Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Enhanced TCAS 2/CDTI traffic Sensor digital simulation model and program description

Digital simulation models of enhanced TCAS 2/CDTI traffic sensors are developed, based on actual or projected operational and performance characteristics. Two enhanced Traffic (or Threat) Alert and Collision Avoidance Systems are considered. A digital simulation program is developed in FORTRAN. The program contains an executive with a semireal time batch processing capability. The simulation program can be interfaced with other modules with a minimum requirement. Both the traffic sensor and CAS logic modules are validated by means of extensive simulation runs. Selected validation cases are discussed in detail, and capabilities and limitations of the actual and simulated systems are noted. The TCAS systems are not specifically intended for Cockpit Display of Traffic Information (CDTI) applications. These systems are sufficiently general to allow implementation of CDTI functions within the real systems' constraints.

Goka, T.↗

1700 deg C optical temperature sensor

A new gas temperature sensor was developed that shows promise of sufficient ruggedness to be useful as a gas turbine temperature sensor. The sensor is in the form of a single-crystal aluminum oxide ceramic, ground to a cone shape and given an emissive coating. A lens and an optical fiber conduct the thermally emitted light to a remote and near-infrared photodetector assembly. Being optically coupled and passive, the sensor is highly immune to all types of electrical interference. Candidate sensors were analyzed for optical sensor performance, heat transfer characteristics, stress from gas loading. This led to the selection of the conical shape as the most promising for the gas turbine environment. One uncoated and two coated sensing elements were prepared for testing. Testing was conducted to an indicated 1750 C in a propane-air flame. Comparison with the referee optical pyrometer shows an accuracy of + or - 25 C at 1700 C for this initial development. One hundred cycles from room temperature to 1700 C left the sapphire cone intact, but some loss of the platinum, 6% rhodium coating was observed. Several areas for improving the overall performance and durability are identified.

Mossey, P. W.↗

Optical-system design for next-generation pushbroom sensors

Next-generation pushbroom sensors for earth observation require high-performance optics that provide high spatial resolution over wide fields of view. Specifically, blur diameters on the order of 10 to 15 microns are needed over 5 to 15 deg fields. In addition to this fundamental level of optical performance, other characteristics, such as spatial coregistration of spectral bands, flat focal plane, telecentricity, and workable pupil location are significant instrument design considerations. The detector-assembly design, optical line-of-sight pointing method and sensor packaging all hinge on these secondary attributes. Moreover, the need for broad spectral coverage, ranging from 0.4 to 12.5 microns, places an additional constraint on optical design. This paper presents alternative design forms that are candidates for wide-field pushbroom sensors, and discusses the instrument-design tradeoffs that are linked to the selection of these alternate optical approaches.

Mika, A. M.↗

Linear quadratic stationkeeping on travelling ellipses

An automatic controller for Space Shuttle stationkeeping or formationkeeping is presented. The controller, which is a candidate for future on-orbit autopilot enhancement, uses a fuel 'optimized' limit cycle trajectory in a feedforward loop for precise control at nonequilibrium set points. Disturbance rejection is accomplished by a discrete time, linear quadratic regulator, which is employed for tracking of the feedforward model. Feedback gain selection is done to provide good limit cycling performance and low fuel consumption. Velocity correlations are carried out by use of a pseudo 6 degree-of-freedom jet selection scheme. Results indicate that 20 ft precision can be achieved using current sensors.

Adams, Neil J.↗

Comparison of wind speed measurements over the oceans with the Special Sensor Microwave/Imager and the Geosat altimeter

In order to compare wind speed estimates from the Geosat altimeter and the Special Sensor Microwave/Imager (SSM/I), 25 colocated passes, within 2 hours of each other, were selected and the SSM/I estimates of wind speed and atmospheric parameters extracted along the Geosat track. Both instruments and their algorithms are described. A statistical comparison of wind speed estimates is presented and the effects of the atmospheric parameters from Geosat are analyzed. Quasi-simultaneous measurements by Geosat and SSM/I, along a Geosat track in the North-East Pacific, are also presented.

Mognard, Nelly M.↗

Comparison of wind speed measurements over the oceans with the Special Sensor Microwave/Imager and the Geosat altimeter

In order to compare wind speed estimates from the Geosat altimeter and the Special Sensor Microwave/Imager (SSM/I), 25 colocated passes, within 2 hours of each other, were selected and the SSM/I estimates of wind speed and atmospheric parameters extracted along the Geosat track. Both instruments and their algorithms are described. A statistical comparison of wind speed estimates is presented and the effects of the atmospheric parameters from Geosat are analyzed. Quasi-simultaneous measurements by Geosat and SSM/I, along a Geosat track in the North-East Pacific, are also presented.

