Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “shielding design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Shielding requirements for manned orbiting space stations

A detailed parametric investigation of radiation shielding requirements was performed for first generation manned orbiting space stations. Two specific space station designs were studied; the results of the shielding analysis are based on the actual geometry of the vehicles, onboard equipment, and supplies. Results are presented for circular orbits ranging from 100 to 600 nautical miles and from 29° to 90° inclination. The effects of the geometry of the space stations, the use of personal shielding, and the use of particular shielding materials are discussed.

MANNED ORBITAL SPACE STATION /MOSS/↗

Lead Shielded Enclosures for CHESS-U

Shielded enclosures are critical components of radiation safety at scientific, medical, and industrial facilities around the world. As part of the Cornell High Energy Synchrotron Source Upgrade (CHESS-U), ADC has designed, fabricated, and installed highly modular shielded enclosures ("hutches" at synchrotron facilities). ADC utilized expert consultation offered by several facilities including engineers from Advanced Photon Source (APS)(1-3) and Cornell High Energy Synchrotron Source (CHESS); with each facility providing guidance to assure that the design satisfies the rigorous radiation safety requirements. In this paper, ADC will discuss the design of these hutches, particularly the modular design elements which facilitate rapid installation to minimize downtime at the synchrotron.

enclosure↗

Smaller but Fully Functional Backshell for Cable Connector

An improved design for the backshell of a connector for a shielded, multiplewire cable reduces the size of the backshell, relative to traditional designs of backshells of otherwise identical cable connectors. Notwithstanding the reduction in size, the design provides all the functionality typically demanded of such a backshell, including (1) termination of the cable shield (that is, grounding of the shield to the backshell), (2) strain relief for the cable, and (3) protection against electromagnetic interference (EMI).

Stephenson, Gregory↗

Electromagnetic fields and torque for a rotating gyroscope with a superconducting shield

In a proposed experiment, a measurement is to be made of the angular precession of a rotating superconducting gyroscope for the purpose of testing different general-relativity theories. For various reasons having to do with the design of the experiment, the superconducting shield surrounding the gyroscope is not spherically symmetric and produces a torque. There are two distinct features of the shield which lead to a torque on the gyroscope. First, its shape is a sphere intersected by a plane. If the angular momentum of the gyroscope is not parallel to the rotational symmetry axis of the shield, there is a torque which is calculated. Second, there are small holes in the spherical portion of the shield. The earth's field can penetrate through these holes and give an additional torque which is also calculated. In the actual experiment, these torques must be accurately known or made very small in order to obtain meaningful results. The present calculation is sufficiently general for application over a wide range of experimental design parameters.

Ebner, C.↗

Landsat 9 Micrometeoroid and Orbital Debris (MMOD) Mission Success Approach

Landsat 9* (L9) is the successor mission to Landsat 8 (L8) previously known as Landsat Data Continuity Mission (LDCM). Both missions are large unmanned remote sensing satellites operating in sunsynchronous polar orbits. As opposed to L8/LDCM, systems engineers for L9 incorporated Micrometeoroid/Orbital Debris (MMOD) protection for small object collisions as part of the L9’s mission success criteria. In other words, the NASA Process for Limiting Orbital Debris (NASA-STD-8719.14A) only calls for analyses of the protection of disposal-critical hardware, but L9 opted to also assess and provide small particle penetration protections for all observatory components including instruments that are not part of the spacecraft components needed for controlled reentry. Systems engineers at Goddard developed a design process to protect against MMOD during the life of Low Earth Orbit (LEO) observatories, and in particular the Landsat 9 Mission. Simply stated, this design process enhanced the effectiveness of existing Multi-Layer Insulation (MLI) to provide the needed protection. The end goal of the design process was to establish a necessary blanket areal density for a given electronics box or instrument wall thickness and a separation between the outer MLI blanket and the structure underneath. The trade space was presented as a set of design curves for different combinations of blanket density, box wall thickness, and separation distance between MLI and structure. An advantage of this process was that it is largely independent of MMOD flux data on a surface-by surface basis. Ultimately, cost savings should result from incorporating small object penetration protection early in the design cycle, rather than adding spot shielding blankets later as needed to meet an overall penetration risk standard (the more traditional approach). The approach and implementation to the L9 Observatory design will be addressed in this paper. *L9 is a joint mission being formulated, implemented, and operated by the National Aeronautics and Space Administration (NASA) and the Department of the Interior’s (DOI) United States Geological Survey (USGS).

