Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “soft materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Dual energy CT for attenuation correction with PET/CT

Purpose: The authors evaluate the energy dependent noise and bias properties of monoenergetic images synthesized from dual-energy CT (DECT) acquisitions. These monoenergetic images can be used to estimate attenuation coefficients at energies suitable for positron emission tomography (PET) and single-photon emission computed tomography (SPECT) imaging. This is becoming more relevant with the increased use of quantitative imaging by PET/CT and SPECT/CT scanners. There are, however, potential variations in the noise and bias of synthesized monoenergetic images as a function of energy. Methods: The authors used analytic approximations and simulations to estimate the noise and bias of synthesized monoenergetic images of water-filled cylinders with different shapes and the NURBS-based cardiac-torso (NCAT) phantom from 40 to 520 keV, the range of SPECT and PET energies. The dual-kVp spectra were based on the GE Lightspeed VCT scanner at 80 and 140 kVp with added filtration of 0.5 mm Cu. The authors evaluated strategies of noise suppression with sinogram smoothing and dose minimization with reduction of tube currents at the two kVp settings. The authors compared the impact of DECT-based attenuation correction with single-kVp CT-based attenuation correction on PET quantitation for the NCAT phantom for soft tissue and high-Z materials of bone and iodine contrast enhancement. Results: Both analytic calculations and simulations displayed the expected minimum noise value for a synthesized monoenergetic image at an energy between the mean energies of the two spectra. In addition the authors found that the normalized coefficient of variation in the synthesized attenuation map increased with energy but reached a plateau near 160 keV, and then remained constant with increasing energy up to 511 keV and beyond. The bias was minimal, as the linear attenuation coefficients of the synthesized monoenergetic images were within 2.4% of the known true values across the entire energy range. Compared with no sinogram smoothing, sinogram smoothing can dramatically reduce noise in the DECT-derived attenuation map. Through appropriate selection of tube currents for high and low kVp scans, DECT can deliver roughly the same amount of radiation dose as that of a single kVp CT scan, but could be used for PET attenuation correction with reduced bias in contrast agent regions by a factor of ∼2.6 and slightly reduced RMSE for the total image. Conclusions: When DECT is used for attenuation correction at higher energies, there is a noise amplification that is dependent on the energy of the synthesized monoenergetic image of linear attenuation coefficients. Sinogram smoothing reduces the noise amplification in DECT-derived attenuation maps without increasing bias. With an appropriate selection of CT techniques, a DECT scan with the same radiation dose as a single CT scan can result in a PET image with improved quantitative accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Composition on Mechanical Properties and Conductivity of the Dual-Ion Conductor Na 1+ x Mn x /2 Zr 2– x /2 (PO 4 ) 3 for Solid-State Batteries

Here we report the dependence of mechanical properties and ionic conductivity of the Na 1+ x Mn x /2 Zr 2– x /2 (PO 4 ) 3 (designated as NMZP) ionic conductor on its composition (with x = 0.5, 1.0, 1.5, and 2.0). Local mechanics was studied by instrumented nanoindentation, and the properties of interest included the elastic modulus, hardness, and fracture toughness. Overall, the material becomes more compliant and soft with the increase in the Na content. The elastic modulus reduces from 120 to 80 GPa, and nanoindentation hardness reduces from 7.8 to 4.2 GPa when x changes from 0.5 to 2.0. The relationship with fracture toughness ( K C ) is highly nonlinear: fracture toughness first decreases and then increases with the increase in the sodium content, reaching a maximum value of 0.89 MPa × m 1/2 at x = 2.0. Such a relationship was found to correlate with the formation of a glassy phase in NMZP at intermediate Na concentration. The maximum ionic conductivity coincides with the maximum fracture toughness in this material.

25 ENERGY STORAGE↗

Small scale H I structure and the soft X-ray background

The observed anticorrelation between diffuse soft X-ray flux and H I column density has been explained as absorption of soft X-rays produced in a hot galactic halo, assuming that the neutral interstellar material is sufficiently clumped to reduce the soft X-ray absorption cross section by a factor of two to three. A 21 cm emission line study of H I column density variations at intermediate and high galactic latitudes to 10' spatial resolution has been done. The results confirm conclusions from preliminary work at coarser resolution, and in combination with other data appear to rule out the hypothesis that clumping of neutral interstellar matter on any angular scale significantly reduces X-ray absorption cross sections in the 0.13 - 0.28 keV energy range. It is concluded therefore that the observed anticorrelation is not primarily a consequence of absorption of soft X-rays produced in a hot galactic halo.

