Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power transformers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Novel Power-Hardware-in-the-Loop Interface Method for Grid-Forming Inverter Systems

Power-hardware-in-the-loop (PHIL) simulations of grid-forming (GFM) inverter systems facilitate the testing of drastic scenarios, such as on-grid to off-grid transitions and islanded microgrid operations without a stiff grid. To the authors’ best knowledge, most studies in the literature focus on PHIL simulations for grid-following inverter systems. Only a few studies focus on GFM inverters, and those are challenging and problematic, especially for high-power applications. This article proposes a novel PHIL simulation platform that enables interfacing high-power GFM inverter systems. The paper proposes the concept of a virtual GFM inverter as a part of the proposed PHIL interface. This addition of a virtual GFM inverter in the PHIL interface expands the conventional ideal transformer model (ITM) method and enables it to overcome the issues of instability of existing ITM methods. In the validation stage, a PHIL experiment is conducted on a three-phase, 480-V, 125-kVA GFM inverter system with the proposed interfacing method. The results corroborate that the proposed PHIL simulation method performs well and is stable for GFM inverter systems.

droop control↗

A Novel Power-Hardware-in-the-Loop Interface Method for Grid-forming Inverter Systems: Preprint

Power Hardware-in-the-Loop (PHIL) simulation of grid-forming (GFM) inverter systems facilitates the testing of drastic scenarios like on-grid to off-grid transition, islanded microgrid operation without stiff grid etc. To the authors best knowledge, most of studies in literature are focused on PHIL simulation for grid-following inverter systems and only few studies are focused on GFM inverters and those are challenging and problematic especially for high-power applications. In this article, a novel PHIL simulation platform is proposed that enables interfacing of high-power GFM inverter systems. It proposes the concept of a virtual GFM inverter as a part of the proposed PHIL interface for GFM inverter. This addition of virtual GFM inverter in the PHIL interface expands the conventional Ideal Transformer Model (ITM) method and enables it to overcome the issues of instability of existing ITM methods. In the validation stage, a PHIL experiment is conducted on a 3-phase 480 V, 125 kVA GFM inverter system with proposed interfacing method. The results corroborates the fact that the proposed PHIL simulation method performs well and stable for GFM inverter system.

grid-forming inverters↗

A Smart Silicon Carbide Power Module With Pulse Width Modulation Over Wi-Fi and Wireless Power Transfer-Enabled Gate Driver, Featuring Onboard State of Health Estimator and High-Voltage Scaling Capabilities: Preprint

A wide range of utility applications require controllable switches with features such as high-voltage (HV) blocking and high-current carrying capacity especially at high pulse width modulation (PWM) frequency. Low and medium voltage utility applications such as motor drives and flexible AC transmission systems (FACTS) as well as solid state transformers (SST) could also benefit from a low-cost HV switching module. Wide band gap (WBG) semiconductors such as SiC and GaN MOSFETs are considered to be the present and next generation device choices, although they have their own limitations. For relatively HV applications with demanding thermal management, SiC is still the only choice, and GaN dominates the low voltage regime. This manuscript proposes a new half bridge power MOSFET module that is suitable for conventional H-bridge of multilevel configurations used in HV applications. Constructed from bare SiC dies, this half bridge module takes advantage of (1) optimized MOSFET placement inside the module, (2) customized heat exchanger, manifold and cooling, (3) integrated gate driver module with PWM over wi-fi to eliminate the need for low voltage signals, (4) wireless power transfer (WPT) enabled gate driver and other ancillary circuits, (5) and the option to incorporate an onboard state of health (SOH) estimator module onboard. The entire architecture has been designed and built at National Renewable Energy Laboratory (NREL), Golden, CO.

baseplate design↗

Hierarchical Distributed Optimal Power Flow of HV and MV Distribution Networks With Continuous and Discrete Devices

With large-scale distributed photovoltaics (PVs) being integrated into distribution networks (DNs), coordinated optimal power flow (OPF) of high voltage (HV) and medium voltage (MV) DNs should be investigated to optimally dispatch the distributed PVs and other network devices. Here, this paper presents a hierarchical distributed OPF method for HV and MV DNs with on-load tap changers, reactive power compensators, feeder switches and distributed PVs. A hierarchical master-slave control architecture is applied to implement coordinated OPF of two-layer DNs. The HV master problem and MV subproblems are transformed into mixed-integer convex problems respectively with second order cone programming and LinDistFlow approximation. Since there is no efficient distributed algorithm to solve such OPF models with integer subproblems, a novel distributed algorithm is proposed in this paper to efficiently solve the hierarchical coordinated OPF model with integer subproblems in a distributed manner. In the proposed algorithm, the coordinated OPF model is solved in a branch-and-bound framework, where in each branch node generalized Benders decomposition (GBD) algorithm is applied to decompose the coordinated OPF model into a master problem and relaxed subproblems and solves them iteratively to get optimal solution. The GBD optimal and feasible cutting planes generated in a branch node are proved to be valid for its descendants. Moreover, three acceleration techniques are introduced into the proposed algorithm to improve computational efficiency. Finally, the effectiveness and accuracy of the proposed method are verified via simulation tests in Jinzhai DNs of China.

