Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “maximize”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Entanglement types for two-qubit states with real amplitudes

We study the set of two-qubit pure states with real amplitudes and their geometrical representation in the three-dimensional sphere. In this representation, we show that the maximally entangled states—those locally equivalent to the Bell states—form two disjoint circles perpendicular to each other. We also show that taking the natural Riemannian metric on the sphere, the set of states connected by local gates are equidistant to this pair of circles. Moreover, the unentangled or so-called product states are π/4 units away to the maximally entangled states. This is, the unentangled states are the farthest away to the maximally entangled states. In this way, if we define two states to be equivalent if they are connected by local gates, we have that there are as many equivalent classes as points in the interval [0,π/4] with the point 0 corresponding to the maximally entangled states. The point π/4 corresponds to the unentangled states which geometrically are described by a torus. Finally, for every 0<d<π/4 the point d corresponds to a disjoint pair of torus. Finally, we also show how this geometrical interpretation allows to clearly see that any pair of two-qubit states with real amplitudes can be connected with a circuit that only has single-qubit gates and one controlled-Z gate.

97 MATHEMATICS AND COMPUTING↗

Processing and Thermoelectric Properties of TiNiSn Materials: A Review

The half-Heusler alloy TiNiSn is a promising material for high-temperature thermoelectric applications due to its good thermal stability and semiconductor-like electrical properties. Numerous synthesis techniques have been utilized to make TiNiSn, but a comparative study on its thermoelectric properties with respect to processing parameters has not been reported. Based on published experimental data, primary melting methods, such as arc melting or induction levitation melting, do not have a noticeable effect on the final thermoelectric properties, although choice of densification technique and annealing parameters correlate with each thermoelectric property. Thermal conductivity (2.47-6.08 W/m K), governed by lattice scattering effects, was maximized with high density from the spark plasma sintering (SPS) technique as well with low inclusions of metallic impurities and interstitial Ni defects from low-temperature, non-densified processes. Electrical resistivity (4.75-30 µΩ m), inversely related to thermal conductivity, is minimized when density is maximized and chemical defects are favorable from using SPS. All reported TiNiSn alloys contain intermetallic impurities, imparting a global trend of lowered electrical resistivity. Seebeck coefficient (− 273.20 to − 50.71 µV/K), proportional to electrical resistivity, is maximized when charge carrier concentration is minimized by eliminating phase impurities and Ni defects. Porosity has been observed to scatter low-energy electrons, which can increase Seebeck coefficient and electrical resistivity, although no statistical significance is found. An ideal TiNiSn alloy should have intermediate values of all interconnected thermoelectric properties to maximize ZT. Future research work should strive to include quantitative phase analysis to better characterize the contributions of Ni defects and impurity phases toward thermoelectric properties.

36 MATERIALS SCIENCE↗

Effect of Bladder Distension on Dose Distribution of Intracavitary Brachytherapy for Cervical Cancer: Three-Dimensional Computed Tomography Plan Evaluation

Purpose: To quantify the effect of bladder volume on the dose distribution during intracavitary brachytherapy for cervical cancer. Methods and Patients: The study was performed on 10 women with cervical cancer who underwent brachytherapy treatment. After insertion of the brachytherapy applicator, the patients were transferred to the computed tomography unit. Two sets of computed tomography slices were taken, including the pelvis, one with an empty bladder and one after the bladder was filled with saline. The target and critical organs were delineated by the radiation oncologist and checked by the expert radiologist. The radiotherapy plan was run on the Plato planning system, version 14.1, to determine the dose distributions, dose-volume histograms, and maximal dose points. The doses and organ volumes were compared with the Wilcoxon signed ranks test on a personal computer using the Statistical Package for Social Sciences, version 11.0, statistical program. Results: No significant difference regarding the dose distribution and target volumes between an empty or full bladder was observed. Bladder fullness significantly affected the dose to the small intestine, rectum, and bladder. The median of maximal doses to the small intestine was significantly greater with an empty bladder (493 vs. 284 cGy). Although dosimetry revealed lower doses for larger volumes of bladder, the median maximal dose to the bladder was significantly greater with a full bladder (993 vs. 925 cGy). The rectal doses were also affected by bladder distension. The median maximal dose was significantly lower in the distended bladder (481vs. 628 cGy). Conclusions: Bladder fullness changed the dose distributions to the bladder, rectum, and small intestine. The clinical importance of these changes is not known and an increase in the use of three-dimensional brachytherapy planning will highlight the answer to this question.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tolerance of Pyramidal Tract to Gamma Knife Radiosurgery Based on Diffusion-Tensor Tractography

