possible solution is to reduce the time step at which tertiary controls are implemented and to ensure feedback and look-ahead capability are incorporated to handle variability and uncertainty. However, reducing the time step of tertiary controls necessitates investigating time-scale coupling with primary controls so as not to exacerbate system stability issues. In this paper, an optimal coordination (OC) strategy, which considers multiple time-scales, is proposed for isolated microgrid systems with a mix of DERs. This coordination strategy is based on an online moving horizon optimization approach. The effectiveness of the strategy was evaluated in terms of economics, technical performance, and computation time by varying key parameters that significantly impact performance. The illustrative example with realistic scenarios on a simulated isolated microgrid test system suggests that the proposed approach is generalizable towards designing multi-time scale optimal coordination strategies for isolated power systems.
The Transactive Energy Service System (TESS) is a platform to design, deploy, and operate transactive energy systems in electric utility retail environments. TESS provides retail market clearing mechanisms for peer-to-peer trading of behind-the-meter distributed energy resources based on ramping, capacity, and storage prices.
Increasing mean annual temperatures under climate change are expected to reduce seasonal snowpack, increase evapotranspiration (ET), and alter summer baseflow in headwater watersheds worldwide. Strong regional variability in hydrologic responses highlights the need for catchment-scale, physically based models to assess future flood risk and water availability. This study examines climate-driven changes in the hydrologic response of the Upper Feather River watershed in the Sierra Nevada Mountains, California. Four priority climate models and two representative concentration pathways (RCP4.5 and RCP8.5) are used to evaluate future hydrologic responses of the watershed. Hydrologic processes are simulated using an objectively calibrated Soil and Water Assessment Tool Plus model for a historical baseline (1986–2005) and a future period 2070–2099), driven by observed and projected precipitation and temperature. Results indicate a declining contribution of snowfall to annual precipitation, with peak snowfall and water yield shifting 1–3 months earlier. Long-term annual maximum flows are projected to increase considerably, whereas low-flow responses are mixed, with both increases and decreases projected by the end of the century. These findings highlight the need for adaptive watershed management to enhance flood protection, water storage, and drought resilience. Future water resource planning should also account for one-to-three-month shifts in peak water yield and surface runoff due to changes in snowmelt timing and a lower snowfall-to-rainfall ratio under climate change. The modeling framework and insights are transferable to other snow-dominated headwater watersheds experiencing climate-driven change.