Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “physical exercise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

A Vehicle Management End-to-End Testing and Analysis Platform for Validation of Mission and Fault Management Algorithms to Reduce Risk for NASA's Space Launch System

The development of the Space Launch System (SLS) launch vehicle requires cross discipline teams with extensive knowledge of launch vehicle subsystems, information theory, and autonomous algorithms dealing with all operations from pre-launch through on orbit operations. The characteristics of these systems must be matched with the autonomous algorithm monitoring and mitigation capabilities for accurate control and response to abnormal conditions throughout all vehicle mission flight phases, including precipitating safing actions and crew aborts. This presents a large complex systems engineering challenge being addressed in part by focusing on the specific subsystems handling of off-nominal mission and fault tolerance. Using traditional model based system and software engineering design principles from the Unified Modeling Language (UML), the Mission and Fault Management (M&FM) algorithms are crafted and vetted in specialized Integrated Development Teams composed of multiple development disciplines. NASA also has formed an M&FM team for addressing fault management early in the development lifecycle. This team has developed a dedicated Vehicle Management End-to-End Testbed (VMET) that integrates specific M&FM algorithms, specialized nominal and off-nominal test cases, and vendor-supplied physics-based launch vehicle subsystem models. The flexibility of VMET enables thorough testing of the M&FM algorithms by providing configurable suites of both nominal and off-nominal test cases to validate the algorithms utilizing actual subsystem models. The intent is to validate the algorithms and substantiate them with performance baselines for each of the vehicle subsystems in an independent platform exterior to flight software test processes. In any software development process there is inherent risk in the interpretation and implementation of concepts into software through requirements and test processes. Risk reduction is addressed by working with other organizations such as S&MA, Structures and Environments, GNC, Orion, the Crew Office, Flight Operations, and Ground Operations by assessing performance of the M&FM algorithms in terms of their ability to reduce Loss of Mission and Loss of Crew probabilities. In addition, through state machine and diagnostic modeling, analysis efforts investigate a broader suite of failure effects and detection and responses that can be tested in VMET and confirm that responses do not create additional risks or cause undesired states through interactive dynamic effects with other algorithms and systems. VMET further contributes to risk reduction by prototyping and exercising the M&FM algorithms early in their implementation and without any inherent hindrances such as meeting FSW processor scheduling constraints due to their target platform - ARINC 653 partitioned OS, resource limitations, and other factors related to integration with other subsystems not directly involved with M&FM. The plan for VMET encompasses testing the original M&FM algorithms coded in the same C++ language and state machine architectural concepts as that used by Flight Software. This enables the development of performance standards and test cases to characterize the M&FM algorithms and sets a benchmark from which to measure the effectiveness of M&FM algorithms performance in the FSW development and test processes. This paper is outlined in a systematic fashion analogous to a lifecycle process flow for engineering development of algorithms into software and testing. Section I describes the NASA SLS M&FM context, presenting the current infrastructure, leading principles, methods, and participants. Section II defines the testing philosophy of the M&FM algorithms as related to VMET followed by section III, which presents the modeling methods of the algorithms to be tested and validated in VMET. Its details are then further presented in section IV followed by Section V presenting integration, test status, and state analysis. Finally, section VI addresses the summary and forward directions followed by the appendices presenting relevant information on terminology and documentation.

Trevino, Luis↗

MOD-Amp System Design Spring: Spring 2026 – Georgetown University, SYSM–5620

High-energy lasers (HELs) play an important role in both national defense and scientific research. In defense applications, HELs are used for target detection, tracking, and engagement. In research environments, they support studies of extreme physical conditions relevant to fusion energy and plasma science. These systems depend on the amplification of light through stimulated emission of radiation, allowing optical energy to be increased to the levels required for operation. This amplification occurs when light passes through an energized gain medium that receives energy from an external optical or electrical source. To achieve the desired output, laser systems often use multiple amplification stages, including high-gain preamplifiers and lower-gain power or booster amplifiers. At Lawrence Livermore National Laboratory (LLNL) and other national laboratories, many large-aperture laser amplifier systems are aging and rely on system-specific hardware, obsolete technologies, and incomplete documentation. These legacy systems create challenges for maintenance, supportability, and long-term operation. Their lack of standardization also increases the difficulty of sustaining reliable performance over time. As this infrastructure continues to age, the likelihood of unplanned downtime grows, which can negatively affect both national security missions and scientific research programs that depend on dependable HEL capabilities. The purpose of this document is to demonstrate the application of systems engineering fundamentals and design thinking through the development of a laser amplifier case study. The proposed system concept is intended as an academic exercise and not as a finalized engineering design. As a result, the development presented in this document is incomplete and may contain technical assumptions or errors that would require further investigation before any real-world implementation.