Purpose: To minimize the morbidity of radiosurgery for critically located lesions, we integrated diffusion-tensor tractography into treatment planning for gamma-knife radiosurgery. We calculated the refined tolerance of the pyramidal tract (PT) after prospective application of the technique to additional patients. Methods and Materials: The relationship between the dosimetry during treatment planning and the development of subsequent motor complications was investigated in 24 patients, 9 studied retrospectively and 15 studied prospectively. The maximal dose to the PT and the volumes of the PT that received {>=}20 Gy (20-Gy volume) and {>=}25 Gy (25-Gy volume) were calculated. Univariate logistic regression analyses were used to produce dose-response curves. Differences in the tolerable dose according to the PT location were calculated. Results: Univariate logistic regression analysis of the motor complications revealed a significant independent correlation with the maximal dose to the PT and the 20- and 25-Gy volumes. The maximal dose to the PT with a 5% risk of motor complications was 23 Gy compared with 15 Gy in our previous report. The risk of motor complications was significantly greater in the internal capsule than in the corona radiata for the 20- and 25-Gy volumes in generalized Wilcoxon tests (p = 0.031), although no significant difference was observed for the maximal dose. Conclusion: The tolerable dose of the PT was greater than that previously reported. The internal capsule was more sensitive to high-dose irradiation over a wide area of the PT, probably owing to the dense concentration of motor fibers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Clinical Trial of Bladder Filling and Three-Dimensional Dosimetry in High-Dose-Rate Vaginal Cuff Brachytherapy

Purpose: To investigate the effect of bladder filling on dosimetry and to determine the best bladder dosimetric parameter for vaginal cuff brachytherapy. Methods and Materials: In this prospective clinical trial, a total of 20 women underwent vaginal cylinder high-dose-rate brachytherapy. The bladder was full for Fraction 2 and empty for Fraction 3. Dose-volume histogram and dose-surface histogram values were generated for the bladder, rectum, and urethra. The midline maximal bladder point (MBP) and the midline maximal rectal point were recorded. Paired t tests, Pearson correlations, and regression analyses were performed. Results: The volume and surface area of the irradiated bladder were significantly smaller when the bladder was empty than when full. Of the several dose-volume histogram and dose-surface histogram parameters evaluated, the bladder maximal dose received by 2 cm{sup 3} of tissue, volume of bladder receiving {>=}50% of the dose, volume of bladder receiving {>=}70% of the dose, and surface area of bladder receiving {>=}50% of the dose significantly predicted for the difference between the empty vs. full filling state. The volume of bladder receiving {>=}70% of the dose and the maximal dose received by 2 cm{sup 3} of tissue correlated significantly with the MBP. Bladder filling did not alter the volume or surface area of the rectum irradiated. However, an empty bladder did result in the nearest point of bowel being significantly closer to the vaginal cylinder than when the bladder was full. Conclusions: Patients undergoing vaginal cuff brachytherapy treated with an empty bladder have a lower bladder dose than those treated with a full bladder. The MBP correlated well with the volumetric assessments of bladder dose and provided a noninvasive method for reporting the MBP dose using three-dimensional imaging. The MBP can therefore be used as a surrogate for complex dosimetry in the clinic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating and Reporting Dysphagia in Trials of Chemoirradiation for Head-and-Neck Cancer

