Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

A polarimetry-based field-deployable non-interruptive mirror soiling detection method

The soiling level of heliostat mirrors in Concentrated Solar Power (CSP) fields is one of the key factors that significantly influences optical efficiency. State-of-the-art methods of monitoring heliostats soiling levels still face various challenges, including slow speed, labor-intensive operations, resolution and accuracy constraints or interruptions to solar field operations. Here, we present a rapid, cost-effective, and non-intrusive method for mirror soiling detection based on polarimetric imaging, referred to as Polarimetric Imaging-based Mirror Soiling (PIMS). The compact PIMS device is designed for integration with unmanned aerial vehicles (UAVs), enabling rapid, large-area assessments of heliostat mirrors for efficient soiling detection. Our method utilizes the correlation between the Degree of Linear Polarization (DoLP) and surface soiling level based on Mie scattering theory and Monte Carlo simulations. Field deployment of the PIMS method requires minimal device installation, and its UAV-based operation allows for soiling detection without interrupting plant activities. The PIMS method holds the potential for mirror soiling detection across various concentrated solar power (CSP) plants and can be further adapted for other types of solar fields, such as parabolic trough systems.

CSP Field↗

Identifying Periodic Variable Stars and Eclipsing Binary Systems with Long-term Las Cumbres Observatory Photometric Monitoring of ZTF J0139+5245

We present the results of our search for variable stars using the long-term Las Cumbres Observatory (LCO) monitoring of white dwarf ZTF J0139+5245 with the two 1.0 m telescope nodes located at McDonald Observatory using the Sinistro imaging instrument. In this search, we find 38 variable sources, of which 27 are newly discovered or newly classified (71%) based on comparisons with previously published catalogs, thereby increasing the number of detections in the field of view under consideration by a factor of ≈2.5. We find that the improved photometric precision per exposure due to longer exposure time for LCO images combined with the greater time sampling of LCO photometry enables us to increase the total number of detections in this field of view. Each LCO image covers a field of view of 26' × 26' and observes a region close to the Galactic plane (b = -9.°4) abundant in stars with an average stellar density of ≈8 arcmin{sup -2}. We perform aperture photometry and Fourier analysis on over 2000 stars across 1560 LCO images spanning 537 days to find 28 candidate BY Draconis variables, three candidate eclipsing binaries of type EA, and seven candidate eclipsing binaries of type EW. In assigning preliminary classifications to our detections, we demonstrate the applicability of the Gaia color–magnitude diagram as a powerful classification tool for variable-star studies.

47 OTHER INSTRUMENTATION↗

U.S. Domestic Small Modular Reactor Security by Design

U.S. nuclear power facilities face increasing challenges in meeting evolving security requirements caused by evolving and expanding threats while keeping cost reasonable to make nuclear energy competitive. The addition of security features after a facility has been designed and without attention to optimization (the past approach) can lead to cost overruns. Incorporating security in the design process can provide robust, cost effective, and sufficient physical protection systems. The purpose of this work is to develop a framework for the integration of security into the design phase of Small Modular Reactors (SMRs) and the use of modeling and simulation tools to optimize the design of physical protection systems. This effort will intend to integrate security into the design phase of a model SMR that meets current NRC physical protection requirements and provide advanced solutions to improve physical protection and decrease costs. A suite of tools, including SCRIBE3D, PATHTRACE and Blender were used to model a hypothetical generic domestic SMR facility. Physical protection elements such as sensors, cameras, portal monitors, barriers, and guard forces were added to the model based on best practices for physical protection systems. One outsider sabotage scenario was examined with 4-8 adversaries to determine security metrics. This work will influence physical protection system designs and facility designs for U.S. domestic SMRs. The purpose of this project is to demonstrate how a series of experimental and modeling capabilities across the Department of Energy Complex can impact the design of U.S. domestic SMRs and the complete Safeguards and Security by Design (SSBD) for SMRs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Study on Application of Distributed Network of Sensors with List Mode for NMAC Literature Review