42 ENGINEERING↗

LLNL Results from CALIBAN-PROSPERO Nuclear Accident Dosimetry Experiments in September 2014

Lawrence Livermore National Laboratory (LLNL) uses thin neutron activation foils, sulfur, and threshold energy shielding to determine neutron component doses and the total dose from neutrons in the event of a nuclear criticality accident. The dosimeter also uses a DOELAP accredited Panasonic UD-810 (Panasonic Industrial Devices Sales Company of America, 2 Riverfront Plaza, Newark, NJ 07102, U.S.A.) thermoluminescent dosimetery system (TLD) for determining the gamma component of the total dose. LLNL has participated in three international intercomparisons of nuclear accident dosimeters. In October 2009, LLNL participated in an exercise at the French Commissariat à l’énergie atomique et aux énergies alternatives (Alternative Energies and Atomic Energy Commission- CEA) Research Center at Valduc utilizing the SILENE reactor (Hickman, et.al. 2010). In September 2010, LLNL participated in a second intercomparison at CEA Valduc, this time with exposures at the CALIBAN reactor (Hickman et al. 2011). This paper discusses LLNL’s results of a third intercomparison hosted by the French Institut de Radioprotection et de Sûreté Nucléaire (Institute for Radiation Protection and Nuclear Safety- IRSN) with exposures at two CEA Valduc reactors (CALIBAN and PROSPERO) in September 2014. Comparison results between the three participating facilities is presented elsewhere (Chevallier 2015; Duluc 2015).

61 RADIATION PROTECTION AND DOSIMETRY↗

TA-55 Forensic Support Operations Cross-Training Exercise

As part of the annual FBI/LANL training schedule, a joint training exercise was conducted during the week of 10FEB2020 with FBI HEAT members and LANL Fissile Material Handlers (FMHs). The joint training exercise was conducted in a non-radiological area to reduce cost and ensure the test object would not be contaminated. The exercise test object was fabricated by LANL using surrogate materials to represent an object containing Special Nuclear Material (SNM). Working with Jim Blankenship and Kevin Swearingen, functional requirements of the test object included the following: unclassified, disassembly (to include screws), and moderately heavy. To meet the objectives, the test object was fabricated by welding a custom aluminum box (8” x 8” x 12”) with a lid which was secured by four (4) screws. The custom box housed a track and field shot put (16 lbs.) that was anchored by a hose clamp. The intent of the training was to disassemble the test object and conduct traditional forensic determinations on the parts. This lessons learned report documents all of the associated aspects related to the joint training effort.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

International Nuclear Security Nuclear Material Accounting and Control Instructions for Use and Supplementary Documentation

This document describes the use of exercise kits (called NMAC Kits) developed to support training and technical engagements sponsored by DOE/NNSA Office of Nuclear Security (INS) in the use of nuclear material accounting and control (NMAC) methodologies in support of nuclear security. INS has previously used other similar kits that were originally designed to support NMAC training for international safeguards purposes. These new kits are specifically designed to be used in nuclear security training and emphasis the role NMAC plays in nuclear security as well as security against the insider threat. Planning for the development of these kits is described in LA-UR-24-30063, FY24 NMAC Kits Upgrade and served as the initial framework for the development of the new NMAC Kit material in FY25.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Market Survey 2020: Commercial Clinical Decision Support Systems and Wellness Tools

