Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lifetime”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Modification of surface oxide layers of titanium targets for increasing lifetime of neutron tubes

The peculiarities of interaction of hydrogen ions with a titanium target and its surface oxide layer were studied. Two ways of modification of the surface oxide layers of titanium targets for increasing the lifetime of neutron tubes were proposed: (1) deposition of an yttrium oxide barrier layer on the target surface; (2) implementation of neutron tube work regime in which the target is irradiated with ions with energies lower than 1000 eV between high-energy ion irradiation pulses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Lifetime Extension of the Gas Discharge Detectors with Plasma Etching of Silicon Deposits in 80%CF{sub 4} + 20%CO{sub 2}

A method of elimination of silicon compounds from the anode wire of an aged proportional counter is presented. The aging of a counter with a 70%Ar + 30%CO{sub 2} and a 60%Ar + 30%CO{sub 2} + 10%СF{sub 4} working mixture was stimulated by a {sup 90}Sr β source. To accelerate the process of aging, the gas mixture flow to the counter was supplied through a pipe with RTV coated wall. As a result, the amplitude of the signal decreased 70% already at accumulated charge of Q = 0.03 C/cm. The etching of the silicon compounds on the wire surface with an 80%CF{sub 4} + 20%CO{sub 2} gas mixture discharge led to full recovery of the operating characteristics of detector and an increase in the lifetime. A scanning electron microscopy and X-ray spectroscopy analysis of the recovered wire surface were performed. In accordance with the results, a good quality of wire cleaning from SiO{sub 2} compounds was obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lifetime of excitons localized in Si nanocrystals in amorphous silicon

The introduction of nanocrystals plays an important role in improving the stability of the amorphous silicon films and increasing the carrier mobility. Here we report results of the study on the photoluminescence and its dynamics in the films of amorphous hydrogenated silicon containing less than 10% of silicon nanocrystals. The comparing of the obtained experimental results with the calculated probability of the resonant tunneling of the excitons localized in silicon nanocrystals is presented. Thus, it has been estimated that the short lifetime of excitons localized in Si nanocrystal is controlled by the resonant tunneling to the nearest tail state of the amorphous matrix.

36 MATERIALS SCIENCE↗

Long-wavelength stimulated emission and carrier lifetimes in HgCdTe-based waveguide structures with quantum wells

The interband photoconductivity and photoluminescence in narrow-gap HgCdTe-based waveguide structures with quantum wells (QWs) (designed for long-wavelength stimulated emission under optical pumping) are investigated. The photoconductivity relaxation times in n-type structures reach several microseconds, due to which stimulated emission at a wavelength of 10.2 μm occurs at a low threshold pump intensity (~100 W/cm{sup 2}) at 20 K. In the p-type structures obtained by annealing (to increase the mercury vacancy concentration), even spontaneous emission from the QWs is not detected because of a dramatic decrease in the carrier lifetime with respect to Shockley–Read–Hall nonradiative recombination.

36 MATERIALS SCIENCE↗

Lifetime of excess electrons in Cu–Zn–Sn–Se powders

The method of time-resolved microwave photoconductivity at a frequency of 36 GHz in the range of temperatures of 200–300 K is used to study the kinetics of the annihilation of charge carriers in Cu–Zn–Sn–Se powders obtained by the solid-phase method of synthesis in cells. The lifetime of excess electrons at room temperature is found to be shorter than 5 ns. The activation energy for the process of recombination amounted to E{sub a} ~ 0.054 eV.

36 MATERIALS SCIENCE↗

Carrier Lifetime in Semiconductors with Band-Gap Widths Close to the Spin-Orbit Splitting Energies

Expressions for the Auger- and radiative-recombination rates are derived in terms of Kane’s model for materials with a band-gap width close to the spin-orbit splitting energy, which is the case for InAs, InAsSb solid solutions, etc. Our results are compared with simplified expressions for recombination rates, frequently used in publications. It is shown that the nonparabolicity of the electronic structure should be taken into account in calculations of the recombination rates. As an example, the temperature dependences of the charge-carrier lifetimes governed by radiative and non-radiative processes are calculated for InAsSb solid solutions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulation of Experiment on Measurement of Neutron Lifetime Using the Big Gravitational Trap of Ultracold Neutrons with the Absorber

