Reduction of detection limit and quantification uncertainty due to interferent by neural classification with abstention

Many measurements in the physical sciences can be cast as counting experiments, where the number of occurrences of a physical phenomenon informs the prevalence of the phenomenon's source. Often, detection of the physical phenomenon (termed signal) is difficult to distinguish from naturally occurring phenomena (termed background). In this case, the discrimination of signal events from background can be performed using classifiers, and they may range from simple, threshold-based classifiers to sophisticated neural networks. These classifiers are often trained and validated to obtain optimal accuracy, however we show that the optimal accuracy classifier does not generally coincide with a classifier that provides the lowest detection limit, nor the lowest quantification uncertainty. Here, we present a derivation of the detection limit and quantification uncertainty in the classifier-based counting experiment case. We also present a novel abstention mechanism to minimize the detection limit or quantification uncertainty a posteriori. We illustrate the method on two data sets from the physical sciences, discriminating Ar-37 and Ar-39 radioactive decay from non-radioactive events in a gas proportional counter, and discriminating neutrons from gammas in an inorganic scintillator and report results therefrom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Mu2e experiment — Searching for charged lepton flavor violation

The Mu2e experiment will search for a Standard Model violating rate of neutrinoless conversion of a muon into an electron in the presence of an aluminum nucleus. Observation of this charged lepton flavor violating process would be an unambiguous sign of new physics. Mu2e will improve upon previous searches for this process by four orders of magnitude. This requires the world’s highest-intensity muon beam, a detector system capable of efficiently reconstructing the 105 MeV/c conversion electron signal, and minimizing sensitivity to background events. A pulsed 8 GeV proton beam strikes a target, producing pions that decay into muons. Beam outside the pulse must be suppressed to < 1 0 – 10 to reduce beam-related backgrounds. The muon beam is guided from the production target along the transport system and onto the aluminum stopping target. Conversion electrons leave the stopping target and propagate inside a solenoidal magnetic field to the tracker and electromagnetic calorimeter. The tracker is a system of straw tube panels filled with Ar/CO 2 at 1 atm that tracks particles inside of a solenoidal B-field and measures their momenta with ~ 100 keV/c resolution to resolve signal events from decay-in-orbit backgrounds. The CsI calorimeter provides E / p and is used to seed the track reconstruction algorithm with σ E / E ~ 10 % and σ t < 500 ps . Additionally, a novel cosmic ray veto with greater than 99.99% efficiency brings the expected number of background events to fewer than one over three years of running. Finally, to normalize the experiment, the stopping target monitor measures the rate of capture photons from muons incident on the stopping target by using a system of high-purity germanium and lanthanum bromide scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel imaging technique for thermal neutrons using a fast optical camera

A novel imaging technique for thermal neutrons using a fast optical camera is presented. Thermal neutrons are reacted with 6 Lithium to produce a pair of 2.73 MeV tritium and 2.05 MeV alpha particles, which in turn interact in a thin layer of LYSO crystal scintillator to produce a localized flash of light. These photons are directed by a pair of lenses to a micro-channel plate intensifier, and its output is connected to the optical camera, TPX3CAM. The results from the camera are reconstructed through a custom algorithm. Various cutting parameters were found through data analysis to eliminate the background, and they were shown effective in matching the simulated rate of the neutron source. The system is fast with 40 ns decay time and allows free-space light collection, both vastly enhances flexibility of neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high-granularity calorimeter insert based on SiPM-on-tile technology at the future Electron-Ion Collider

Herein we present a design for a high-granularity calorimeter insert for future experiments at the Electron-Ion Collider (EIC). The sampling-calorimeter design uses scintillator tiles read out with silicon photomultipliers. It maximizes coverage close to the beampipe, while solving challenges arising from the beam-crossing angle and mechanical integration. It yields a compensated response that is linear over the energy range of interest for the EIC. Its energy resolution meets the requirements set in the EIC Yellow Report even with a basic reconstruction algorithm. Moreover, this detector will provide 5D shower data (position, energy, and time), which can be exploited with machine-learning techniques. This detector concept has the potential to unleash the power of imaging calorimetry at the EIC to enable measurements at extreme kinematics in electron–proton and electron–nucleus collisions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of $\text{BDX-MINI}$ veto systems

