Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

TU-H-206-01: An Automated Approach for Identifying Geometric Distortions in Gamma Cameras

Purpose: To develop a clinically-deployable, automated process for detecting artifacts in routine nuclear medicine (NM) quality assurance (QA) bar phantom images. Methods: An artifact detection algorithm was created to analyze bar phantom images as part of an ongoing QA program. A low noise, high resolution reference image was acquired from an x-ray of the bar phantom with a Philips Digital Diagnost system utilizing image stitching. NM bar images, acquired for 5 million counts over a 512×512 matrix, were registered to the template image by maximizing mutual information (MI). The MI index was used as an initial test for artifacts; low values indicate an overall presence of distortions regardless of their spatial location. Images with low MI scores were further analyzed for bar linearity, periodicity, alignment, and compression to locate differences with respect to the template. Findings from each test were spatially correlated and locations failing multiple tests were flagged as potential artifacts requiring additional visual analysis. The algorithm was initially deployed for GE Discovery 670 and Infinia Hawkeye gamma cameras. Results: The algorithm successfully identified clinically relevant artifacts from both systems previously unnoticed by technologists performing the QA. Average MI indices for artifact-free images are 0.55. Images with MI indices < 0.50 have shown 100% sensitivity and specificity for artifact detection when compared with a thorough visual analysis. Correlation of geometric tests confirms the ability to spatially locate the most likely image regions containing an artifact regardless of initial phantom orientation. Conclusion: The algorithm shows the potential to detect gamma camera artifacts that may be missed by routine technologist inspections. Detection and subsequent correction of artifacts ensures maximum image quality and may help to identify failing hardware before it impacts clinical workflow. Going forward, the algorithm is being deployed to monitor data from all gamma cameras within our health system.

60 APPLIED LIFE SCIENCES↗

Comparing modern measurements of the {sup 11}B(d,n{gamma}{sub 15.1}){sup 12}C excitation function with previous values

A possible means of active interrogation of special nuclear materials is detection of signature emissions following induced photofission. This method requires a probe gamma-ray beam to induce the photofission. The {sup 11}B(d,n{gamma}{sub 15.1}){sup 12}C reaction is a candidate for the source of this probe beam. The reaction is prolific and the produced 15.1 MeV gamma-ray is close to a photofission cross-section peak for {sup 235,238}U and {sup 238,239}Pu. In order to model an active interrogation system using the {sup 11}B(d,n{gamma}{sub 15.1}){sup 12}C reaction as a source probe an accurate value for its differential crosssection must be included in data libraries. Measurements of the differential cross-section for the {sup 11}B(d,n{gamma}{sub 15.1}){sup 12}C reaction have been carried out with a BGO detector and found to differ from previous measurements reported by Kavanagh (1958) and Kuan (1964). The discrepancy in the measurements may be explained by examining the detector response function used by Kavanagh and presumably Kuan to that modeled with MCNP5. A comparison of the MCNP5 and Kavanagh detector response functions normalized to the 15.1 MeV gamma-ray peak pulse height shows a factor of approximately 1.7 difference in integrated counts. Applying this correction to the differential cross-section previously reported by Kuan brings the values into agreement, within uncertainties, to the more recent measurements. The evaluation of the detector response function for the 15.1 MeV gamma-ray signal in the NaI detector reported by Kavanagh to that modeled by MCNP5 is shown. This result is applied to the comparison of recent measurements on the {sup 11}B(d,n{gamma}{sub 15.1}){sup 12}C reaction differential cross-section to those previously reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The denatured state of HIV ‐1 protease under native conditions

Abstract The denatured state of several proteins has been shown to display transient structures that are relevant for folding, stability, and aggregation. To detect them by nuclear magnetic resonance (NMR) spectroscopy, the denatured state must be stabilized by chemical agents or changes in temperature. This makes the environment different from that experienced in biologically relevant processes. Using high‐resolution heteronuclear NMR spectroscopy, we have characterized several denatured states of a monomeric variant of HIV‐1 protease, which is natively structured in water, induced by different concentrations of urea, guanidinium chloride, and acetic acid. We have extrapolated the chemical shifts and the relaxation parameters to the denaturant‐free denatured state at native conditions, showing that they converge to the same values. Subsequently, we characterized the conformational properties of this biologically relevant denatured state under native conditions by advanced molecular dynamics simulations and validated the results by comparison to experimental data. We show that the denatured state of HIV‐1 protease under native conditions displays rich patterns of transient native and non‐native structures, which could be of relevance to its guidance through a complex folding process.

60 APPLIED LIFE SCIENCES↗

Radioxenon production through neutron irradiation of stable xenon gas

The Spectral Deconvolution Analysis Tool (SDAT) software was developed to improve counting statistics and detection limits for nuclear explosion radionuclide measurements. SDAT utilizes spectral deconvolution spectroscopy techniques and can analyze both β-γ coincidence spectra for radioxenon isotopes and high-resolution HPGe spectra from aerosol monitors. The deconvolution algorithm of the SDAT requires a library of β-γ coincidence spectra of individual radioxenon isotopes to determine isotopic ratios in a sample. In order to get experimentally produced spectra of the individual isotopes we have irradiated enriched samples of 130Xe, 132Xe, and 134Xe gas with a neutron beam from the TRIGA reactor at The University of Texas. The samples produced were counted in an Automated Radioxenon Sampler/Analyzer (ARSA) style β-γ coincidence detector. The spectra produced show that this method of radioxenon production yields samples with very high purity of the individual isotopes for 131mXe and 135Xe and a sample with a substantial 133mXe to 133Xe ratio.

ARSA↗

Adsorption of Tracer Gases in Geological Media: Experimental Benchmarking

The interaction of xenon with containment barriers can play a crucial role in the detection of underground nuclear explosions. Independent field experiments and laboratory-derived models have observed depressed surface level xenon concentrations and subsequently predicted geological capture rates. This work sought to experimentally verify those predictions by analyzing xenon transport though a two-bulb diffusion apparatus adapted for the study of geologic media. Novel to this work is the timescale over which these experiments were carried out, allowing the system to reach equilibrium, rather than relying on numerical models to treat the equilibrium concentration of each gas as a fit coefficient.

Byers, Maggie↗

Effect of green light spectra on the reduction of retinal damage and stress in goldfish, Carassius auratus

We investigated the effect of light spectra on retinal damage and stress in goldfish using green (530 nm) and red (620 nm) light emitting diodes (LEDs) at three intensities each (0.5, 1.0, and 1.5 W/m{sup 2}). We measured the change in the levels of plasma cortisol and H{sub 2}O{sub 2} and expression and levels of caspase-3. The apoptotic response of green and red LED spectra was assessed using the terminal transferase dUTP nick end labeling (TUNEL) assay. Stress indicator (cortisol and H{sub 2}O{sub 2}) and apoptosis-related genes (caspase-3) decreased in green light, but increased in red light with higher light intensities over time. The TUNEL assay revealed that more apoptotic cells were detected in outer nuclear layers after exposure to red LED over time with the increase in light intensity, than the other spectra. These results indicate that green light efficiently reduces retinal damage and stress, whereas red light induces it. Therefore, red light-induced retina damage may induce apoptosis in goldfish retina. -- Highlights: •Green light efficiently reduces retinal damage and stress. •Green spectra reduce caspase production and apoptosis. •Red light-induced retina damage may induce apoptosis in goldfish retina. •The retina of goldfish recognizes green spectra as a stable environment.

60 APPLIED LIFE SCIENCES↗

Source Term Estimates of Radioxenon Released from the BaTek Medical Isotope Production Facility Using External Measured Air Concentrations

Abstract Batan Teknologi (BaTek) operates an isotope production facility in Serpong, Indonesia that supplies 99mTc for use in medical procedures. Atmospheric releases of Xe-133 in the production process at BaTek are known to influence the measurements taken at the closest stations of the International Monitoring System (IMS). The purpose of the IMS is to detect evidence of nuclear explosions, including atmospheric releases of radionuclides. The xenon isotopes released from BaTek are the same as those produced in a nuclear explosion, but the isotopic ratios are different. Knowledge of the magnitude of releases from the isotope production facility helps inform analysts trying to decide whether a specific measurement result came from a nuclear explosion. A stack monitor deployed at BaTek in 2013 measured releases to the atmosphere for several isotopes. The facility operates on a weekly cycle, and the stack data for June 15-21, 2013 show a release of 1.84E13 Bq of Xe-133. Concentrations of Xe-133 in the air are available at the same time from a xenon sampler located 14 km from BaTek. An optimization process using atmospheric transport modeling and the sampler air concentrations produced a release estimate of 1.88E13 Bq. The same optimization process yielded a release estimate of 1.70E13 Bq for a different week in 2012. The stack release value and the two optimized estimates are all within 10 percent of each other. Weekly release estimates of 1.8E13 Bq and a 40 percent facility operation rate yields a rough annual release estimate of 3.7E13 Bq of Xe-133. This value is consistent with previously published estimates of annual releases for this facility, which are based on measurements at three IMS stations. These multiple lines of evidence cross-validate the stack release estimates and the release estimates from atmospheric samplers.

atmospheric modeling↗

ULTRALUMINOUS X-RAY SOURCES IN ARP 147

The Chandra X-Ray Observatory was used to image the collisional ring galaxy Arp 147 for 42 ks. We detect nine X-ray sources with luminosities in the range of (1.4-7) x 10{sup 39} erg s{sup -1} (assuming that the sources emit isotropically) in or near the blue knots of star formation associated with the ring. A source with an X-ray luminosity of 1.4 x 10{sup 40} erg s{sup -1} is detected in the nuclear region of the intruder galaxy. X-ray sources associated with a foreground star and a background quasar are used to improve the registration of the X-ray image with respect to Hubble Space Telescope (HST) high-resolution optical images. The intruder galaxy, which apparently contained little gas before the collision, shows no X-ray sources other than the one in the nuclear bulge which may be a poorly fed supermassive black hole. These observations confirm the conventional wisdom that collisions of gas-rich galaxies trigger large rates of star formation which, in turn, generate substantial numbers of X-ray sources, some of which have luminosities above the Eddington limit for accreting stellar-mass black holes (i.e., ultraluminous X-ray sources, 'ULXs'). We also utilize archival Spitzer and Galex data to help constrain the current star formation rate in Arp 147 to {approx}7 M{sub sun} yr{sup -1}. All of these results, coupled with binary evolution models for ULXs, allow us to tentatively conclude that the most intense star formation may have ended some 15 Myr in the past.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved measurement of the reactor antineutrino flux and spectrum at Daya Bay

Here, a new measurement of the reactor antineutrino flux and energy spectrum by the Daya Bay reactor neutrino experiment is reported. The antineutrinos were generated by six 2.9 GW th nuclear reactors and detected by eight antineutrino detectors deployed in two near (560 m and 600 m flux-weighted baselines) and one far (1640 m flux-weighted baseline) underground experimental halls. With 621 days of data, more than 1.2 million inverse beta decay (IBD) candidates were detected. The IBD yield in the eight detectors was measured, and the ratio of measured to predicted flux was found to be 0.946 ± 0.020 (0.992 ± 0.021) for the Huber+Mueller (ILL+Vogel) model. A 2.9σ deviation was found in the measured IBD positron energy spectrum compared to the predictions. In particular, an excess of events in the region of 4$-$6 MeV was found in the measured spectrum, with a local significance of 4.4σ. Finally, a reactor antineutrino spectrum weighted by the IBD cross section is extracted for model-independent predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New Constraints on Cosmic Ray-Boosted Dark Matter from the LUX-ZEPLIN Experiment

While dual-phase xenon time projection chambers have driven the sensitivity toward weakly interacting massive particles at the GeV/c 2 to TeV/c 2 mass scale, the scope for sub-GeV/c 2 dark matter particles is hindered by a limited nuclear recoil energy detection threshold. One approach to probe for lighter candidates is to consider cases where they have been boosted by collisions with cosmic rays in the Milky Way, such that the additional kinetic energy lifts their induced signatures above the nominal threshold. In this Letter, we report first results of a search for cosmic ray-boosted dark matter (CRDM) with a combined 4.2 metric ton/yr exposure from the LUX-ZEPLIN experiment. We observe no excess above the expected backgrounds and establish world-leading constraints on the spin-independent CRDM-nucleon cross section as small as 3.9×10 −33 cm 2 at 90% confidence level for sub-GeV/c 2 masses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effective theory of Dirac dark matter

A stable Dirac fermion with four-fermion interactions to leptons suppressed by a scale {lambda}{approx}1 TeV is shown to provide a viable candidate for dark matter. The thermal relic abundance matches cosmology, while nuclear recoil direct detection bounds are automatically avoided in the absence of (large) couplings to quarks. The annihilation cross section in the early Universe is the same as the annihilation in our Galactic neighborhood. This allows Dirac fermion dark matter to naturally explain the positron ratio excess observed by PAMELA with a minimal boost factor, given present astrophysical uncertainties. We use the Galprop program for propagation of signal and background; we discuss in detail the uncertainties resulting from the propagation parameters and, more importantly, the injected spectra. Fermi/GLAST has an opportunity to see a feature in the gamma-ray spectrum at the mass of the Dirac fermion. The excess observed by ATIC/PPB-BETS may also be explained with Dirac dark matter that is heavy. A supersymmetric model with a Dirac bino provides a viable UV model of the effective theory. The dominance of the leptonic operators, and thus the observation of an excess in positrons and not in antiprotons, is naturally explained by the large hypercharge and low mass of sleptons as compared with squarks. Minimizing the boost factor implies the right-handed selectron is the lightest slepton, which is characteristic of our model. Selectrons (or sleptons) with mass less than a few hundred GeV are an inescapable consequence awaiting discovery at the LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Minimal Supergravity Scalar Neutrino Dark Matter and Inverse Seesaw Neutrino Masses

We show that within the inverse seesaw mechanism for generating neutrino masses, minimal supergravity naturally provides the scalar neutrino as the lightest superparticle. We also demonstrate that such schemes naturally reconcile the small neutrino masses with the correct relic scalar neutrino dark matter abundance and accessible direct detection rates in nuclear recoil experiments. This way, inverse seesaw minimal supergravity offers a common solution to the generation of the neutrino mass and to the origin of dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Adsorptive Transport of Noble Gas Tracers in Porous Media

The transport of noble gas radionuclides in porous media is relevant to the detection of underground nuclear detonations as well as the sequestration of reprocessing off-gases. However, in field tests releasing radioxenon underground, the quantity of radioxenon observed at the surface has fallen well below expectations1. This study examined the diffusivity of noble gases (Kr and Xe) and the inert molecular gas sulfur hexafluoride (SF6) in porous media to observe any unexpected behavior. To replicate the transport of radiogenic noble gases in underground media, a two-bulb gaseous diffusion apparatus was constructed. The two bulbs are connected with a column of 10-30 Ottawa sand and ordinary atmosphere filled both the bulbs and pore spaces. The tracer gases were diluted in an isolated bulb to approximately 1000 ppm. Once released, the gases were allowed to diffuse through the column. Aliquots were withdrawn at regular time intervals from both bulbs and concentrations were quantified using a Shimadzu QP2010 SE gas chromatograph-mass spectrometer. The effective diffusivity was then calculated using a maximum likelihood estimate on the quasi-steady state model.

Paul, Matthew R.↗

DarkSide: Latest results and future perspectives

DarkSide is direct-detection dark-matter experimental project based on radiopure argon. The main goal of the DarkSide program is the detection of rare nuclear elastic collisions with hypothetical dark-matter particles. The present detector, DarkSide-50, placed at Laboratori Nazionali del Gran Sasso (LNGS), is a dualphase time projection chamber (TPC) filled with ultra-pure liquid argon, extracted from underground sources. Surrounding the TPC to suppress the background there are neutron and muon active vetoes. One of argon key features is the capability to distinguish between electron and nuclear recoils, exploiting the different shapes of the signals. DarkSide-50 new results, obtained using a live-days exposure of 532.4 days, are presented. This analysis sets a 90% C.L. upper limit on the dark matter-nucleon spin-independent cross-section of 1.1 × 10 -44 cm 2 for a WIMP mass of 100 GeV/c 2 . The next phase of the project, DarkSide-20k, will be a new detector with a fiducial mass of ~ 20 tons, equipped with cryogenic silicon photomultipliers (SiPM).