Nuclear material accounting and control (NMAC) for nuclear security detects, deters, and resolves questions related to unauthorized removal (i.e. theft) or misuse of nuclear material. NMAC also serves as a key insider threat mitigation measure and aids in recovery of nuclear material that is missing. Effective nuclear security depends on NMAC for timely and accurate information about nuclear material types, quantities, and locations. Bulk nuclear material processing facilities, however, present unique challenges for effective NMAC due to the presence of large quantities of material in-process and the accumulation of residual material holdup within process equipment. These holdup accumulations can obscure accurate physical inventory taking and complicate efforts to resolve NMAC irregularities at the facility level. Bulk material monitoring systems often rely on material balance calculations and indirect measurement techniques, which may mask protracted theft of smaller amounts of nuclear material. These monitoring limitations have generated increased interest in continuous monitoring technologies, including distributed non-destructive assay (NDA) sensor networks capable of providing real-time or near-real-time measurement of material movement and accumulation within bulk processing environments. Recent advancements in distributed networks of NDA radiation detectors and sensing technologies provide an opportunity to address these limitations. Although such distributed sensor networks have been implemented in select facilities for IAEA Safeguards applications, their potential for supporting NMAC functions specifically tailored to nuclear security objectives remains largely unexplored. Furthermore, emerging list-mode data acquisition technologies have reached high technology readiness levels, enabling time-correlated detection of nuclear events across multiple temporal scales. These capabilities provide enhanced opportunities for accurate holdup measurement, continuous process monitoring, and improved detection of material theft or misuse over time. The increasing global expansion of civil nuclear power and development of related bulk material processing facilities, including those supporting high-assay low-enriched uranium (HALEU) and other advanced reactor fuel fabrication, further increases the need for advanced measurement and monitoring strategies for NMAC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Vegetation Warming Experiment: Landscape-scale digital camera imagery for vegetation phenology, Utqiagvik (Barrow), Alaska, 2018

Images captured using a StarDot NetCam SC phenocamera looking east from the top of the Barrow Environmental Observatory (BEO) Sled Shed, Utqiagvik, Alaska. The camera was installed to remotely monitor plant phenology and operation of the BNL TEST group's ZPW (Zero Power Warming) chambers during the growing season of 2018. Images were captured from early spring (13 April) through to mid fall (18 October). Snowmelt, vegetation growth and senescence, and snow accumulation were captured. Images were uploaded to the BNL FTP server every hour until 16 June, and then every 10 minutes. Files were renamed with the date and time of the image. jpg images have been compressed in *.tar.gz format (7.9 GB). Different fields of view (northeasterly) were also captured using 3 Wingscapes TimelapseCam cameras mounted on a mast on the sled shed. Images were recorded from 21 June to 24 September, 2018, at 30 minute intervals, from 11:00 - 14:30, Alaska daylight time (AKDT, UTC-8). Movie files (.mp4) of each Wingscapes camera dataset. Additional metadata included in *.pdf and *.csv files. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

2020 State of the Science Report, Chapter 14: Summary and Path Forward

The 2020 State of the Science report collates and presents the current understanding of interactions between marine renewable energy (MRE) systems and the marine environment, with an emphasis on their effects on marine animals, habitats, and oceanographic systems, using publicly available information. The report places this information in context through lessons learned from research studies in the laboratory and in the field, modeling simulations, and deployments; monitoring around demonstration, pilot, and small commercial MRE projects; and identifies gaps in knowledge and makes recommendations for filling those gaps. In addition, strategies for moving toward a consistent and effective consenting or permitting (hereafter consenting) process and management of the potential effects of MRE development are highlighted. The status and recommendations from each of the priority interactions between MRE devices and the environment are summarized here, and the management strategies for facilitating development are discussed. Finally, a path forward toward commercial MRE development is explored. https://tethys.pnnl.gov/publications/state-of-the-science-2020-chapter-14-summary-path-forward

16 TIDAL AND WAVE POWER↗

From MAST-U to STEP: Power exhaust control challenges and opportunities

This work explores the challenges and opportunities for power exhaust control in STEP, informed by dedicated MAST-U experiments. The STEP system primarily relies on hydrogenic and argon gas injection into the divertors, compensating for transients originating in the plasma core. Fast transients (>10 Hz) that evolve too quickly for actuators to compensate must be absorbed passively; the enhanced transient buffering of the foreseen long-legged divertor provides a clear advantage over conventional geometries, as demonstrated in the MAST-U Super-X divertor. Experiments further indicate that STEP’s tight divertor baffling enables near-independent control of the upper and lower divertors. The most challenging transients are expected from power-sharing fluctuations, as MAST-U experiments observed extremely fast dynamics. Fluctuations from core pellet fuelling remain relatively benign due to the small pellet size according to simulations. Exhaust control in a reactor like STEP requires an integrated approach befitting its machine-critical nature. A predictive control element, integrated with core plasma control, allows pre-emptive preparation of the divertor for incoming transients. An observer-based diagnostic approach is foreseen to monitor the divertor in the challenging reactor environment, supported by an extended diagnostic set in the non-nuclear phase to validate the required dynamic models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

