Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system managements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Bidding Curve Design for Hybrid Power Plants with Uncertain Solar Forecast: Preprint

This paper presents a novel bidding curve design algorithm tailored for hybrid power plants (HPPs) to participate in the wholesale electricity market. Utilizing forecasts for photovoltaic (PV) generation and available battery power, our algorithm strategically computes the bidding curve to maximize HPP profit while adeptly managing the inherent uncertainty associated with PV power generation. In addition, the introduction of the penalty cost in HPP bidding curves provides the system operator a tool to effectively manage the system-level uncertainty that caused by HPPs. Numerical analysis through Monte Carlo simulations confirms that our bidding curve methodology outperforms the benchmark across various scenarios.

bidding curve↗

Preparing Distribution Utilities for the Future - Unlocking Demand-Side Management Potential: A Novel Analytical Framework

The balance of supply and demand in the power systems has traditionally been served solely through generation and network capacity planning and operations. However, with increased requirements for flexibility due to the uptake in variable renewable generation sources such as wind and solar there is a need to increased demand-side flexibility. In addition, there are increased communications and flexibility capabilities emerging on the demand-side from the adoption of advanced metering infrastructures and smart meter deployment and intelligent loads such as smart thermostats and schedulable white goods (e.g. dishwashers and washing machines). Unlocking demand-side flexibility can bring system benefits from peak load reduction bringing about generation capacity and network upgrade deferral, to reducing demand and more efficient utilization of generation and network capacity. Unlocking demand-side flexibility is an evolving process for utilities and solutions must be tailored to each specific customer group. Demand-side management (DSM) is a broad set of tools that can include demand response (both dispatchable and non-dispatchable), energy efficiency and distributed energy resources and demand-side technologies. The National Renewable Energy Laboratory (NREL), in collaboration with BSES Rajdhani Power Ltd. (BRPL) and Deloitte, examined the potential of DSM in BRPL’s service territory, developing detailed information on customer classes and willingness to participate in DSM. The study developed modeling frameworks for load analysis and the analysis tools to assess the potential of time-of-use tariffs in motivating customers to reduce their peak period energy consumption. The study shows that BRPL customers, specifically their domestic customers, are willing to participate in DSM programs and that time-of-use pricing can help BRPL reduce their peak demand and help unlock demand-side flexibility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilience in Infrastructure Systems [Slides]

Threats and Resilience of the US Energy Infrastructure are described, including a summary of the CleanStart Distributed Energy Resource Management System (DERMS) project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Secure Communications Concept and API Concept for Integrating XENDEE Positronix with TESLA PowerPack System at Site 300 (Final Deliverable)

The CleanStart DERMS project focuses on the management of Distributed Energy Resources (DER) for enhanced distribution grid resilience. The demonstration site has changed from Riverside Public Utility to the LLNS Site 300 DERS demonstration site. This project has so far focused only on device level controllers and local area controllers. These controllers potentially lack the ability to perform supervisory control and grid interactive control functions, essential for grid-level optimal DER management. This project seeks to close that gap in development of secure communication concept and appropriate Application Programming Interfaces (API) to enable integration with DERs, device level and local area controllers, such as Distributed Energy Resources Management System (DERMS).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integration of Microgrids, DER Aggregators, and DERMS with ADMS

Distributed energy resource (DER) management and control is disjointed, siloed, and at times conflicting. Behind-the-meter (BTM) assets can provide significant flexibility but are poorly integrated with the grid. Centralized control methods alone are not scalable. The objective is to develop and demonstrate an architecture that: provides reliable, resilient, and secure grid services; enables scalable, near-real-time management of utility- and small-scale DERs; supports transactive control, aggregation, and direct control of DERs; and incorporates existing utility management systems.

ADMS↗

Utilization of available skills and materials in fire prevention

Procedures for installing fire protection systems in large buildings are discussed. Factors considered in the safety management are: (1) distribution of water supply, (2) design and location of exits, (3) emergency power system, and (4) maintenance procedures.

Martin, H. W.↗

Recent Development of Frequency Estimation Methods for Future Smart Grid

The frequency estimated by the Phasor Measurement Unit (PMU) is a critical index of power system status and supports many smart grid applications. The future smart grid features high penetration of renewables and more fast-moving power electronics inverters but raises challenges to the reliable frequency estimation. This article presents three methods to address these challenges. First, an enhanced zero-crossing algorithm was developed to track the fast-changing frequency in system dynamics. Second, we propose a technology that can tolerate the system transient and suppress the outliers. Third, an algorithm was developed to export high time-resolution frequency estimations with minimum computational effort. All of the proposed methods are realized in hardware and compared with classical frequency estimation methods. The testing results indicate that the proposed methods have excellent performance. They can be used in future PMUs and provide reliable and high time resolution data for smart grid applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bidding Curve Design for Hybrid Power Plants with Uncertain Solar Forecast