79 ASTRONOMY AND ASTROPHYSICS↗

Significantly Improving Regional Seismic Amplitude Tomography at Higher Frequencies by Determining S -Wave Bandwidth

Characterizing regional seismic signals continues to be a difficult problem due to their variability. Calibration of these signals is very important to many aspects of monitoring underground nuclear explosions, including detecting seismic signals, discriminating explosions from earthquakes, and reliably estimating magnitude and yield. Amplitude tomography, which simultaneously inverts for source, propagation, and site effects, is a leading method of calibrating these signals. A major issue in amplitude tomography is the data quality of the input amplitude measurements. Pre-event and prephase signal-to-noise ratio (SNR) tests are typically used but can frequently include bad signals and exclude good signals. The deficiencies of SNR criteria, which are demonstrated here, lead to large calibration errors. To ameliorate these issues, we introduce a semi-automated approach to assess the bandwidth of a spectrum where it behaves physically. We determine the maximum frequency (denoted as F max ) where it deviates from this behavior due to inflections at which noise or spurious signals start to bias the spectra away from the expected decay. We compare two amplitude tomography runs using the SNR and new F max criteria and show significant improvements to the stability and accuracy of the tomography output for frequency bands higher than 2 Hz by using our assessments of valid S-wave bandwidth. We compare Q estimates, P/S residuals, and some detailed results to explain the improvements. Lastly, for frequency bands higher than 4 Hz, needed for effective P/S discrimination of explosions from earthquakes, the new bandwidth criteria sufficiently fix the instabilities and errors so that the residuals and calibration terms are useful for application.

58 GEOSCIENCES↗

Technical Advice and Support for the Joint Integrated Non-Intrusive Inspection (JINII) Program Task 2.2 Transmission Digital Radiography (DR)

The Cargo Advanced Automated Radiography System (CAARS) program aims to utilize advanced radiographic systems to detect radiological and nuclear threats. Validation of initial design and testing concepts is a precondition for prototype system development and large-scale deployment. As expected, Depleted Uranium (DU) is a valid surrogate for Special Nuclear Materials (SNM) in CAARS Advanced Technology Demonstration (ATD) performance field-tests of transmission radiography systems. Dual-energy transmission measurements of DU are nearly identical to SNM, and are distinct from lower Z materials, provided the samples are matched to equal areal density. Results from an alternative method, using samples of equal thickness, showed sample discrimination by material density, rather than by atomic number (Z). The transmission measurements of DU and SNM were made with equipment that is nearly identical to current field systems. X-ray source beams at endpoint energies of 5.4 MeV and 9.6 MeV were used to measure transmission through the selected sample materials. The ratio of the x-ray linear attenuation coefficient times length ({micro}L) at 5.4 MeV, to {micro}L at 9.6 MeV is a metric for atomic number based discrimination of materials. The measured ratios were compared with computed values based on LLNL photon cross section data and LLNL developed models of x-ray detector characteristics. Measured ratios for DU differed from HEU by an average of 0.25%, and from WGPu by 0.08%, which is within the noise level of 0.4 to 0.5%. For comparison, measured ratios for Sn differed from HEU by 3.2%, and from WGPu by 3.6%, well beyond the measurement noise. Measured ratios for W differed from HEU by 0.01%, and from WGPu by 0.32%. The measured ratio values presented in Table 1 demonstrate the feasibility of using a threshold ratio to discriminate low-Z (Z < 72) from high-Z (Z {ge} 72) materials (as defined by CAARS specification). In the case of our test system, a threshold ratio of 1.08 would be suitable based on the measured results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