US Department of Energy, Office of Science High Performance Computing Facility Operational Assessment 2021: Oak Ridge Leadership Computing Facility

Oak Ridge National Laboratory’s (ORNL’s) Leadership Computing Facility (OLCF) continues to surpass its operational target goals of supporting users; delivering fast, reliable computational ecosystems; creating innovative solutions for high-performance computing (HPC) needs; contributing to the community to build the next generation HPC workforce, and managing risks, safety, and security associated with operating some of the most powerful computers in the world. The results can be seen in the cutting-edge science conducted by users and the praise from the research community. Calendar year (CY) 2021 saw continued excellence in research supported by the OLCF’s leadership-class computing resources, including Summit (the nation’s most powerful supercomputer), the global scratch file system Alpine, the Scalable Protected Infrastructure (SPI), the Exploratory Visualization Environment for Research in Science and Technology (EVEREST), and the archival mass-storage resource High-Performance Storage System (HPSS). While maintaining access and exceptional user support for Summit, the OLCF continued to make progress on the installation and deployment of Frontier, which will be the nation’s first exascale system when it comes online at the start of CY 2023. Users have already begun running and optimizing scientific codes on Crusher, the OLCF test and development system equipped with Frontier’s architecture. Throughout the year, the OLCF maintained a strong culture of operational excellence, including risk management, workplace safety, and cybersecurity. The OLCF’s rigorous risk management strategy anticipated and mitigated risks, and at this time there are no high-priority operational risks. Similarly, ORNL and the OLCF were committed to operating under the US Department of Energy’s (DOE’s) safety regulations that ensure a safe workplace. Technical staff tracked and monitored existing threats and vulnerabilities within the OLCF while continually developing tools and practices to enhance operations without increasing the facility’s risk. CY 2021 was filled with outstanding results and accomplishments, including a very high rating from users on overall satisfaction for the eighth consecutive year; a tremendous number of node hours delivered to 1,671 researchers on Summit; and the successful delivery of the allocation split of roughly 60%, 20%, and 20% of core-hours offered for the Innovative and Novel Computational Impact on Theory and Experiment (INCITE), Advanced Scientific Computing Research Leadership Computing Challenge (ALCC), and Director’s Discretionary (DD) programs, respectively (Section 2). COVID-19 research remained a focus in 2021, and the ALCC and DD programs allocated over 1 million Summit hours to the COVID-19 High Performance Computing Consortium. These accomplishments, coupled with the high utilization rates (i.e., overall and capability usage), represent the fulfillment of the promise of leadership class machines: efficient facilitation of leadership-class computational applications.

97 MATHEMATICS AND COMPUTING↗

Age-specific case data reveal varying dengue transmission intensity in US states and territories

Dengue viruses (DENV) are endemic in the US territories of Puerto Rico, American Samoa, and the US Virgin Islands, with focal outbreaks also reported in the states of Florida and Hawaii. However, little is known about the intensity of dengue virus transmission over time and how dengue viruses have shaped the level of immunity in these populations, despite the importance of understanding how and why levels of immunity against dengue may change over time. These changes need to be considered when responding to future outbreaks and enacting dengue management strategies, such as guiding vaccine deployment. We used catalytic models fitted to case surveillance data stratified by age from the ArboNET national arboviral surveillance system to reconstruct the history of recent dengue virus transmission in Puerto Rico, American Samoa, US Virgin Islands, Florida, Hawaii, and Guam. We estimated average annual transmission intensity (i.e., force of infection) of DENV between 2010 and 2019 and the level of seroprevalence by age group in each population. We compared models and found that assuming all reported cases are secondary infections generally fit the surveillance data better than assuming all cases are primary infections. Using the secondary case model, we found that force of infection was highly heterogeneous between jurisdictions and over time within jurisdictions, ranging from 0.00008 (95% CrI: 0.00002–0.0004) in Florida to 0.08 (95% CrI: 0.044–0.14) in American Samoa during the 2010–2019 period. For early 2020, we estimated that seropositivity in 10 year-olds ranged from 0.09% (0.02%–0.54%) in Florida to 56.3% (43.7%–69.3%) in American Samoa. In the absence of serological data, age-specific case notification data collected through routine surveillance combined with mathematical modeling are powerful tools to monitor arbovirus circulation, estimate the level of population immunity, and design dengue management strategies.

