Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reference systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Utilization of municipal wastewater for cooling in thermoelectric power plants: Evaluation of the combined cost of makeup water treatment and increased condenser fouling

A methodology is presented to calculate the total combined cost (TCC) of water sourcing, water treatment and condenser fouling in the recirculating cooling systems of thermoelectric power plants. The methodology is employed to evaluate the economic viability of using treated municipal wastewater (MWW) to replace the use of freshwater as makeup water to power plant cooling systems. Cost analyses are presented for a reference power plant and five different tertiary treatment scenarios to reduce the scaling tendencies of MWW. Results indicate that a 550 MW sub-critical coal fired power plant with a makeup water requirement of 29.3 ML/day has a TCC of $3.0 - 3.2 million/yr associated with the use of treated MWW for cooling. (All costs USD 2009). This translates to a freshwater conservation cost of $0.29/kL, which is considerably lower than that of dry air cooling technology, $1.5/kL, as well as the 2020 conservation cost target set by the U.S. Department of Energy, $0.74/kL. Results also show that if the available price of freshwater exceeds that of secondary-treated MWW by more than $0.13-0.14/kL, it can be economically advantageous to purchase secondary MWW and treat it for utilization in the recirculating cooling system of a thermoelectric power plant.

20 FOSSIL-FUELED POWER PLANTS↗

SU-G-JeP4-04: Commissioning and Acceptance Testing of Optical Surface Monitoring System On TrueBEAM STx as Per Task Group 147

Purpose: Optical Surface Monitoring system (OSMS) have been recently introduced by Varian for initial patient positioning and real-time monitoring during complex radiotherapy treatment. The purpose of this work was to implement TG 147 with OSMS. Methods: Recently we installed OSMS first of its kind in India on trueBEAM STx at our Institue. The OSMS is composed of a three cameras ceiling mounted and a Workstation. The following tests were performed to validate the system a. Calibration b. System reproducibility and drift c. Static localization displacement accuracy and d. Dynamic radiation gating delivery. The Calibration procedure consists of Daily,Monthly and MV Radiation Isocenter Calibration. The reproducibility of system was tested by monitoring the varian gating phantom test pattern for at least 120 min. Each recorded pattern was registered to the reference surface to calculate the required couch adjustment. To measure the static localization displacement accuracy of the system to detect and quantify patient shift relative to a reference image,we compared the shift detected by the surface imaging system with known couch transitions in a phantom study. The phantom was set in a motion and the radiation beam was holded by changing the threshold in the software for different clinical setups to test the dynamic radiation gating capability. Results: Daily calibration was within ±0.5 mm. The MV radiation isocentre with respect to cameras was less than 1 mm in translational axis and less than 0.5° for rotational axis. The reproducibility was found to be 0.4 mm. The maximum static displacement accuracy was 0.75 mm for the three translational axis, and less than 0.5° for rotational axis. The system was able to hold the beam with a minimum threshold of 1 mm. Conclusion: A quality assurance process has been developed as per TG 147 for the clinical implementation of an OSMS in radiation therapy.

60 APPLIED LIFE SCIENCES↗

Agrivoltaic Grazing Systems for a Sustainable Future: A Multi‐Disciplinary Review & Gap Analysis

Solar photovoltaics (PV) is the fastest growing source of electricity in the world, however, its expansion has raised concerns about the displacement of agriculture and the degradation of rangeland ecosystems. This has prompted research and development of multi-land-use systems that co-prioritize energy production alongside agriculture, commonly referred to as agrivoltaics. Currently, agrivoltaic grazing (also called solar grazing) is one of the most common forms of these systems. However, peer-reviewed research on these systems is limited. This review synthesizes research on agrivoltaic grazing systems, drawing upon literature addressing agrivoltaics broadly and considering relevant literature in adjacent fields of study. Based on this review, we identify six key gaps and priority directions for future research. These include foundational fieldwork to characterize the layered ecological impacts of solar PV and grazing and understand PV-livestock integration from both an animal welfare and a PV infrastructure perspective. This will facilitate the development of biogeochemical and economic models that improve our predictive capacity and ability to compare system designs. We also identify gaps in understanding the human aspects of these systems and emphasize the importance of utilizing collaborative research methods and increasing research on the social dimensions of agrivoltaic grazing systems.

