IER 557: Godiva IV Reproducibility/Characterization [Slides]

The primary goal of the IER 557 Godiva IV reproducibility/characterization process is to determine reproducibility for 70°C bursts. The secondary goal is to characterize the radiation field, including absolute calibration with radchem counting of fission foils.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

233 U(n,$\gamma$) measurements at LANSCE [Slides]

A new measurement at LANSCE combined DANCE and NEUANCE at the end of 2020 and 2021. The 233 U material was provided by Oak Ridge National Laboratory (December 2020).Two samples of 10 mg and 20 mg of 233 U have been prepared at LANL by Evelyn M. Bond (December 2020). The experiment was performed in December 2020 and June/July 2021. Data analysis is ongoing to extract capture data knowing fission. LANL is looking forward to delivering the capture/fission ratio from (1-300) keV by the end of the FY2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parallel-Plate Avalanche Counter (PPAC) Fabrication for 240 Pu PFNS Measurement [Slides]

A LANL-LLNL joint program has been developed successfully to measure PFNS and established the most precisely determined $\chi$ matrices for 235,238 U and 239 Pu. It has been extended to 240 Pu now and possibly to 233 U in the future. An alternative method was developed to fabricate 240 Pu and a total of 12 targets were made with a total mass of 17.9 mg. The PFNS measurement for 240 Pu will begin in June, 2022 when the new beam cycle starts and the data analysis follows immediately afterward.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the 240 Pu(n,f) Prompt Fission Neutron Spectra with Chi-Nu

The DOE Nuclear Criticality Safety Program has funded a multi-year effort to measure the 240 Pu(n,f) Prompt Fission Neutron Spectrum at Chi-Nu. This project is a joint LANL-LLNL effort, involving the preparation of 12 240 Pu foils and construction of a Parallel-Plate Avalanche Counter at LLNL, with subsequent measurements of the 240 Pu(n,f) PFNS at the Chi-Nu beamline at the Los Alamos Neutron Science Center’s Weapons Neutron Research facility (LANSCE/WNR). We expect the PPAC to be ready in time to perform the measurements this run cycle.

240Pu Foils↗

Chlorine Worth Study in Support of PF-4 Operations [Slides]

The primary concern of this study is if experiments can be designed/conducted to provide technical justification to NCS in order to increase mass limits. This goal is in direct support of 30 pits per year mission, one of the top priorities for NNSA. The accelerated timeline is as follows: Initial tasking, June 2020; preliminary design completion (CED-1 equivalent), November 2020; final design completion (CED-2 equivalent), March 2021; part receipt and inspection completion (CED-3a equivalent), October 2021; experiment execution (CED-3b equivalent), December 2021; experiment documentation write-up completion (start CED-4a equivalent), January 2022; and ICSBEP target (CED-4a equivalent), Fall 2022.

2019 ARCHIMEDES LDRD project↗

Considerations of Radiation-Hardened Electronics for Alpha Detectors in Molten Salt Reactors

Along with advanced generations of reactors quickly becoming reality, the need for instrumentation to provide reliable information for their safety and operation is also becoming relevant. Instrumentation-wise, molten salt reactors (MSRs) represent an especially challenging case in which detectors must survive extreme temperatures, high amounts of radiation, and a highly corrosive coolant. Adding to the complexity, tight material control and accounting must be maintained with any special nuclear material (SNM), a practice made more difficult by the nature of a loop of flowing fuel. Alpha spectroscopy offers a unique window into investigating the isotopic concentrations of actinides within just such a molten salt environment. The characteristic α emissions of specific actinide isotopes in the salt enable quantification of their concentrations. Semiconductor devices based on wide bandgap materials such as silicon carbide and gallium oxide can withstand the extreme temperatures within MSRs and offer good chemical stability with the corrosive salt. Collaborators at The Ohio State University are fabricating and testing a β gallium oxide α particle sensor that could identify actinide concentrations within the fuel salt to help improve the material control and accounting required for complicated system inherent to MSRs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiation Characterization Summary: NETL Beam Port 1/5 Free-Field Environment at the 128-inch Core Centerline Adjacent (NETL-FF-BP1/5-128-cca)

This document presents the facility-recommended characterization of the neutron, prompt gamma ray, and delayed gamma ray radiation fields in the University of Texas at Austin Nuclear Engineering Teaching Laboratory (NETL) TRIGA reactor for the beam port 1/5 free-field environment at the 128-inch location adjacent to the core centerline. The designation for this environment is NETL-FF-BP1/5-128-cca. The neutron, prompt gamma ray, and delayed gamma ray energy spectra, uncertainties, and covariance matrices are presented as well as radial and axial neutron and gamma ray fluence profiles within the experiment area of the cavity. Recommended constants are given to facilitate the conversion of various dosimetry readings into radiation metrics desired by experimenters. Representative pulse operations are presented with conversion examples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of FRAM Measurements to Establish Methodology Uncertainty