Approach↗

MCNP6 Shielding Validation Suite: Past, Present, and Future [Slides]

MCNP6 is a general radiation transport software package used for a variety of applications including criticality and radiation detection and shielding, which are important for the design of criticality accident alarm systems. As part of MCNP6's software quality assurance, the development team produces validation suites for specific application. The MCNP6 shielding validation suite dates back to the 1990's and updated with more detailed geometry and more resolution in the tally results, and now is included as part of the automated testing. Additions to the suite are currently being proposed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fusion-Enabled Pluto Orbiter and Lander

Direct Fusion Drive (DFD) is a unique fusion engine concept based on the Princeton Field-Reversed Configuration (PFRC) fusion reactor conceived by Dr. Sam Cohen of the Princeton Plasma Physics Laboratory. DFD would enable the Pluto orbiter and lander context mission and more broadly enable true "rapid transit" to outer-planet and near interstellar space. The truly game-changing levels of thrust and power in a modestly sized package could integrate with our current launch infrastructure while radically expanding the science capability of these missions. Our Phase I was our first funded work on the DFD, with previous work at PSS occurring only under internal R&D. We established the feasibility of our Pluto mission trajectories using straight-line and planar models, including a departure spiral from Earth and insertion at Pluto. We developed our first thrust and specific impulse model using the results of the UEDGE multi-fluid code. Our specific power model was improved. During this Phase II effort, we continued our efforts to increase the fidelity of the designs for the RF, magnet, and shielding subsystems. Dedicated thrust augmentation experiments were run on the PFRC experiment, using a supersonic gas puffing valve. For the first time, we analyzed the design of a closed-loop operation mode and estimated the hardware that would be required for a dual-mode engine. In an exciting new development, we have invented a new thermophotovoltaic thermal conversion method that has the potential to have efficiencies of a Brayton or Stirling system. Our report presents details of these analyses. Our roadmap to bringing DFD to flight predicts that with sufficient support, a first flight unit could be built by 2040. We anticipate that three machine generations are required before this point: a ~1 T PFRC-3 machine hitting new plasma temperature and density levels, a ~5 T PFRC-4 machine with first demonstration of D-3He fusion, and a flight. (The current experiment, PFRC-2, is limited to about 0.1 T). In order to achieve a flight in 2035-2040, the TRL of the supporting systems must be increased in parallel, including low mass radiators, cryogenic propellant storage, and large (>100 kW) thermal conversion systems. Fortunately, many of these systems are dual-use and are required for other technologies including fission systems, so DFD would contribute to and benefit from those programs. This NIAC support and the results of our work have led to multiple follow-on contracts. We won two NASA STTRs focused on DFD subsystems, one on the RF system and one on the superconducting magnets, and our magnet STTR is now midway through a Phase II. We will be receiving a superconducting test magnet for experiments at PPPL this summer. In addition, we won an ARPA-E OPEN grant; this is the first time that OPEN has included fusion technologies, and we are part of a cohort of three alternative fusion companies now supported directly by DOE. We are very optimistic that if we are able to meet our experimental milestones in the next 12-18 months, we will be competitive for additional DOE grants to build PFRC-3.

Propulsion↗

Overview on Shielding Analyses for the VENUS Instrument at SNS

VENUS, a world‐class versatile neutron imaging instrument, is under construction and is expected to be completed and ready to start commissioning in 2023. The range of cold to epithermal neutrons at SNS will give users of VENUS access to novel imaging methods, as well as to significantly improved existing methods. The instrument is being built on beam line 10 at Spallation Neutron Source (SNS) First Target Station (FTS) facing a decoupled poisoned hydrogen moderator. Instrument design, which includes optics, Front-End components and instrument enclosure components and shape started over 10 years ago and during this time had significant changes. All changes were supported by neutronics analyses to provide adequate shielding for both Front-End and instrument enclosure.Final optics design will provide the field of view (FOV) at the detector position (where the image is formed) to be as high as 0.20 by 0.20 m. Both the beam, which contains a large fraction of high-energy neutrons, and the desire for a large footprint on the detector are challenges for shielding design and budget, because the driving cost for the instrument is the beam line and enclosure shielding. For cost reason VENUS baseline design is optimized with respect to both the instrument cave footprint and its wall thickness, and Front-End shielding is tailored along the beam. Analyses are performed with the Monte Carlo particle transport code MCNPX version 2.7.0 to make choices on materials, thicknesses and configurations of the shielding. Numerous calculations are performed to meet space and coast constrain and to satisfy instrument physics needs and to comply with radiation protection requirements.