14 SOLAR ENERGY↗

Small fields output factors measurements and correction factors determination for several detectors for a CyberKnife{sup Registered-Sign} and linear accelerators equipped with microMLC and circular cones

Purpose: The use of small photon fields is now an established practice in stereotactic radiosurgery and radiotherapy. However, due to a lack of lateral electron equilibrium and high dose gradients, it is difficult to accurately measure the dosimetric quantities required for the commissioning of such systems. Moreover, there is still no metrological dosimetric reference for this kind of beam today. In this context, the first objective of this work was to determine and to compare small fields output factors (OF) measured with different types of active detectors and passive dosimeters for three types of facilities: a CyberKnife{sup Registered-Sign} system, a dedicated medical linear accelerator (Novalis) equipped with m3 microMLC and circular cones, and an adaptive medical linear accelerator (Clinac 2100) equipped with an additional m3 microMLC. The second one was to determine the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors introduced in a recently proposed small field dosimetry formalism for different active detectors.Methods: Small field sizes were defined either by microMLC down to 6 Multiplication-Sign 6 mm{sup 2} or by circular cones down to 4 mm in diameter. OF measurements were performed with several commercially available active detectors dedicated to measurements in small fields (high resolution diodes: IBA SFD, Sun Nuclear EDGE, PTW 60016, PTW 60017; ionizing chambers: PTW 31014 PinPoint chamber, PTW 31018 microLion liquid chamber, and PTW 60003 natural diamond). Two types of passive dosimeters were used: LiF microcubes and EBT2 radiochromic films.Results: Significant differences between the results obtained by several dosimetric systems were observed, particularly for the smallest field size for which the difference in the measured OF reaches more than 20%. For passive dosimeters, an excellent agreement was observed (better than 2%) between EBT2 and LiF microcubes for all OF measurements. Moreover, it has been shown that these passive dosimeters do not require correction factors and can then be used as reference dosimeters. Correction factors for the active detectors have then been determined from the mean experimental OF measured by the passive dosimeters.Conclusions: Four sets of correction factors needed to apply the new small field dosimetry formalism are provided for several active detectors. A protocol for small photon beams OF determination based on passive dosimeters measurements has been recently proposed to French radiotherapy treatment centers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Precision surface measurement in a vacuum

Methods and related equipment for dynamic on-axis in-situ interferometry where the reference surface is positioned in an vacuum chamber. The systems use a wavelength shifting, or a phase shifting interferometer that allows the freedom to eliminate the need to step the cavity length physically with the reference surface, allowing the reference surface to be placed inside the vacuum chamber.

Conley, Raymond P.↗

Polishing the Gold Standard: The Role of Orbital Choice in CCSD(T) Vibrational Frequency Prediction

While CCSD(T) with spin-restricted Hartree-Fock (RHF) orbitals has long been lauded for its ability to accurately describe closed-shell interactions, the performance of CCSD(T) on open-shell species is much more erratic, especially when using a spin-unrestricted HF (UHF) reference. Previous studies have shown improved treatment of open-shell systems when a non-HF set of molecular orbitals, like Brueckner or Kohn-Sham density functional theory (DFT) orbitals, is used as a reference. Inspired by the success of regularized orbital-optimized second-order Møller-Plesset perturbation theory (κ-OOMP2) orbitals as reference orbitals for MP3, we investigate the use of κ-OOMP2 orbitals and various DFT orbitals as reference orbitals for CCSD(T) calculations of the corrected ground-state harmonic vibrational frequencies of a set of 36 closed-shell (29 neutrals, 6 cations, 1 anion) and 59 open-shell diatomic species (38 neutrals, 15 cations, 6 anions). The aug-cc-pwCVTZ basis set is used for all calculations. The use of κ-OOMP2 orbitals in this context alleviates difficult cases observed for both UHF orbitals and OOMP2 orbitals. Removing two multireference systems and 12 systems with ambiguous experimental data leaves a pruned data set. Overall performance on the pruned data set highlights CCSD(T) with a B97 orbital reference (CCSD(T):B97), CCSD(T) with a κ-OOMP2 orbital reference (CCSD(T):κ-OOMP2), and CCSD(T) with a B97M-rV orbital reference (CCSD(T):B97M-rV) with RMSDs of 8.48 cm -1 , and 8.50 cm -1 , and 8.75 cm -1 respectively, outperforming CCSD(T):UHF by nearly a factor of 5. Moreover, the performance on the closed- and open-shell subsets shows these methods are able to treat open-shell and closed-shell systems with comparable accuracy and robustness. CCSD(T) with RHF orbitals is seen to improve upon UHF for the closed-shell species, while spatial symmetry breaking in a number of restricted open-shell HF (ROHF) references leads CCSD(T) with ROHF reference orbitals to exhibit the poorest statistical performance of all methods surveyed for open-shell species. The use of κ-OOMP2 orbitals has also proven useful in diagnosing multireference character that can hinder the reliability of CCSD(T).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of Mutual Awareness in Analog vs. Digital Control Rooms