Jahoda, K.↗

Small-scale H I structure and the soft X-ray background

The observed anticorrelation between diffuse soft X-ray flux and H I column density has been explained as absorption of soft X-rays produced in a hot Galactic halo, assuming that the neutral interstellar material is sufficiently clumped to reduce the soft X-ray absorption cross section by a factor of two to three. A 21-cm emission-line study of H I column density variations at intermediate and high Galactic latitudes is extended to 10 arcmin spatial resolution. The results confirm conclusions from preliminary work at coarser resolution, and, in combination with other data, appear to rule out, on any angular scale, the hypothesis that clumping of neutral interstellar matter significantly reduces X-ray absorption cross sections in the 0.13-0.28 keV energy range. It is concluded therefore that the observed anticorrelation is not primarily a consequence of absorption of soft X-rays produced in a hot Galactic halo.

Jahoda, Keith↗

Orbital transfer rocket engine technology program: Soft wear ring seal technology

Liquid oxygen (LOX) compatibility tests, including autogenous ignition, promoted ignition, LOX impact tests, and friction and wear tests on different PV products were conducted for several polymer materials as verification for the implementation of soft wear ring seals in advanced rocket engine turbopumps. Thermoplastics, polyimide based materials, and polyimide-imide base materials were compared for oxygen compatibility, specific wear coefficient, wear debris production, and heat dissipation mechanisms. A thermal model was generated that simulated the frictional heating input and calculated the surface temperature and temperature distribution within the seal. The predictions were compared against measured values. Heat loads in the model were varied to better match the test data and determine the difference between the measured and the calculated coefficients of friction.

Lariviere, Brian W.↗

Anomalous Conductivity in the Rutile Structure Driven by Local Disorder

Many rutile-type materials are characterized by a softness in shear with pressure which is coupled to a Raman-active librational motion. Combining direct studies of anion positions in SnO 2 with measurements of its electronic properties, we find a correlation between O sublattice disorder between 5 and 10 GPa and an anomalous decrease up to 4 orders of magnitude in electrical resistance. Hypotheses into the atomistic nature of the phenomenon are evaluated via ab initio calculations guided by extended X-ray absorption fine structure spectroscopy analysis, and the most likely mechanism is found to be the displacement of single anions resulting from the pressure-induced softening of the librational mode. Here, on the basis of this mechanism, we propose that the same behavior should feature across all materials exhibiting a rutile → CaCl 2 phase transition and that conductivity in other rutile-type materials could be facilitated at ambient pressure by appropriate design of devices to enhance defects of this nature.

36 MATERIALS SCIENCE↗

Alignment switching in 3D-printed smectic liquid crystal elastomers

Extrusion-based additive manufacturing has emerged as a powerful platform for designing shape-morphing materials through controlled orientation. However, existing approaches primarily rely on a single mode of flow-induced alignment, limiting orientation programmability. Herein, we present a direct-ink-writing approach for smectic liquid crystal elastics that exploits two distinct alignment modes within a single ink. The smectic ink exhibits shear- and temperature-dependent orientation switching, enabling molecular alignment either perpendicular or parallel to the print direction. Combined rheological, X-ray, and molecular dynamics analyses reveal that this alignment inversion arises from the preservation or collapse of smectic layers under flow. This reversible switching encodes both contractile and elongational actuation within individual filaments, greatly expanding the design freedom of printed liquid crystal elastomers. We demonstrate 2D and 3D structures with diverse programmed shape transformations, highlighting the potential of this platform for adaptive soft actuators and architected functional materials.