At present, the experiment on measuring neutron lifetime using a big gravitational trap is being performed at Petersburg Nuclear Physics Institute. It is planned to achieve a measurement precision of 0.2 s, which is four times better than the best existing level of precision. The modified installation is simulated using the Monte Carlo method. It has been shown that the application of the absorber in the installation design increases the number of stored ultracold neutrons in the trap by a factor of approximately three and reduces the duration of the measurement cycle.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental Setup for Neutron Lifetime Measurements with a Large Gravitational Trap at Low Temperatures

Currently the most accurate measurements of neutron lifetime are being performed at the Petersburg Nuclear Physics Institute with ultracold neutrons (UCNs) stored in a gravitational trap. A modified setup with a large gravitational trap and cooling to 10–15 K is presented. The results of measurements of temperature dependence of UCN losses in collisions with walls, which were coated with a perfluorinated grease (Fomblin UT 18), at 300–77 K, are detailed. The probable heat inflow to the trap is estimated, and the feasibility of cooling to indicated temperatures in experiments with the modified setup is demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lifetimes of low-lying levels in 158 Gd

The low-lying structure of the well-deformed nucleus 158 Gd has been revisited to elucidate the nature of the low-lying states in 158 Gd. Earlier (p, t) studies identified numerous 0 + states below 4.3 MeV, prompting questions about whether these states correspond to collective vibrations or shape coexistence. New and previously reported (n, n' γ) measurements are combined, including γ-γ coincidences, excitation functions, and angular distributions, to extract lifetimes and transition probabilities for 44 excited states up to 2.7 MeV, including 32 previously unmeasured levels. Our results confirm or revise γ-ray placements and provide detailed transition strengths, revealing both weakly collective and strongly enhanced B(E2) and B(E1) transition probabilities. In particular, a tentative 0 + state at 2437.8 keV exhibits a strong interband B(E2) transition, which may be a candidate for a possible two-phonon (ββ) excitation. Systematic comparisons with neighboring Gd isotopes, Hartree–Fock–Bogoliubov, and interacting-boson model predictions suggest that the first excited 0 + state in 158 Gd is predicted to be a β-vibration, although it is weakly collective.

158Gd↗

Comparison of Minority Carrier Lifetime Measurements in Superstrate and Substrate CdTe PV Devices: Preprint

We discuss typical and alternative procedures to analyze time-resolved photoluminescence (TRPL) measurements of minority carrier lifetime (MCL) with the hope of enhancing our understanding of how this technique may be used to better analyze CdTe photovoltaic (PV) device functionality. Historically, TRPL measurements of the fast recombination rate (t1) have provided insightful correlation with broad device functionality. However, we have more recently found that t1 does not correlate as well with smaller changes in device performance, nor does it correlate well with performance differences observed between superstrate and substrate CdTe PV devices. This study presents TRPL data for both superstrate and substrate CdTe devices where both t1 and the slower TRPL decay (t2) are analyzed. The study shows that changes in performance expected from small changes in device processing may correlate better with t2. Numerical modeling further suggests that, for devices that are expected to have similar drift field in the depletion region, effects of changes in bulk MCL and interface recombination should be more pronounced in t2. Although this technique may provide future guidance to improving CdS/CdTe device performance, it is often difficult to extract statistically precise values for t2, and therefore t2 data may demonstrate significant scatter when correlated with performance parameters.

14 SOLAR ENERGY↗

Los Alamos National Laboratory W76 Pit Tube Lifetime Study

A metallurgical study was requested as part of the Los Alamos National Laboratory (LANL) W76-1 life-extension program (LEP) involving a lifetime analysis of type 304 stainless steel pit tubes subject to repeat bending loads during assembly and disassembly operations at BWXT/Pantex. This initial test phase was completed during the calendar years of 2004-2006 and the report not issued until additional recommended tests could be performed. These tests have not been funded to this date and therefore this report is considered final. Tubes were reportedly fabricated according to Rocky Flats specification P14548 - Seamless Type 304 VIM/VAR Stainless Steel Tubing. Tube diameter was specified as 0.125 inches and wall thickness as 0.028 inches. A heat treat condition is not specified and the hardness range specification can be characteristic of both 1/8 and 1/4 hard conditions. Properties of all tubes tested were within specification. Metallographic analysis could not conclusively determine a specified limit to number of bends allowable. A statistical analysis suggests a range of 5-7 bends with a 99.95% confidence limit. See the 'Statistical Analysis' section of this report. The initial phase of this study involved two separate sets of test specimens. The first group was part of an investigation originating in the ESA-GTS [now Gas Transfer Systems (W-7) Group]. After the bend cycle test parameters were chosen (all three required bends subjected to the same amount of bend cycles) and the tubes bent, the investigation was transferred to Terri Abeln (Metallurgical Science and Engineering) for analysis. Subsequently, another limited quantity of tubes became available for testing and were cycled with the same bending fixture, but with different test parameters determined by T. Abeln.