Control rooms in nuclear power plants are complex, collaborative working environments rife with potential for human error. As control rooms evolve from analog to digital interface environments, crew communication strategies must change as well. Operators in the analog control room operate the plant and communicate with each other with the help of control boards with large control panels, meters, and switches. Reactor operators could choose a particular set of controls on the particular control board which corresponds to the part of the system of interest. Visual display units (VDU), which became a fixture in the control rooms with the shift to digital human-machine interfaces (HMI), bring benefits for safety and flexibility combining information from various sources. With the increase in automation and the use of digital HMIs operators received their personal sitting workstations where they are able to navigate and operate the plant. The amount of information increased as well as the complexity of monitoring and analyzing the system states. Also computerized systems cause operators to get absorbed by their personal screens and reduce interaction between the crew members. Therefore, the collaboration and coordination of task demands requires vigilance and mutual awareness. The level of automation has an influence on the level of mutual awareness experienced by operators in the control rooms. Teams function to carry out highly interdependent tasks, requiring synthesis and sharing of information to achieve common goals. Improving the performance of the team necessitates the operators to focus on the system, the surrounding environment, and situational awareness about the system states. Collaboration of team members is critical when employing the digital operating systems as the acute awareness of the overall progress of the group and individual activities of the operators drives the team to the desired end-states of the plant operations. Out-of-the loop (OOTL) performance problems can be referred to as the lack of supervisory control, system monitoring, and information processing in the digital HMIs. Under some circumstances Senior Reactor Operators (SRO) struggle to follow the actions of other Reactor Operators (RO) because with the new digital interfaces SROs lose track of how the procedures are carried out by ROs, which results in the loss of three way communication. Mutual awareness plays a significant role in keeping the SROs in the loop of plant operations. This paper will investigate, through literature review and expert interviews, the impact and human errors attributed to the increasing complexity of new digital main control rooms. Comparison of the new digital interfaces with the analog interfaces in nuclear power plants has the potential to shed light on increasing mutual awareness and three way communications between the SROs and ROs. Further, identification of the human errors and human actions can provide beneficial information, suggesting significant and critical improvements that can be implemented in the main control rooms to increase safety and reliability of new technology. Additionally, insights on mutual awareness for analog vs. digital control rooms can serve to improve human reliability.

99 GENERAL AND MISCELLANEOUS↗

Method for Continuous Monitoring of Electrospray Ion Formation

A method for continuously monitoring the performance of electrospray ionization without the addition of hardware or chemistry to the system is demonstrated. In the method, which we refer to as SprayDx, cluster ions with solvent vapor natively formed by electrospray are followed throughout the collection of liquid chromatography–selected reaction monitoring data. The cluster ion extracted ion chromatograms report on the consistency of the ion formation and detection system. The data collected by the SprayDx method resemble the data collected for postcolumn infusion of analyte. The response of the cluster ions monitored reports on changes in the physical parameters of the ion source such as voltage and gas flow. SprayDx is also observed to report on ion suppression in a fashion very similar to a postcolumn infusion of analyte. We anticipate the method finding utility as a continuous readout on the performance of electrospray and other atmospheric pressure ionization processes. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computational scheme for burnup credit applied to long term waste disposal - 14448