Mognard, Nelly M.↗

Analysis of In-Flight Vibration Measurements from Helicopter Transmissions

In-flight vibration measurements from the transmission of an OH-58C KIOWA are analyzed. In order to understand the effect of normal flight variation on signal shape, the first gear mesh components of the planetary gear system and bevel gear are studied in detail. Systematic patterns occur in the amplitude and phase of these signal components with implications for making time synchronous averages and interpreting gear metrics in flight. The phase of the signal component increases as the torque increases; limits on the torque range included in a time synchronous average may now be selected to correspond to phase change limits on the underlying signal. For some sensors and components, an increase in phase variation and/or abrupt change in the slope of the phase dependence on torque are observed in regions of very low amplitude of the signal component. A physical mechanism for this deviation is postulated. Time synchronous averages should not be constructed in torque regions with wide phase variation.

Mosher, Marianne↗

ICESat Observations of Inland Surface Water Stage, Slope, and Extent: a New Method for Hydrologic Monitoring

River discharge and changes in lake, reservoir and wetland water storage are critical terms in the global surface water balance, yet they are poorly observed globally and the prospects for adequate observations from in-situ networks are poor (Alsdorf et al., 2003). The NASA-sponsored Surface Water Working Group has established a framework for advancing satellite observations of river discharge and water storage changes which focuses on obtaining measurements of water surface height (stage), slope, and extent. Satellite laser altimetry, which can achieve centimeter-level elevation precision for single, small laser footprints, provides a method to obtain these inland water parameters and contribute to global water balance monitoring. Since its launch in January, 2003 the Ice, Cloud, and land Elevation Satellite (ICESat), a NASA Earth Observing System mission, has achieved over 540 million laser pulse observations of ice sheet, ocean surface, land topography, and inland water elevations and cloud and aerosol height distributions. By recording the laser backscatter from 80 m diameter footprints spaced 175 m along track, ICESat acquires globally-distributed elevation profiles, using a 1064 nm laser altimeter channel, and cloud and aerosol profiles, using a 532 nm atmospheric lidar channel. The ICESat mission has demonstrated the following laser altimeter capabilities relevant to observations of inland water: (1) elevation measurements with a precision of 2 to 3 cm for flat surfaces, suitable for detecting river surface slopes along long river reaches or between multiple crossings of a meandering river channel, (2) from the laser backscatter waveform, detection of water surface elevations beneath vegetation canopies, suitable for measuring water stage in flooded forests, (3) single pulse absolute elevation accuracy of about 50 cm (1 sigma) for 1 degree sloped surfaces, with calibration work in progress indicating that a final accuracy of about 12 cm (1 sigma) will be achieved for clear atmosphere conditions, suitable for detection of stage changes through time, (4) ability to precisely point the spacecraft so as to position the laser profile on the Earth the surface with a cross-track accuracy of 50 m (1 sigma), enabling small water bodies and specific locations to be targeted and re-observed through time, (5) adequate signal levels from specular water surfaces up to 5 degrees off-nadir, enabling complete global access to any location on the Earth's surface from the ICESat repeat orbit by off-nadir pointing, and (6) day and night operation with successful laser ranging to the Earth's surface through thin to moderate cloud cover, enabling more frequent measurements than can be achieved by passive optical sensors. Here we illustrate these capabilities by showing ICESat observations through time for selected river and lake locations.

Harding, David J.↗

Real Time Oil Reservoir Evaluation Using Nanotechnology

A method and system for evaluating status and response of a mineral-producing field (e.g., oil and/or gas) by monitoring selected chemical and physical properties in or adjacent to a wellsite headspace. Nanotechnology sensors and other sensors are provided for one or more underground (fluid) mineral-producing wellsites to determine presence/absence of each of two or more target molecules in the fluid, relative humidity, temperature and/or fluid pressure adjacent to the wellsite and flow direction and flow velocity for the fluid. A nanosensor measures an electrical parameter value and estimates a corresponding environmental parameter value, such as water content or hydrocarbon content. The system is small enough to be located down-hole in each mineral-producing horizon for the wellsite.

