Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiple precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Subsecond and Submillimeter Resolution Positional Verification for Stereotactic Irradiation of Spinal Lesions

Purpose: Spine stereotactic body radiation therapy (SBRT) requires highly accurate positioning. We report our experience with markerless template matching and triangulation of kilovoltage images routinely acquired during spine SBRT, to determine spine position. Methods and Materials: Kilovoltage images, continuously acquired at 7, 11 or 15 frames/s during volumetric modulated spine SBRT of 18 patients, consisting of 93 fluoroscopy datasets (1 dataset/arc), were analyzed off-line. Four patients were immobilized in a head/neck mask, 14 had no immobilization. Two-dimensional (2D) templates were created for each gantry angle from planning computed tomography data and registered to prefiltered kilovoltage images to determine 2D shifts between actual and planned spine position. Registrations were considered valid if the normalized cross correlation score was ≥0.15. Multiple registrations were triangulated to determine 3D position. For each spine position dataset, average positional offset and standard deviation were calculated. To verify the accuracy and precision of the technique, mean positional offset and standard deviation for twenty stationary phantom datasets with different baseline shifts were measured. Results: For the phantom, average standard deviations were 0.18 mm for left-right (LR), 0.17 mm for superior-inferior (SI), and 0.23 mm for the anterior-posterior (AP) direction. Maximum difference in average detected and applied shift was 0.09 mm. For the 93 clinical datasets, the percentage of valid matched frames was, on average, 90.7% (range: 49.9-96.1%) per dataset. Average standard deviations for all datasets were 0.28, 0.19, and 0.28 mm for LR, SI, and AP, respectively. Spine position offsets were, on average, −0.05 (range: −1.58 to 2.18), −0.04 (range: −3.56 to 0.82), and −0.03 mm (range: −1.16 to 1.51), respectively. Average positional deviation was <1 mm in all directions in 92% of the arcs. Conclusions: Template matching and triangulation using kilovoltage images acquired during irradiation allows spine position detection with submillimeter accuracy at subsecond intervals. Although the majority of patients were not immobilized, most vertebrae were stable at the sub-mm level during spine SBRT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Meta-Optical Chirality and Emergent Eigen-polarization Modes via Plasmon Interactions

The response of an individual meta-atom is often generalized to explain the collective response of a metasurface in a manner that neglects the interactions between meta-atoms. Here, we study a metasurface composed of tilted achiral meta-atoms with no spatial variation of the unit cell that derives appreciable optical chirality solely from the asymmetric interactions between meta-atoms. The interactions between meta-atoms are considered to stem from the Lorentz force arising from the Larmor radiation of adjacent plasmonic resonators because their inclusion in a simple model accurately predicts the bonding/anti- bonding modes that are measured experimentally. We also experimentally observe the emergence of multiple polarization eigenmodes, among other polarization-dependent responses, which cannot be modeled with the conventional formalism of transmission matrices. Our results are vital to the precise characterization and design of metasurfaces.

36 MATERIALS SCIENCE↗

Reaction cross section studies at NIRS and RIBF

Reaction cross sections for stable nuclei at intermediate energies have been measured precisely and systematically. The data have been found to be reproduced nicely by the optical-limit approximation of Glauber theory modified to include the nucleon multiple scattering effect and the Fermi-motion effect. Applying this prescription, the nucleon density distribution of {sup 17}Ne has been studied. The surface structure of {sup 8}B and {sup 11}Be has been also studied using this prescription and hydrogen targets. Using the RIBF that has just started application to studies of exotic nuclei, neutron-rich Ne isotopes around the Island of Inversion have been investigated through measurements of their interaction cross sections.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modular repeat protein sculpting using rigid helical junctions

The ability to precisely design large proteins with diverse shapes would enable applications ranging from the design of protein binders that wrap around their target to the positioning of multiple functional sites in specified orientations. We describe a protein backbone design method for generating a wide range of rigid fusions between helix-containing proteins and use it to design 75,000 structurally unique junctions between monomeric and homo-oligomeric de novo designed and ankyrin repeat proteins (RPs). Of the junction designs that were experimentally characterized, 82% have circular dichroism and solution small-angle X-ray scattering profiles consistent with the design models and are stable at 95 °C. Crystal structures of four designed junctions were in close agreement with the design models with rmsds ranging from 0.9 to 1.6 Å. Electron microscopic images of extended tetrameric structures and ~10-nm-diameter “L” and “V” shapes generated using the junctions are close to the design models, demonstrating the control the rigid junctions provide for protein shape sculpting over multiple nanometer length scales.

59 BASIC BIOLOGICAL SCIENCES↗

Measurement of directed flow in Au + Au collisions at $\sqrt{s{NN}}$ = 19.6 and 27 GeV with the STAR event plane detector

In heavy-ion collision experiments, the global collectivity of final-state particles can be quantified by anisotropic flow coefficients (𝑣 𝑛 ) . The first-order flow coefficient, also referred to as the directed flow (𝑣 1 ), describes the collective sideward motion of produced particles and nuclear fragments in heavy-ion collisions. It carries information on the very early stage of the collision, especially at large pseudorapidity (𝜂), where it is believed to be generated during the nuclear passage time. Directed flow therefore probes the onset of bulk collective dynamics during thermalization, providing valuable experimental guidance to models of the pre-equilibrium stage. In 2018, the Event Plane Detector (EPD) was installed in STAR and used for the Beam Energy Scan phase-II (BES-II) data taking. The combination of EPD (2.1 < |𝜂| < 5.1) and high-statistics BES-II data enables us to extend the 𝑣 1 measurement to the forward and backward 𝜂 regions. In this paper, we present the measurement of 𝑣 1 over a wide 𝜂 range in Au + Au collisions at $\sqrt{s_{NN}}$ = 19.6 and 27 GeV using the STAR EPD. The results of the analysis at $\sqrt{s_{NN}}$ = 19.6 GeV exhibit excellent consistency with the previous PHOBOS measurement, while elevating the precision of the overall measurement. The increased precision of the measurement also revealed finer structures in heavy-ion collisions, including a potential observation of the first-order event-plane decorrelation. Multiple physics models were compared to the experimental results. Only a transport model and a three-fluid hybrid model can reproduce a sizable 𝑣 1 at large 𝜂 as was observed experimentally. The model comparison also indicates 𝑣 1 at large 𝜂 might be sensitive to the QGP phase transition.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dedicated short range communications used as fail-safe in autonomous navigation

Here in this paper, we have analyzed scenarios for leader-follower vehicle convoys that have the potential to be unsafe, hazardous, or even fatal in order to provide insight on dangerous driving conditions for autonomous vehicle platoons. These scenarios were created in a simulation software called Prescan, and are made to reflect the behavior of the vehicle dynamics and sensor characteristics of a real-world vehicle convoy that is currently being tested at the American Center for Mobility (ACM) and sponsored by the Department of Energy (DOE), National Renewable Energy Laboratory (NREL), the U.S. Army Combat Capabilities Development Command - Ground Vehicle Systems Center (U.S. Army CC-DEVCOM) and the Michigan Department of Transportation (MDOT). The follower vehicle in this study is tested under multiple scenarios, equipped with a Dedicated Short Range vehicle-to-vehicle communication system (DSRC), a radar-based adaptive cruise control system (ACC) and a precision global positioning system (GPS).

42 ENGINEERING↗

Spatial and Temporal Characterization of Polarization Entanglement

We describe the full temporal and spatial characterization of polarization-entangled photons produced by Spontaneous Parametric Down Conversions using an intensified high-speed optical camera, Tpx3Cam. This novel technique allows for precise determination of Bell inequality parameters and for new characterization methods for the spatial distribution of entangled quantum information. We also discuss a technique to synchronize multiple cameras separated by vast distances, which will be required for a distributed quantum network.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multi-path peristaltic pump

The instant invention is directed to a peristaltic pump for critical laboratory or hospital applications requiring precise flow rates over an extended period of time. Within the cylindrical barrel pump housing is a single-piece, molded, elastometric, cylindrical liner with a multiplicity of flattened helical channels created therein from one end of the liner to the other. Three cylindrical rollers rotate about the center axis of the pump around the inside surface of the liner selectively compressing the liner, and hence the helical channels between the rollers and the barrel housing, creating a pumping action by forcing trapped fluid in the helical channels axially from one end of the liner to the opposite end. The novelty of the invention appears to lie in the provision of the special liner with multiple helical channels as the pumping chamber, rather than the standard single elastomeric tubing which is squeezed repeatedly by rollers to move the liquid through a typical peristaltic pump. Large, repeated deflections on the standard tubing causes a permanent set in the tubing, thus either changing the flow rate, or requiring a new section of tubing to be positioned in the pump head. Further, this configuration minimizes the amount of outflow pulsation which is characteristic of a typical single tubing peristaltic pump.

Chandler, Joseph A.↗

A GPS measurement system for precise satellite tracking and geodesy

NASA is pursuing two key applications of differential positioning with the Global Positioning System (GPS): sub-decimeter tracking of earth satellites and few-centimeter determination of ground-fixed baselines. Key requirements of the two applications include the use of dual-frequency carrier phase data, multiple ground receivers to serve as reference points, simultaneous solution for use position and GPS orbits, and calibration of atmospheric delays using water vapor radiometers. Sub-decimeter tracking will be first demonstrated on the TOPEX oceanographic satellite to be launched in 1991. A GPS flight receiver together with at least six ground receivers will acquire delta range data from the GPS carriers for non-real-time analysis. Altitude accuracies of 5 to 10 cm are expected. For baseline measurements, efforts will be made to obtain precise differential pseudorange by resolving the cycle ambiguity in differential carrier phase. This could lead to accuracies of 2 or 3 cm over a few thousand kilometers. To achieve this, a high-performance receiver is being developed, along with improved calibration and data processing techniques. Demonstrations may begin in 1986.

Yunck, T. P.↗

Digitally Calibrated TR Modules Enabling Real-Time Beamforming SweepSAR Architectures

SweepSAR, a novel radar architecture that depends on a DBF (digital beamforming) array, requires calibration accuracies that are order(s) of magnitude greater than is possible with traditional techniques, such as a priori characterization of TR (transmit/receive) modules in thermal vacuum chambers, or simple loop-back of the calibration signal. The advantages of a SweepSAR architecture are so great that it is worth applying significant resources to calibration efforts. Due to the nature of the DBF, each channel contains a digitizer and very powerful digital processor. Each channel can independently digitize (with the digitizer) and analyze (with the processor) its channel's unique calibration signal, and extract the relevant calibration parameters, namely channel gain and channel phase delay commonly referred to as the gain (or amplitude) and phase of the channel. Using the processor, each channel's gain and phase can theoretically be estimated with arbitrary precision through averaging a sufficiently large number of samples. Systematic errors and the changing gain and phase of the channels, typically due to temperature drifts, limits how long the averaging can occur, which limits the precision of the calibration estimate. However, results indicate that calibration knowledge of both the transmit and receive chains of each TR module can be improved by one or two orders of magnitude. Due to the digital nature of the receiver data, the channel's gain and phase may be corrected by a similar amount, while the transmit chain can only be corrected in a traditional manner. To implement Sweep SAR, the order of magnitude improvement in the knowledge of the channel's gain and phase is needed, and the control of the receiver to a similar level is required. Inherent to the DBF array is the individual digitization of each of the array's receiver channels. Current systems typically combine all of the analog signals in the array into one or two analog channels, which are then digitized and processed. All signal conditioning performed prior to digitization is done using analog hardware (which is less precise than digital signal conditioning and dependent on temperature). The DBF digitizes every signal prior to combining, and can therefore analyze and correct received signals, as well as analyze signals that are being transmitted through analog hardware (by sampling a copy and digitizing). Each channel of a DBF also has a powerful processor. With this combination, one is able to digitize, analyze, and correct each channel prior to its being combined. A unique factor is the ability to digitize and analyze (in real time) each of the array's channels independently, allowing one to achieve unprecedented knowledge of each channel's performance (gain and phase), and since the combining is done digitally, each receive channel can be corrected prior to combining. This enables an unprecedented level of accuracy and control through onboard processing. SweepSAR promises significant increases in instrument capability for solid earth and biomass remote sensing, while reducing mission mass and cost. This new instrument concept requires new methods for calibrating the multiple channels, which must be combined onboard, in real time. New methods are being developed for digitally calibrating digital beam-forming arrays to reduce development time, risk, and cost of precision calibrated TR modules for array architectures by accurately tracking modules' characteristics through closed-loop digital calibration, thus tracking systematic changes regardless of temperature.-

Hoffman, James P.↗

Gaussian mixture model clustering algorithms for the analysis of high-precision mass measurements

The development of the phase-imaging ion-cyclotron resonance (PI-ICR) technique for use in Penning trap mass spectrometry (PTMS) increased the speed and precision with which PTMS experiments can be carried out. In PI-ICR, data sets of the locations of individual ion hits on a detector are created showing how ions cluster together into spots according to their cyclotron frequency. Ideal data sets would consist of a single, 2D-spherical spot with no other noise, but in practice data sets typically contain multiple spots, non-spherical spots, or significant noise, all of which can make determining the locations of spot centers non-trivial. A method for assigning groups of ions to their respective spots and determining the spot centers is therefore essential for further improving precision and confidence in PI-ICR experiments. Here, we present the class of Gaussian mixture model (GMM) clustering algorithms as an optimal solution. We show that on simulated PI-ICR data, several types of GMM clustering algorithms perform better than other clustering algorithms over a variety of typical scenarios encountered in PI-ICR. The mass spectra of 163Gd, 163 mGd, 162 Tb, and 162 mTb measured using PI-ICR at the Canadian Penning trap mass spectrometer were checked using GMMs, producing results that were in close agreement with the previously published values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parameter Analysis of Lunar Surface Navigation Utilizing Dilution-of-Precision Methodology With Lunar Orbiters

With the NASA Vision for Space Exploration focusing on the return of astronauts to the Moon and eventually to Mars, architectures for new navigation concepts must be derived and analyzed. One such concept, developed by the Space Communications Architecture Working Group (SCAWG), is to place a constellation of satellites around the Moon. Previously completed analyses examined the performance of multiple satellite constellations and recommended a constellation oriented as a Walker polar 6/2/1 with a semimajor axis (SMA) of 9250 km. One requirement of the constellations that were examined was that they have continuous access to any location on the lunar surface. In this report, the polar 6/2/1 and polar 8/2/1, with equal SMAs, are examined in greater detail. The dilution-of-precision (DoP) methodology is utilized to examine the effects of longitude surface points, latitude surface points, elevation requirements, and modified failure modes for these two constellations with regard to system availability. Longitude study results show that points along a meridian closely approximate the results of a global set of data points. Latitude study results show that previous assumptions with regard to latitude spacing are adequate to simulate global system availability. Elevation study results show that global system availability curves follow a reverse sigmoid function. Modified failure mode study results show that the benefits of reorienting a failure mode constellation depend on the type of navigation system and the length of the integration period being used.

Welch, Bryan W.↗

Optical Fiber Array Assemblies for Space Flight on the Lunar Reconnaissance Orbiter

Custom fiber optic bundle array assemblies developed by the Photonics Group at NASA Goddard Space Flight Center were an enabling technology for both the Lunar Orbiter Laser Altimeter (LOLA) and the Laser Ranging (LR) Investigation on the Lunar Reconnaissance Orbiter (LRO) currently in operation. The unique assembly array designs provided considerable decrease in size and weight and met stringent system level requirements. This is the first time optical fiber array bundle assemblies were used in a high performance space flight application. This innovation was achieved using customized Diamond Switzerland AVIM optical connectors. For LOLA, a five fiber array was developed for the receiver telescope to maintain precise alignment for each of the 200/220 micron optical fibers collecting 1,064 nm wavelength light being reflected back from the moon. The array splits to five separate detectors replacing the need for multiple telescopes. An image illustration of the LOLA instrument can be found at the top of the figure. For the laser ranging, a seven-optical-fiber array of 400/440 micron fibers was developed to transmit light from behind the LR receiver telescope located on the end of the high gain antenna system (HGAS). The bundle was routed across two moving gimbals, down the HGAS boom arm, over a deployable mandrel and across the spacecraft to a detector on the LOLA instrument. The routing of the optical fiber bundle and its end locations is identified in the figure. The Laser Ranging array and bundle is currently accepting light at a wavelength of 532 nm sent to the moon from laser stations at Greenbelt MD and other stations around the world to gather precision ranging information from the Earth to the LRO spacecraft. The LR bundle assembly is capable of withstanding temperatures down to -55 C at the connectors, and 20,000 mechanical gimbal cycles at temperatures as cold as -20 C along the length of the seven-fiber bundle (that is packaged into the gimbals). The total bundle assembly is 10 meters long with two interconnections requiring precise clocking of the seven-fiber array pattern.

Ott, Jelanie↗

One-Nanometer-Thick Pt 3 Ni Bimetallic Alloy Nanowires Advanced Oxygen Reduction Reaction: Integrating Multiple Advantages into One Catalyst

