Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high gradient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

EGS Collab Project Electrical Resistivity Tomography Characterization and Monitoring

The EGS (Enhanced Geothermal Systems) Collab project is performing stimulation experiments in highly monitored and well-characterized intermediate-scale (~10-20 m) field test beds. The characterization and monitoring system includes an array of electrodes grouted in place within six monitoring wells, with 16 electrodes per well. The electrodes enable characterization of the 3D low-frequency electrical properties of the host rock, and changes in those properties during stimulation and tracer testing using both static and time-lapse Electrical Resistivity Tomography. In this talk we present: 1) ERT array design and installation, 2) baseline (pre-stimulation) imaging results, 3) time-lapse data collected during stimulation operations, and 4) real-time imaging during clean water injections intended to illuminate flow paths as a decrease in bulk electrical conductivity. We will also discuss aspects and lessons learned for conducting ERT imaging operations in the presence of high fluid pressure gradients during stimulation and flow operations. Results to date reveal a highly heterogeneous rock fabric, ranging over four orders of magnitude in bulk electrical conductivity, and high polarization capacity. Baseline imaging results are consistent with borehole logs and core studies. Time-lapse imaging results to identify major flow paths during tracer studies are forthcoming and will be discussed during this presentation. Ultimately the ERT imaging data sets provide useful information for validating and verifying model predictions in preparation for research at DOE’s Frontier Observatory for Research in Geothermal Energy (FORGE).

electrical resistivity tomography, geophysics, geo↗

Effects of midplane density gradient in the propagation of high-harmonic fast waves considering high temperature anisotropy in the scrape-off layer of NSTX-U

High-Harmonic Fast Wave (HHFW) heating experiments in NSTX have shown that up to 60% of the injected power can be lost in the Scrape-Off Layer (SOL) when the density is above the fast wave cutoff density in front of the antenna, for which the fast wave is able to propagate into the plasma. This work models HHFW propagation in the SOL plasmas of NSTX-U using a 2D divertor SOL profile derived from the pressure assumption and the finite element temperature solution, which accounts for the high anisotropy of heat conduction in a 2D axisymmetric geometry. In this work, the two-dimensional axisymmetric SOL temperature profile is first evaluated by solving the steady-state non-linear heat conduction equation, in which thermal conductivity depends on temperature, using a finite element approach in the Petra-M workbench. A 2D density profile is then obtained from a prescribed density profile at the outer midplane assuming pressure is uniform along a flux tube in the SOL. This approach results in density and temperature profiles in which the strong asymmetric nature of heat conduction between the parallel and perpendicular background magnetic field is successfully captured. Furthermore, this work focuses on investigating the effect of the SOL plasma density profile on parasitic HHFW propagation in the SOL. The simulation results show that the radial gradient of the density profile affects the wavefield propagation in the SOL. As the density profile broadens, the wavefield intensity and its poloidal extent are reduced in the SOL, and the core coupling increases. Similarly, as shown by collisional power deposition, a proxy for power absorption, the fraction of power deposited in the SOL decreases with a broadening profile.

HHFW↗

Long-Gradient Separations Coupled with Selected Reaction Monitoring for Highly Sensitive, Large Scale Targeted Protein Quantification in a Single Analysis

Long-gradient separations coupled to tandem MS were recently demonstrated to provide a deep proteome coverage for global proteomics; however, such long-gradient separations have not been explored for targeted proteomics. Herein, we investigate the potential performance of the long-gradient separations coupled with selected reaction monitoring (LG-SRM) for targeted protein quantification. Direct comparison of LG-SRM (5 h gradient) and conventional LC-SRM (45 min gradient) showed that the long-gradient separations significantly reduced background interference levels and provided an 8- to 100-fold improvement in LOQ for target proteins in human female serum. Based on at least one surrogate peptide per protein, an LOQ of 10 ng/mL was achieved for the two spiked proteins in non-depleted human serum. The LG-SRM detection of seven out of eight endogenous plasma proteins expressed at ng/mL or sub-ng/mL levels in clinical patient sera was also demonstrated. A correlation coefficient of >0.99 was observed for the results of LG-SRM and ELISA measurements for prostate-specific antigen (PSA) in selected patient sera. Further enhancement of LG-SRM sensitivity was achieved by applying front-end IgY14 immunoaffinity depletion. Besides improved sensitivity, LG-SRM offers at least 3 times higher multiplexing capacity than conventional LC-SRM due to ~3-fold increase in average peak widths for a 300-min gradient compared to a 45-min gradient. Therefore, LG-SRM holds great potential for bridging the gap between global and targeted proteomics due to its advantages in both sensitivity and multiplexing capacity.