Li, Jing↗

Fossil Power Plant Cyber Security Life-Cycle Risk Reduction: A Practical Framework for Implementation

Market conditions are forcing fossil electricity generation facility owners and operators to implement advanced digital technologies. These technologies enable efficiencies, operational flexibility, operations and maintenance efficiencies, and adapting to a transitioning workforce. These digital technologies, however, can increase the cybersecurity attack surface. The purpose of this research was to develop a holistic cybersecurity risk reduction framework for fossil generation facilities. The framework begins with assessing how cyber risk changes across facility life cycles, including plant, system, vendor, and business life cycles. The next phase performs consequence analysis to prioritize high consequence events. Focusing on high consequence events allows owners to use a graded, risk-informed approach to prioritize cybersecurity efforts. The final phase identifies the digital asset attack surface in sensors and instrumentation and control equipment. After the vulnerabilities are identified, the owner selects mitigating cybersecurity control measures (or countermeasures) based on the risk analysis from the previous phases. This report describes the current industry cybersecurity best practices in fossil generation that are based on the first principles for cybersecurity engineering. The report is divided into five sections that describe the implementation of the risk reduction framework and present identified research, methodological, and technology gaps that were identified through this course of research and development.

20 FOSSIL-FUELED POWER PLANTS↗

Fossil Power Plant Cyber Security Life-Cycle Risk Reduction: A Practical Framework for Implementation

Market conditions are forcing fossil electricity generation facility owners and operators to implement advanced digital technologies. These technologies enable efficiencies, operational flexibility, operations and maintenance efficiencies, and adapting to a transitioning workforce. These digital technologies, however, can increase the cybersecurity attack surface. The purpose of this research was to develop a holistic cybersecurity risk reduction framework for fossil generation facilities. The framework begins with assessing how cyber risk changes across facility life cycles, including plant, system, vendor, and business life cycles. The next phase performs consequence analysis to prioritize high consequence events. Focusing on high consequence events allows owners to use a graded, risk-informed approach to prioritize cybersecurity efforts. The final phase identifies the digital asset attack surface in sensors and instrumentation and control equipment. After the vulnerabilities are identified, the owner selects mitigating cybersecurity control measures (or countermeasures) based on the risk analysis from the previous phases. This report describes the current industry cybersecurity best practices in fossil generation that are based on the first principles for cybersecurity engineering. The report is divided into five sections that describe the implementation of the risk reduction framework and present identified research, methodological, and technology gaps that were identified through this course of research and development.

20 FOSSIL-FUELED POWER PLANTS↗

Feasibility study of the application of existing techniques to remotely monitor hydrochloric acid in the atmosphere

A critical evaluation of existing optical remote sensors for HCl vapor detection in solid propellant rocket plumes is presented. The P branch of the fundamental vibration-rotation band was selected as the most promising spectral feature to sense. A computation of transmittance for HCl vapor, an estimation of interferent spectra, the application of these spectra to computer modelled remote sensors, and a trade-off study for instrument recommendation are also included.

Zwick, H.↗

The Rome-GSFC magnetic field experiment for Helios A and B /E 3/

The Rome-GSFC magnetic field experiment utilizes a triaxial fluxgate (saturable inductor) magnetometer. The sensor unit is mounted on the end of a boom approximately four meters from the spacecraft spin axis. The three analog outputs of the magnetometer are converted into three 9 bit digital words. The experiment utilizes an automatic inflight range switch to select the optimum dynamic range out of 4 ranges. A nonmagnetic thermally oscillating actuator is used to reorient the sensor unit by 90 deg to determine all three axes zero levels. The accuracy should be approximately plus or minus 0.1 gamma. The vector measurements are made at equal intervals in time ranging from 16 per second down to 1 per second depending on the telemetry bit rate.

Scearce, C.↗

A Chimeric LBT-GFP Biosensor Exhibits Antithetical Fluorescence Responses to Ca 2+ and Dy 3+ Binding