The application of burnup credit (BUC) to criticality safety evaluations (CSE) of geological repositories for long term disposal of spent nuclear fuel (SNF) is under consideration in Switzerland. Therefore, in collaboration with the national waste management organization, PSI is conducting research towards the development of a BUC methodology tailored for Swiss specific applications. As part of this research, a computational sequence from the in-core burnup phase, through the interim storage, until final disposal is being established. The tools selected for this methodology, referred to as BUCSS-R (Burnup Credit System for Swiss reactors and Repositories), are CASMO for the in-core fuel depletion, the decay module of SERPENT for the decay calculations, and MCNP for the criticality calculations. In connection to BUCSS-R, a computational interface to validated reference core models of the Swiss reactors is being developed. The purpose is to apply reconstructed depletion histories based on real core operation conditions with CASMO assembly calculations, to transfer the pin wise nuclide compositions at discharge to the subsequent SERPENT decay calculations, and afterwards to the final MCNP criticality calculations. An objective of this paper is to present the elements of the BUCSS-R methodology, and to show a first application to so-called bounding analyses of a preliminary Swiss disposal canister design loaded with fuel assembly types operated in a Swiss PWR reactor. The rationale for these bounding analyses is that before starting the integration of methodologies for bias and uncertainty quantifications, the span of the k-eff variation between fresh and burnt fuel loadings should first be quantified in a realistic manner. The obtained results are reported in this paper together with studies performed in order to evaluate the effects from burnup levels and nuclides credit at flooded conditions on the k-eff values. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Real-Time High-Accuracy Digital Wireless Time, Frequency, and Phase Calibration for Coherent Distributed Antenna Arrays

his work presents a fully-digital high-accuracy real-time calibration procedure for frequency and time alignment of open-loop wirelessly coordinated coherent distributed antenna array (CDA) modems, enabling radio frequency (RF) phase coherence of spatially separated commercial off-the-shelf (COTS) software-defined radios (SDRs) without cables or external references such as the global navigation satellite system (GNSS). Building on previous work using high-accuracy spectrally-sparse time of arrival (ToA) waveforms and a multistep ToA refinement process, a high-accuracy two-way time transfer (TWTT)-based time–frequency coordination approach is demonstrated. Due to the two-way nature of the high-accuracy TWTT approach, the time and frequency estimates are Doppler and multipath tolerant, so long as the channel is reciprocal over the synchronization epoch. This technique is experimentally verified using COTS SDRs in a lab environment in static and dynamic scenarios and with significant multipath scatterers. Time, frequency, and phase stability were evaluated by beamforming over coaxial cables to an oscilloscope which achieved time and phase precisions of ~60– 70 ps , with median coherent gains above 99% using optimized coordination parameters, and a beamforming frequency root-mean-square error (RMSE) of 3.73 ppb in a dynamic scenario. Finally, experiments were conducted to compare the performance of this technique with previous works using an analog continuous-wave two-tone (CWTT) frequency reference technique in both static and dynamic settings.

Clock synchronization↗

Avista Turner Energy Storage System: Assessment of Battery Technical Performance

This report investigates the technical performance of the 1 MW, 3.2 MWh advanced vanadium flow battery energy storage system (FBESS), consisting of two 0.5 MW, 1.6 MWh strings, based on a number of reference performance and use case tests. The FBESS is located on the utility 12 kV distribution system, between the Turner Substation and SEL’s manufacturing facility in Pullman, Washington. Reference performance tests (RPTs) were intended to assess the general technical capability of the FBESS (e.g., stored energy capacity, ramp rate performance, ability to track varying charge/discharge commands, direct current (DC) battery internal resistance). Use case tests were used to examine the performance of the FBESS while engaged in specific grid services (e.g., arbitrage, frequency regulation, balancing, volt ampere reactive (var) support, dynamic peak shaving). The project determined performance metrics that are important for understanding FBESS performance when subjected to field operation for achieving economic benefits from measurements and/or calculations. These metrics were: • RTE with and without rest, with and without auxiliary loads • Auxiliary power consumption • Reference signal tracking • Temperature excursions beyond normal operating range • Parasitic power loss unaccounted by auxiliary load during rest, and • State of charge (SOC) excursions beyond normal operating range. These RPT and use case performance metrics were analyzed using recorded test results. In addition, the results and lessons presented are also beneficial for any task or effort that needs technical assessment on similar and different types of FBESS, and BESS in general, based on technical specifications and/or field deployment results, since the assessment methodology remains the same.