Lee, Jin Hyeong [Pusan National University, Busan,↗

Development of chemometric models to classify solid-state U materials by micro-Raman spectroscopy

Discerning uranium (U) particles found in environmental sampling is of interest for monitoring the peaceful use of nuclear material. In this study, a soft independent modeling of class analogy (SIMCA) library was successfully developed for the classification of a four-class system consisting of α-U 3 O 8 , UO 2 , UO 2 (NO 3 ) 2 ·6H 2 O (UNH), and UO 2 O 2 ·4H 2 O (studtite) by Raman spectroscopy in the presence of matrix particulates and additional outliers. Spectral variability between numerous particles of each type revealed appreciable differences as a function of particle size with respect to hydration state and potential oxide phase within each class. Interclass variability was accounted for using both unsupervised and supervised chemometric models. The supervised SIMCA model displayed reasonable sensitivity for each U class and a high degree of specificity by returning whether a spectrum belonged to one class or not. This work demonstrates how Raman spectral features and chemometrics can be used to distinguish U materials from one another and from matrix materials such as flint clay. Combining the outlined chemometric approach with Raman mapping sequences could provide a rapid, nondestructive technique to characterize the chemical composition of a diverse collection of U compounds amid background samples for environmental sampling, nuclear forensics, and industrial applications.

Actinide↗

Creation of hollow silica-fiberglass soft ceramics for thermal insulation

Hollow-structured materials show promise in thermal insulation because the shells encapsulating gaseous voids can interrupt heat transport pathways. Here, in this study, we present two low-cost routes to fabricate hollow silica nanoshells, via gas-phase and liquid-phase methods. The gas-phase synthesis method generates hollow shells by a droplet surface precipitation mechanism in a flame aerosol reactor. The liquid-phase synthesis route forms hollow shells by removal of a carbon template, which is produced by hydrothermal reaction of glucose. Both approaches (gas- and liquid-phase) provide hollow silica with amorphous structure, low thermal conductivity (0.023 and 0.026 W m –1 K –1 ), small particle size (442 and 383 nm), thin shell (35 and 36 nm), and low density (0.015 and 0.033 g cm –3 ). We employed high shear mechanical mixing to fabricate hollow silica-fiberglass composite ceramics. The resulting three-dimensional network provides the ceramics with robust mechanical elasticity and fire-retardancy while maintaining low thermal conductivity, dramatically outperforming an analogous material using commercial silica gel in place of the hollow nanoshells. Our findings provide two practical routes to synthesize hollow silica, either of which can be used to manufacture a class of hollow shell-fiber nanocomposite soft ceramics for energy-saving applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoporous-carbon as a potential host material for reversible Mg ion intercalation

Here, we study nanoporous-carbon (NPC) grown via pulsed laser deposition (PLD) as an electrically conductive anode host material for Mg 2+ intercalation. NPC has high surface area, and an open, accessible pore structure tunable via mass density that can improve diffusion. We fabricate 2032 coin cells using NPC coated stainless-steel disk anodes, metallic Mg cathodes, and a Grignard-based electrolyte. NPC mass density is controlled during growth, ranging from 0.06–1.3 g/cm 3 . The specific surface area of NPC increases linearly from 1,000 to 1,700 m 2 /g as mass density decreases from 1.3 to 0.26 g/cm 3 , however, the surface area falls off dramatically at lower mass densities, implying a lack of mechanical integrity in such nanostructures. These structural characterizations correlate directly with coin cell electrochemical measurements. In particular, cyclic voltammetry (CV) scans for NPC with density ~0.5 g/cm 3 and BET surface area ~1500 m 2 /g infer the possibility of reversible Mg-ion intercalation. Higher density NPC yields capacitive behavior, most likely resulting from the smaller interplanar spacings between graphene sheet fragments and tighter domain boundaries; lower density NPC results in asymmetrical CV scans, consistent with the likely structural degradation resulting from mass transport through soft, low-density carbon materials.

