Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Zero-gravity growth of NaF-NaCl eutectics in the NASA Skylab program

Continuous and discontinuous NaF fibers, embedded in a NaCl matrix, were produced in space and on earth. The production of continuous fibers in a eutectic mixture is attributed to the absence of convection current in the liquid during solidification in space. Image transmission and optical transmittance measurements of transverse sections of the space-grown and earth-grown ingots were made with a light microscope and a spectrometer. It is shown that better optical properties were obtained from samples grown in space. This was attributed to a better alignment of NaF fibers along the ingot axis. A new concept is advanced to explain the phenomenon of transmittance versus far infrared wavelength of the directionally solidified NaCl-NaF eutectic in terms of the two-dimensional Bragg Scattering and the polarization effect of Rayleigh scattering. This concept can be applied to other eutectic systems as long as the index of refraction of the matrix over a range of wavelengths is known. Experimental data are in agreement with the theoretical prediction.

Yue, A. S.↗

Zero-gravity growth of NaCl-LiF eutectic. Experiment MA-131

Continuous and discontinuous lithium fluoride fibers embedded in a sodium chloride matrix were produced in space and on earth, respectively. The production of continuous fibers in an eutectic mixture was attributed to the absence of convection current in the liquid during solidification in space. Image transmission and optical transmittance measurements of transverse sections of the space-grown and earth-grown ingots were made with a light microscope and a spectrometer. It was found that better optical properties were obtained from samples grown in space. This was attributed to a better alignment of lithium fluoride fibers along the growth direction.

Yue, A. S.↗

Systematic errors in Hadamard transform optics

Error sources encountered in Hadamard transform optical instruments are discussed. Such errors are caused by factors including moving masks, incorrect mask alignment, defects in mask fabrication, missing data, drifts in background level, and diffraction. Techniques for error reduction and/or elimination are described for each of the cases considered. It is noted that the errors described occur in singly encoded spectrometers and imagers.

Sloane, N. J. A.↗

Zero-gravity growth of a sodium chloride-lithium fluoride eutectic mixture

Continuous and discontinuous lithium fluoride fibers embedded in a sodium chloride matrix were produced in space and on Earth, respectively. The production of continuous fibers in a eutectic mixture was attributed to the absence of convective current in the liquid during solidification in space. Image transmission and optical transmittance measurements of transverse sections of the space-grown and Earth-grown ingots were made with a light microscope and a spectrometer. It was found that better optical properties were obtained from samples grown in space. This was attributed to a better alignment of lithium fluoride fibers along the growth direction.

Yue, A. S.↗

Maintaining Flatness of a Large Aperture Potassium Bromide Beamsplitter Through Mounting and Vibration

The Composite Infrared Spectrometer (CIRS) instrument on the Cassini Mission launched in October of 1997. The CIRS instrument contains a mid-infrared (MIR) and a far-infrared interferometer (FIR) and operates at 170 Kelvin. The MIR is a Michelson Fourier transform spectrometer utilizing a 76 mm (3 inch) diameter potassium bromide beamsplitter and compensator pair. The potassium bromide elements were tested to verify effects of cooldown and vibration prior to integration into the instrument. The instrument was then aligned at ambient temperatures, tested cryogenically and re-verified after vibration. 'Me stringent design optical figure requirements for the beamsplitter and compensator included fabrication errors, mounting stresses and vibration load effects. This paper describes the challenges encountered in mounting the elements to minimize distortion and to survive vibration.

Losch, Patricia↗

Maintaining Flatness of a Large Aperture Potassium Bromide Beamsplitter through Mounting and Vibration

The Composite Infrared Spectrometer (CIRS) instrument on the Cassini Mission launched in October of 1997. The CIRS instrument contains a mid-infrared and a far-infrared interferometer and operates at 170 Kelvin. The mid-infrared interferometer is a Michelson- type Fourier transform spectrometer utilizing a 3 inch diameter potassium bromide beamsplitter/compensator pair. The potassium bromide elements were tested to verify effects of cooldown and vibration prior to integration into the instrument. The instrument was then aligned at ambient temperatures, tested cryogenically and re-verified after vibration. The stringent design optical figure requirements for the beamsplitter and compensator included fabrication errors, mounting stresses and vibration load effects. This paper describes the challenges encountered in mounting the elements to minimize distortion and to survive vibration.