Qualification measurements were performed at Oak Ridge National Laboratory (ORNL) on a variety of measurement standards. These measurements will be used to qualify the Fixed-Energy, Response Function Analysis with Multiple Efficiency (FRAM) code with a high purity germanium (HPGe) detector for use at ORNL. Measured items include uranium isotopic standards, U 3 O 8 line sources, and a uranium tetrafluoride source. The 235 U enrichment was estimated using the FRAM isotopic analysis software for each source and compared with the declared isotopic values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of ISOCS Measurements to Establish Methodology Uncertainty

Qualification measurements were performed at the US Department of Energy’s (DOE’s) Oak Ridge National Laboratory (ORNL) on a variety of measurement standards. These measurements will be used to qualify the In-Situ Object Counting System (ISOCS) measurement method with a high-purity germanium (HPGe) detector for use at ORNL. Measured items include uranium isotopic standards, filter papers coated with uranium oxide (U 3 O 8 ), U 3 O 8 line sources, and a uranium tetrafluoride (UF 4 ) source. The 235 U mass was estimated using the ISOCS calibration software for each source and compared with the declared isotope mass value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

UAS Live Incursion Drills Survey

Unmanned aircraft systems (UAS/drones) are rapidly evolving and are considered an emerging threat by nuclear facilities throughout the world. Due to the wide range of UAS capabilities, members of the workforce and security/response force personnel need to be prepared for a variety of drone incursion situations. Tabletop exercises are helpful, but actual live exercises are often needed to evaluate the quick chain of events that might ensue during a real drone fly-in and the essential kinds of information that will help identify the type of drone and pilot. Even with drone detection equipment, the type of UAS used for incursion drills can have a major impact on detection altitude and finding the UAS in the sky. Using a variety of UAS, the U.S. National Nuclear Security Administration (NNSA) Office of International Nuclear Security (INS) would like to offer partners the capability of adding actual UAS into workforce and response exercises to improve overall UAS awareness as well as the procedures that capture critical steps in dealing with intruding drones.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Erratum to: Data Fusion to Support Integrated Nuclear Detonation Detection [Slides]

The original document (LA-UR-22-29547) contained minor equation errors that approximate correct equations that couple the multi-sensor, serial system detector thresholds for a seismic Rayleigh wave detector and an acoustic energy detector. Those errors appeared on slides 62-67. This erratum associates the following slides with the erroneous slides. The numbers of the erroneous slides are marked at the upper right in small text in orange. A result of those errors over-predict the performance of the two-sensor serial network, that is, the former document provides an optimistic estimate of system performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Subcritical Assembly for Training and Education Use at the Oak Ridge National Laboratory [Slides]

Sufficient AGN-201M fuel plate material exists at Y-12 to support the development of a new, inherently safe, subcritical assembly for use in NCS training courses at ORNL. Four experiments with the ORNL subcritical assembly are possible and feasible. Future work includes the final design of the core and reflector and split table component design specifications. The ORNL Material Demonstration Facility (MDF) may be used to 3D print ORSA stand/table components and graphite reflector. Researchers will consider fuel coatings for contamination control, rather than an Al can. A visit to Y-12 will be made to determine the location of AGN fuel plates and remaining fuel transportation considerations. Final facility location will be considered

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing the Performance of Fission Chambers for Local Neutron Flux and Spectrum Measurement

Three fission chambers were tested at The Ohio State University Research Reactor (OSURR) to evaluate fission chambers for neutron flux and spectrum measurements. Two of the fission chambers are commercial Photonis CFUR43 fission chambers—one utilizing highly enriched uranium-235 fissile deposits for thermal neutron detection and the other with highly depleted uranium-238 for fast neutron detection. This experiment was also performed in collaboration with French Alternative Energies and Atomic Energy Commission (CEA) with CEA suppling a uranium-235 loaded fission chamber built from the Photonis CFPR CE8/9 kit. The fission chambers were irradiated in a movable 6.5 inch dry tube at reactor powers of 50 kW, 200 kW, and 450 kW at ambient temperature and at 350°C. While all sensors demonstrated good linear sensitivity to reactor power, a leakage current of 6 nA was measured for the CFUR43 detectors. Additionally, the measured signal ratios of the two CFUR43 detectors did not match the theoretical values and are subject to further investigation on individual signal contributors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Neutron Cross Section Measurements at the RPI LINAC [Slides]