Gallmeier, Franz X.↗

Technique for Configuring an Actively Cooled Thermal Shield in a Flight System

Broad area cooling shields are a mass-efficient alternative to conductively cooled thermal radiation shielding. The shield would actively intercept a large portion of incident thermal radiation and transport the heat away using cryogenic helium gas. The design concept consists of a conductive and conformable surface that maximizes heat transfer and formability. Broad Area Cooled (BAC) shields could potentially provide considerable mass savings for spaceflight applications by eliminating the need for a rigid thermal radiation shield for cryogen tanks. The BAC consists of a network of capillary tubes that are thermally connected to a conductive shield material. Chilled helium gas is circulated through the network and transports unwanted heat away from the cryogen tanks. The cryogenic helium gas is pumped and chilled simultaneously using a specialized pulse-tube cryocooler, which further improves the mass efficiency of the system. By reducing the thermal environment temperature from 300 to 100 K, the radiative heat load on a cryogen tank could be reduced by an order of magnitude. For a cryogenic liquid propellant scenario of oxygen and hydrogen, the boiloff of hydrogen would be significantly reduced and completely eliminated for oxygen. A major challenge in implementing this technology on large tanks is that the BAC system must be easily scalable from lab demonstrations to full-scale missions. Also, the BAC shield must be conformable to complex shapes like spheres without losing the ability to maintain constant temperature throughout. The initial design maximizes thermal conductivity between the capillary tube and the conductive radiation shielding by using thin, corrugated aluminum foil with the tube running transverse to the folds. This configuration has the added benefit of enabling the foil to stretch and contract longitudinally. This allows the BAC to conform to the complex curvature of a cryogen tank, which is key to its success. To demonstrate a BAC shield system with minimal impact to current cryogen tank designs, the shielding must be applied after the final assembly of the tank and supporting structure. One method is to pre-fabricate the shield in long strips. A spool of corrugated aluminum foil with a thermally sunk aluminum capillary running through the center could then be simply wound around the cryogen tanks and encapsulated within the multi-layer insulation (MLI) blanket. Then, on orbit, the BAC would intercept thermal radiation coming in through the MLI and transport it away from the cryogen tanks. An optimization of the design could be done to take into account mass savings from thinner MLI blankets, eliminating solid thermal shields, and ultimately, a reduction in the required cryogen tank size.

Barkfknecht, Peter↗

Detector Background at Muon Colliders

Physics goals of a Muon Collider (MC) can only be reached with appropriate design of the ring, interaction region (IR), high-field superconducting magnets, machine-detector interface (MDI) and detector. Results of the most recent realistic simulation studies are presented for a 1.5-TeV MC. It is shown that appropriately designed IR and MDI with sophisticated shielding in the detector have a potential to substantially suppress the background rates in the MC detector. The main characteristics of backgrounds are studied.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The EBIT Calorimeter Spectrometer: A New, Permanent User Facility at the LLNL EBIT

The EBIT Calorimeter Spectrometer (ECS) has recently been completed and is currently being installed at the EBIT facility at the Lawrence Livermore National Laboratory. The ECS will replace the smaller XRS/EBIT spectrometer that has been in almost continuous operation since 2000. The XRS/EBIT was based on a spare laboratory cryostat and an engineering model detector system from the Suzaku/XRS observatory. The new ECS spectrometer was built from the ground up to be a low maintenance, high performance microcalorimeter spectrometer with 4 eV resolution at 6 keV, 32 detector channels, 10 us event timing, and capable of uninterrupted acquisition sessions of over 70 hours at 50 mK. The XRSIEBIT program has been extremely successful, producing over two-dozen refereed publications on topics such as laboratory astrophysics, atomic physics, nuclear physics, and calibration of the spectrometers for the National Ignition Facility, with many more publications in preparation. The ECS spectrometer will continue this work into the future with improved spectral resolution, integration times, and ease-of-use. We designed the ECS instrument with TES detectors in mind by using the same highly successful magnetic shielding as our laboratory TES cryostats. This design will lead to a future TES instrument at the LLNL EBIT. This proposed future instrument would include a hybrid detector system with 0.8 eV resolution in the band from 0.1-1.0 keV, 2 eV from 0.1-10 keV, and 30 eV from 0.5-100 keV, with high quantum efficiency in each band. Here we discuss the legacy of the XRS/EBIT program, the performance of the new ECS spectrometer, and plans for a future TES spectrometer.