36 MATERIALS SCIENCE↗

Photometric Testing, Laboratory Teardowns, and Accelerated Lifetime Testing of OLED Luminaires (CALiPER Report 24, Supplemented)

OLED luminaires are fairly new to the lighting market. This testing of commercially-available products uses independent photometric testing to evaluate color, electrical, and photometric performance, and has been supplemented in 2017 with two additional OLED luminaires. The report also includes teardown testing and accelerated lifetime testing to help identify areas of improved energy performance, and potential failure points, respectively.

42 ENGINEERING↗

Interim Status of HEPA Filter 10-Year Lifetime Evaluation

High efficiency particulate air (HEPA) filters are widely employed by nuclear facilities to remove used to remove radiological particulate matter from their effluent gas streams. The purpose of this study is to draw a relationship between the HEPA filter lifespan and its performance indicators. The 10 year-long endeavor to collect and analyze data regarding the lifetime of HEPA filters at the Pacific Northwest National Laboratory (PNNL) began in 2010. Forty-nine filters were surveyed and analyzed at least annually to verify compliance with permit conditions. The study suggests the frequency of filter replacement should be based on the actual statistics of the filter and its fume hood instead of on the prescribed filter “age limit” of 10 years from the date of manufacture when operating under dry conditions. Over the past six years, only two filters in the study were replaced—one due to high pressure differential and low fume hood face velocity, and the other due to low filter efficiency results.

54 ENVIRONMENTAL SCIENCES↗

Interim Status of HEPA Filter 10-Year Lifetime Evaluation

High-efficiency particulate air (HEPA) filters are widely employed by nuclear facilities to remove radiological particulate matter from their effluent exhaust streams. The purpose of this study is to evaluate the relationships between the 10-year HEPA filter lifespan and its other performance indicators. The 10-year-long endeavor to collect and analyze data regarding the lifetime of HEPA filters at the Pacific Northwest National Laboratory began in 2019. Forty-nine HEPA filters were selected and have been surveyed and analyzed at least annually to verify compliance with permit conditions. The study suggests the frequency of filter replacement should be based on the actual operational requirements, such as fume hood face velocity and/or efficiency test results, instead of on the prescribed filter “age limit” of 10 years from the date of manufacture (e.g., birth date) when operating under dry conditions. Over the past nine years, only four HEPA filters have been replaced for technical issues.

54 ENVIRONMENTAL SCIENCES↗

Final Status of HEPA Filter 10-Year Lifetime Evaluation

High-efficiency particulate air (HEPA) filters are widely employed by nuclear facilities to remove radiological particulate matter from their effluent exhaust streams. The purpose of this study is to evaluate the relationships between the 10-year HEPA filter lifespan and its other performance indicators. The 10-year-long endeavor to collect and analyze data regarding the lifetime of HEPA filters at the Pacific Northwest National Laboratory began in 2010. Forty-nine HEPA filters were selected and have been surveyed and analyzed at least annually to verify compliance with permit conditions. The study suggests the frequency of filter replacement should be based on the actual operational requirements, such as fume hood face velocity and/or efficiency test results, instead of on the prescribed filter “age limit” of 10 years from the date of manufacture (e.g., birth date) when operating under dry conditions. Over the past decade, the study has now been completed, and all forty-nine HEPA filters have been replaced, due to either technical issues listed in this report, or the previously recommended filter “age limit” of 10 years.