Here this paper describes the veto system of the BDX-MINI detector installed at Jefferson Lab (US). The BDX-MINI experiment is the first electron beam-dump experiment specifically designed to search for Light Dark Matter (LDM) particles in the MeV-GeV mass range. The core of the BDX-MINI detector is a lead-tungstate electromagnetic calorimeter, for a total volume of 4 dm 3 . The calorimeter is surrounded by a multi-layer veto aimed at rejecting cosmic background: the innermost layer of the veto is made by a passive tungsten shielding for low energy radiation, while plastic scintillators make the middle and outer layers for charged cosmic particles rejection. Being located about 20 m downstream, the dirt between the beam dump and the detector provides sufficient shielding from the beam-related background. In 2019–2020, BDX-MINI was exposed for about six months to weakly interacting particles (neutrinos and, if existing, DM) produced by a 2.176 GeV electron beam incident on the beam dump of experimental Hall-A at Jefferson Lab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A flexible event reconstruction based on machine learning and likelihood principles

Event reconstruction is a central step in many particle physics experiments, turning detector observables into parameter estimates; for example estimating the energy of an interaction given the sensor readout of a detector. A corresponding likelihood function is often intractable, and approximations need to be constructed. Here, in our work, we first show how the full likelihood for a many-sensor detector can be broken apart into smaller terms, and secondly how we can train neural networks to approximate all terms solely based on forward simulation. Our technique results in a fast, flexible, and close-to-optimal surrogate model proportional to the likelihood and can be used in conjunction with standard inference techniques allowing for a consistent treatment of uncertainties. We illustrate our technique for parameter inference in neutrino telescopes based on maximum likelihood and Bayesian posterior sampling. Given its great flexibility, we also showcase our method for geometry optimization enabling to learn optimal detector designs. Lastly, we apply our method to realistic simulation of a ton-scale water-based liquid scintillator detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrumentation for correlated prompt n – γ emission studies in coincidence with fission fragments

Recent theoretical and experimental results have brought renewed interest and focus on the topic of fission fragment angular momentum. Measurements of neutrons and rays in coincidence with fission fragments remain the most valuable tool in the exploration of fission physics. To achieve these scientific goals, we have developed a system that combines a state-of-the-art fission fragment detector and n – γ radiation detectors. A new twin Frisch-gridded ionization chamber has been designed and constructed for use with a spontaneous fission source and an array of forty trans-stilbene organic scintillators (FS-3) at Argonne National Laboratory. The new ionization chamber design we present in this work aims at minimizing particle attenuation in the chamber walls, and provides a compact apparatus that can be fit inside existing experimental systems. The ionization chamber is capable of measuring fission fragment masses and kinetic energies, whereas the FS-3 provides neutron and γ-ray multiplicities and spectra. Here, the details of both detector assemblies are presented along with the first experimental results of this setup. Planned event-by-event analysis and future experiments are briefly discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High event rate analysis technique for the dual-axis duo-lateral position-sensitive silicon detectors of FAUST

The dual-axis duo-lateral (DADL) position-sensitive silicon detector was developed to obtain precise position and energy information for detected charged particles. The Forward Array Using Silicon Technology (FAUST) is currently equipped with 68 DADL detectors backed by CsI(Tl) scintillators for the study of charged particle correlations in heavy-ion collisions where precise position and energy information is essential. When conventional signal processing electronics were used for the DADL detectors, a position dependence of the measured energy as well as distortions in the calculated particle positions were observed. In previous work, waveforms from the detector after preamplification were studied to better understand the features that give rise to these distortions; therein, a waveform analysis technique was developed to improve the energy resolution and linearity in position reconstruction. However, the reading and writing of waveforms for an entire detector array limits data collection rates and adds significant burden in data storage and analysis speed. In this work, the integrators of a Struck SIS3316 ADC were utilized to process 228 Th source data to develop and optimize a new analysis method that captures the benefits of the waveform analysis technique while circumventing the waveform writing requirement. This integrator method – capable of 59 keV (FWHM) energy resolution – was used in the collection of 35 MeV/nucleon 28 Si + 12 C collision data using FAUST to investigate exotic decays of highly excited highly deformed nuclei. In this data, a position resolution of 0.4 mm (FWHM) was obtained for 25 MeV α-particles; for α-particles near this energy that originate from 8 Be ground state decays, a 8 Be ground state width of 30 keV (FWHM) was obtained. The impact of the energy-dependent DADL position resolution emergent from electronic noise on the quality of excited state measurement was modeled and compared to the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated integration gate selection for Gaussian mixture model pulse shape discrimination

Pulse shapes differ between neutron and gamma particles when measured with detector devices employing pulse shape discriminating (PSD) scintillators. Digitized waveforms can be used in detection systems to perform pulse shape discrimination for this application. Prior Gaussian Mixture Model (GMM) methods require access to the pulse full-waveform. Reducing the waveform to a smaller set of combined samples reduces computational cost while affecting PSD performance. In this work, we develop a method for selecting the best performing combination of integration gates, or contiguous summed segments of the digitized pulse for PSD. The method uses a discrimination score based on the GMM PSD approach. Furthermore, the final selection is performed using Bayesian Optimization. PSD detection results are compared with varying numbers of selected gates on time-of-flight (TOF) data. This method can be used to fully automate the selection of gates in an unsupervised (without ground truth labels) setting.