42 ENGINEERING↗

Temperature-dependent diffuse reflectance measurements of ceramic powders in the near- and mid-infrared spectra

Radiative properties are critical to quantify radiative energy fluxes between surfaces and in participating media. However, there is limited experimental data on temperature-dependent radiative properties of materials. Herein, this work focuses on experimentally measuring temperature-dependent diffuse reflectance in the near- and mid-infrared spectra (1–20 μm) for ceramic particles with applications as heat-transfer and thermal-storage media in concentrated solar power (CSP) plants. Specifically, a commercially available sintered bauxite proppant, ACCUCAST ID80, and its primary chemical constituents—alumina (Al 2 O 3 ) and silica (SiO 2 )—are measured in powder form using a Fourier transform infrared spectrometer (FTIR) coupled with a specialized diffuse reflectance accessory and a heated stage. Room-temperature diffuse reflectance measurements show increased absorption in tests with greater mass fractions of the ceramic samples. There is a strong correlation in the measured reflectance spectra of ACCUCAST with alumina and silica in the spectral range 2000–500 cm –1 (5–20 μm). Whereas, for shorter wavelengths (< 5 μm), the absorptance for ACCUCAST is greater than the absorptance for alumina and silica, indicating contributions from other chemical species present in the composite material. For the first time, temperature-dependent diffuse reflectance measurements are reported for ACCUCAST up to 1000 °C. These results are compared against those of alumina and silica through the calculation of a thermal emittance. All three materials exhibit a calculated emittance of ~0.9 at room temperature. However, this value decreases to ~0.6 for ACCUCAST and drops to less than 0.4 for alumina and silica at 1000 °C. Thermal cycling in air at 1000 °C resulted in a visible color change from dark grey to light orange for ACCUCAST and a subsequent larger increase in reflectance for wavelengths less than 5 μm as compared to ACCUCAST thermally cycled at 1000 °C in vacuum. Alumina and silica spectra proved to be largely unaffected by thermal cycling under atmospheric conditions. Overall, this study establishes a powerful technique for the characterization of radiative properties of particulate materials as a function of temperature and presents a detailed case study of ACCUCAST, a candidate for next-generation particle-based CSP.

14 SOLAR ENERGY↗

Spatiotemporally resolved measurements of electric field around a piezoelectric transformer using electric-field induced second harmonic (E-FISH) generation

When a piezoelectric transformer (PT) is actuated at its second harmonic frequency by a low input voltage, the generated electric field at the distal end can be sufficient to breakdown the surrounding gas, making them attractive power sources for non-equilibrium plasma generation. Understanding the potential and electric fields produced in the surrounding medium by the PT is important for effectively designing and using PT plasma devices. In this work, the spatiotemporally resolved characteristics of the electric field generated by a PT operating in open air have been investigated using the femtosecond electric field-induced second harmonic generation (E-FISH) method. Here, electric field components were determined by simultaneously conducting E-FISH measurements with the incident laser polarized in two orthogonal directions relative to the PT crystal. Results of this work demonstrate the spatial distribution of electric field around the PT’s output distal end and how it evolves as a function of time. Notably, the strongest electric field appears on the face of the PT’s distal surface, near the top and bottom edges and decreases by approximately 70% over 3 mm. The time delay between the PT’s input voltage and measured electric field indicates that there is an about 0.45 phase difference between the PT’s input voltage and output signal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tailoring MoS 2 for Small-Molecule Electroreduction: The Role of Metal Doping and Heterostructures

The electrification of chemical transformations central to sustainable fuel production and waste valorization, such as overall water splitting (OWS), hydrogen evolution reaction (HER), and electrochemical reduction of CO 2 (CO 2 R), presents a powerful opportunity to advance carbon-neutral energy technologies. Transition metal dichalcogenides (TMDs), particularly MoS 2 , have emerged as promising electrocatalyst candidates, owing to their abundance, tunable active sites, and defect-rich structures. This review highlights recent progress in leveraging metal doping and heterostructure engineering of MoS 2 to enhance the electrocatalytic activity and selectivity. By compiling insights from experimental studies and density functional theory (DFT) predictions, we examine how defect creation, electronic structure modification, and interface design contribute to improved charge transport and catalytic efficiency. Particular emphasis is placed on rational design principles, synthetic strategies, and operando characterization methods that provide a pathway to understanding and optimizing MoS 2 -based materials. We also discuss the challenges of stability, mechanistic ambiguity, and scaling while outlining opportunities to bridge theory and experiment. Collectively, this review underscores how defect and heterostructure engineering of MoS 2 can accelerate the development of efficient, sustainable electrocatalysts for both fuel generation and waste-to-value generation.