60 APPLIED LIFE SCIENCES↗

Autonomous Tools for Attack Surface Reduction (Final Report)

The electric power grid is a complex critical infrastructure that forms the lifeline of modern society, and its secure and reliable operation is of paramount importance to national security and economic wellbeing. However, recent findings documented in authoritative sources indicate the threat of cyber-based attacks growing in numbers and sophistication. However, securing the grid against stealthy cyberattacks is a challenging task due to legacy nature of the infrastructure coupled with dynamic nature of threat landscape and ever-growing sophistication of the adversaries. Additionally, the grid’s attack surface continues to grow with the increased dependence on digital communications and control that now extends to each consumer through smart meters and distributed energy resources. Unfortunately, this expansive surface increases the grid’s vulnerability and further exposes critical control systems in both substations and control centers. To respond to this emerging need, we had successfully assembled an interdisciplinary team with academic- industry partnership to successfully conduct research, development, evaluation, demonstration, and commercialization of attack surface reduction tools, whose goal was to significantly reduce the cyber attack surface in the North American power grid. Our proposed project was a synergistic collaborative effort leveraging the synergistic expertise of the team members across power systems, cyber security and CPS security, testbeds, field deployments and demonstration, and successful commercialization. The following are the specific tasks that have been successfully completed two phases (2016-2020). Phase I: Task 1: Developed and implemented a robust Project Management and Data Management Plan, coupled with a well thought out Risk Mitigation Plan. Task 2.1: Developed a comprehensive framework that continually assesses and autonomously reduces the attack surface for the power grid control environment spanning across substations, control center and the SCADA network to significantly reduce the risks of cyber attacks. Task 2.2: Developed attack surface analysis techniques, metrics, and tools that assess the attack surface at multiple levels including the control center, substations, and the SCADA network. Task 2.3: Developed attack surface reduction techniques and tools that dynamically reduce attack surface and hence increase attacker’s cost without interfering in the critical functions of the system. Task 2.4: Prototyped, implemented, and quantitatively evaluated/validated the techniques and tools on a realistic industrial CPS security testbed environment by leveraging the unique resources of the team. Task 3: Developed Commercialization plan to transition the developed tools into power system industry stakeholders for a broader adoption by leveraging the expertise of our industrial members. Phase II: Task 4: Successfully completed field demonstration, verification, and evaluation of the effectiveness of the attack surface analysis and reduction techniques on a realistic utility testbed environment. This also involved the development of realistic scenarios, sound metrics, data sets, evaluation criteria, and documentation. Technology integration & Field demonstration: The project had significantly advanced the state-of-the-art research and practice in improving the cybersecurity of our nation’s power grid infrastructure against cyber threats. In particular, the proposed, designed, and deployed attack surface analysis and reduction algorithms and tools have contributed to significantly reducing the exposure and risk of the devices, substations, and the integrated SCADA/EMS/ DMS grid environment to cyber threat. Strong demonstration and evaluation techniques have verified the feasibility of the developed techniques on realistic cyber-physical testbeds and utility partner's real grid environment, and collaborative research and evaluation of attack surface reduction techniques (for wide-are monitoring and control) within a vendor (GE) EMS platform. The Attack Host Analyzer (AHA) tool that was developed through this project was made available through GitHub.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deep compressed seismic learning for fast location and moment tensor inferences with natural and induced seismicity

Fast detection and characterization of seismic sources is crucial for decision-making and warning systems that monitor natural and induced seismicity. However, besides the laying out of ever denser monitoring networks of seismic instruments, the incorporation of new sensor technologies such as Distributed Acoustic Sensing (DAS) further challenges our processing capabilities to deliver short turnaround answers from seismic monitoring. In response, this work describes a methodology for the learning of the seismological parameters: location and moment tensor from compressed seismic records. In this method, data dimensionality is reduced by applying a general encoding protocol derived from the principles of compressive sensing. The data in compressed form is then fed directly to a convolutional neural network that outputs fast predictions of the seismic source parameters. Thus, the proposed methodology can not only expedite data transmission from the field to the processing center, but also remove the decompression overhead that would be required for the application of traditional processing methods. An autoencoder is also explored as an equivalent alternative to perform the same job. We observe that the CS-based compression requires only a fraction of the computing power, time, data and expertise required to design and train an autoencoder to perform the same task. Implementation of the CS-method with a continuous flow of data together with generalization of the principles to other applications such as classification are also discussed.