For long-duration, deep space exploration missions, current methods for managing and supporting crew health and medical conditions will be unsuitable. Communication and data transmission lags will necessitate the use of a sophisticated clinical decision support system (CDSS) that will tailor diagnosis and treatment guidance that is context-sensitive for anticipated astronaut health, wellness, and medical conditions. A variety of clinical decision support (CDS) and wellness tools (WT) are currently available in the commercial market and a broad-brush survey of this market can provide an initial impression of the current state of the art which, in turn, can inform the roadmap of NASA deep space CDSS development and associated requirements. Such a survey was undertaken during the first six months of 2020 using directed convenience sampling to obtain information provided by vendors on their websites; both commercially available CDS and WT (such as those used to track and monitor nutrition, exercise, and sleep) were included. Areas assessed were item type (e.g., software/application, device); primary purpose of the item (e.g., diagnostic support, nutrition tracking); additional purposes (if any); reported features, capabilities, and functionality; setting of use (e.g., inpatient, outpatient); intended user (e.g., clinician, patient); location and sources of data/information used or produced by the item; integration with patient electronic health record (EHR); compliance with interoperability ontologies and standards (e.g., Health Level 7 [HL7], Systematized Nomenclature of Medicine – Clinical Terminology [SNOMED-CT]); and whether the item is knowledge-based (derived from research findings) or non-knowledge-based (derived through artificial intelligence, machine learning, advanced probability and statistics), among others. Ninety-seven (97) vendor websites describing 196 CDS and 73 WT (269 total) were reviewed and coded. The primary purpose of the majority of CDS reviewed is diagnosis or diagnosis/treatment/drug decision support—targeted for clinician use— and the primary purpose of the majority of WT reviewed is the monitoring of different health metrics, most often through the use of a biosensor device (e.g., blood pressure)—targeted for patient use. Very few CDS or WT appear to comply with major international interoperability standards or can be integrated with a patient’s EHR data. None consider contextual factors, such as conditions of the physical environment (e.g., CO2 levels). The majority of CDS and WT reviewed are non-knowledge, cloud- or web-based applications or software. Forty-three (43) major findings were identified and the implications those findings have for NASA will be discussed. Example major findings include: CDS-WT capabilities range from diagnosis to treatment applications, CDS-WT may be wearable or non-wearable and are technologically advanced and only a few CDS-WT tools referenced compliance to ensure interoperability, among other findings. Recommendations will also be offered that will help to address ExMC Gap, Medical-701: Enhance medical capabilities within an exploration medical system.

market survey↗

The Case for a 50+ Year Radioisotope Power System

The Johns Hopkins University Applied Physics Laboratory (JHU/APL) is leading the NASA funded Interstellar Probe study to explore the “Very Local” interstellar medium. To perform this exploration the mission will be required to last at least 50 years in regions of space where solar power is no longer practical. Additionally, several new studies for the National Academies’ Planetary Science and Astrobiology Decadal Survey are planning missions lasting 20-35 years. The Decadal Survey is used to build consensus on priority of national science goals. These proposed missions are inconsistent with the NASA’s current Radioisotope Power Systems (RPS) life requirement of 14 years (flight). Paramount to these proposed long-duration missions are questions about the longevity of such a mission. Evidence exists that space-borne Radioisotope Power Systems can indeed last a long time. LES-9, Voyager I, and Voyager II are over 40 years old, LES-8, Pioneer 10, and Pioneer 11 lasted 28, 30, and 22 years, respectively, and New Horizons is still active 15 years after launch. This paper explores the need for RPS designs that are intended to last much longer than the current requirement of 14 years (17 years after fueling) and explores the historical record for actual vs design lifetimes to show the feasibility of building long lasting RPS. We also exercise a current RTG performance model of the General-Purpose Heat Source RTG using the JPL Lifetime Performance Prediction (LPP) tool to make top-level inferences about power output at end-of-mission, and discusses how reliability engineering and testing methods can be brought to bear to increase confidence in delivering sufficient power at end-of-mission.

Phan, Brian↗

Spectroscopic classification, variability, and SED of the Fermi -detected CSS 3C 286: the radio-loudest NLS1 galaxy?