CO2 reduction↗

Cryogenic and Temperature-Dependent Photoelectron Spectroscopy of Metal Complexes

Negative ion photoelectron spectroscopy (NIPES) coupled with electrospray ionization (ESI) has been proved to be a powerful gas-phase spectroscopic tool for characterizing electronic structures and chemical bonding of a variety of cluster anions and corresponding neutral radicals involved in the condensed phase reactions and transformations. Since the acquisition of cryogenic and temperature-controlling capabilities, broader range of research scope has been covered. This review summarizes our recent investigations on metal complexes employing cryogenic ESI-NIPES that provide us essential information towards understanding complicated condensed phase reactions including hydrocarbon activations and electron transfer reactions, and afford us spectroscopic probe of highly reactive transient species and intimate redox pairs. Special attention has been drawn to connect gas phase photodetachment processes with solution phase redox reactions. Photodetachment of transition metal-EDTA complexes has been systematically investigated to model the sequential oxidation reactions of these species in solutions. The obtained gas phase electron affinity (EA) is compared with the solution redox potential (E1/2) and the metal ionization potential (IP) for several series of homologous metal complexes to emphasize their intrinsic correlations with deviations being largely modulated by different degrees of ligand participations.

Yuan, Qinqin↗

Sensing Service Transformer Secondary Currents using Planar Magnetic Pick-up Coils

The rapid deployment of distributed energy resources (DERs) is creating stresses on utility assets in the distribution networks. The service transformer, which is the most commonly used utility asset is often not monitored, since the cost of available sensing solutions is as high as the transformer itself. This paper presents a method to use an array of printed circuit board coils to intelligently monitor North American pole top service transformers. The approach, uses a novel, self-calibrating algorithm to infer the fixed geometry of the installation, by recording data over an extended period of time. The proposed method can enable rapid installation of a non-intrusive sensor that can be used to monitor loading levels of the distribution transformer. Furthermore, these sensors can help in planning, prognostics and advanced situational awareness for utilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Industry 4.0 and Intelligent Manufacturing Processes: A Review of Modern Sensing Technologies

Digital Manufacturing technologies have quickly become ubiquitous in the manufacturing industry. The transformation commonly referred to as the fourth industrial revolution, or Industry 4.0, has ushered in a wide range of communication technologies, connection mechanisms, and data analysis capabilities. These technologies provide powerful tools to create a more lean, profitable, and data-driven manufacturing processes. In this paper, we review modern communication technologies and connection architectures for Digital Manufacturing and Industry 4.0 applications. An introduction to Cyber-Physical Systems and a review of digital manufacturing trends is followed by an overview of data acquisition methods for manufacturing processes. Numerous communication protocols are presented and discussed for connecting disparate machines and processes. Flexible data architectures are discussed and examples of machine monitoring implementations are provided. Finally, select implementations of these communication protocols and architectures are surveyed with recommendations for future architecture implementations.

42 ENGINEERING↗

Few-cycle self-compression of GW mid-IR pulses in an anti-resonant fiber in ambient air

We report self-compression of mid-IR optical pulses to the few-cycle regime in an anti-resonant hollow core fiber filled with ambient air. Transform-limited 120-fs duration input optical pulses with 160 μJ energy are compressed to 29.8 fs (< 3 cycles) with a compression efficiency of 75%, resulting in 2.6 GW peak power few-cycle pulses. In addition, we show that nonlinear compression is maintained when the fiber is coiled, allowing for a compact setup. Lastly, we elucidate the dynamics involved in this self-compression setup via numerical simulations and identify the critical role played by Raman shifting in molecular gases and ionization limitations.