42 ENGINEERING↗

BlueSTEAl: A pair of silicon arrays and a zero-degree phoswich detector for studies of scattering and reactions in inverse kinematics

BlueSTEAl, the Blue (aluminum chamber of) Silicon TElescope Arrays for light nuclei, has been developed to study direct reactions in inverse kinematics, as well as scattering and breakup reactions using radioactive ion beams. It is a detector system consisting of a pair of annular silicon detector arrays and a zero-degree phoswich plastic scintillator. For typical binary reaction studies in inverse kinematics, light ions are detected by the Si array in coincidence with heavy recoils detected by the phoswich placed at the focal-plane of a zero-degree magnetic spectrometer. The Si array can also be used to detect light nuclei such as beryllium and carbon with clear isotope separation, while the phoswich can also be placed at zero degrees without a spectrometer and used as a high-efficiency beam counting monitor with particle identification capability at the rate of up to ~5 × 10 4 particles per second. This paper reports on the capabilities of BlueSTEAl as determined by recent experiments performed at the Texas A&M Cyclotron Institute. Furthermore, the device is also anticipated to be used in future experiments at other radioactive ion beam facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

GENESIS: Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering

Improved neutron inelastic scattering cross section data are needed to inform integral benchmark studies and advance applications in a wide variety of areas including nuclear energy, stockpile stewardship, nonproliferation, and space exploration. Neutron inelastic scattering also serves as a non-selective probe of low-lying nuclear structure. To help meet these needs, the Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) was constructed at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. This array couples high-resolution γ-ray detectors and fast neutron detectors to achieve single and coincident n/γ detection over a broad energy range. The current configuration of the array includes 26 organic liquid scintillators and four high-purity germanium detectors (two single-crystal and two four-crystal CLOVER detectors with two-fold segmentation). The array was constructed with minimal supporting material and designed to cover a wide range of secondary particle angles and energies with limited inter-element scattering. Data acquisition is accomplished using Mesytec MDPP-16 multi-channel high-resolution digital pulse processing modules. The array characteristics, including γ-ray and neutron energy resolution, timing resolution, and detection efficiency were measured and used to validate a Geant4 model of the array. Furthermore, the primary sources of neutron background and the uncertainties in the determination of incident and secondary neutron energy were assessed. GENESIS provides a new capability to address nuclear data needs and facilitates the advancement of a wide range of nuclear applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron resonance transmission analysis prototype system for thorium fuel cycle safeguards

Emerging thorium-based reactor designs and fuel cycles present challenges to traditional non-destructive assay techniques used in international safeguards. Specifically, assaying the masses of 233 U and 235 U when they are present together in samples with high gamma ray backgrounds is difficult because of similar passive neutron signatures and relatively weak gamma-ray emissions of 233 U. The Pacific Northwest National Laboratory (PNNL) and the Massachusetts Institute of Technology (MIT) are developing a compact neutron resonance transmission analysis (NRTA) system as one potential solution to these challenges. The NRTA technique provides isotopic information for a sample via neutron time-of-flight (TOF) measurements that exploit a sample’s epithermal neutron resonance cross-sections. A recently developed portable NRTA system uses a commercially available, pulsed deuterium-tritium neutron generator with a ~2 m flight path and a GS20 lithium glass scintillator detector. Finally, this paper describes the prototype NRTA system design, a refined radiation transport model of the system, preliminary measurements with thorium and uranium sources, and demonstration of a quantitative isotopic estimation algorithm.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The LSU-Argonne conversion electron spectrometer: A new detector for the X-Array and SATURN decay station

In this study, a new conversion electron detector has been commissioned at the ATLAS/ CARIBU facility at Argonne National Laboratory. The LSU-Argonne Conversion Electron Spectrometer (LACES) is a LN 2 -cooled Si(Li) detector system designed to be incorporated into a decay station that comprises the dedicated HPGe clover array with a box geometry (X -Array) and the Scintillator and Tape Using Radioactive Nuclei (SATURN) device. This integration enables simultaneous measurements of conversion electrons and gamma-rays in decay experiments, yielding novel information on transition multipolarities, electric monopole transitions, and isomeric states that decay mostly via conversion electrons. A measurement of the energy resolution of LACES yielded 2.3-keV FWHM at 975 keV for electrons and 1.3-keV FWHM at 75 keV for X-rays. A detailed study of the absolute detection efficiency (at 5 mm from the source) was performed, where this quantity was determined experimentally in the range of electron transition energies between 25.5 keV and 1047.8 keV and subsequently simulated using the GEANT4 code. Measurement and simulations are found to be in excellent agreement. A precise characterization, for this type of detector system, of the absolute detection efficiency for such a wide energy range is reported for the first time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spherical time-encoded radiation imaging simulations