30 DIRECT ENERGY CONVERSION↗

Elastomeric Sensing of Pressure with Liquid Metal and Wireless Inductive Coupling

This project describes resistance-based soft sensors filled with liquid metal, which permit measurements of large strains (0 percent to 110 percent), associated with small forces of less than 30 Newtons. This work also demonstrates a methodology for wireless transfer of these strain measurements without connected electrodes. These sensors allow intermittent detection of pressure on soft membranes with low force. Adapting these sensors for passive wireless pressure sensing will eliminate the need for embedded batteries, and will allow the sensors to transmit pressure data through non-conductive materials including glass and acrylic. The absence of batteries allows us to embed these sensors into materials for long-term use because the sensors only use passive analog circuit elements. We found the oxidation of the liquid metal (eutectic gallium indium) plays a role in the repeatability of the soft sensors. We investigated how the oxidation layer affected the behavior of the sensor by encapsulating materials (silicone, fluorosilicone, and PVC) with varied permeabilities to oxygen. We measured the effects of mechanical loading on the oxidation layer and the effects of wireless inductive coupling on the oxidation layer. We concluded our research by investigating the effects of embedding self-resonant circuits into polydimethylsiloxane (PDMS). Efforts to design engineered systems with soft materials are a growing field with progress in soft robotics, epidermal electronics, and wearable electronics. In the field of soft robotics, PDMS-based grippers are capable of picking up delicate objects because their form-fitting properties allow them to conform to the shape of objects more easily than conventional robotic grippers. Epidermal devices also use PDMS as a substrate to hold electronic components such as radios, sensors, and power supply circuits. Additionally, PDMS-based soft sensors can monitor human motion with liquid metal embedded within micro-channels. Passive wireless sensors have applications in structural health monitoring and medical health monitoring. Doctors can take wireless blood pressure measurements inside arteries to monitor the progression of heart disease. Glaucoma patients can use this technology to monitor the pressure in their eyes to track the progression of the disease.

Dick, Jacob↗

Effectiveness and Morbidity Associated With Reirradiation in Conservative Salvage Management of Recurrent Soft-Tissue Sarcoma

Purpose: The management of isolated local recurrence of soft-tissue sarcoma is therapeutically complex, and functional conservative management is preferable to radical or amputative salvage surgery. This study reviews University of Florida experience using conservative resection and reirradiation to manage isolated local recurrences of soft-tissue sarcoma. Methods and Materials: Between 1976 and 2005, a total of 14 patients who underwent primary conservative resection and irradiation developed isolated local recurrence and were managed with salvage conservative resection and reirradiation. Of the patients treated, 3 had tumors of the distal extremity, 8 had tumors of the proximal extremity, and 3 had tumors of the trunk. At the time of recurrence, 64% of tumors were greater than 5 cm and 79% were high grade. In combination with gross total resection, 13 of 14 patients received external beam radiotherapy with or without brachytherapy, and 1 patient was treated with brachytherapy alone. Two patients received chemotherapy. Results: The median follow-up was 30 months, and no living patients were lost during follow-up. From retreatment, the 5-year actuarial overall survival, cause-specific survival, and local control rates were 40%, 40%, and 18% respectively. There was a 50% incidence of serious complication requiring either reoperation or leading to permanent functional impairment. Of the 14 patients, only 1 has remained disease free and without significant complications. No treatment factors, including achieving wide surgical margins or delivering higher radiation dosages, seemed to confer an advantage in local control. Conclusions: Salvage therapy for management of locally recurrent soft-tissue sarcoma is challenging, and the effects of reoperation and reirradiation can be severe.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interaction of soft x-ray laser pulse radiation with aluminum surface: Nano-meter size surface modification

Interaction of soft x-ray laser radiation with material and caused modification of the exposed surface has both physical and practical interests. We irradiated the focusing soft x-ray laser (SXRL) pulses having a wavelength of 13.9 nm and the duration of 7 ps to aluminum (Al) surface. After the SXRL irradiation process, the irradiated Al surface was observed with a scanning electron microscope. The surface modifications caused by SXRL single pulse exposure were clearly seen. In addition, it was found that the conical structures having around 100 nm in diameters were formed in the shallow features. The nano-meter size modified structures at Al surface induced by SXRL pulse is interesting as the newly surface structure. Hence, the SXRL beam would be a candidate for a tool of micromachining. We also provide a thermomechanical modeling of SXRL interaction with Al briefly to explain the surface modification.