ABSTRACT 3C 286 is a well-known calibrator source in radio astronomy. It is also one of very few compact steep-spectrum (CSS) sources detected in γ-rays. Here, we perform a detailed spectroscopic and variability analysis and present the first quasi-simultaneous optical to X-ray spectral energy distribution (SED) in order to reveal physical mechanisms that dominate its emission at different wavelengths, and arrive at a reliable optical source classification. The first main result of our study reveals several pitfalls when applying simple broad- or narrow-line Seyfert 1 (BLS1 or NLS1) classification criteria that only look at the [O iii]–Hβ complex. [O iii] and Hβ can be dominated by the same outflow components, in which case full width at half-maximum (Hβ) is no reliable classification criterion, and extinction by intrinsic or intervening material can make the highest velocity Hβ component undetectable. After careful combination of all information from ultraviolet (UV)–optical spectra along with multiwavelength data, we confirm that 3C 286 can be classified as NLS1 galaxy, with line properties and supermassive black hole mass (of order 108 M⊙ and accreting near the Eddington limit) close to the BLS1 regime, making it an important borderline object. The quasi-simultaneous SED taken with Swift shows a sharp rise in the optical–UV, implying the presence of a strong accretion-disc component with extreme UV excess, consistent with emission-line diagnostics. Finally, we report the discovery of X-ray variability of 3C 286, plausibly dominated by jet emission, and variable by at least a factor of ∼4. This result suggests to exercise caution when using 3C 286 as radio calibrator in high-resolution radio very long baseline interferometry observations.

Yao, Su↗

Determination of Critical Experiment Correlations Using the Sampler Sequence Within SCALE 6.2

The validation of neutron transport methods used in nuclear criticality safety analyses is required by consensus American National Standards Institute/American Nuclear Society (ANSI/ANS) standards. In the last decade, there has been an increased interest in correlations among critical experiments used in validation that have shared physical attributes and which impact the independence of each measurement. The statistical methods included in many of the frequently cited guidance documents on performing validation calculations incorporate the assumption that all individual measurements are independent, so little guidance is available to practitioners on the topic. Typical guidance includes recommendations to select experiments from multiple facilities and experiment series in an attempt to minimize the impact of correlations or common-cause errors in experiments. Recent efforts have been made both to determine the magnitude of such correlations between experiments and to develop and apply methods for adjusting the bias and bias uncertainty to account for the correlations. This paper describes recent work performed at Oak Ridge National Laboratory using the Sampler sequence from the SCALE code system to develop experimental correlations using a Monte Carlo sampling technique. Sampler will be available for the first time with the release of SCALE 6.2, and a brief introduction to the methods used to calculate experiment correlations within this new sequence is presented in this paper. Techniques to utilize these correlations in the establishment of upper subcritical limits are the subject of a companion paper and will not be discussed here. Example experimental uncertainties and correlation coefficients are presented for a variety of low-enriched uranium water-moderated lattice experiments selected for use in a benchmark exercise by the Working Party on Nuclear Criticality Safety Subgroup on Uncertainty Analysis in Criticality Safety Analyses. The results include studies on the effect of fuel rod pitch on the correlations, and some observations are also made regarding difficulties in determining experimental correlations using the Monte Carlo sampling technique.

42 ENGINEERING↗

Determination of critical experiment correlations using the sampler sequence within scale 6.2 - 14602

The validation of neutron transport methods used in nuclear criticality safety analyses is required by consensus American National Standards Institute/American Nuclear Society (ANSI/ANS) standards. In the last decade, there has been an increased interest in correlations among critical experiments used in validation that have shared physical attributes and which impact the independence of each measurement. The statistical methods included in many of the frequently cited guidance documents on performing validation calculations incorporate the assumption that all individual measurements are independent, so little guidance is available to practitioners on the topic. Typical guidance includes recommendations to select experiments from multiple facilities and experiment series in an attempt to minimize the impact of correlations or common-cause errors in experiments. Recent efforts have been made both to determine the magnitude of such correlations between experiments and to develop and apply methods for adjusting the bias and bias uncertainty to account for the correlations. This paper describes recent work performed at Oak Ridge National Laboratory using the Sampler sequence from the SCALE code system to develop experimental correlations using a Monte Carlo sampling technique. Sampler will be available for the first time with the release of SCALE 6.2, and a brief introduction to the methods used to calculate experiment correlations within this new sequence is presented in this paper. Techniques to utilize these correlations in the establishment of upper subcritical limits are the subject of a companion paper and will not be discussed here. Example experimental uncertainties and correlation coefficients are presented for a variety of low-enriched uranium water-moderated lattice experiments selected for use in a benchmark exercise by the Working Party on Nuclear Criticality Safety Subgroup on Uncertainty Analysis in Criticality Safety Analyses. The results include studies on the effect of fuel rod pitch on the correlations, and some observations are also made regarding difficulties in determining experimental correlations using the Monte Carlo sampling technique. (authors)