Radiation source localization is important for nuclear nonproliferation and can be obtained using time-encoded imaging systems with unsegmented detectors. A scintillation crystal can be used with a moving coded-aperture mask to vary the detected count rate produced from radiation sources in the far field. The modulation of observed counts over time can be used to reconstruct an image with the known coded-aperture mask pattern. Current time-encoded imaging systems incorporate cylindrical coded-aperture masks and have limits to their fully coded imaging field-of-view. This work focuses on expanding the field-of-view to 4π by using a novel spherical coded-aperture mask. A regular icosahedron is used to approximate a spherical mask. This icosahedron consists of 20 equilateral triangles; the faces of which are each subdivided into four equilateral triangle-shaped voxels which are then projected onto a spherical surface, creating an 80-voxel coded-aperture mask. Furthermore, these polygonal voxels can be made from high-Z materials for gamma-ray modulation and/or low-Z materials for neutron modulation. In this work, we present Monte Carlo N-Particle (MCNP) simulations and simple models programmed in Mathematica to explore image reconstruction capabilities of this 80-voxel coded-aperture mask.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The data acquisition system of the LZ dark matter detector: FADR

The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals. This information is used to determine if the digitized waveforms should be preserved for offline analysis. The system is designed around the Kintex-7 FPGA. In addition to digitizing the PMT signals and providing basic event selection in real time, the flexibility provided by the use of FPGAs allows us to monitor the performance of the detector and the DAQ in parallel to normal data acquisition. Furthermore, the hardware and software/firmware of this FPGA-based Architecture for Data acquisition and Realtime monitoring (FADR) are discussed and performance measurements are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Power over fiber development for HEP detectors

Power-over-Fiber (PoF) technology has been used extensively in settings where high voltages require isolation from ground and electromagnetic isolation is critical. In cryogenic environments, PoF offers a reliable power transmission technology, leveraging optical fibers to transfer power with minimal system degradation. PoF technology excels in maintaining low noise levels and isolation when delivering power to sensitive electronic systems operating in extreme temperature ranges and high voltage environments. Here, in a novel application of PoF for a HEP detector, power is provided to photon detector modules located on a surface at ~300 kV with respect to ground in the planned DUNE experiment. This summary paper of the PoF talk at the 16th PISA Meeting on Advanced Detectors highlights the R&D effort of PoF in extreme conditions and underscores its capacity to revolutionize power delivery and management in critical applications offering a dependable solution with low noise, optimal efficiency, and superior isolation. The DUNE (Abi et al., 2020) experiment will soon deploy large liquid argon (LAr) time projection chambers (TPC) to detect neutrino interactions and other particle physics phenomena. In addition to the particle tracking provided by the TPC, photon detectors, powered by a first ever PoF system, in the cryostat will leverage the high scintillation light yield of LAr to provide crucial timing and additional calorimetric information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rate-induced aging effects on Parallel-Plate Avalanche Counter (PPAC) caused by heavy ion beams

The Facility for Rare Isotope Beams (FRIB) is one of the premier scientific user facilities for nuclear science with radioactive beams, capable of producing most (approximately 80%) of the isotopes expected to exist, from oxygen to uranium, at energies up to 200 MeV/u. With the increase in beam power from the present 10 kW to the planned 400 kW, FRIB experiments are about to enter a new era. An unprecedented rate capability as well as stable performance of all the planned instrumentation intended for beam diagnostics and beam tuning is required at the expected high beam intensities (> 1 MHz). A summary of aging phenomena at high heavy-ion beam rates observed in the Advanced Rare Isotope Separator (ARIS) detectors for beam diagnostics, including Parallel Plate Avalanche Counters (PPAC) and plastic scintillation for time-of-flight measurements, is discussed. Current research and development project to mitigate rate-induced aging are presented.

Aging effects↗

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called γ-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps towards such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C 6 D 6 detectors, and one LaCl 3 (Ce) detector. The performance of these detection systems is compared using 93 Nb(n, γ) data. We also developed a detailed G EANT small4 Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a γ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigated experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability.