Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Rapid determination of radiostrontium in seawater samples

A new method for the determination of radiostrontium in seawater samples has been developed at the Savannah River National Laboratory (SRNL) that allows rapid preconcentration and separation of strontium and yttrium isotopes in seawater samples for measurement. The new SRNL method employs a novel and effective pre-concentration step that utilizes a blend of calcium phosphate with iron hydroxide to collect both strontium and yttrium rapidly from the seawater matrix with enhanced chemical yields. The pre-concentration steps, in combination with rapid Sr Resin and DGA Resin cartridge separation options using vacuum box technology, allow seawater samples up to 10 liters to be analyzed. The total 89 Sr + 90 Sr activity may be determined by gas flow proportional counting and recounted after ingrowth of 90 Y to differentiate 89 Sr from 90 Sr. Gas flow proportional counting provides a lower method detection limit than liquid scintillation or Cerenkov counting and allows simultaneous counting of samples. Simultaneous counting allows for longer count times and lower method detection limits without handling very large aliquots of seawater. Seawater samples up to 6 liters may be analyzed using Sr Resin for 89 Sr and 90 Sr with a Minimum Detectable Activity (MDA) of 1-10 mBq/L, depending on count times. Seawater samples up to 10 liters may be analyzed for 90 Sr using a DGA Resin method via collection and purification of 90 Y only. If 89 Sr and other fission products are present, then 91 Y (beta energy 1.55 MeV, 58.5 day half-life) is also likely to be present. 91 Y interferes with attempts to collect 90 Y directly from the seawater sample without initial purification of Sr isotopes first and 90 Y ingrowth. The DGA Resin option can be used to determine 90 Sr, and if 91 Y is also present, an ingrowth option with using DGA Resin again to collect 90 Y can be performed. An MDA for 90 Sr of <1 mBq/L for an 8 hour count may be obtained using 10 liter seawater sample aliquots.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Efficient Surrogate Model Development: Impact of Sample Size and Underlying Model Dimensions

This study compares eight surrogate-model construction approaches using computational experiments. Here, the construction approaches considered include: Artificial Neural Networks (ANNs), Automated Learning of Algebraic Models using Optimization (ALAMO), Radial Basis Networks (RBNs), Extreme Learning Machines (ELMs), Gaussian Progress Regression (GPR), Random Forests (RFs), Support Vector Regression (SVR), and Multivariate Adaptive Regression Splines. Each approach is used to construct surrogate models for predicting the outputs of thirty-four test functions. The data used to construct surrogate models were generated using Latin Hypercube Sampling (LHS), Halton and Sobol sampling methods. We studied the impact of sampling method, sample size, and challenge function characteristics on the accuracy of surrogate model predictions. Our results revealed that for smaller sample sizes, on average, surrogate models trained using the data points generated by Sobol sequences provided the best estimation for all surrogate model construction approaches. As the sample size increased, the impact of sampling methods diminished. The comparison of surrogate-modeling construction approaches at large sample sizes revealed that surrogate models trained using ANN, ALAMO, and ELM yielded smaller root mean squared error and higher adjusted R-squared values than the models trained using the rest of the approaches.

42 ENGINEERING↗

Comparison of measurement techniques and sorption of radium-226 in low and high salinity aqueous samples

Human activities have the potential to redistribute radium (Ra) in the marine environment in a manner that may necessitate monitoring or management of subsequent human or environmental exposures. There is therefore a need to identify accurate and accessible techniques for Ra measurement in high salinity samples and to describe the distribution of Ra in estuarine and marine environments, but most efforts in these areas have focused on low salinity matrices. In addition, rapid and reliable measurements are crucial for time-sensitive samples such as short-lived isotopes or emergency situations. The objective of this study is to describe the limits of detection, cost, and relative ease for measurement of Ra in both low and high salinity aqueous samples via three analytical methods: liquid scintillation counting (LSC), high purity germanium (HPGe) gamma spectrometry, and inductively coupled plasma mass spectrometry (ICP-MS). To contextualize these measurements for real-world scenarios, the partitioning of 226 Ra to substrates relevant to the marine environment was also characterized. Although HPGe detection with solid phase extraction had the lowest limit of detection for low salinity samples (0.27 Bq L −1 ), poor 226 Ra recovery for high salinity samples and high materials costs make this method prohibitive for many users. Limits of detection for high salinity samples were lower for LSC (1.28 Bq L −1 ) than for ICP-MS without dilution (11.4 Bq L −1 ), but significant and unexpected degradation of the high salinity LSC standards was observed after six months. Furthermore, our preferred measurement method for high salinity Ra samples is ICP-MS with sample dilution as necessary to reduce matrix effects.