Rare earth elements (REEs) are critical components in emerging technologies, but their mining and refining processes are often laborious, costly, and environmentally damaging. Developing green and efficient separation methods for REEs is crucial. Biomolecular approaches using lanthanide-binding proteins and peptides show promise for selective REE extraction and separation. In this study, we present the design and characterization of a genetically encoded fluorescence indicator (GEFI) construct that combines a superfolder green fluorescent protein (sfGFP) with a dual lanthanide-binding tag (2×dLBT). The 2×dLBT insert induces conformational changes in sfGFP upon lanthanide binding, modulating the fluorescence intensity. The sfGFP-2×dLBT biosensor exhibited distinct fluorescence responses to different lanthanide ions, with the highest dynamic range observed for heavy REEs like dysprosium (Dy 3+ ). Interestingly, the sensor displayed an antithetical response, where low concentrations of lanthanides initially quenched the fluorescence, but higher concentrations led to a significant fluorescence increase (1.5-fold). The Ca 2+ ion on the other hand showed only a dose-dependent quenching of the fluorescence response. Based on these observations, the biphasic response of the biosensor to lanthanides was eliminated by pretreating the sensor with calcium, which further expanded the dynamic range up to 3-fold for Dy 3+ . The lanthanide-selective and concentration-dependent fluorescence changes of the sfGFP-2×dLBT biosensor demonstrate its potential as a platform for developing specific sensors for various REEs. These sensors could enable rapid and cost-effective determination of REE composition in complex mixtures, facilitating the separation and recovery of critical REEs from electronic waste and other REE-containing sources.

59 BASIC BIOLOGICAL SCIENCES↗

Path selection system simulation and evaluation for a Martian roving vehicle

The simulation and evaluation of proposed path selection systems for an autonomous Martian roving vehicle was developed. The package incorporates a number of realistic features, such as the simulation of random effects due to vehicle bounce and sensor-reading uncertainty, to increase the reliability of the results. Qualitative and quantitative evaluation criteria were established. The performance of three different path selection systems was evaluated to determine the effectiveness of the simulation package, and to form some preliminary conclusions regarding the tradeoffs involved in a path selection system design.

Boheim, S. L.↗

Low cost environmental sensors for Spaceflight : NMP Space Environmental Monitor (SEM) requirements

An outstanding problem in spaceflight is the lack of adequate sensors for monitoring the space environment and its effects on engineering systems. By adequate, we mean low cost in terms of mission impact (e.g., low price, low mass/size, low power, low data rate, and low design impact). The New Millennium Program (NMP) is investigating the development of such a low-cost Space Environmental Monitor (SEM) package for inclusion on its technology validation flights. This effort follows from the need by NMP to characterize the space environment during testing so that potential users can extrapolate the test results to end-use conditions. The immediate objective of this effort is to develop a small diagnostic sensor package that could be obtained from commercial sources. Environments being considered are: contamination, atomic oxygen, ionizing radiation, cosmic radiation, EMI, and temperature. This talk describes the requirements and rational for selecting these environments and reviews a preliminary design that includes a micro-controller data logger with data storage and interfaces to the sensors and spacecraft. If successful, such a sensor package could be the basis of a unique, long term program for monitoring the effects of the space environment on spacecraft systems.

Galileo↗

Low Cost Environmental Sensors for Spaceflight: NMP Space Environmental Monitor (SEM) Requirements

An outstanding problem in spaceflight is the lack of adequate sensors for monitoring the space environment and its effects on engineering systems. By adequate, we mean low cost in terms of mission impact (e.g., low price, low mass/size, low power, low data rate, and low design impact). The New Millennium Program (NMP) is investigating the development of such a low-cost Space Environmental Monitor (SEM) package for inclusion on its technology validation flights. This effort follows from the need by NMP to characterize the space environment during testing so that potential users can extrapolate the test results to end-use conditions. The immediate objective of this effort is to develop a small diagnostic sensor package that could be obtained from commercial sources. Environments being considered are: contamination, atomic oxygen, ionizing radiation, cosmic radiation, EMI, and temperature. This talk describes the requirements and rational for selecting these environments and reviews a preliminary design that includes a micro-controller data logger with data storage and interfaces to the sensors and spacecraft. If successful, such a sensor package could be the basis of a unique, long term program for monitoring the effects of the space environment on spacecraft systems.

New Millennium Program (NMP)↗

Focal-plane optimization for detector noise limited performance in cryogenic Fourier transform spectrometer /FTS/ sensors

A study was performed to determine the optimum focal plane configuration including optics, filters and detector-preamplifier selection. The configuration was optimized particularly with respect to minimizing the noise level, but fabrication considerations for a cryogenic environment were also taken into account. The noise terms from source, background, detector electronics and charged particle radiation were quantitatively evaluated. It appears that noise equivalent spectral radiance less than 10 to the -11th W/sq cm per sr per kayser can be achieved between 2.5 and 20 microns.

Mcguirk, M.↗