Porter, S.↗

2013 R&D 100 Award: 'SHIELD' protects NIF optics from harmful pulses

In the past, it took as long as 12 hours to manually screen 48 critical checkpoints at the National Ignition Facility (NIF) for harmful laser pulses. The screening equipment had to be moved from point to point throughout a facility the size of three football fields. Now with a new technology, called Laser SHIELD (Screening at High-throughput to Identify Energetic Laser Distortion), and with the push of a button, the screening can be done in less than one second. Proper screening of pulses is critical for the operation of high-energy lasers to ensure that the laser does not exceed safe operating conditions for optics. The energetic beams of light are so powerful that, when left uncontrolled, they can shatter the extremely valuable glass inside the laser. If a harmful pulse is found, immediate adjustments can be made in order to protect the optics for the facility. Laser SHIELD is a custom-designed high-throughput screening system built from low-cost and commercially available components found in the telecommunications industry. Its all-fiber design makes it amenable to the unique needs of high-energy laser facilities, including routing to intricate pick-off locations, immunity to electromagnetic interference and low-loss transport (up to several kilometers). The technology offers several important benefits for NIF. First, the facility is able to fire more shots in less time-an efficiency that saves the facility millions of dollars each year. Second, high-energy lasers are more flexible to wavelength changes requested by target physicists. Third, by identifying harmful pulses before they damage the laser's optics, the facility potentially saves hundreds of thousands of dollars in maintenance costs each year.

42 ENGINEERING↗

A time-resolved, in-chamber x-ray pinhole imager for Z

We have commissioned a new time-resolved, x-ray imaging diagnostic for the Z facility. The primary intended application is for diagnosing the stagnation behavior of Magnetized Liner Inertial Fusion (MagLIF) and similar targets. We have a variety of imaging systems at Z, both time-integrated and time-resolved, that provide valuable x-ray imaging information, but no system at Z up to this time provides a combined high-resolution imaging with multi-frame time resolution; this new diagnostic, called TRICXI for Time Resolved In-Chamber X-ray Imager, is meant to provide time-resolved spatial imaging with high resolution. The multi-frame camera consists of a microchannel plate camera. A key component to achieving the design goals is to place the instrument inside the Z vacuum chamber within 2 m of the load, which necessitates a considerable amount of x-ray shielding as well as a specially designed, independent vacuum system. Here, a demonstration of the imaging capability for a series of MagLIF shots is presented. Predictions are given for resolution and relative image irradiance to guide experimenters in choosing the desired configuration for their experiments.

47 OTHER INSTRUMENTATION↗

Self-powered Wireless Dual-mode Langasite Sensor for Pressure/Temperature Monitoring of Nuclear Reactors