07 ISOTOPE AND RADIATION SOURCES↗

Sample environment effects on synchrotron-measured temperature profiles in an approximant of optical floating zone crystal growth

Even though the growth of crystals using optical floating zone furnaces has had an immense scientific impact, the implementation of this method remains more of an art than a science due to the difficulty of obtaining quantitative information about the sample thermal profile during crystal growth. Building on recent work demonstrating that in situ synchrotron studies can be used to map sample rod temperatures during heating, investigations were carried out to better understand how the sample environment affects the sample temperature profile. Through a combination of experimental studies and modeling efforts, it is shown that the environment in the furnace can strongly influence the sample temperature at the lamp focus, the steepness of the vertical temperature gradient, and the timescale required for sample heating and cooling - effects which can combine to produce a strong history-dependence to sample temperature profiles. It is demonstrated that the furnace effects can be effectively captured in thermal models, allowing both the steady-state and time-dependent behavior of the sample to be accurately reproduced with predictive models, and providing a launching point for improved furnace designs that can more readily deliver desired thermal profiles.

36 MATERIALS SCIENCE↗

Automated Coupling of Nanodroplet Sample Preparation with Liquid Chromatography–Mass Spectrometry for High-Throughput Single-Cell Proteomics

Single-cell proteomics can provide critical biological insight into the cellular heterogeneity that is masked by bulk-scale analysis. Here, we have developed a nanoPOTS (nanodroplet processing in one pot for trace samples) platform and demonstrated its broad applicability for single-cell proteomics. However, because of nanoliter-scale sample volumes, the nanoPOTS platform is not compatible with automated LC-MS systems, which significantly limits sample throughput and robustness. To address this challenge, we have developed a nanoPOTS autosampler allowing fully automated sample injection from nanowells to LC-MS systems. We also developed a sample drying, extraction, and loading workflow to enable reproducible and reliable sample injection. The sequential analysis of 20 samples containing 10 ng tryptic peptides demonstrated high reproducibility with correlation coefficients of >0.995 between any two samples. The nanoPOTS autosampler can provide analysis throughput of 9.6, 16, and 24 single cells per day using 120, 60, and 30 min LC gradients, respectively. As a demonstration for single-cell proteomics, the autosampler was first applied to profiling protein expression in single MCF10A cells using a label-free approach. At a throughput of 24 single cells per day, an average of 256 proteins was identified from each cell and the number was increased to 731 when the Match Between Runs algorithm of MaxQuant was used. Using a multiplexed isobaric labeling approach (TMT-11plex), ~77 single cells could be analyzed per day. We analyzed 152 cells from three acute myeloid leukemia cell lines, resulting in a total of 2558 identified proteins with 1465 proteins quantifiable (70% valid values) across the 152 cells. These data showed quantitative single-cell proteomics can cluster cells to distinct groups and reveal functionally distinct differences.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Femtosecond Laser Desorption Postionization MS vs ToF-SIMS Imaging for Uncovering Biomarkers Buried in Geological Samples

The study of lipid molecular fossils by traditional biomarker analysis requires bulk sample crushing, followed by solvent extraction, and then the analysis of the extract by gas chromatography-mass spectrometry (GC–MS). This traditional analysis mixes all organic compounds in the sample regardless of their origins, with a loss of information on the spatial distribution of organic molecules within the sample. These shortcomings can be overcome using the chemical mapping of intact samples. Spectroscopic techniques such as UV fluorescence or Raman spectroscopy, laser ablation inductively coupled plasma mass spectrometry, and time-of-flight secondary ion mass spectrometry (ToF-SIMS) are among those elemental and molecular mapping techniques. This study employed femtosecond (fs) laser ablation combined with single-photon ionization, a method called fs-laser desorption postionization mass spectrometry (fs-LDPI-MS). In this work, a pulsed ~75 fs, 800 nm laser was used to ablate the geological sample, which was then photoionized after a few microseconds by a pulsed 7.9 eV vacuum ultraviolet laser. An organic carbon-rich geological sample was used for this study to map hydrocarbon biomarkers in sediments that were previously studied by GC–MS. The petrography of this sample was examined by optical and fluorescence microscopy. It is demonstrated here that fs-LDPI-MS combined with petrography for multimodal imaging can expose buried compounds within the sample via in situ layer removal. When used in conjunction with traditional organic geochemical analysis, this method has the potential to determine the spatial distribution of organic biomarkers in geological material. Finally, fs-LDPI-MS imaging data are compared with ToF-SIMS imaging that is commonly used for such studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Block Design with Common Reference Samples Enables Robust Large-Scale Label-Free Quantitative Proteome Profiling

Label-free quantitative proteomics has become an increasingly popular tool for profiling global protein abundances. However, one major weakness is the potential performance drift of the LC-MS platform over time, which in turn limits its utility for analyzing large-scale sample sets. To address this, in this work we introduce an experimental and data analysis scheme based on a block-design with common controls within each block for enabling LC-MS-based large-scale label-free quantification. In this scheme, a large number of samples (e.g., >100 samples) are analyzed in smaller, and more manageable blocks, minimizing instrument drift and variability within a block. Furthermore, each designated block also contains common controls (or reference) samples for normalization within and across blocks. We demonstrated the effectiveness of this method by profiling the proteome response of human macrophage THP-1 cells to 11 engineered nanomaterials (ENMs) at two different doses. A total of 116 samples were analyzed in six blocks, yielding an average coverage of 4500 proteins per sample. The data revealed consistent quantification of proteins across all six blocks, as shown by highly stable quantification of house-keeping proteins in all samples and high levels of quantification correlation among samples from different blocks. The data also demonstrated that label-free quantification is robust and accurate enough to quantify even very subtle abundance changes as well as large fold-changes without potential ratio compression as often encountered with isobaric labeling. Our streamlined workflow is easy to implement and can be readily adapted to other large cohort studies for reproducible label-free proteome quantification.

59 BASIC BIOLOGICAL SCIENCES↗

Nanopipettes: probes for local sample analysis

Nanopipettes (pipettes with diameters <1 μm) were explored as pressure-driven fluid manipulation tools for sampling nanoliter volumes of fluids. The fundamental behavior of fluids confined in the narrow channels of the nanopipette shank was studied to optimize sampling volume and probe geometry. This method was utilized to collect nanoliter volumes (<10 nL) of sample from single Allium cepa cells and live Drosophila melanogaster first instar larvae. Matrix assisted laser desorption/ionization-mass spectrometry (MALDI-MS) was utilized to characterize the collected sample. The use of nanopipettes for surface sampling of mouse brain tissue sections was also explored. Lipid analyses were performed on mouse brain tissues with spatial resolution of sampling as small as 50 μm. Nanopipettes were shown to be a versatile tool that will find further application in studies of sample heterogeneity and population analysis for a wide range of samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct and rapid uranium isotopic analysis of environmental sample swipes via microextraction – LS-APGD/Orbitrap mass spectrometry

Accurate and precise isotopic analysis of actinides collected on environmental sample swipes from within nuclear facilities is an important safeguarding measure for detecting undeclared materials and activities. Traditional isotope ratio (IR) analysis of actinides using a bulk digestion approach can be laborious and time-consuming. Recently, direct analysis of environmental swipe samples using a microextraction approach has been explored as an alternative to conventional bulk digestion methods. The present study further evaluates this approach for accurate and precise isotopic analysis of uranium (U) in cotton swipe samples using the liquid sampling-atmospheric pressure glow discharge (LS-APGD)/Orbitrap-FTMS Booster detection system. The instrumental parameters were optimized, and quantitative capabilities were demonstrated through excellent linearity (R2 = 0.99) across a deposited mass range of 1 to 500 ng, with a limit of detection of 90 pg (in a 2 × 4 mm region) for total U; well below typical U concentrations (ng–mg range) in environmental sample swipes. The 235U/238U ratio showed excellent accuracy (−0.3% relative difference from the certificate value), with ∼20× improvement over previous microextraction-Orbitrap methods. Precision (∼1% relative standard deviation) was also greatly enhanced by ∼5×. This study also demonstrates that figures of merit achieved with neat U solution were not highly degraded when various external interfering elements/matrices were introduced. Finally, the developed method was successfully applied to analyze practical swipe samples representative of laboratory and outdoor environments. The presented figures of merit and applicability to practical samples further validate the capability of the platform for rapid analysis (<7 minutes) of environmental swipe samples.

Shrestha, Suraj [Clemson University, SC]↗

Qualitative analysis of Pb liquid sample using laser-induced breakdown spectroscopy (LIBS)

Qualitative analysis of liquid sample containing 1,000 ppm of Pb was performed by using LIBS technique. In order to avoid splashing off of the liquid sample during laser irradiation, a sample pretreatment was done, namely the liquid sample was absorbed by using commercial available stomach medicine. Two kinds of absorbent materials were chosen in this experiment, first containing 125 mg activated carbon and second 600 mg activated attapulgite. These absorbent materials were used since carbon sample gives better absorption of infrared laser irradiation used in this experiment. In order to characterize the absorption process, three treatments were conducted in this experiment; first, without heating the sample but varying the absorption time before laser irradiation; second by varying the heating temperature after certain time of absorption process and third by varying the temperature only. The maximum emission intensity of Pb I 405.7 nm was found in the second treatment of heating the sample till 85°C after 30 minutes absorption of the liquid sample in both absorbent materials.

36 MATERIALS SCIENCE↗

Case depth verification of hardened samples with Barkhausen noise sweeps

An interesting topic of recent Barkhausen noise (BN) method studies is the application of the method to case depth evaluation of hardened components. The utilization of BN method for this purpose is based on the difference in the magnetic properties between the hardened case and the soft core. Thus, the detection of case depth with BN can be achieved. The measurements typically have been carried out by using low magnetizing frequencies which have deeper penetration to the ferromagnetic samples than the conventional BN measurement. However, the penetration depth is limited due to eddy current damping of the signal. We introduce here a newly found sweep measurement concept for the case depth evaluation. In this study sweep measurements were carried out with various magnetizing frequencies and magnetizing voltages to detect the effect of different frequency and voltage and their correspondence to the actual case depth values verified from destructive characterization. Also a BN measurement device that has an implemented sweep analysis option was utilised. The samples were either induction or case-hardened samples and sample geometry contained both rod samples and gear axle samples with different case depth values. Samples were also further characterized with Xray diffraction to study the residual stress state of the surface. The detailed data processing revealed that also other calculated features than the maximum slope division of the 1st derivative of the BN signal could hold the information about the case depth value of the samples. The sweep method was able to arrange the axles into correct order according to the case depth value even though the axles were used.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study on effect of annealing conditions on structural, magnetic and superconducting properties of MgB{sub 2} bulk samples

Effect of annealing conditions on structural, magnetic and superconducting properties of Magnesium Diboride (MgB{sub 2}) bulk superconductor samples prepared by solid state route method are compared. The samples are made by taking Magnesium and Boron powders in stoichiometric ratio, grounded well and pelletized at pressure of about 10Tonnes. These pellets are annealed in both Argon and vacuum environment separately up to 800°c for two hours. Both the samples show clear superconducting transition at Tc ∼ 38 k. This is further conformed by AC/DC magnetization (M-T), Resistivity [ρ (T, H)] measurements under magnetic field up to 14 Tesla as well. Rietveld refinement of X-ray diffraction of both samples conformed the MgB{sub 2} phase formation with P6/mmm space group symmetry. Scanning Electron Microscopy images of the surface revile more agglomeration of grains in case of Argon annealed samples. This result in more critical current density (J{sub c}) of Argon annealed samples than vacuum annealed one calculated from Bean's critical state model. This high Jc is explained in terms of more inter grain connectivity for Argon annealed sample than vacuum annealed sample.

36 MATERIALS SCIENCE↗

A whole-path importance-sampling scheme for Feynman path integral calculations of absolute partition functions and free energies

Using Feynman path integrals, a molecular partition function can be written as a double integral with the inner integral involving all closed paths centered at a given molecular configuration, and the outer integral involving all possible molecular configurations. In previous work employing Monte Carlo methods to evaluate such partition functions, we presented schemes for importance sampling and stratification in the molecular configurations that constitute the path centroids, but we relied on free-particle paths for sampling the path integrals. At low temperatures, the path sampling is expensive because the paths can travel far from the centroid configuration. In this paper, we now present a scheme for importance sampling of whole Feynman paths based on harmonic information from an instantaneous normal mode calculation at the centroid configuration, which we refer to as harmonically guided whole-path importance sampling (WPIS). We obtain paths conforming to our chosen importance function by rejection sampling from a distribution of free-particle paths. Sample calculations on CH 4 demonstrate that at a temperature of 200 K, about 99.9% of the free-particle paths can be rejected without integration, and at 300 K, about 98% can be rejected. Finally, we also show that it is typically possible to reduce the overhead associated with the WPIS scheme by sampling the paths using a significantly lower-order path discretization than that which is needed to converge the partition function.

74 ATOMIC AND MOLECULAR PHYSICS↗

Quantitative comparison of adaptive sampling methods for protein dynamics

Adaptive sampling methods, often used in combination with Markov state models, are becoming increasingly popular for speeding up rare events in simulation such as molecular dynamics (MD) without biasing the system dynamics. Several adaptive sampling strategies have been proposed, but it is not clear which methods perform better for different physical systems. Here, we present a systematic evaluation of selected adaptive sampling strategies on a wide selection of fast folding proteins. The adaptive sampling strategies were emulated using models constructed on already existing MD trajectories. We provide theoretical limits for the sampling speed-up and compare the performance of different strategies with and without using some a priori knowledge of the system. The results show that for different goals, different adaptive sampling strategies are optimal. In order to sample slow dynamical processes such as protein folding without a priori knowledge of the system, a strategy based on the identification of a set of metastable regions is consistently the most efficient, while a strategy based on the identification of microstates performs better if the goal is to explore newer regions of the conformational space. Interestingly, the maximum speed-up achievable for the adaptive sampling of slow processes increases for proteins with longer folding times, encouraging the application of these methods for the characterization of slower processes, beyond the fast-folding proteins considered here.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating the effect of sample type on American alligator ( Alligator mississippiensis ) analyte values in a point-of-care blood analyser

The assessment of wildlife health has been enhanced by the ability of point-of-care (POC) blood analysers to provide biochemical analyses of non-domesticated animals in the field. However, environmental limitations (e.g. temperature, atmospheric humidity and rain) and lack of reference values may inhibit researchers from using such a device with certain wildlife species. Evaluating the use of alternative sample types, such as plasma, in a POC device may afford researchers the opportunity to delay sample analysis and the ability to use banked samples. In this study, we examined fresh whole blood, fresh plasma and frozen plasma (sample type) pH, partial pressure of carbon dioxide (PCO 2 ), bicarbonate (HCO 3 ₋), total carbon dioxide (TCO 2 ), base excess (BE), partial pressure of oxygen (PO 2 ), oxygen saturation (sO 2 ) and lactate concentrations in 23 juvenile American alligators (Alligator mississippiensis) using an i-STAT CG4+ cartridge. Our results indicate that sample type had no effect on lactate concentration values (F 2,65 = 0.37, P = 0.963), suggesting that the i-STAT analyser can be used reliably to quantify lactate concentrations in fresh and frozen plasma samples. In contrast, the other seven blood parameters measured by the CG4+ cartridge were significantly affected by sample type. In conclusion, we were able to collect blood samples from all alligators within 2 min of capture to establish preliminary reference ranges for juvenile alligators based on values obtained using fresh whole blood.