This paper presents a novel bidding curve design algorithm tailored for hybrid power plants (HPPs) to participate in the wholesale electricity market. Utilizing forecasts for photovoltaic (PV) generation and available battery power, our algorithm strategically computes the bidding curve to maximize HPP profit while adeptly managing the inherent uncertainty associated with PV power generation. In addition, the introduction of the penalty cost in HPP bidding curves provides the system operator a tool to effectively manage the system-level uncertainty that caused by HPPs. Numerical analysis through Monte Carlo simulations confirms that our bidding curve methodology outperforms the benchmark across various scenarios.

bidding curve↗

Information Systems for Crew-Led Operations Beyond Low-Earth Orbit

On past and present human space missions, the management of vehicle health and status has primarily been executed from Earth. Missions such as Apollo, Space Shuttle, and ISS have relied on a safety net of ground-based experts with access to real-time telemetry data, broad and deep systems expertise, and powerful analytical and computing capabilities. The ground team monitors and manages the vehicle’s health in real-time and responds quickly to critical situations and malfunctions. Ground operators also provide real-time oversight and verbal guidance to flight crew members, especially during complex procedure execution and high-risk activities like extra-vehicular activities. However, this operational paradigm, in place for 60 years, will not transfer to long duration exploration missions beyond low Earth orbit (LEO). Lunar and deep-space crewed missions will encounter delayed communications that prohibit real-time operational and medical support. Additionally, there will be infrequent resupply and a diminished capacity to evacuate or rescue crew members. A small crew must operate independently, managing the vehicle’s state, responding to time-critical events, and executing complex procedures, all without the safety net of real-time support.

data representation↗

Energy Efficiency as a Foundational Technology Pillar for Industrial Decarbonization

The U.S. government aims to achieve net-zero greenhouse gas emissions by 2050 to reduce the severe impacts of climate change. The U.S. industrial sector will become a focal point for decarbonization since it accounts for 33% of the nation’s primary energy use and 30% of its energy-related CO2 emissions. Industrial emissions are also expected to increase by 15% through 2050, making the industrial sector a logical target for decarbonization efforts. Energy efficiency technology pathways provide low-cost, foundational routes to decarbonization that can be implemented immediately. Energy efficiency technology pathways, such as strategic energy management, system efficiency, smart manufacturing, material efficiency, and combined heat and power, are well established and would immediately reduce energy use and emissions. However, their role in the aggressive net-zero decarbonization pathway for the industrial sector is still unclear. This study aims to address energy efficiency pathways for decarbonization, and reviews studies related to these technologies for industrial decarbonization through 2050. This study identifies different strategies for the industrial sector in general and that are specific to six energy-intensive industries: iron and steel; chemical; food and beverage; petroleum refining; pulp and paper; and cement. Finally, a path toward the successful implementation of energy efficiency technologies is outlined.

Strategic energy management↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Renewable energy integration and system operation challenge: control and optimization of millions of devices

The electric power infrastructure, originally designed and built on large-scale power plants, is evolving into a more resilient power generation and delivery system in which millions of smaller units of distributed energy generation resources units will be installed in sub-transmission and distribution networks. In order to control, manage and optimize the future grid, a hierarchical design is presented in this chapter which enables the distributed control on grid edge while inheriting the existing centralized control structure. This layered design of large-scale power system operation and control uses the following principle: reactive power control is treated as a primary control for voltage stability, and the real power control is primarily a grid-level control but can also be a supplementary control for voltage support in the case of insufficient reactive power control capacity. For the purpose of active control and operation at the distribution level, a recursive power network model is derived from nodal injection and branch power flow models. Based on the model, the proposed algorithms of hierarchical control, grid-edge inference and dynamic hosting allowance are developed and presented for multi-level controlled operation. And, a co-simulation architecture of integrated T&D system is presented to validate and demonstrate the feasibility and scalability of proposed algorithms.

Xu, Ying↗

Impact of climate change on water availability and its propagation through the Western U.S. power grid