Safety issues in nuclear power plants are of extreme importance. Numerous sensors are used within nuclear power plants for sensing and monitoring of its critical operation parameters. As currently implemented, during massive losses of power across the plant in accidents, the backup batteries for the monitoring sensors will ultimately be drained and can cease to operate. The overall objective of this NEUP project is to develop a novel self-powered wireless hybrid sensor which can accurately monitor both pressure and temperature using a single device, even in the extreme harsh environments of severe nuclear accidents, without the requirement of external electricity. At Virginia Tech side, a heat pipe assisted thermoelectric generator (TEG) energy harvester and associated power management and data transmission circuits were developed. The energy harvester can produce electrical power continuously, even in loss of plant and external power situations, providing power for important data transmission for accident diagnosis. The self-powered sensing system could be integrated directly onto key nuclear components including pipes, pump housings, heat exchangers, reactor vessels, and shielding structures inside and outside of the reactor core. Two TEG based energy harvesters which can work in relatively low (50-250 ºC) and high temperature ranges (250-350 ºC) were established and tested. In the prototypes, heat pipes were introduced to reduce the heat resistances of the device at the hot and cold ends. The power output of the heat pipe assisted TEG module is 2.22 W, which is 6 times more than one using an aluminum rod. In-lab tests showed that these devices canmeet the requirement to power the sensors and circuit during normal and off-normal conditions.Amodel was then built to analyze the thermal network in the energy harvester, and was used to optimize its performance and reduce its geometry size. The design and testing of the vibrational energy harvester were completed. The harvester, has shown to effectively increase the vibrational potential of the main coolant pump, though it has been shown that thermal energy has a much higher potential for the powering of sensors. In this project, a self-start charger circuit for the energy harvester was designed to regulate and manage the power. An energy storage element was incorporated into the energy harvesting module for sensors and wireless transceivers in an off-normal situation. The signal conditioning and wireless communication electronic circuits were developed and tested in the lab. An important consideration for an energy harvester within a nuclear power plant is the level of radiation it will encounter during operation. The two main sources of radiation in a nuclear power plant are gamma and neutron radiation. Aradiation experiment was conducted in the Westinghouse Electric Company during which the prototypes were placed in a 106 rad radiation environment to test their ability to operate in the extreme environment. The results showed that this level of radiation had little effect on the performance of the TEGmaterial and heat pipe heat exchanging system. Its influence on the circuit was still under research, however the need for more development on radiation hardened electronics is needed. Pressure measurement based on piezoelectric crystal resonators has advantages over the commercially available methods like capacitive, electromagnetic, optical, potentiometric, and piezo resistive strain gauges. Since the output of piezoelectric based sensors are digital in format, it has a very high resolution, high accuracy, and long-term stability. Quartz is one of the commonly used piezoelectric material in digital pressure sensors design. This material is elastic in nature, providing high stability, high repeatability, high elasticity, repeatable mechanical behavior for many cycles of operation, and is free of hysteresis. The quartz resonator has a high Q, which means that very high vibration can be driven with the very low electric power. Langasite (LGS) is a new promising piezoelectric material that combines the advantageous properties of quartz with a better performance at high temperatures. LGS will not undergo any phase transitions up to its melting temperature of 1473 C, and hence, the application of Langasite in measuring pressure at high temperatures is promising. In this project, the design and fabrication of the piezo oscillator crystal for temperature and pressure measurement has been completed. The entire sensor has been fabricated and tested to see its sensitivity to temperature and pressure changes. The design and optimization of the radiation shielding systems that can effective protect the duel-mode Langasite sensor inside reactor core were demonstrated. To maximize the radiation shielding effectiveness, different types of materials are investigated based upon recent developments of radiation shielding systems including aluminum + Boron carbide and bismuth borosilicate glass B2O3 in addition to tungsten/B4C. New materials based upon metatheses is included as potential shielding to mitigate neutron fluencies. The radiation shielding effectiveness of selected composites are evaluated within a broader neutron spectrum from thermal, epithermal, fast (1 MeV) and 15 MeV neutrons. Performance analysis was also conducted to evaluate the effects of selected composite systems.Aconceptual design was also proposed for the packaging and integration of the radiation shielding system with the sensor, and its applicability within the reactor core was discussed. At end of the project, all components necessary for a complete sensing and monitoring system, including a langasite sensor, electrodes, the TEG harvester, an energy storage device, and power management and transmission electronics were integrated to demonstrate feasibility in powering the sensor. Finally, integration of each component into a full package, and a full demonstration were done.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effects of Prosthesis Stem Tapers on Stress Distribution of Cemented Hip Arthroplasty

Aseptic loosening effects are critical issues in encouraging long term stability of cemented hip arthroplasty. Stress shielding is believed to be an important factor that contributes to the aseptic loosening problems. The numerous changes in the prosthesis stem design are intended to minimize the stress shielding and aseptic loosening problems and to improve the long term performance of the implants. In this study, the stress distribution in cemented hip arthroplasty is established using finite element method. The taper of the prosthesis is designed to be 3 deg. at anterior/posterior, 3 deg. at medial/lateral and 10 deg. from wide lateral to narrow medial. Major muscle loads and contact forces are simulated for walking (toe-off phase) and stair climbing load cases. Effects of prosthesis stem tapers on the resulting stress distribution are investigated. Results show that compressive stress dominates in the medial plane while tensile stress in the lateral plane of the femur. The corresponding stress levels of intact femur for walking and stair-climbing load cases are 22 and 29 MPa, respectively. The magnitude of Tresca stress for the THA femur in stair-climbing load case remains higher in the region of 85 MPa while the walking load case induces around 40 MPa. The stress range in the straight and single taper stem prosthesis is lower than 260 MPa, while localized Tresca stress is in the order of the yield strength of Ti-6Al-4V alloy for double and triple taper stem design.