Cold polyethylene shows adequate capacity for enhancing sub-thermal neutron flux. Cold moderator system produced high quality thermal cross section measurements. Measurements were performed for polyethylene, polystyrene, Plexiglas, yttrium hydride and beryllium and compared with ENDF/B-VIII.0 TSL evaluations. All data reduction for all measurements was finalized. Future work includes completion of necessary journal publications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

International Intercomparison for Nuclear Accident Dosimetry Using Godiva-IV

During the week of August 22, 2022, Integral Experiment Request (IER) 538, an international blind intercomparison for nuclear accident dosimetry (NAD) exercise, was completed using the Godiva-IV critical assembly at the National Criticality Experiments Research Center (NCERC) located in the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS). This exercise builds upon a series of experiments that include the characterization the radiation fields around Godiva (IER-147) and Flattop (IER-252) and follow up intercomparisons of dosimetry around both Godiva IV and Flattop (IER-148 and IER-253, respectively). The participants consisted of seven Department of Energy laboratories and one laboratory each from the US Navy, United Kingdom, and France. The participants of the exercise were Lawrence Livermore National Laboratory (LLNL); Los Alamos National Laboratory (LANL); Sandia National Laboratory (SNL); Savannah River Site (SRS); Hanford Site, Missions Support and Test Services (MSTS); Y-12 National Security Complex (Y-12); Naval Dosimetry Center (NDC); Atomic Weapons Establishment (AWE); and Institut de Radioprotection et de Sûreté Nucléaire (IRSN). MSTS dosimeters were included in the irradiations but not reported for evaluation. This report primarily discusses the performance of the 24 hour results submitted by participants, though available final results are briefly discussed. Information for each irradiation performed is provided for participating laboratories to produce their own final report which will be incorporated into the CED-4a report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IER-501 CED-3b: Experiment Execution Summary for the Pulsed-Neutron Die-Away Experimental Testbed for Thermal Scattering Law Benchmarks (PNDA)

This report summarizes the experiments done for IER-501, a testbed for pulsed-neutron die-away (PNDA) experiments at Lawrence Livermore National Laboratory (LLNL). The PNDA experiments were conducted in two separate two-day campaigns: one campaign for high-density polyethylene and another for Lucite. All experiments were performed at Lawrence Livermore Laboratory. They will become high-quality benchmarks that serve to optimize and validate thermal neutron scattering laws (TSLs), which are high priority nuclear data for the Department of Energy’s Nuclear Criticality Safety Program (NCSP). The report presents the PNDA design and its equipment, and it documents the experimental die-away curves. It presents the characterization measurements that have been performed to-date. Importantly, mass spectrometry measurements to determine sample impurities were not yet completed. These will be included in the final benchmark. The report gives the fitted decay constants for the die-away curves of each target sample. It also provides the data for the die-away curves in the appendices. The HDPE experiments examined twelve targets of varying size. The Lucite measurements included ten targets of varying size. Experimenters in the campaign were Daniel Siefman, William Zywiec, and Ruby Araj.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flattop Benchmark CED-2 (IER-423)

The final design for the Flattop HEU Core Benchmark is presented in this report. Physical measurements will be performed on Flattop components using modern instruments and techniques to define uncertainties necessary to meet contemporary ICSBEP standards. A preliminary re-evaluation of ICSBEP HMF-0028 (Flattop HEU Core) led to the development of IER-423 CED-1, wherein total relative uncertainties in $k_{eff}$ were provided based on a new detailed model. The estimated uncertainty on the total uncertainty is +100%/-0%, given a lack of documented uncertainties on mass, dimensions, and densities of predominantly the natural uranium (NU) and highly enriched uranium (HEU) components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IER 268 CED-3b Report

The goal of IER 268 was to collect information from the operation of the Godiva IV super-prompt critical assembly to support multi-physics modeling efforts. There were two types of systems deployed. One was a Photo-Doppler Velocimetry (PDV) system which used the reflection of laser light on the surface of the Godiva IV core. The other consisted of an MHD 240 detector with two other detectors (an MHD-241 and an Eljen EJ-325A) used for reference as the MHD-240 detector was moved. The collection is referred to as the MHD Detector in the narrative log. There were two types of Godiva operations performed to gather data. A series of super-prompt critical bursts were performed and data collected on both systems, tied to a common trigger. Separately, a series of delayed critical operations at various power levels was performed for a combination of MHD detector distances from Godiva and the presence and absence of a shield in the line of sight between Godiva and the MHD detector. This data was collected to determine the contribution of room return during the burst measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