Developing highly active as well as durable oxygen reduction reaction (ORR) electrocatalysts are still imperative for clean and efficient energy conversion device, such as fuel cells and metal-air battery. For this purpose and maximize the utilization of noble Pt, we present here a facile, yet scalable strategy for the high-precise synthesis of 1-nm-thick Pt 3 Ni bimetallic alloy nanowires (Pt 3 Ni BANWs). The seed-mediated growth mechanism of Pt 3 Ni BANWs was identified subsequently. As expected, the Pt 3 Ni BANWs delivered enhanced mass activity (0.546 A mgPt –1 , exceeding the 2020 target of DOE) in comparison to Pt nanowires assembly (Pt NWA, 0.098 A mgPt –1 ) and Pt/C (Pt, 0.135 A mgPt –1 ), because of the rational integration of multiple compositional and structural advantages. Moreover, the Pt 3 Ni BANWs displayed enhanced durability (37% MA retention) than Pt NWA and Pt after 50 000 potential cycles. All these results indicate that the ultrathin Pt 3 Ni BANWs are potential candidates for catalyzing ORR with acceptable activity and durability. In conclusion, the present work could not only provide a facile strategy but also a general guidance for the design of superb performance Pt-based nanowire catalysts for ORR.

25 ENERGY STORAGE↗

An effective field theory for muon conversion and muon decay-in-orbit

Muon conversion is one of the best probes of charged lepton flavor violation. The experimental limit is soon expected to improve by four orders of magnitude, thus calling for precise predictions of the shape of the signal spectrum. Equally important are precise predictions for muon decay-in-orbit, the main background for muon conversion. While the calculation of electromagnetic corrections to the two processes above the nuclear scale does not involve significant challenges, it becomes substantially more complex below that scale due to multiple scales, bound-state effects and experimental setup. Here, we present a systematic framework that addresses these challenges by resorting to a series of effective field theories. Combining Heavy Quark Effective Theory (HQET), Non-Relativistic QED (NRQED), potential NRQED, Soft-Collinear Effective Theory I and II, and boosted HQET, we derive a factorization theorem and present the renormalization group equations. Our framework allows for the proper calculation of precise predictions for the rates of the two processes, with crucial implications for the upcoming muon conversion searches. We also provide the most accurate prediction of the signal shape for those searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Estimating the Effective System Dead Time Parameter for Correlated Neutron Counting

We present that neutron time correlation analysis is one of the main technical nuclear safeguards techniques used to verify declarations of, or to independently assay, special nuclear materials. Quantitative information is generally extracted from the neutron-event pulse train, collected from moderated assemblies of 3 He proportional counters, in the form of correlated count rates that are derived from event-triggered coincidence gates. These count rates, most commonly referred to as singles, doubles and triples rates etc., when extracted using shift-register autocorrelation logic, are related to the reduced factorial moments of the time correlated clusters of neutrons emerging from the measurement items. Correcting these various rates for dead time losses has received considerable attention recently. The dead time losses for the higher moments in particular, and especially for large mass (high rate and highly multiplying) items, can be significant. Consequently, even in thoughtfully designed systems, accurate dead time treatments are needed if biased mass determinations are to be avoided. In support of this effort, in this paper we discuss a new approach to experimentally estimate the effective system dead time of neutron coincidence counting systems. It involves counting a random neutron source (e.g. AmLi is a good approximation to a source without correlated emission) and relating the second and higher moments of the neutron number distribution recorded in random triggered interrogation coincidence gates to the effective value of dead time parameter. We develop the theoretical basis of the method and apply it to the Oak Ridge Large Volume Active Well Coincidence Counter using sealed AmLi radionuclide neutron sources and standard multiplicity shift register electronics. The method is simple to apply compared to the predominant present approach which involves using a set of 252 Cf sources of wide emission rate, it gives excellent precision in a conveniently short time, and it yields consistent results as a function of the order of the moment used to extract the dead time parameter. In addition, this latter observation is reassuring in that it suggests the assumptions underpinning the theoretical analysis are fit for practical application purposes. However, we found that the effective dead time parameter obtained is not constant, as might be expected for a parameter that in the dead time model is characteristic of the detector system, but rather, varies systematically with gate width.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Following the dynamics of matter with femtosecond precision using the X-ray streaking method

X-ray Free Electron Lasers (FELs) can produce extremely intense and very short pulses, down to below 10 femtoseconds (fs). Among the key applications are ultrafast time-resolved studies of dynamics of matter by observing responses to fast excitation pulses in a pump-probe manner. Detectors with sufficient time resolution for observing these processes are not available. Therefore, such experiments typically measure a sample's full dynamics by repeating multiple pump-probe cycles at different delay times. This conventional method assumes that the sample returns to an identical or very similar state after each cycle. Here we describe a novel approach that can provide a time trace of responses following a single excitation pulse, jitter-free, with fs timing precision. We demonstrate, in an X-ray diffraction experiment, how it can be applied to the investigation of ultrafast irreversible processes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