Losch, Patricia↗

Shape of Strained Solid He-4 at Low Temperatures

(1) Interferometer apparatus for measuring surface profile (2) For small strains, the expected linear decrease in height is not seen. (3) For large strains, undulation and irreversible deformations begin to set in, but we cannot yet make clear connection with stress-driven instability theory. Torii and Balibar have observed appearances of deformations beyond threshold stress on He-4 solid surface. The difference of our results from theory real? We are not ready to claim in affirmative. To be able to answer: 1) improve crystal growth techniques; (orientation, annealing, better pressure control) 2) improve homogeneity of stress; (better alignment with vertical, better understanding of interaction between solid He-4 and walls) 4) improve optics.

Kojima, Harry↗

System and Method for Null-Lens Wavefront Sensing

A method of measuring aberrations in a null-lens including assembly and alignment aberrations. The null-lens may be used for measuring aberrations in an aspheric optic with the null-lens. Light propagates from the aspheric optic location through the null-lens, while sweeping a detector through the null-lens focal plane. Image data being is collected at locations about said focal plane. Light is simulated propagating to the collection locations for each collected image. Null-lens aberrations may extracted, e.g., applying image-based wavefront-sensing to collected images and simulation results. The null-lens aberrations improve accuracy in measuring aspheric optic aberrations.

Hill, Peter C.↗

Optical evidence of the chiral magnetic anomaly in the Weyl semimetal TaAs

Chiral pumping from optical electric fields oscillating at terahertz frequencies is observed in the Weyl material TaAs with electric and magnetic fields aligned along both the $\textit{a}$ and $\textit{c}$ axes. In this work, free-carrier spectral weight enhancement is measured directly, confirming theoretical expectations of chiral pumping. A departure from linear field dependence of the Drude weight is observed at the highest fields in the quantum limit, providing evidence of field-dependent Fermi velocity of the chiral Landau level. Implications for the chiral magnetic effect in Weyl semimetals from the optical $\textit{f}$-sum rule are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of Measurement Error Sources in Doppler Global Velocimetry

Doppler global velocimetry uses the absorption characteristics of iodine vapor to provide instantaneous three-component measurements of flow velocity within a plane defined by a laser light sheet. Although the technology is straightforward, its utilization as a flow diagnostics tool requires hardening of the optical system and careful attention to detail during data acquisition and processing if routine use in wind tunnel applications is to be achieved. A development program that reaches these goals is presented. Theoretical and experimental investigations were conducted on each technology element to determine methods that increase measurement accuracy and repeatability. Enhancements resulting from these investigations included methods to ensure iodine vapor calibration stability, single frequency operation of the laser and image alignment to sub-pixel accuracies. Methods were also developed to improve system calibration, and eliminate spatial variations of optical frequency in the laser output, spatial variations in optical transmissivity and perspective and optical distortions in the data images. Each of these enhancements is described and experimental examples given to illustrate the improved measurement performance obtained by the enhancement. The culmination of this investigation was the measured velocity profile of a rotating wheel resulting in a 1.75% error in the mean with a standard deviation of 0.5 m/s. Comparing measurements of a jet flow with corresponding Pitot measurements validated the use of these methods for flow field applications.

Meyers, James F.↗

Computer Vision Techniques Used to Monitor the Alignment of Cavities and Solenoids in the PIP-II Prototype SSR1 Cryomodule

The alignment of the SRF PIP-II string components is studied as the acceptable beam deflection, offset and defocusing, which may otherwise cause beam loss. Simulations and measurements established that the maximum deviation of the beam pipe from the reference orbit should not exceed a small fraction of the beam aperture. To observe the translations and rotations of each single component within the cryomodule, optical instruments (H-BCAM) surveying highly reflective targets, installed in the internal assembly of the module were used. The alignment monitoring concept for the PIP II SSR1 prototype cryomodule, along with relevant measurements of the components’ position monitoring during coldmass cooldown is presented in this contribution. This development paves the way to new computer vision applications in the field of cryomodule assemblies in cleanroom environment, in which robotically-assisted operations have the potential to dramatically reduce the risk of chemical and particulate contamination.

43 PARTICLE ACCELERATORS↗

SIM Narrow and wide angle astrometric demonstration on the MAM testbed.