Hettel, Will [University of Colorado & NIST, Bould↗

Predictive Data Analytics Framework Using Advanced Test Reactor Acoustic Data

Although a nuclear reactor is a hostile environment for sensing and electrical communications, the reactor core is amenable to acoustic communication. An acoustic measurement infrastructure (AMI) has been installed at the Advanced Test Reactor (ATR) nozzle trench area to record acoustic signals that has the ability to capture different operating regime of the reactor. This AMI includes ATR in-pile structural components, coolant, acoustic receivers, primary coolant pumps (PCP) as signal sources, a data acquisition system, and signal-processing algorithms, enabling real-time. This report will discusses development of recursive Fast Fourier Transform approach to process in real-time acoustic signals, application of short time Fast Fourier Transform to the ATR brush data to understand the vibration level and to develop spectrograms for different primary coolant pump combinations. The combination of primary coolant pumps for normal and power axial locator mechanism of ATR are different and generates different signatures. These acoustic signatures were used to develop machine learning approaches to automatically classify different operating regimes. This lay the foundation for predictive analytic framework that can be leverage by ATR to optimize their operation and maintenance. The path forward involves continued engagement with ATR and expanded implementation of AMI and predictive framework at ATR and other facilities within INL and at other experimental reactors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solar Canopy Expansion Project (Final Technical Report)

This project is a parking-lot canopy solar photovoltaic system, consisting of four canopy structures and 1,080 470-watt (W) modules. The nameplate rating of the project is 507.6 kilowatts direct current (kWDC) at Standard Test Condition (STC), and 448 kilowatts alternating current (kWAC). It is interconnected to the existing Tribe-owned medium-voltage micro-grid generation system via a step-up transformer and short medium-voltage line. This project offsets energy usage from more expensive existing sources, specifically the Tribe-owned gas-fired engine generators providing the primary power source for existing Tribal facilities and the electric utility, which provides an alternate source. The solar photovoltaic system is a renewable source, which has the benefit of reducing reliance on fossil-fuel burning sources. By reducing demand on existing Tribe-owned conventional generators, the project has avoided the need to add more conventional generation and has prolonged the lifespan of existing gas-fired engine generators. The project reduced energy costs and reliance on fossil-fuel burning power sources, increasing Tribe-owned generating sources and self-reliance, and prolonging the lifespan of existing generators. A side benefit to the project is the production of dozens of covered parking spaces in the existing parking lot.

14 SOLAR ENERGY↗

Distribution Grid Impact Study in Highland Park, Michigan: Understanding Rooftop Solar, Behind-the-Meter Energy Storage, Electric Vehicle Charging, and Building Electrification [Slides]

Through the Communities LEAP (Local Energy Action Program) Pilot, the National Renewable Energy Laboratory (NREL) engaged the Highland Park Stakeholder Coalition to scope four technical assistance work areas to address their energy needs and goals. This slide deck addresses the highlighted tasks under work area "B" related to policy analysis, due diligence, and case studies for removing barriers and providing best practices for local clean energy development. Highland Park community members face frequent, long-duration power interruptions due largely to the aging distribution system serving the area and the legacy design standards used in its construction. While degrading physical infrastructure such as poles, crossarms, and transformers can result in this substandard reliability, another notable characteristic of this legacy system is the lower, 4.8 kV, voltage class. This is a legacy construction standard which many utilities, DTE included, are phasing out in favor of higher, 15 or 25 kV, voltage classes instead. The existing 4.8 kV distribution system serving Highland Park may limit significant adoptions of clean-energy technologies like high percentages of building electrification or electric vehicle adoption. The following analysis seeks to quantify these limitations under a variety of clean-energy technology adoption scenarios. It compares the overall system risks of the present system to those of a hypothetical, upgraded 13.2 kV system, using NREL-developed risk metrics and offers upgrade cost considerations. The legacy 4.8 kV voltage class serving Highland park is not, as we have modeled it, a major limitation to the widespread adoption of cost-optimal rooftop solar and/or behind-the-meter energy storage. Within our modeling framework, these technologies namely impact secondary, low-voltage assets, which may be remedied without the need for a system-wide upgrade to a 13.2 kV voltage class. Our model of the current 4.8kV system indicates it is not capable of supporting community-wide electrification efforts. Widespread building electrification, and the resulting large increase in wintertime load, dramatically increases the prevalence of voltage violations and thermal overloading on the current 4.8 kV distribution system. These impacts illustrate the need for system-wide upgrades to a 13.2 kV voltage class to accommodate these technologies. Low to Moderate DER adoption does not adversely impact the grid but does improve undervoltage and asset overloading issues. However, these benefits are insufficient to defer grid upgrades. Higher DER penetration is shown to increase overvoltage and asset overloading in future electrification scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Quasar Shedding Its Dust Cocoon at Redshift 2