42 ENGINEERING↗

Verification of BOUT++ by the method of manufactured solutions

BOUT++ is a software package designed for solving plasma fluid models. It has been used to simulate a wide range of plasma phenomena ranging from linear stability analysis to 3D plasma turbulence and is capable of simulating a wide range of drift-reduced plasma fluid and gyro-fluid models. A verification exercise has been performed as part of a EUROfusion Enabling Research project, to rigorously test the correctness of the algorithms implemented in BOUT++, by testing order-of-accuracy convergence rates using the Method of Manufactured Solutions (MMS). We present tests of individual components including time-integration and advection schemes, non-orthogonal toroidal field-aligned coordinate systems and the shifted metric procedure which is used to handle highly sheared grids. The flux coordinate independent approach to differencing along magnetic field-lines has been implemented in BOUT++ and is here verified using the MMS in a sheared slab configuration. Finally, we show tests of three complete models: 2-field Hasegawa-Wakatani in 2D slab, 3-field reduced magnetohydrodynamics (MHD) in 3D field-aligned toroidal coordinates, and 5-field reduced MHD in slab geometry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Terry Turbopump Expanded Operating Band Modeling and Simulation Efforts in Fiscal Year 2021 Extended Period of Performance (Final Report)

This report documents the progress made under the Terry Turbine Expanded Operating Band (TTEXOB) program's modeling and simulation (MODSIM) initiative at Sandia National Laboratories (SNL ). It describes the US Federal Fiscal Year 2021 (FY21) extended period-of-performance MODSIM work completed since the closure of FY20 with due reference to the Texas A&M University (TAMU) hybrid milestone 5/6 experimental program. This work, which falls under Milestone 7 of the program, provides a counterpart to the various experiments. The overall TTEXOB program and its milestone-based approach are described in the program's Summary Plan. Details of the individual milestone test plans can be found in the corresponding detailed test plan, e.g. the Milestone 3 and 4 Detailed Test Plan. SNL MODISM is conducted alongside experiments performed at TAMU, and SNL technical staff regularly consults with TAMU on the experimental program. In FY21, MELCOR code models and capabilities were exercised in two different contexts: experimental comparisons to the TAMU ZS-1 and GS-2, and stand-alone analyses of a station black-out (SBO) scenario in a generic boiling water reactor (BWR). Code to experiment comparisons met with fair success when turbine losses were well characterized as for the ZS-1 turbine. Both deterministic and Bayesian calibration processes were used to find a recommended turbine torque multiplier for ZS-1 type turbines. This process could be repeated for GS-2 type turbines if GS-2 losses were better understood. Stand-alone generic BWR SBO calculations revealed that three different modes of self-regulating turbopump behavior may be observed depending on certain modeling parameters and choices having to do with turbine nozzles. Aspects of this predicted behavior may have been observed in TAMU GS-2 experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Trepanning Graphite Samples at a Shutdown Magnox Reactor: A US-UK Joint Exercise for Nuclear Verification

In April 2022, a team sponsored by the US DOE Office of Nuclear Verification (ONV) shipped trepanning equipment to the nuclear power station at Trawsfynydd, Wales, UK to collect samples from the graphite moderator of Reactor 1. The sampling campaign to collect 48 graphite samples was completed in five weeks beginning July 11. Half the samples will be analyzed in the US to determine the total energy production of the facility. The other half will be analyzed by Magnox Ltd. to support decisions for options for the ultimate decommissioning path for the facility. This paper provides a description of the equipment and the operations required to trepan, collect, and package the samples while controlling the small amounts of radioactive graphite dust entrained on and within the tool. The most important sample parameter needed is the precise location of the sample, to within ±6 mm in a fuel channel, while the tool is deployed to between 12 and 20 meters below the operations floor; our means of achieving this precision is given.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