25 ENERGY STORAGE↗

Vehicle Automation Benefits and Challenges for Passenger Transport System Beyond Automated Driving

The National Renewable Energy Laboratory has been researching the implementation of fully automated passenger transport systems to be operated within dense urban settings, referred to as Automated Mobility Districts, based on roadway vehicle automation as opposed to track or train-based automation. This research, now in its third phase, is presently addressing the full spectrum of benefits and challenges of full automation of passenger transport systems with respect to fleet electrification and the associated multimodal, large fleet operational management, benefits beyond simply automating the driving tasks. The focal points summarized in the paper and presentation address the benefit-analysis of fleet automation to address added complexities imposed on the multi-fleet operational management when there is a simultaneous implementation of an on-demand service mode that connects with and optimizes the effectiveness of legacy transit systems and new sub-regional autonomous vehicle fleets, with specific emphasis on enhanced ability to better meet peak ridership demand. The research also begins to address challenges in operations arising from lack of personnel present to handle unexpected customer and system needs. Combined, this research articulates vehicle automation benefits and challenges beyond simply automating the driving tasks, addressing additional operational benefits automation provides to address the added complexities imposed by electrification and on-demand modes of operation.

33 ADVANCED PROPULSION SYSTEMS↗

Beam Polarization at the ILC: the Physics Impact and the Accelerator Solutions

In this contribution accelerator solutions for polarized beams and their impact on physics measurements are discussed. Focus are physics requirements for precision polarimetry near the interaction point and their realization with polarized sources. Based on the ILC baseline programme as described in the Reference Design Report (RDR), recent developments are discussed and evaluated taking into account physics runs at beam energies between 100 GeV and 250 GeV, as well as calibration runs on the Z-pole and options as the 1TeV upgrade and GigaZ. The studies, talks and discussions presented at this conference demonstrated that beam polarization and its measurement are crucial for the physics success of any future linear collider. To achieve the required precision it is absolutely decisive to employ multiple devices for testing and controlling the systematic uncertainties of each polarimeter. The polarimetry methods for the ILC are complementary: with the upstream polarimeter the measurements are performed in a clean environment, they are fast and allow to monitor time-dependent variations of polarization. The polarimeter downstream the IP will measure the disrupted beam resulting in high background and much lower statistics, but it allows access to the depolarization at the IP. Cross checks between the polarimeter results give redundancy and inter-calibration which is essential for high precision measurements. Current plans and issues for polarimeters and also energy spectrometers in the Beam Delivery System of the ILC are summarized in reference [28]. The ILC baseline design allows already from the beginning the operation with polarized electrons and polarized positrons provided the spin rotation and the fast helicity reversal for positrons will be implemented. A reversal of the positron helicity significantly slower than that of electrons is not recommended to not compromise the precision and hence the success of the ILC. Recently to use calibration data at the Z resonance for physics has been discussed. It looks promising but further studies are needed to evaluate and to optimize these measurements. Finally it should be remarked: many studies on different physics processes and scenarios at a future linear collider are done for high luminosities and high energy assuming small and well-known uncertainties. Polarization, especially positron polarization, is often considered as not that important. But in order to interpret data and to reduce ambiguities in the measurements, the polarization of electrons and positrons and their very precise knowledge are essential. The ILC design must offer this from the beginning to be prepared for the physics questions after years of LHC operation.