54 ENVIRONMENTAL SCIENCES↗

Artificial Intelligence for Digital Security and Protections

Proper functioning of nuclear power plants relies on a mix of well-regulated human and machine-driven workflows. This regulation supports nuclear safety through a series of processes and many of the tasks that support these processes have a repetitive nature that make artificial intelligence (AI) informed by machine learning (ML) a potential aid in a variety of tasks. AI is being evaluated for activities that include inspections, fuel processing, monitoring, and other activities. The introduction of any new technology presents a potential new attack vector. In the case of AI/ML, there are many attacks that have already been discovered and over time the attacks can be expected to follow the growth pattern observed in cyber security. While future planning is necessary, current efforts need to be established now to predict the threat emergence over the next year 10 years and mitigate potential threats. Based on these observations, AI/ML will need to become trustworthy, which corresponds to techniques and procedures that emphasize AI explainability along with resilience techniques to data, algorithms, models, and systems. This kind of system robustness is the foundation for defenses against AI/ML-specific attacks. Attempting to look forward and take a broad view of capabilities provides input to research roadmaps and the ability to distill vulnerabilities into specific use cases may provide greater assistance in understanding the technology benefits while introducing new risks. The impact of current and future AI in three areas—capabilities, challenges, and recovery strategies—represents an initial attempt at balancing both.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Heat Generation Concerns Associated with Extreme Fast Charging

Present-day thermal management systems for battery electric vehicles are inadequate in limiting the maximum temperature rise of the battery during extreme fast charging. Incorrect thermal management designs for extreme fast charging conditions could result in cells reaching abuse temperatures and potentially sending the cells into thermal runaway. Furthermore, the cell and module design needs to be improved to meet the lifetime expectations of the consumer. Each of these aspects is explored and addressed as well as outlining where the heat is generated in a cell, the efficiencies of power and energy cells, and how to potentially measure the internal temperatures of a battery. Thermal management is not a limiting condition with regards to extreme fast charging, but many factors need to be addressed especially for future high specific energy density cells to meet U.S. Department of Energy cost and volume goals.

ADVANCED PROPULSION SYSTEMS↗

RL-HEMS: Reinforcement Learning Based Home Energy Management System for HVAC Energy Optimization

Heating, ventilation, and air conditioning (HVAC) is one of the major energy consumers in the residential sector. It is important to be able to monitor and control the energy consumed to provide utility services such as load shaping while satisfying the comfort and economic constraints of the homeowner. The objective of this work is to create the optimal schedule for HVAC operation to reduce the cost while satisfying the home-owner and equipment’s constraints using a model-free Reinforcement Learning (RL)-based optimization. The specific goal is to find the right balance between reducing energy cost, consumption, and customer comfort level. Our research effort addresses this optimization problem using multiple components: the development of initial learning test-bed and implementation of RL techniques on a real home. This will enable the rapid evaluation of the RL techniques and provide an early baseline to train before implementation on site. The RL algorithm is designed to learn the energy use patterns and generate the optimized schedule for HVAC within an acceptable time-interval to satisfy the homeowner’s comfort and minimize the energy usage. Our preliminary results are promising and we have observed a 17% reduction in the total cost and a 15% reduction in the power utilization using our RL-based HVAC model—RL-HEMS.

Kotevska, Olivera↗

Remote monitoring system

A remote monitoring system for monitoring parameters of an underground asset, such as an electric cable system, a pipeline serving as a conduit for water, gas, oil, sewage, or the like. Parameter detectors, such as sensors that measure temperature, voltage, current, moisture, etc., are distributed along the asset to provide electrical signals that represent respective monitored parameters of the asset. An underground hub disposed in an underground vault, or manhole, through which the asset passes is coupled to the parameter detectors to acquire the signals provided by the parameter detectors. The hub includes a controller to provide data derived from the acquired signals, the data being transmitted to a remote central location by a transceiver, or modem, via LP-WAN communication. Signals from the transceiver are transmitted directly from underground.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extraction of Vibration Data with Imaging

