Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “linear system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

On the Solvability of a Matrix Boundary-Value Problem

We found solvability conditions and a construction of the generalized Green operator for a linear matrix boundary-value problem; we present an operator that reduces a linear matrix equation to the conventional linear Noether boundary-value problem. To solve a linear matrix system, we use the operator that reduces a linear matrix equation to a linear algebraic equation with a rectangular matrix.

97 MATHEMATICS AND COMPUTING↗

Dynamic decay of a single vortex into vortex-antivortex pairs

A variety of metastable states, including vortices, antivortices, and their combinations, is typical for magnetically soft, thin films and patterned structures. The physics of individual spin vortices in patterned structures has been rather extensively explored. In contrast, there are few studies of the vortex–antivortex–vortex (v-av-v) system, in part because the configuration is rather challenging to obtain experimentally. We demonstrate herein how a recently proposed resonant-spin-ordering technique can be used to induce the dynamic decay of a single vortex into v-av states in elongated elements. The approach is based on first driving the system from the linear regime of constant vortex gyrations to the non-linear regime of vortex-core reversals at a fixed excitation frequency, and then subsequently reducing the excitation field back to the linear regime. This procedure stabilizes the system into a v-av-v state that is completely decoupled from the initialization excitation frequency. The newly acquired state is stable in remanence. The dynamic response of this system is expected to demonstrate a number of collective modes, depending on the combination of the vortex core polarities, and/or the excitation field direction, and, hence, is of interest for future studies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Expansion-driven Weibel instability in magnetohydrodynamics: Linear theory for static systems

The Weibel dispersion relation is obtained in the magnetohydrodynamic (MHD) approximation by including a tensor expression for temperature. MHD gives an upper cutoff wavenumber for Weibel growth identical to kinetic theory if the electron drift velocity is included in the evolution of the electron temperature. MHD overestimates growth rates compared to kinetic theory and gives maximum growth at larger wavenumbers, but it only leads to divergent results as temperature anisotropy tends to infinity. Thermal conduction in MHD lowers the growth rates and shifts maximum growth to smaller wavenumbers, but flux-limited or nonlocal thermal conduction is found to significantly limit these effects. The results are used as a first step in evaluating the potential of MHD to simulate expansion-driven Weibel instability, which occurs due to the temperature tensor only cooling in the direction of expansion. Finally, the small temperature anisotropy found in expansion-driven Weibel instability means that MHD could be an adequate model because growth rates are much less than the electron plasma frequency, and wavelengths are much greater than the Debye length.

Davies, J. R. [Univ. of Rochester, NY (United Stat↗

SU-E-T-219: Comprehensive Validation of the Electron Monte Carlo Dose Calculation Algorithm in RayStation Treatment Planning System for An Elekta Linear Accelerator with AgilityTM Treatment Head

Purpose: This study evaluated the performance of the electron Monte Carlo dose calculation algorithm in RayStation v4.0 for an Elekta machine with Agility™ treatment head. Methods: The machine has five electron energies (6–8 MeV) and five applicators (6×6 to 25×25 cm {sup 2}). The dose (cGy/MU at d{sub max}), depth dose and profiles were measured in water using an electron diode at 100 cm SSD for nine square fields ≥2×2 cm{sup 2} and four complex fields at normal incidence, and a 14×14 cm{sup 2} field at 15° and 30° incidence. The dose was also measured for three square fields ≥4×4 cm{sup 2} at 98, 105 and 110 cm SSD. Using selected energies, the EBT3 radiochromic film was used for dose measurements in slab-shaped inhomogeneous phantoms and a breast phantom with surface curvature. The measured and calculated doses were analyzed using a gamma criterion of 3%/3 mm. Results: The calculated and measured doses varied by <3% for 116 of the 120 points, and <5% for the 4×4 cm{sup 2} field at 110 cm SSD at 9–18 MeV. The gamma analysis comparing the 105 pairs of in-water isodoses passed by >98.1%. The planar doses measured from films placed at 0.5 cm below a lung/tissue layer (12 MeV) and 1.0 cm below a bone/air layer (15 MeV) showed excellent agreement with calculations, with gamma passing by 99.9% and 98.5%, respectively. At the breast-tissue interface, the gamma passing rate is >98.8% at 12–18 MeV. The film results directly validated the accuracy of MU calculation and spatial dose distribution in presence of tissue inhomogeneity and surface curvature - situations challenging for simpler pencil-beam algorithms. Conclusion: The electron Monte Carlo algorithm in RayStation v4.0 is fully validated for clinical use for the Elekta Agility™ machine. The comprehensive validation included small fields, complex fields, oblique beams, extended distance, tissue inhomogeneity and surface curvature.

60 APPLIED LIFE SCIENCES↗