We present the first near-IR spectroscopy and joint analyses of multiwavelength observations for SDSS J082747.14+425241.1, a dust-reddened, weak broad emission-line quasar (WLQ) undergoing a remarkable broad-absorption line (BAL) transformation. The systemic redshift is more precisely measured to be z = 2.070 ± 0.001 using Hβ compared to z = 2.040 ± 0.003 using Mg ιι from the literature, signifying an extreme Mg ιι blueshift of 2140 ± 530 km s –1 relative to Hβ. Using the Hβ-based single-epoch scaling relation with a systematic uncertainty of 0.3 dex, its black hole (BH) mass and Eddington ratio are estimated to be M BH ~ 6.1 × 10 8 M ⊙ and λ Edd ~ 0.71, indicative of being in a rapidly accreting phase. Our investigations confirm the WLQ nature and the LoBAL → HiBAL transformation, along with a factor of 2 increase in the Mg ιι+Fe ιι emission strength and a decrease of 0.1 in E(B – V) over two decades. The kinetic power of this LoBAL wind at R ~ 15 pc from its BH is estimated to be ~43% of the Eddington luminosity, sufficient for quasar feedback upon its host galaxy albeit with an order-of-magnitude uncertainty. This quasar provides a clear example of the long-sought scenario where LoBAL quasars are surrounded by dust cocoons, and wide-angle nuclear winds play a key role in the transition of red quasars evolving into the commonly seen blue quasars.

79 ASTRONOMY AND ASTROPHYSICS↗

Data Security Defense: Modeling and Detection of Synchrophasor Data Spoofing Attack for Grid Edge

Data security and cyberattack have become critical issues in the distributed power system where adversaries can swap the source information of sensors or even spoof and alter measurements. However, the cyber security of the power system is challenged by the unpredictability and stealth of the spoofing attacks. Here, to protect the data security at the grid edge, this paper developed a synchrophasor data spoofing attack detection framework based on the time-frequency feature extraction techniques including the short-time Fourier transform (STFT) and object detection network for real-time synchrophasor data categorization and spoofing attack localization. The proposed approach outperforms earlier work in terms of spoofing attack detection and offers a vital localization function employing distributed synchrophasor sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Optimization Competition on Synthetic and Industrial Power Systems

This paper summarizes a grid optimization (GO) competition effort in the United States to find the best solution strategies for up to interconnect-scale power system networks with around 32,000 buses. The optimization problem is a mixedinteger, non-convex non-linear problem, (MINLP) and includes discrete variables such as unit commitment and line switching, control settings (transformer taps and phase shifters with impedance correction tables), and bus shunts. The case study includes six actual industry grids as well as 16 realistic synthetic grids created by three different dataset teams. The winners are selected and ranked based on scoring criteria, which consider the solution quality (such as objective functions) within time limits. Nine winner teams are selected from 26 competitor teams. The results achieved by different teams are described and the performance of different algorithms on synthetic grids and actual industry grids are compared and analyzed.

mixed-integer non-linear programming↗

High-Efficiency, Medium-Voltage-Input, Solid-State-Transformer-Based 400-kW/1000V/400A Extreme Fast Charger for Electric Vehicles

Range anxiety and long battery charging time continue to be critical challenges to mass adaptation of EVs. A major identified gap to wider adoption of BEVs is the ability and availability to refuel quickly or to fast charge. Studies have shown that in areas where drivers have access to 50-kW or 120-kW fast charge stations, annual electric vehicle (EV) miles traveled (i.e., eVMT) increased by over 25%, even in cases where fast charging was used for 1% to 5% of total charging events. Charge stations of higher power not only alleviate the “range anxiety” and reduce the driver’s waiting time, but also requires less investment. Michigan Energy Office completed a study in early 2019 titled “Electric Vehicle Charger Placement Optimization in Michigan: Phase I – Highways”. This study finds a system with 150kW chargers, though more expensive individually, actually has lower total system cost when compared to a 50kW charging system when serving the same battery size EV. To be truly competitive to the ICEV refueling experience, even higher power stations are necessary. However, high power charge stations would create large power draws from the grid. If this occurs during peak demand periods, grid capacity could be overloaded. This problem needs to be addressed to reduce the impact on the electric utility infrastructure. The main goal of this project is to develop a 400-kW/400-A XFC system targeting total efficiency of 96.5 percent from the MVAC grid to a vehicle. The novel SST power cell topology, combined with a new silicon carbide (SiC) MOSFET device, enables a 3.5 percent improvement in system efficiency, a 50-percent smaller equipment footprint, and four times less weight than today’s DCFC systems. The SST technology would directly utilize MVAC at 4.8-kV or 13.2-kV. This would eliminate the line frequency transformer (LFT), which steps down medium-voltage AC to 3-Phase 480-V line-to-line voltage in current DCFC systems.

42 ENGINEERING↗