Purpose: Reporting long-term toxicities in trials of chemoirradiation (CRT) of head-and-neck cancer (HNC) has mostly been limited to observer-rated maximal Grades {>=}3. We evaluated this reporting approach for dysphagia by assessing patient-reported dysphagia (PRD) and objective swallowing dysfunction through videofluoroscopy (VF) in patients with various grades of maximal observer-reported dysphagia (ORD). Methods and Materials: A total of 62 HNC patients completed quality-of-life questionnaires periodically through 12 months post-CRT. Five PRD items were selected: three dysphagia-specific questions, an Eating-Domain, and 'Overall Bother.' They underwent VF at 3 and 12 months, and ORD (Common Terminology Criteria for Adverse Events) scoring every 2 months. We classified patients into four groups (0-3) according to maximal ORD scores documented 3-12 months post-CRT, and assessed PRD and VF summary scores in each group. Results: Differences in ORD scores among the groups were considerable throughout the observation period. In contrast, PRD scores were similar between Groups 2 and 3, and variable in Group 1. VF scores were worse in Group 3 compared with 2 at 3 months but similar at 12 months. In Group 1, PRD and VF scores from 3 through 12 months were close to Groups 2 and 3 if ORD score 1 persisted, but were similar to Group 0 in patients whose ORD scores improved by 12 months. Conclusions: Patients with lower maximal ORD grades, especially if persistent, had similar rates of PRD and objective dysphagia as patients with highest grades. Lower ORD grades should therefore be reported. These findings may have implications for reporting additional toxicities besides dysphagia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Individualized Dose Prescription for Hypofractionation in Advanced Non-Small-Cell Lung Cancer Radiotherapy: An in silico Trial

Purpose: Local tumor control and outcome remain poor in patients with advanced non-small-cell lung cancer (NSCLC) treated by external beam radiotherapy. We investigated the therapeutic gain of individualized dose prescription with dose escalation based on normal tissue dose constraints for various hypofractionation schemes delivered with intensity-modulated radiation therapy. Methods and Materials: For 38 Stage III NSCLC patients, the dose level of an existing curative treatment plan with standard fractionation (66 Gy) was rescaled based on dose constraints for the lung, spinal cord, esophagus, brachial plexus, and heart. The effect on tumor total dose (TTD) and biologic tumor effective dose in 2-Gy fractions (TED) corrected for overall treatment time (OTT) was compared for isotoxic and maximally tolerable schemes given in 15, 20, and 33 fractions. Rescaling was accomplished by altering the dose per fraction and/or the number of fractions while keeping the relative dose distribution of the original treatment plan. Results: For 30 of the 38 patients, dose escalation by individualized hypofractionation yielded therapeutic gain. For the maximally tolerable dose scheme in 33 fractions (MTD{sub 33}), individualized dose escalation resulted in a 2.5-21% gain in TTD. In the isotoxic schemes, the number of fractions could be reduced with a marginal increase in TED. For the maximally tolerable dose schemes, the TED could be escalated up to 36.6%, and for all patients beyond the level of the isotoxic and the MTD{sub 33} schemes (range, 3.3-36.6%). Reduction of the OTT contributed to the therapeutic gain of the shortened schemes. For the maximally tolerable schemes, the maximum esophageal dose was the dominant dose-limiting constraint in most patients. Conclusions: This modeling study showed that individualized dose prescription for hypofractionation in NSCLC radiotherapy, based on scaling of existing treatment plans up to normal tissue dose constraints, enables dose escalation with therapeutic gain in 79% of the cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Dose to the Bladder Trigone on Long-Term Urinary Function After High-Dose Intensity Modulated Radiation Therapy for Localized Prostate Cancer

Purpose: To determine the potential association between genitourinary (GU) toxicity and planning dose–volume parameters for GU pelvic structures after high-dose intensity modulated radiation therapy in localized prostate cancer patients. Methods and Materials: A total of 268 patients who underwent intensity modulated radiation therapy to a prescribed dose of 86.4 Gy in 48 fractions during June 2004-December 2008 were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Dose–volume histograms of the whole bladder, bladder wall, urethra, and bladder trigone were analyzed. The primary endpoint for GU toxicity was an IPSS sum increase ≥10 points over baseline. Univariate and multivariate analyses were done by the Kaplan-Meier method and Cox proportional hazard models, respectively. Results: Median follow-up was 5 years (range, 3-7.7 years). Thirty-nine patients experienced an IPSS sum increase ≥10 during follow-up; 84% remained event free at 5 years. After univariate analysis, lower baseline IPSS sum (P=.006), the V90 of the trigone (P=.006), and the maximal dose to the trigone (P=.003) were significantly associated with an IPSS sum increase ≥10. After multivariate analysis, lower baseline IPSS sum (P=.009) and increased maximal dose to the trigone (P=.005) remained significantly associated. Seventy-two patients had both a lower baseline IPSS sum and a higher maximal dose to the trigone and were defined as high risk, and 68 patients had both a higher baseline IPSS sum and a lower maximal dose to the trigone and were defined as low risk for development of an IPSS sum increase ≥10. Twenty-one of 72 high-risk patients (29%) and 5 of 68 low-risk patients (7%) experienced an IPSS sum increase ≥10 (P=.001; odds ratio 5.19). Conclusions: The application of hot spots to the bladder trigone was significantly associated with relevant changes in IPSS during follow-up. Reduction of radiation dose to the lower bladder and specifically the bladder trigone seems to be associated with a reduction in late GU toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Approximate Bayesian Model Inversion for PDEs with Heterogeneous and State-Dependent Coefficients