60 APPLIED LIFE SCIENCES↗

Application-Specific Graph Sampling for Frequent Subgraph Mining and Community Detection

Graph mining is an important data analysis methodology, but struggles as the input graph size increases. The scalability and usability challenges posed by such large graphs make it imperative to sample the input graph and reduce its size. The critical challenge in sampling is to identify the appropriate algorithm to insure the resulting analysis does not suffer heavily from the data reduction. Predicting the expected performance degradation for a given graph and sampling algorithm is also useful. In this paper, we present different sampling approaches for graph mining applications such as Frequent Subgrpah Mining (FSM), and Community Detection (CD). We explore graph metrics such as PageRank, Triangles, and Diversity to sample a graph and conclude that for heterogeneous graphs Triangles and Diversity perform better than degree based metrics. We also present two new sampling variations for targeted graph mining applications. We present empirical results to show that knowledge of the target application, along with input graph properties can be used to select the best sampling algorithm. We also conclude that performance degradation is an abrupt, rather than gradual phenomena, as the sample size decreases. We present the empirical results to show that the performance degradation follows a logistic function.

Purohit, Sumit↗

In Vitro Thrombogenicity Testing of Biomaterials in a Dynamic Flow Loop: Effects of Length and Quantity of Test Samples

Abstract The results of in vitro dynamic thrombogenicity testing of biomaterials and medical devices can be significantly impacted by test conditions. To develop and standardize a robust dynamic in vitro thrombogenicity tool, the key test parameters need to be appropriately evaluated and optimized. We used a flow loop test system previously developed in our laboratory to investigate the effects of sample length and the number of samples per test loop on the thrombogenicity results. Porcine blood heparinized to a donor-specific target concentration was recirculated at room temperature through polyvinyl chloride (PVC) tubing loops containing test materials for 1 h at 200 mL/min. Four test materials (polytetrafluoroethylene (PTFE), latex, PVC, and silicone) with various thrombotic potentials in two sample lengths (12 and 18 cm) were examined. For the 12-cm long materials, two different test configurations (one and two samples per loop) were compared. Thrombogenicity was assessed through percent thrombus surface coverage, thrombus weight, and platelet count reduction in the blood. The test system was able to effectively differentiate the thrombogenicity profile of the materials (latex > silicone > PVC ≥ PTFE) at all test configurations. Increasing test sample length by 50% did not significantly impact the test results as both 12 and 18 cm sample lengths were shown to equally differentiate thrombotic potentials between the materials. The addition of a second test sample to each loop did not increase the test sensitivity and may produce confounding results, and thus a single test sample per loop is recommended.

Engineering↗

Ultra-trace determination of Strontium-90 in environmental soil samples from Qatar by collision/reaction cell-inductively coupled plasma mass spectrometry (CRC-ICP-MS/MS)

Because of the very low level of {sup 90}Sr in the environmental soil samples and its determination by beta counting may take several weeks, we developed a procedure for ultra-trace determination of {sup 90}Sr using collision reaction cell-inductively coupled plasma tandem mass spectrometry (CRC-ICP-MS/MS, Agilent 8800). Soil samples were dried at 105 deg. C and then heated in a furnace at 550 deg. C to remove any organics present. 500 g of each soil samples were aliquoted into 2000 ml glass beakers. Each Soils samples were soaked in 2 ppm Sr solution carrier to allow determination of chemical yield. The solid to liquid ratio was 1:1. Finally the soil samples were dried at 105 deg. C. Five hundred milliliters concentrated nitric acid and 250 ml hydrochloric acid volumes were added on 500 g soil samples. The samples were digested on hot plate at 80 deg. C to prevent spraying with continuous manual mixing. The leachate solution was separated. The solids were rinsed with 500 ml deionized water, warmed on a hot plate and the leachate plus previous leachate were filtered and the total volume was reduced to 500 ml by evaporation. Final leachate volume was transferred to a centrifuge tubes. The centrifuge tubes were centrifuged at 3,500 rpm for 10 min. The leachate was transferred to a 1 L beaker and heated on a hot plate to evaporate the leachate to dryness. The reside was re-dissolved in 100 ml of 2% HNO{sub 3} and reduced by evaporation to 10 mL. The solution was measured directly by CRC-ICP-MS/MS by setting the first quadruple analyzer to m/z 90 and introducing oxygen gas into the reaction cell for elimination isobar interference from zirconium-90. The method was validated by measurements of standard reference materials and applied on environmental soil samples. The overall time requirement for the measurement of strontium-90 by CRC-ICP-MS/MS is 2 days, significantly shorter than any radioanalytical protocol currently available. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