The Space Interferometry Mission (SIM) requires fringe measurements to the level of picometers in order to produce astrometric data at the micro-arc-second level. To be more specific, it is necessary to measure both the position of the starlight central fringe and the change in the internal optical path of the interferometer to tens of picometers. The internal path is measured with a small heterodyne metrology beam, whereas the starlight fringe position is estimated with a CCD sampling a large concentric annular beam. One major challenge for SIM is to align the metrology beam with the starlight beam to keep the consistency between these two sensors at the system level while articulating the instrument optics over the field of regard. The Micro-Arcsecond Metrology testbed (MAM), developed at the Jet Propulsion Laboratory, features an optical interferometer with a white light source, all major optical components of a stellar interferometer and heterodyne metrology sensors. The setup is installed inside a large vacuum chamber in order to mitigate the atmospheric and thermal disturbances. Astrometric observations are simulated by articulating the optics over the 15 degrees field of regard to generate multiple artificial stars. Recent data show agreement between the metrology and starlight paths to 20pm in the narrow angle field and to 350pm in the full wide angle field of regard of SIM. This paper describes the MAM optical setup, the observation process, the current data and how the performance relates to SIM.

Catanzarite, Joseph H.↗

Development of a mirror pointing mechanism for an atmospheric gas measurement instrument

Development of the Open Path Tunable Infrared Monitor of the Atmosphere (OPTIMA) instrument involved designing a pair of motion systems that could maintain a precise alignment and spatial distance between two mirrors installed on the NASA DC-8 research laboratory aircraft. This is the first airborne optical instrument that allows direct measurement of the gases in the freestream airflow on the exterior of the aircraft. One mirror is mounted within a specially constructed open port cavity in the cabin of the aircraft and the second is mounted 6 meters away on top of the inboard port side (number 2) engine pylon. Three co-aligned laser beams are reflected between the two mirrors 64 times in a Herriott pattern. The resulting sample path length of 384 meters is used to perform a spectral absorption analysis of the airflow between the mirrors. To compensate for normal wing movement and engine oscillations both mirrors were designed as continuously driven mechanisms to maintain alignment within allowable limits. The motion systems of the two mirror assemblies provide five degrees of freedom and are designed to maintain a pointing accuracy within seven arc-sec with a response frequency in excess of 10 Hz. The pylon motion system incorporates controlled pitch and yaw movement. The fuselage motion system compensates for pitch variation as well as linear translation for focal length and vertical aiming of the laser beam via a controlled beam guidance mechanism.

Graham, Michael↗

Development of a Mirror Pointing Mechanism for an Atmospheric Gas Measurement Instrument

Development of the Open Path Tunable Infrared Monitor of the Atmosphere (OPTIMA) instrument involved designing a pair of motion systems that could maintain a precise alignment and spatial distance between two mirrors installed on the NASA DC-8 research laboratory aircraft. This is the first airborne optical instrument that allows direct measurement of the gases in the freestream airflow on the exterior of the aircraft. One mirror is mounted within a specially constructed open port cavity in the cabin of the aircraft and the second is mounted 6 meters away on top of the inboard port side (number 2) engine pylon. Three co-aligned laser beams are reflected between the two mirrors 64 times in a Herriott pattern. The resulting sample path length of 384 meters is used to perform a spectral absorption analysis of the airflow between the mirrors. To compensate for normal wing movement and engine oscillations both mirrors were designed as continuously driven mechanisms to maintain alignment within allowable limits. The motion systems of the two mirror assemblies provide five degrees of freedom and are designed to maintain a pointing accuracy within seven arc-sec with a response frequency in 6xcess of 10 Hz. The pylon motion system incorporates controlled pitch and yaw movement. The fuselage motion system compensates for pitch variation as well as linear translation for focal length and vertical aiming of the laser beam via a controlled beam guidance mechanism.

Graham, Michael↗

Masks For Deposition Of Aspherical Optical Surfaces

Masks of improved design developed for use in fabrication of aspherical, rotationally symmetrical surfaces of mirrors, lenses, and lens molds by evaporative deposition onto rotating substrates. In deposition chamber, source and mask aligned with axis of rotation of substrate. Mask shadows source of rotating substrate. Azimuthal opening (as function of radius) in mask proportional to desired thickness (as function of radius) to which material deposited on substrate. Combination of improved masks and modern coating chambers provides optical surfaces comparable or superior to those produced by conventional polishing, computer-controlled polishing, replication from polished molds, and diamond turning, at less cost in material, labor, and capital expense.