We present two approximate Bayesian inference methods for parameter estimation in partial differential equation (PDE) models with space-dependent and state-dependent parameters. We demonstrate that these methods provide accurate and cost-effective alternatives to Markov Chain Monte Carlo simulation. We assume a parameterized Gaussian prior on the unknown functions, and approximate the posterior density by a parameterized multivariate Gaussian density. The parameters of the prior and posterior are estimated from sparse observations of the PDE model's states and the unknown functions themselves by maximizing the evidence lower bound (ELBO), a lower bound on the log marginal likelihood of the observations. The first method, Laplace-EM, employs the expectation maximization algorithm to maximize the ELBO, with a Laplace approximation of the posterior on the E-step, and minimization of a Kullback-Leibler divergence on the M-step. The second method, DSVI-EB, employs the doubly stochastic variational inference (DSVI) algorithm, in which the ELBO is maximized via gradient-based stochastic optimization, with nosiy gradients computed via simple Monte Carlo sampling and Gaussian backpropagation. We apply these methods to identifying diffusion coefficients in linear and nonlinear diffusion equations, and we find that both methods provide accurate estimates of posterior densities and the hyperparameters of Gaussian priors. While the Laplace-EM method is more accurate, it requires computing Hessians of the physics model. The DSVI-EB method is found to be less accurate but only requires gradients of the physics model.

approximate Bayesian inference, model inversion, v↗

Volumetric tumor burden and its effect on brachial plexus dosimetry in head and neck intensity-modulated radiotherapy

To determine the effect of gross tumor volume of the primary (GTV-P) and nodal (GTV-N) disease on planned radiation dose to the brachial plexus (BP) in head and neck intensity-modulated radiotherapy (IMRT). Overall, 75 patients underwent definitive IMRT to a median total dose of 69.96 Gy in 33 fractions. The right BP and left BP were prospectively contoured as separate organs at risk. The GTV was related to BP dose using the unpaired t-test. Receiver operating characteristics curves were constructed to determine optimized volumetric thresholds of GTV-P and GTV-N corresponding to a maximum BP dose cutoff of > 66 Gy. Multivariate analyses were performed to account for factors associated with a higher maximal BP dose. A higher maximum BP dose (> 66 vs ≤ 66 Gy) correlated with a greater mean GTV-P (79.5 vs 30.8 cc; p = 0.001) and ipsilateral GTV-N (60.6 vs 19.8 cc; p = 0.014). When dichotomized by the optimized nodal volume, patients with an ipsilateral GTV-N ≥ 4.9 vs < 4.9 cc had a significant difference in maximum BP dose (64.2 vs 59.4 Gy; p = 0.001). Multivariate analysis confirmed that an ipsilateral GTV-N ≥ 4.9 cc was an independent predictor for the BP to receive a maximal dose of > 66 Gy when adjusted individually for BP volume, GTV-P, the use of a low anterior neck field technique, total planned radiation dose, and tumor category. Although both the primary and the nodal tumor volumes affected the BP maximal dose, the ipsilateral nodal tumor volume (GTV-N ≥ 4.9 cc) was an independent predictor for high maximal BP dose constraints in head and neck IMRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Base norms and discrimination of generalized quantum channels

We introduce and study norms in the space of hermitian matrices, obtained from base norms in positively generated subspaces. These norms are closely related to discrimination of so-called generalized quantum channels, including quantum states, channels, and networks. We further introduce generalized quantum decision problems and show that the maximal average payoffs of decision procedures are again given by these norms. We also study optimality of decision procedures, in particular, we obtain a necessary and sufficient condition under which an optimal 1-tester for discrimination of quantum channels exists, such that the input state is maximally entangled.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