Climate impact assessment for power systems has tended to focus on the effects of water availability on generation without explicitly considering how these impacts propagate through the interconnected grid to affect generation in other locations. We investigate the impact of projected water availability on the operations of the contemporary Western U.S. power grid, focusing specifically on regional interdependencies. Hydrologic simulations derived from three GCMs (CCSM4, INMCM4 and GFDL-CM3) and two radiative scenarios (RCP4.5 and RCP8.5) are used to force a large-scale, distributed water management model (MOSART-WM), which translates water availability into power generation constraints at hydropower plants and water-dependent thermo-electric plants. Power system dynamics are evaluated using the production cost model PLEXOS. We find that the inter-regional connections across the Western U.S. electricity infrastructure are key in managing drastic variations in regional water availability. Net generation in the Northwest and Northern California is substantially sensitive to local water availability. Generation from the Desert Southwest emerges as a critical resource to compensate for variations in water availability in those regions. Climate change impacts on Northwestern water availability therefore drive future changes in other regions’ generation and regional power flows. The large inter-annual hydrological variability of Northern California exacerbates grid stress arising from long-term changes in water availability in the Northwest. While the regional power flow directions seem insensitive to long-term variations in water availability, the analysis highlights the need to consider other compounding regional factors such as changes in Southern California net load or changes in regional fuel prices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NASA's Evolutionary Xenon Thruster (NEXT) Prototype Model 1R (PM1R) Ion Thruster and Propellant Management System Wear Test Results

The results of the NEXT wear test are presented. This test was conducted with a 36-cm ion engine (designated PM1R) and an engineering model propellant management system. The thruster operated with beam extraction for a total of 1680 hr and processed 30.5 kg of xenon during the wear test, which included performance testing and some operation with an engineering model power processing unit. A total of 1312 hr was accumulated at full power, 277 hr at low power, and the remainder was at intermediate throttle levels. Overall ion engine performance, which includes thrust, thruster input power, specific impulse, and thrust efficiency, was steady with no indications of performance degradation. The propellant management system performed without incident during the wear test. The ion engine and propellant management system were also inspected following the test with no indication of anomalous hardware degradation from operation.

VanNoord, Jonathan L.↗

Overview of the NASA Lewis component technology program for Stirling power converters

This paper presents an update on the NASA Lewis Stirling component technology program. The component technology program has been organized as part of the NASA Lewis effort to develop Stirling converter technology for space power applications. The Stirling space power program is part of the High Capacity Power element of the NASA Civil Space Technology Initiative. Lewis is also providing technical management of a DOE-funded project to develop Stirling converter systems for distributed dish solar terrestrial power applications. The Lewis component technology program is coordinated with the primary contract efforts of these projects but is aimed at longer term issues, advanced technologies, and independent assessments. Topics to be discussed include bearings, linear alternators, controls and load interaction, materials/life assessment, and heat exchangers.

Thieme, Lanny G.↗

Micro-scale Plasma Arc Gasification for Waste Treatment and Energy Production Project

As NASA continues to develop technology for spaceflight beyond low earth orbit, we must develop the right systems for sustaining human life on a long duration or planetary mission. Plasma arc gasification (PAG) is an energy efficient mechanism of waste management for power generation and synthetic gas(syngas) production.

Technology Portfolio System↗

Nuclear Electric Propulsion Brayton Power Conversion Working Fluid Considerations

NASA has considered Nuclear Electric Propulsion (NEP) for high V missions since the late 1950’s, but the current technology readiness level of the requisite powertrain needs to be raised for such a mission. The powertrain includes reactor, power conversion, power management, electric propulsion, and thermal management components that must be integrated to minimize system (kg/kWe) and to finalize a propulsion system architecture within the 2025-2027 timeframe requires advancing these component technologies to technology readiness level (TRL) 5 and Advancement Degree of Difficulty (AD2) 3 in an expeditious manner with minimal risks. This paper will only address the power conversion (heat to electric) components of that system. Based on both internal and industry studies, a primary conclusion of this work is that a single-spool supercritical Xe-He radial flux Brayton heat engine combined with a permanent magnet synchronous alternator can potentially be developed with the least technical risk to meet the technology readiness schedule and required NEP system performance metrics.

Nuclear↗

Baseline Testing of the EV Global E-Bike with Ultracapacitors

The NASA John H. Glenn Research Center initiated baseline testing of the EV Global E-Bike SX with ultracapacitors as a way to reduce pollution in urban areas, reduce fossil fuel consumption, and reduce operating costs for transportation systems. The E-Bike provides an inexpensive approach to advance the state of art in hybrid technology in a practical application. The project transfers space technology to terrestrial use via nontraditional partners, and provides power system data valuable for future space applications. The work was done under the Hybrid Power Management (HPM) Program, which includes the Hybrid Electric Transit Bus (HETB). The E-Bike is a state of the art, ground up, hybrid electrical bicycle. Unique features of the vehicle's power system include the use of an efficient, 400 W electric hub motor, and a seven-speed derailleur system that permits operation as fully electric, fully pedal, or a combination of the two. Other innovative features, such as regenerative braking through ultracapacitor energy storage, are planned. Regenerative braking recovers much of the kinetic energy of the vehicle during deceleration. A description of the E-bike, the results of performance testing, and future vehicle development plans are given in this report. The report concludes that the E-Bike provides excellent performance, and that the implementation of ultracapacitors in the power system can provide significant performance improvements.

Eichenberg, Dennis J.↗