43 PARTICLE ACCELERATORS↗

Transformational challenge reactor analysis to inform preconceptual core design decisions: Sensitivity study of transient analysis in a hydride-moderated microreactor

The Transformational Challenge Reactor (TCR) program aims to demonstrate a revolutionary design approach enabled by advanced manufacturing and data analytics in the design of nuclear reactors. This article discusses scoping analyses of preconceptual designs to inform TCR design decisions and the evaluation of sensitivities and uncertainties on postulated transient scenarios. The applicability of the systems codes TRACE and RELAP5-3D to TCR transient analysis are examined, and RELAP5-3D models are used to examine the transient response of two candidate core designs at multiple power levels. Then, the uncertainty quantification code RAVEN is used to quantify the effect of several design parameters on reactivity-initiated accident (RIA) progression at hot zero power (HZP) and hot full power (HFP) as well as to assess the impact of uncertainties in transient parameters for the pressurized loss of forced cooling (PLOFC).When results were compared, TRACE and RELAP5-3D showed good agreement in their ability to predict system behavior, but RELAP5-3D calculations were closer to analytical predictions for the RIA. Furthermore, models for a PLOFC accident in two designs (a UO2 and TRISO core) at multiple power levels showed greater temperature margins for the TRISO core at all power levels. Using this information, along with other scoping analyses and constraints, the TCR design team selected a power level of 3 MWth and a TRISO-based core design. For this design RAVEN was applied to vary RIA parameters in RELAP5-3D models at HZP and HFP to understand the effect on figures of merit such as peak power, fuel and coolant temperature, and energy deposition. This sensitivity study found that the inserted reactivity worth was the most important parameter controlling all figures of merit, but for insertion up to 1.5$ no failure of TCR fuel is anticipated. For constant reactivity insertions, the magnitude of the fuel temperature coefficient was found to have the greatest effect on all figures of merit under most circumstances. These results not only demonstrate the anticipated robust safety of the proposed TCR fuel form but also provide a reference for future metal-hydride moderated systems to understand RIA behavior. In the PLOFC, the impact of heat transfer enhancement due to wavy flow channel effects dominated the variance in peak temperatures, and variations in heat exchanger elevation provided the greatest control on natural circulation flow rate. Additionally, no fuel particle failure is anticipated in the PLOFC.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Density functionals combined with van der Waals corrections for graphene adsorbed on layered materials

Standard density functionals like Perdew-Burke-Ernzerhof (PBE) or Strongly Constrained and Appropriately Normed (SCAN) need a correction to account for long-range van der Waals (vdW) interaction. The damped Zaremba-Kohn model (dZK) starts from a formula for the vdW interaction of a distant atom with a solid surface, both with known dielectric properties, damps this formula at short range, and then treats an adsorbed molecule or atomic layer as a collection of renormalized atoms. Here, we extend this model to graphene adsorbed on semiconducting layered materials [bulk graphite and hBN, and multilayer transition metal dichalcogenides (TMD)] by including the C 4 asymptotic term and multiple electrostatic image effects due to the two surfaces of the substrate slabs in the vdW calculations. The resulting SCAN-vdW-dZK and PBE-vdW-dZK give approximately the same results for the systems considered here, in agreement with available reference values. The predicted binding energies are roughly 25% lower than those from SCAN+rVV10 (revised Vydrov and Van Voorhis 2010), and ~15% lower than those from PBE+rVV10. Since SCAN+rVV10 usually overbinds, the predicted binding energies by SCAN-vdW-dZK and PBE-vdW-dZK are expected to be closer to the true values. The predicted equilibrium binding distances from SCAN-vdW-dZK and PBE-vdW-dZK are slightly larger (~ 0.1 Å) than those from SCAN+rVV10, and close to those from SCAN. The binding energy depends upon the number of substrate layers more strongly in vdW-dZK than in rVV10. The C 4 -term contributions can be 40% of the total vdW interactions, and the C 5 term contributes about 10%. The effects of images and the back surfaces of slabs can contribute about 4–10%. The vdW interaction energy power laws from the vdW-dZK model for graphene adsorbed on multilayer MoS 2 show slowly varying decay to the pairwise exponent –4 with increasing separation $\textit{D}$, very similar to those obtained from the random-phase approximation and renormalization group approaches by Ambrosetti et al. Both the PBE-vdW-dZK and SCAN-vdW-dZK give a greater increase in interlayer binding energy when the TMD substrate changes from monolayer to four-layer for the graphene/TMD adsorption systems. This is consistent with the relevant electron-energy-loss spectroscopy experimental results showing increased dielectric response from the substrate with increasing substrate layer number.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A&L Annual Report: Kapton Strength