General method for simultaneous optimization of light trapping and carrier collection in an ultra-thin film organic photovoltaic cell

We describe a general method for maximizing the short-circuit current in thin planar organic photovoltaic (OPV) heterojunction cells by simultaneous optimization of light absorption and carrier collection. Based on the experimentally obtained complex refractive indices of the OPV materials and the thickness-dependence of the internal quantum efficiency of the OPV active layer, we analyze the potential benefits of light trapping strategies for maximizing the overall power conversion efficiency of the cell. This approach provides a general strategy for optimizing the power conversion efficiency of a wide range of OPV structures. In particular, as an experimental trial system, the approach is applied here to a ultra-thin film solar cell with a SubPc/C{sub 60} photovoltaic structure. Using a patterned indium tin oxide (ITO) top contact, the numerically optimized designs achieve short-circuit currents of 0.790 and 0.980 mA/cm{sup 2} for 30 nm and 45 nm SubPc/C{sub 60} heterojunction layer thicknesses, respectively. These values correspond to a power conversion efficiency enhancement of 78% for the 30 nm thick cell, but only of 32% for a 45 nm thick cell, for which the overall photocurrent is actually higher. Applied to other material systems, the general optimization method can elucidate if light trapping strategies can improve a given cell architecture.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Generalized model screening potentials for Fermi-Dirac plasmas

In this paper, some properties of relativistically degenerate quantum plasmas, such as static ion screening, structure factor, and Thomson scattering cross-section, are studied in the framework of linearized quantum hydrodynamic theory with the newly proposed kinetic γ-correction to Bohm term in low frequency limit. It is found that the correction has a significant effect on the properties of quantum plasmas in all density regimes, ranging from solid-density up to that of white dwarf stars. It is also found that Shukla-Eliasson attractive force exists up to a few times the density of metals, and the ionic correlations are seemingly apparent in the radial distribution function signature. Simplified statically screened attractive and repulsive potentials are presented for zero-temperature Fermi-Dirac plasmas, valid for a wide range of quantum plasma number-density and atomic number values. Moreover, it is observed that crystallization of white dwarfs beyond a critical core number-density persists with this new kinetic correction, but it is shifted to a much higher number-density value of n{sub 0} ≃ 1.94 × 10{sup 37} cm{sup −3} (1.77 × 10{sup 10} gr cm{sup −3}), which is nearly four orders of magnitude less than the nuclear density. It is found that the maximal Thomson scattering with the γ-corrected structure factor is a remarkable property of white dwarf stars. However, with the new γ-correction, the maximal scattering shifts to the spectrum region between hard X-ray and low-energy gamma-rays. White dwarfs composed of higher atomic-number ions are observed to maximally Thomson-scatter at slightly higher wavelengths, i.e., they maximally scatter slightly low-energy photons in the presence of correction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Note: A versatile mass spectrometer chamber for molecular beam and temperature programmed desorption experiments

A dual purpose mass spectrometer chamber capable of performing molecular beam scattering (MBS) and temperature programmed desorption (TPD) is detailed. Two simple features of this design allow it to perform these techniques. First, the diameter of entrance aperture to the mass spectrometer can be varied to maximize signal for TPD or to maximize angular resolution for MBS. Second, the mass spectrometer chamber can be radially translated so that it can be positioned close to the sample to maximize signal or far from the sample to maximize angular resolution. The performance of this system is described and compares well with systems designed for only one of these techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reciprocal insulation analysis of Hi-C data shows that TADs represent a functionally but not structurally privileged scale in the hierarchical folding of chromosomes