61 RADIATION PROTECTION AND DOSIMETRY↗

PV Lifetime Project - 2025 NLR Annual Report

DOE's PV Lifetime project was initiated in 2016 with the goal of accurately characterizing the early-life evolution of photovoltaic (PV) field performance. Different PV cell and module technologies result in different initial degradation rates due to effects like light-induced degradation (LID) and light and elevated temperature-induced degradation (LeTID). To accurately characterize the initial field degradation of maximum power (Pmp) requires the use of high-accuracy indoor IV curve measurements at standard test conditions. Therefore, PV modules involved in this study are removed from the field once or twice per year and brought indoors for measurement under constant temperature and irradiance conditions. Overall annual degradation rates are as follows: our first modules to be deployed (Jinko, Trina, QCells) have annual median degradation rate between -0.4%/yr and -0.5%/yr mainly concentrated in the first year. Mission Solar, LG and Panasonic modules are all displaying modest degradation, better than -0.3% / year. Indeed, Mission Solar fielded modules degraded less than their control modules which remain indoors and un-exposed. This is also true for the LONGi monofacial modules, which had some field degradation, but not as much as the degradation of the indoor control modules. The LONGi bifacial modules on the other hand have degraded more in the field than their monofacial counterparts, although still a modest amount (-0.4 %/yr). Of the four newest module types in the study, only one has had better than average degradation. REC360NP2 (N-type TOPCon) had a slight performance increase over the first year and a half of field deployment. For the other three new module types (plus one older module type), degradation was more rapid. In our study of 16 module types, four have demonstrated degradation faster than -1%/yr: two N-type Heterojunction, one PERC bifacial and one PERC shingled module. The two heterojunction modules in our study are degrading the most rapidly. Sunpreme n-HIT bifacial modules are showing a loss rate around -1.5%/yr, for over -10% total to date. This is largely attributed to loss in front-side Isc. This is distinct from the REC 405AA-Pure modules which have degraded -6.8% in only a year and a half, for an annualized decline of -3.9 %/yr. For this module type, the decline is roughly half in Voc, with the remaining split between FF and Isc. Of the remaining two module types, Prism Solar PERC bifacial has declined -5% total since 2019, although this loss appears to have stabilized in the most recent measurement. The Solaria PowerX-400R Shingled module type has also lost around -3.2% in the first 1.5 years of field deployment. It remains to be seen if these losses will continue with time.

14 SOLAR ENERGY↗

THE EMISSION, LIFETIMES, AND FORMATION THRESHOLD OF THE VEGARD–KAPLAN TRANSITION OF SOLID NITROGEN EXPOSED TO FAR-ULTRAVIOLET RADIATION

Irradiation of solid nitrogen at 4 K with far-ultraviolet light from a synchrotron caused excitation to the upper state of the Vegard–Kaplan (VK) system; the emission in that system was simultaneously recorded in wavelength region 200–440 nm. The lifetimes of emission lines for VK (0, 1) to (0, 12) transitions were measured in the range of 2.12 ∼ 2.65 s. The threshold wavelength to observe the VK emission was 175.0 ± 3.5 nm, corresponding to energy 7.08 ± 0.14 eV. This investigation of the generation of icy VK nitrogen enhances our understanding of its photochemistry in space.

79 ASTRONOMY AND ASTROPHYSICS↗

SUNSPOT AND STARSPOT LIFETIMES IN A TURBULENT EROSION MODEL

Quantitative models of sunspot and starspot decay predict the timescale of magnetic diffusion and may yield important constraints in stellar dynamo models. Motivated by recent measurements of starspot lifetimes, we investigate the disintegration of a magnetic flux tube by nonlinear diffusion. Previous theoretical studies are extended by considering two physically motivated functional forms for the nonlinear diffusion coefficient D : an inverse power-law dependence D ∝ B {sup −ν} and a step-function dependence of D on the magnetic field magnitude B . Analytical self-similar solutions are presented for the power-law case, including solutions exhibiting “super fast” diffusion. For the step-function case, the heat-balance integral method yields approximate solutions, valid for moderately suppressed diffusion in the spot. The accuracy of the resulting solutions is confirmed numerically, using a method which provides an accurate description of long-time evolution by imposing boundary conditions at infinite distance from the spot. The new models may allow insight into the differences and similarities between sunspots and starspots.

79 ASTRONOMY AND ASTROPHYSICS↗