Exploding Foil Initiator (EFI) systems function by launching a polymer flyer (often referred to as a slapper) at a high explosive (HE) pellet, which is intended to shock-initiate the HE. Flyer characteristics (e.g., shape, planarity, etc.) are extremely important in this respect, governing their ability to initiate the HE. Polymer models currently used in these systems are largely unvalidated, potentially compromising the integrity of magneto-hydrodynamic (MHD) predictions of EFI function. An improved EFI MHD modelling capability is expected to: (1) expedite optimization of EFI-based initiation system design, (2) enable consideration of EFI-related aging and corresponding lifetime predictions, and (3) potentially minimize the number of costly experiments required to certify EFI designs. To address this knowledge gap, several years ago we began a computational project to develop a higher-fidelity model for Kapton, a Polyimide copolymer most commonly employed as the flyer material in EFI devices.

36 MATERIALS SCIENCE↗

Expansion of the Fuel Motion Monitoring System

The Idaho National Laboratory (INL) Transient Reactor Test Facility (TREAT) Fuel Motion Monitoring System (FMMS) is a diagnostic tool used to visualize the movement and location of fuel within the nuclear reactor during transient experiments. TREAT is designed to test the behavior of nuclear fuel under accident conditions, such as a rapid power increase. The TREAT FMMS, also referred to as the “hodoscope” because of the system’s massive steel collimator component, is located on the North beam port of the reactor. While the FMMS system is capable of incorporating a total of 360 sensors, initial refurbishment efforts resulted in a array of 96 fast neutron detectors. This initial array was configured to provide a narrow (2 channels) full-length view of experiment vessels with an extended 4-channel–wide region in the center of the array capable of providing a full view of all initially planned experiments. Planning and efforts to expand the FMMS array began immediately following the restart of TREAT. An additional 96 detectors were evaluated, characterized, and prepared for installation at TREAT during the summer of 2018. Unfortunately, funding reductions forced the project towards a 5-year hiatus. In October of 2023 funding from the Department of Energy’s Nuclear Science User Facilities enabled the expansion to recommence. This report serves to document the activities performed to expand the FMMS detector array to 192 channels in order to provide a broader view of the larger and more sophisticated test capsules currently planned for future irradiation in the TREAT reactor. This expansion also included doubling the data acquisition capability, addressing the new heat load on the system, and synchronizing the time for all digital components.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-I-58: Experiences in Setting Up An Online Fluoroscopy Tracking System in a Large Healthcare System

Purpose: Transitioning from a paper based to an online system for tracking fluoroscopic case information required by state regulation and to conform to NCRP patient dose tracking suggestions. Methods: State regulations require documentation of operator, equipment, and some metric of tube output for fluoroscopy exams. This information was previously collected in paper logs, which was cumbersome and inefficient for the large number of fluoroscopic units across multiple locations within the system. The “tech notes” feature within Siemens’ Syngo workflow RIS was utilized to create an entry form for technologists to input case information, which was sent to a third party vendor for archiving and display though an online web based portal. Results: Over 55k cases were logged in the first year of implementation, with approximately 6,500 cases per month once fully online. A system was built for area managers to oversee and correct data, which has increased the accuracy of inputted values. A high-dose report was built to automatically send notifications when patients exceed trigger levels. In addition to meeting regulatory requirements, the new system allows for larger scale QC in fluoroscopic cases by allowing comparison of data from specific procedures, locations, equipment, and operators so that instances that fall outside of reference levels can be identified for further evaluation. The system has also drastically improved identification of operators without documented equipment specific training. Conclusion: The transition to online fluoroscopy logs has improved efficiency in meeting state regulatory requirements as well as allowed for identification of particular procedures, equipment, and operators in need of additional attention in order to optimize patient and personnel doses, while high dose alerts improve patient care and follow up. Future efforts are focused on incorporating case information from outside of radiology, as well as on automating processes for increased efficiencies.

60 APPLIED LIFE SCIENCES↗