Understanding how regulatory sequences interact in the context of chromosomal architecture is a central challenge in biology. Chromosome conformation capture revealed that mammalian chromosomes possess a rich hierarchy of structural layers, from multi-megabase compartments to sub-megabase topologically associating domains (TADs) and sub-TAD contact domains. TADs appear to act as regulatory microenvironments by constraining and segregating regulatory interactions across discrete chromosomal regions. However, it is unclear whether other (or all) folding layers share similar properties, or rather TADs constitute a privileged folding scale with maximal impact on the organization of regulatory interactions. Here, we present a novel algorithm named CaTCH that identifies hierarchical trees of chromosomal domains in Hi-C maps, stratified through their reciprocal physical insulation, which is a single and biologically relevant parameter. By applying CaTCH to published Hi-C data sets, we show that previously reported folding layers appear at different insulation levels. We demonstrate that although no structurally privileged folding level exists, TADs emerge as a functionally privileged scale defined by maximal boundary enrichment in CTCF and maximal cell-type conservation. By measuring transcriptional output in embryonic stem cells and neural precursor cells, we show that the likelihood that genes in a domain are coregulated during differentiation is also maximized at the scale of TADs. Finally, we observe that regulatory sequences occur at genomic locations corresponding to optimized mutual interactions at the same scale. Our analysis suggests that the architectural functionality of TADs arises from the interplay between their ability to partition interactions and the specific genomic position of regulatory sequences.

Biochemistry & Molecular Biology↗

Spin-spin entanglement in diffractive heavy-quark production

We calculate the spin density matrix of a heavy-quark-antiquark pair ($b\bar{⁢b}$, $c\bar{⁢c}$ or $s\bar{⁢s}$) diffractively produced in deep inelastic scattering and ultraperipheral collisions. We show that the Pomeron exchange leaves characteristic imprints on the entanglement pattern between the quark and the antiquark. For the longitudinally polarized virtual photon, the pair always exhibits maximal entanglement and maximal violation of the Bell-Clauser-Horne-Shimony-Holt inequality. For the transversely polarized photon, the pair is always entangled and Bell violating, reaching maximal entanglement and maximal violation simultaneously when the transverse momentum approximately equals the quark mass.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Local cloning of entangled states

We investigate the conditions under which a set S of pure bipartite quantum states on a DxD system can be locally cloned deterministically by separable operations, when at least one of the states is full Schmidt rank. We allow for the possibility of cloning using a resource state that is less than maximally entangled. Our results include that: (i) all states in S must be full Schmidt rank and equally entangled under the G-concurrence measure, and (ii) the set S can be extended to a larger clonable set generated by a finite group G of order |G|=N, the number of states in the larger set. It is then shown that any local cloning apparatus is capable of cloning a number of states that divides D exactly. We provide a complete solution for two central problems in local cloning, giving necessary and sufficient conditions for (i) when a set of maximally entangled states can be locally cloned, valid for all D; and (ii) local cloning of entangled qubit states with nonvanishing entanglement. In both of these cases, we show that a maximally entangled resource is necessary and sufficient, and the states must be related to each other by local unitary 'shift' operations. These shifts are determined by the group structure, so need not be simple cyclic permutations. Assuming this shifted form and partially entangled states, then in D=3 we show that a maximally entangled resource is again necessary and sufficient, while for higher-dimensional systems, we find that the resource state must be strictly more entangled than the states in S. All of our necessary conditions for separable operations are also necessary conditions for local operations and classical communication (LOCC), since the latter is a proper subset of the former. In fact, all our results hold for LOCC, as our sufficient conditions are demonstrated for LOCC, directly.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correlation between complex spin textures and the magnetocaloric and Hall effects in Eu⁢(Ga 1−𝑥 ⁢Al 𝑥 ) 4 (𝑥=0.9, 1)

Determining the electronic phase diagram of a quantum material as a function of temperature (𝑇) and applied magnetic field (𝐻) forms the basis for understanding the microscopic origin of transport properties, such as the anomalous Hall effect (AHE) and topological Hall effect (THE). For many magnetic quantum materials, including Eu⁢Al 4 , a THE arises from a topologically protected magnetic skyrmion lattice with a nonzero scalar spin chirality. We identified a square skyrmion lattice (sSkL) peak in Eu⁢(Ga 1−𝑥 ⁢Al 𝑥 ) 4 (𝑥=0.9) identical to the peak previously observed in Eu⁢Al 4 by performing neutron-scattering measurements throughout the phase diagram. Here, comparing these neutron results with transport measurements, we found that in both compounds the maximal THE does not correspond to the sSkL area. Instead of the maximal THE, the maximal magnetocaloric-effect boundaries better identify the sSkL lattice phase observed by neutron-scattering measurements. The maximal THE therefore arises from interactions of itinerant electrons with frustrated spin fluctuations in a topologically trivial magnetic state.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