GCSS Idealized Cirrus Model Comparison Project

The GCSS Working Group on Cirrus Cloud Systems (WG2) is conducting a systematic comparison and evaluation of cirrus cloud models. This fundamental activity seeks to support the improvement of models used for climate simulation and numerical weather prediction through assessment and improvement of the "process" models underlying parametric treatments of cirrus cloud processes in large-scale models. The WG2 Idealized Cirrus Model Comparison Project is an initial comparison of cirrus cloud simulations by a variety of cloud models for a series of idealized situations with relatively simple initial conditions and forcing. The models (16) represent the state-of-the-art and include 3-dimensional large eddy simulation (LES) models, two-dimensional cloud resolving models (CRMs), and single column model (SCM) versions of GCMs. The model microphysical components are similarly varied, ranging from single-moment bulk (relative humidity) schemes to fully size-resolved (bin) treatments where ice crystal growth is explicitly calculated. Radiative processes are included in the physics package of each model. The baseline simulations include "warm" and "cold" cirrus cases where cloud top initially occurs at about -47C and -66C, respectively. All simulations are for nighttime conditions (no solar radiation) where the cloud is generated in an ice supersaturated layer, about 1 km in depth, with an ice pseudoadiabatic thermal stratification (neutral). Continuing cloud formation is forced via an imposed diabatic cooling representing a 3 cm/s uplift over a 4-hour time span followed by a 2-hour dissipation stage with no cooling. Variations of these baseline cases include no-radiation and stable-thermal-stratification cases. Preliminary results indicated the great importance of ice crystal fallout in determining even the gross cloud characteristics, such as average vertically-integrated ice water path (IWP). Significant inter-model differences were found. Ice water fall speed is directly related to the shape of the particle size distribution and the habits of the ice crystal population, whether assumed or explicitly calculated. In order to isolate the fall speed effect from that of the associated ice crystal population, simulations were also performed where ice water fall speed was set to the same constant value everywhere in each model. Values of 20 and 60 cm/s were assumed. Current results of the project will be described and implications will be drawn. In particular, this exercise is found to strongly focus the definition of issues resulting in observed inter-model differences and to suggest possible strategies for observational validation of the models. The next step in this project is to perform similar comparisons for well observed case studies with sufficient high quality data to adequately define model initiation and forcing specifications and to support quantitative validation of the results.

Starr, David OC.↗

Improved multiphysics model of the High Temperature Engineering Test Reactor for the simulation of loss-of-forced-cooling experiments

We present a multiphysics model of the High Temperature Engineering Test Reactor for comparison with past and predict future loss-of-forced-cooling (LOFC) experiments. The approach selected combines (1) 3-D full-core superhomogenization-corrected neutronics, (2) 3-D full-core homogenized or semi-heterogeneous heat transfer (macroscale), (3) 2-D axisymmetric fuel rod heat transfer (mesoscale), and (4) 1-D thermal-hydraulics channels. Although large sensitivities remain and the available experimental data are insufficient for use in a rigorous validation exercise, the overall transient behavior is successfully reproduced. The novelty of our work includes (1) a new macroscale-mesoscale heat transfer coupling approach relying on gap conductance to drastically speed up numerical convergence by two orders of magnitude, (2) determination of a radial effective thermal conductivity that yields reasonably close results between the homogenized and semi-heterogeneous macroscale thermal models, and (3) a preliminary study of the reactor's early behavior following a LOFC event, thus enabling further assessment of numerical models against fission power measurements.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Lockout/Tagout (LOTO) Simulator