Rogers, John R.↗

STOP Analysis and Optimization of a Very-Low-Distortion Space Instrument: HST WFC3 Case Study

New generation optical instruments with very demanding stability requirements are being proposed and developed for space applications. STOP (Structural-Thermal-Optical Performance) analysis and optimization is crucial in meeting the very tight distortion budgets of these instruments. This presentation outlines STOP analysis and optimization approach in the context of WFC3 (Wide-Field Camera 3), which is a radial instrument designed to replace the Wide-Field Planetary Camera 2 (WFPC2) of the Hubble Space Telescope (HST). WFC3 houses two separate channels, UVIS and IR, and will have greater throughput and sensitivity than WFPC2. WFC3 line-of-sight alignment budget for the UVIS and IR channels are as small as 10 and 20 milli-arcsec, respectively. Its optical bench is the most critical subsystem effecting the optical stability of WFC3 hence our effort concentrates on the design and analysis of the bench and its interfaces. Structural analysis has accompanied the mechanical design of the bench since the initial concept study. A high fidelity structural Finite Element Model (FEM) of the bench has been developed and used for minimizing its thermally induced distortions as well as sizing it to meet the stiffness and strength requirements of a Shuttle launch. The bench is a composite honeycomb panel box structure with a very low planar Coefficient of Thermal Expansion (CTE) of approximately 0.1 ppm/C. Optic components are mounted to super-INVAR inserts bonded into the panels. The bench is kinematically supported on three HST latches via interface struts, which are tailored to exhibit negative CTE to cancel out the thermal motions of the latches. The interface struts also incorporate flexure elements to minimize the mechanical distortions coming into the bench from its enclosure. Bench FEM is coupled with the enclosure FEM to quantify these effects. Short term or on-orbit STOP analysis includes distortion due to the temperature variations of the bench, the struts, and the enclosure. Long term or ground-to-orbit STOP analysis includes distortional effects of gravity release, desorption, and assembly in addition to the ground-to-orbit temperature variations. A rigorous testing program has been implemented for verifying the material properties and the analysis predictions. STOP analysis results demonstrate that both the short-term and the long-term alignment budgets will be met. Presentation will cover design and analysis details that are critical to a successful implementation of the STOP analysis and optimization process.

Kunt, Cengiz↗

Wide angle astrometric demonstration on the micro-arcsecond metrology testbed for the space interferometry mission

The Space Interferometry Mission (SIM) requires fringe measurements to the level of picometers in order to produce astrometric data at the micro-arc-second level. To be more specific, it is necessary to measure both the position of the starlight central fringe and the change in the internal optical path of the interferometer to a few hundreds of picometers. The internal path is measured with a small heterodyne metrology beam, whereas the starlight fringe position is estimated with a CCD sampling a large concentric annular beam. One major challenge for SIM is to align the metrology beam with the starlight beam to keep the consistency between these two sensors at the system level while articulating the instrument optics over the field of view.

metrology↗

Subsystem Imaging Performance and Modeling of the Infrared Multi-Object Spectrograph

The Infrared Multi-Object Spectrograph (IRMOS) is a facility instrument for the Kitt Peak National Observatory Mayall Telescope (3.8 meter). IRMOS is a near-IR (0.8 - 2.5 micron) spectrograph with low to mid resolution (R=lambda/delta, lambda = 300 - 3800). The IRMOS spectrograph produces simultaneous spectra of - 100 objects in its 2.8 x 2.0 arc-min field of view using a commercial MEMS multi-mirror array device (MMA). The IRMOS optical design consists of two imaging systems, or "stages." The focal reducer, stage one, images the focal plane of the telescope onto the MMA. The spectrograph, stage two, images the MMA onto the detector. We describe the breadboard alignment method and imaging and scattered light performance for both the focal reducer and spectrograph. This testing provides verification of the optomechanical alignment method, and a measurement of the contribution of scattered light in the system due to mirror small scale surface error. After the stage I and 2 optics are integrated with the instrument, our test results will make it possible to distinguish between scattered light from the mirrors and the MMA. Image testing will be done at four wavelengths in the visible and near-IR. A mercury-argon pencil lamp will provide spectral lines at 546.1 and 1012 nm, and a blackbody radiation source lines at 1600 and 2200 nm. A CCD camera will be used as a detector for the visible wavelengths, and an IR photodiode will be used for the IR wavelengths. We compare our data with a theoretical analysis using a commercial software package. Mirror surface error is modeled by treating each surface as a superposition of various gratings (e.g., diamond turning tool marks, features due to the impurities of Al 6061, and periodic mid-frequency errors due to drift during machining).

Connelly, Joseph A.↗