36 MATERIALS SCIENCE↗

Light propagation in stratified media with soft interfaces

The propagation of light through materials in which the density of charge carriers varies smoothly on a scale smaller than or comparable to the wavelength requires a description that goes beyond the commonly used Fresnel equations. We propose a method to solve Maxwell’s equations in such a way that any linear response theory for the bulk material can be combined with a given smooth density profile for the (free or bound) charge carriers. This method is implemented for linearly polarized monochromatic light impinging on inhomogeneous multilayer systems, leading to a fast algorithm that yields reflectance and transmittance for such systems. We apply our algorithm to investigate the difference in optical response between smooth interfaces and abrupt interfaces in stratified systems where the materials can have complex bulk permittivities, and find that the smoothening of the interface on a wavelength scale significantly reduces reflection in favor of absorption. This result is of importance to current experiments that aim to detect metallic hydrogen and deuterium films using their optical response. Furthermore, our results show that for a correct interpretation of these experiments it is important to consider the smoothness of the density profile of the metallic layer. Also, for nonabsorbing layers, a smooth, rather than abrupt transition, can have an important impact on the design of optical filters.

08 HYDROGEN↗

Cost-Effectiveness Analysis of Intensity Modulated Radiation Therapy Versus 3-Dimensional Conformal Radiation Therapy for Preoperative Treatment of Extremity Soft Tissue Sarcomas

Purpose: Create a cost-effectiveness model comparing preoperative intensity modulated radiation therapy (IMRT) versus 3-dimensional conformal radiation therapy (3DCRT) for extremity soft tissue sarcomas. Methods and Materials: Input parameters included 5-year local recurrence rates, rates of acute wound adverse events, and chronic toxicities (edema, fracture, joint stiffness, and fibrosis). Health-state utilities were used to calculate quality-adjusted life years (QALYs). Overall treatment costs per QALY or incremental cost-effectiveness ratio (ICER) were calculated. Roll-back analysis was performed using average costs and utilities to determine the baseline preferred radiation technique. One-way, 2-way, and probabilistic sensitivity analyses (PSA) were performed for input parameters with the largest impact on the ICER. Results: Overall treatment costs were $17,515.58 for 3DCRT compared with $22,920.51 for IMRT. The effectiveness was higher for IMRT (3.68 QALYs) than for 3DCRT (3.35 QALYs). The baseline ICER for IMRT was $16,842.75/QALY, making it the preferable treatment. The ICER was most sensitive to the probability of local recurrence, upfront radiation costs, local recurrence costs, certain utilities (no toxicity/no recurrence, grade 1 toxicity/no local recurrence, grade 4 toxicity/no local recurrence), and life expectancy. Dominance patterns emerged when the cost of 3DCRT exceeded $15,532.05 (IMRT dominates) or the life expectancy was under 1.68 years (3DCRT dominates). Furthermore, preference patterns changed based on the rate of local recurrence (threshold: 13%). The PSA results demonstrated that IMRT was the preferred cost-effective technique for 64% of trials compared with 36% for 3DCRT. Conclusions: Based on our model, IMRT is the preferred technique by lowering rates of local recurrence, severe toxicities, and improving QALYs. From a third-party payer perspective, IMRT should be a supported approach for extremity soft tissue sarcomas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The magnetic order in multiferroic DyMnO 3

We report that with flexibility in tuning their electric and magnetic properties, multiferroics can be used in information exchange and storage in ways that are very different from the present electronic materials. Here we use resonant soft X-ray scattering spectroscopy to study the F-type (0,τ,0) and C-type (0, 1–2τ, 0) diffraction peaks from sinusoidal antiferromagnetic spin order in multiferroic DyMnO 3 . By comparing the temperature dependence of ordering wave vectors τ, peak intensities I, and correlation lengths λ measured at Mn L 2 - , O K-, and Dy M 5 -edges, we show that the nearly perfect locking between the ordering wave vectors from Dy 4f states and Mn 3d orbitals manifesting the second harmonic diffraction peak implies the notable orbital involvement in the coupling between Mn and Dy spins. Our DFT calculations further suggest that the lattice response to different antiferromagnetic ground states (A-type versus E-type) is much weaker in TbMnO 3 , in agreement with previous claim that the symmetric exchange interaction can be an important factor for understanding the ferroelectricity in DyMnO 3 than in TbMnO 3 .

36 MATERIALS SCIENCE↗