To date, the primary sensing technology used to measure the vibration response has been accelerometers and strain gages mounted directly to the structure and using either wired or, more recently, wireless telemetry. Cost issues with these sensors and the associated data acquisition systems typically limit the numbers that are deployed on in situ structures. Although there are a few structures with larger sensing counts that in some cases exceed over 1000 sensors, more typical numbers range from ten to one hundred sensors resulting in low spatial resolution when they are applied to physically large systems. When one considers that nuclear power plant structures usually have complex geometries, material properties, connectivity and boundary conditions, it is clear these current approaches to vibration measurements can only provide limited information about a system’s dynamics response characteristics. As an alternative, many non-contact measurement technologies have emerged, including point wise measurement methods such as Global Positioning System (GPS), microwave interferometry, and laser Doppler vibrometry (LDV), as well as simultaneous full-field measurement methods such as electronic speckle pattern interferometry, holography interferometry, and muon tomography, some of which can provide high spatial resolution measurements. Among these methods, digital video imaging techniques have emerged as a feasible solution for full-field vibration measurements that provide significantly more detailed dynamic response information because every pixel becomes a measurement point. Furthermore, recent advances in image processing and computer vision algorithms have been successfully used to process video data for experimental and operational modal analysis. Such full-field measurements have the potential to significantly improve many current structural assessment procedures including system identification (modal parameter estimation), structural health monitoring, load reconstruction, model validation, and model updating. Furthermore, more recent full-field imaging techniques can be accomplished with relatively low-cost, commercially-available off-the-shelf cameras. However, these measurement procedures have other limitations that must be considered such as the ability to only measure visibly accessible points on a structure and a more limited dynamic range and bandwidth than can be achieved with accelerometers or strain gages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Multi-Analysis Approach for Estimating Regional Health Impacts from the 2017 Northern California Wildfires

In the evening of October 8 and early hours of October 9, 2017, high winds in Northern California downed trees and power lines, igniting some of the most devastating wildfires the state had seen, and within hours unhealthy air quality impacted millions of people. We simulated these air quality conditions using fire detection information from the MODIS, VIIRS, and GOES-16 ABI satellite instruments, and applying a set of three WRF–CMAQ simulations, one data fusion, and three machine learning methods. We investigated using the 5-min available GOES-16 fire detection data to simulate timing of fire activity to allocate emissions hourly for the WRF-CMAQ air quality modeling system. Interestingly, this approach did not necessarily improve results compared to the baseline case, which used a default time profile. However, this approach was key to simulating the initial 12-hr explosive fire activity and smoke impacts. The WRF-CMAQ simulations compared well with observational data for the October 8-15 time period and tended to overestimate concentrations October 16-20. To improve these results, we applied three machine learning algorithms. We also had a unique opportunity to evaluate results with temporary monitors deployed specifically for wildfires, and performance was markedly different. For example, at the permanent monitoring locations, the WRF-CMAQ simulations had a Pearson correlation of 0.65, and the data fusion approach improved this (Pearson correlation = 0.95), while at the temporary monitor locations across the WRF-CMAQ, data fusion, and machine learning datasets, the best Pearson correlation was 0.5. The data fusion and machine learning results were biased low and WRF-CMAQ results were biased high. Finally, we applied the optimized PM2.5 exposure estimate in a short-term exposure-response function. Total estimated mortality attributable to PM2.5 exposure during the smoke episode was 83 (95% confidence interval: 0, 196) with 47% of these deaths attributable to wildland fire smoke.

O'Neill, Susan↗

Application of Site Controllers for Electrification of Commercial Fleet Vehicles

Electrification of transportation fleets presents a significant challenge for commercial customers. These challenges can be specific to region, weather, operating schedule, charging infrastructure, and other factors. This paper presents the value of integrating a site controller to monitor the health of assets and co-optimize the operation of commercial sites with multiple distributed energy resource technologies and electric vehicle fleets. The tests demonstrate smart-charging and vehicle-to-building uses compared to business-as-usual cases. The secondary objectives of power management for the customer vehicle are optimized by a planning tool (REopt) and integrated using the site controller. Any deviations from the planned dispatch are addressed by the real-time controllers offering tertiary controls, such as energy management, and limiting the reverse power flow (back into the grid). The results indicate that site controllers offer an efficient solution to manage the health of the connected assets and a scalable means to optimize the operations of a commercial customer with electrified transportation fleets.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