36 MATERIALS SCIENCE↗

Weld Quality Assessment in Fiber Laser Weldments of Ti-6Al-4V Alloy

Laser welding experiments are performed on Ti-6Al-4V alloy sheets by adopting fiber laser. A special kind of workpiece fixture is designed and fabricated for providing shielding gas. After experiments, penetration depth, fusion zone width and heat-affected zone size at different locations within weld bead are measured and discussed in detail. Influence of line energies on the formation of non-uniform microstructure within weld bead is explored by conducting microstructural analysis. Various kinds of microstructural morphology of martensitic structure such as α′ martensite, blocky α, massive α and basket-weave microstructure are found in fusion zone. Experimentally, it is found that beam power is the key parameter for controlling penetration depth. Higher hardness is noticed within fusion zone due to the existence of large volume of α′ martensite. Tensile strength and hardness of welded specimens are increased with decreasing line energy. Small amount of micropores are also found in solidified weld bead. However, its sizes are in acceptable range as per BSEN:4678 standard. Most favorable welding condition is identified as a combination of beam power of 800 W and welding speed of 1000 mm/min which yields full penetration, narrower bead width, small heat-affected zone, minimal defects and acceptable mechanical properties.

36 MATERIALS SCIENCE↗

Neutron and Gamma-ray Measurements

Due to high neutron and gamma-ray yields and large size plasmas many future fusion reactor plasma parameters such as fusion power, fusion power density, ion temperature, fuel mixture, fast ion energy and spatial distributions can be well measured by various fusion product diagnostics. Neutron diagnostics provide information on fusion reaction rate, which indicates how close is the plasma to the ultimate goal of nuclear fusion and fusion power distribution in the plasma core, which is crucial for optimization of plasma breakeven and burn. Depending on the plasma conditions neutron and gamma-ray diagnostics can provide important information, namely about dynamics of fast ion energy and spatial distributions during neutral beam injection, ion cyclotron heating and generated by fast ions MHD instabilities. The influence of the fast particle population on the 2-D neutron source profile was clearly demonstrated in JET experiments. 2-D neutron and gamma-ray source measurements could be important for driven plasma heating profile optimization in fusion reactors. To meat the measurement requirements in ITER the planned set of neutron and gamma ray diagnostics includes radial and vertical neutron and gamma cameras, neutron flux monitors, neutron activation systems and neutron spectrometers. The necessity of using massive radiation shielding strongly influences the diagnostic designs in fusion reactor, determines angular fields of view of neutron and gamma-ray cameras and spectrometers and gives rise to unavoidable difficulties in the absolute calibration. The development, testing in existing tokomaks and a possible engineering integration of neuron and gamma-ray diagnostic systems into ITER are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of backlighting sources for a Compton radiography diagnostic of inertial confinement fusion targets (invited)

We present scaled demonstrations of backlighter sources, emitting bremsstrahlung x rays with photon energies above 75 keV, that we will use to record x-ray Compton radiographic snapshots of cold dense DT fuel in inertial confinement fusion implosions at the National Ignition Facility (NIF). In experiments performed at the Titan laser facility at Lawrence Livermore National Laboratory, we measured the source size and the bremsstrahlung spectrum as a function of laser intensity and pulse length from solid targets irradiated at 2x10{sup 17}-5x10{sup 18} W/cm{sup 2} using 2-40 ps pulses. Using Au planar foils we achieved source sizes down to 5.5 {mu}m and conversion efficiencies of about 1x10{sup -13} J/J into x-ray photons with energies in the 75-100 keV spectral range. We can now use these results to design NIF backlighter targets and shielding and to predict Compton radiography performance as a function of the NIF implosion yield and associated background.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