The Lockout/Tagout (LOTO) Simulator is a portable training aid, or demonstration tool, designed to physically illustrate real-time critical-safety concepts of electrical lockout/tagout. The objective is to prevent misinterpretations of what is off and what is on during maintenance and repair of complex electrical systems. The simulator is designed in the form of a hinged box that opens up and stands on its own as an easel for demonstrations. On the outer face of the unit is a simulated circuit breaker box housing the switches. The breakers control the main power to the unit, a light bulb, and an electrical control cabinet. The light bulb is wired so that either of two breakers can provide power to it. When power is sent to the electrical control cabinet, a red indicator light illuminates. Inside the cabinet is the power supply from a personal computer. The power supply produces a 12-V dc output that is sent over to a small fan next to it, also from a computer, and an amber light on the front of the cabinet illuminates. A separate switch powers the fan on and off. The power supply is behind a plastic shield to protect against exposure to live conductors. Electrical banana jacks are mounted in the plastic shield to allow a voltmeter to be connected safely when opening the cabinet and taking a meter reading to verify de-energization as part of a simulation exercise. This LOTO simulator prototype is designed and fabricated as an all-in-one unit. All accessories can be stored inside the hinged case, and there is a handle on top for ease of transport. The circuit breaker labels attach with hook and loop fasteners so that they may be moved and changed to fit the training or demonstration scenario. The warning signs and labels on the electrical control box are magnetic, allowing for easy reconfiguration to emulate different equipment setups. A specially designed magnetic cover was made to disguise the indicator lights for demonstrations when these indicators are not used. The cover is disguised as an arc flash safety label that would typically be found on such a cabinet. One indicator light has a separate switch that can take it offline. This is to allow for demonstration to trainees on why it is important not to completely rely on indicator lights, but that they should always take a meter reading at the exposed conductors to absolutely verify de-energization before exposure. A clear plastic barrier and banana jacks inside the cabinet provide a safe way to plug in a voltmeter for demonstrations without exposure to the hazards of energized equipment. A small remote control unit is wired into the fan circuit. The remote allows the demonstrator to turn the fan on and off, provided that all of the breakers and switches leading to it are configured on as well. The remote feature was added in order to demonstrate the importance of starting the lockout/tagout task with energized equipment, then powering it down, isolating it, and locking it out to ensure that the correct breakers have been locked out.

Scheer, Jennifer↗

Integration of High Dose Boron Implants--Modification of Device Parametrics through Implant Temperature Control

In the present study, we have extended a previously reported 250 nm logic p-S/D implant (7 keV B 4.5x10{sup 15} cm{sup -2}) process matching exercise [5] to include wafer temperature, and demonstrate that matching can be obtained by increasing the temperature of the wafer during implant. We found that the high dose rate delivered by the single wafer implanter caused the formation of a clear amorphous layer, which upon subsequent annealing altered the diffusion, activation, and clustering properties of the boron. Furthermore, increasing the temperature of the wafer during the implant was sufficient to suppress amorphization, allowing profiles and device parameters to become matched. Figure 5 shows a representative set of curves indicating the cluster phenomena observed for the lower temperature, high flux single wafer implanter, and the influence of wafer temperature on the profiles. The results indicate the strong primary effect of dose rate in determining final electrical properties of devices, and successful implementation of damage engineering using wafer temperature control.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Potential application of LIBS to NNSA next generation safeguards initiative (NGSI)

In a climate in which states and nations have been and perhaps currently are involved in the prol iferation of nuclear materials and technologies, advanced methodologies and improvements in current measurement techniques are needed to combat new threats and increased levels of sophistication. The Department of Energy through the National Nuclear Security Administration (NNSA) has undertaken a broad review of International Safeguards. The conclusion from that review was that a comprehensive initiative to revitalize international safeguards technology and the human resource base was urgently needed to keep pace with demands and increasingly sophisticated emerging safeguards challenges. To address these challenges, NNSA launched the Next Generation Safeguards Initiative (NGSI) to develop policies, concepts, technologies, expertise, and infrastructure necessary to sustain the international safeguards system as its mission evolves for the next 25 years. NGSI is designed to revitalize and strengthen the U.S. safeguards technical base, recognizing that without a robust program the United States of America will not be in a position to exercise leadership or provide the necessary support to the IAEA (International Atomic Energy Agency). International safeguards as administrated by the IAEA are the primary vehicle for verifying compliance with the peaceful use and nonproliferation of nuclear materials and technologies. Laser Induced Breakdown Spectroscopy or LIBS has the potential to support the goals of NGSI as follows: by providing (1) automated analysis in complex nuclear processing or reprocessing facilities in real-time or near real-time without sample preparation or removal, (2) isotopic and important elemental ratio (Cm/Pu, Cm/U, ... etc) analysis, and (3) centralized remote control, process monitoring, and analysis of nuclear materials in nuclear facilities at multiple locations within the facility. Potential application of LIBS to international safeguards as outlined in the NGSI will be discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