Shi, Tujin↗

An x-ray backlit Talbot-Lau deflectometer for high-energy-density electron density diagnostics

X-ray phase-contrast techniques can measure electron density gradients in high-energy-density plasmas through refraction induced phase shifts. An 8 keV Talbot-Lau interferometer consisting of free standing ultrathin gratings was deployed at an ultra-short, high-intensity laser system using K-shell emission from a 1-30 J, 8 ps laser pulse focused on thin Cu foil targets. Grating survival was demonstrated for 30 J, 8 ps laser pulses. The first x-ray deflectometry images obtained under laser backlighting showed up to 25% image contrast and thus enabled detection of electron areal density gradients with a maximum value of 8.1 ± 0.5 × 10 23 cm ₋3 in a low-Z millimeter sized sample. An electron density profile was obtained from refraction measurements with an error of <8%. We found the 50 ± 15 μm spatial resolution achieved across the full field of view was limited by the x-ray source-size, similar to conventional radiography.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pre-flare dynamics of sunspot groups

Several papers provide evidence that the most probable sites of flare onset are the regions of high horizontal magnetic field gradients in solar active regions. Besides the localization of flare-producing areas, this work intends to reveal the characteristic temporal variations in these regions prior to flares. This study uses sunspot data instead of magnetograms and follows the behavior of a suitable defined proxy measure representing the horizontal magnetic field gradient. The source of the data is the SDD (SOHO/MDI-Debrecen Data) sunspot catalog. The most promising pre-flare signatures are the following properties of gradient variation: (1) steep increase, (2) high maximum, (3) significant fluctuation, and (4) a gradual decrease between the maximum and the flare onset that can be related to the 'pull mode' of the current layer. These properties may yield a tool for the assessment of flare probability and intensity within the following 8-10 hr.

79 ASTRONOMY AND ASTROPHYSICS↗

Boundary-Layer Code For Supersonic Combustion

HUD is integral computer code based on Spaulding-Chi method for predicting development of boundary layers in laminar, transitional, and turbulent regions of flows on two-dimensional or axisymmetric bodies. Approximates nonequilibrium velocity profiles as well as local surface friction in presence of pressure gradient. Predicts transfer of heat in turbulent boundary layer in presence of high axial presure gradient. Provides for pressure gradients both normal and lateral to surfaces. Also used to estimate requirements for cooling scramjet engines. Because of this capability, HUD program incorporated into several scramjet-cycle-performance-analysis codes, including SCRAM (ARC-12338) and SRGULL (LEW-15093). Written in FORTRAN 77.

Pinckney, S. Z.↗

Hyperbolic Method for Dispersive PDEs: Same High-Order of Accuracy for Solution, Gradient, and Hessian

In this paper, we introduce a new hyperbolic first-order system for general dispersive partial differential equations (PDEs). We then extend the proposed system to general advection-diffusion-dispersion PDEs. We apply the fourth-order RD scheme of Ref. 1 to the proposed hyperbolic system, and solve time-dependent dispersive equations, including the classical two-soliton KdV and a dispersive shock case. We demonstrate that the predicted results, including the gradient and Hessian (second derivative), are in a very good agreement with the exact solutions. We then show that the RD scheme applied to the proposed system accurately captures dispersive shocks without numerical oscillations. We also verify that the solution, gradient and Hessian are predicted with equal order of accuracy.

Mazaheri, Alireza↗

High-Nickel Cathodes with Mechanical and Interfacial Robustness via Tailored Concentration Gradients for Stable Li-Ion Batteries

Here, we have developed a versatile mathematical framework integrated with an automated reactor system to design and reify highly customizable full concentration gradient (FCG) in high-nickel cathodes for advanced Li-ion batteries. This method provides precise and independent control of the average composition, slope, and curvature of FCGs, enabling the optimization of structural and mechanical properties of the cathode materials. We have showcased this method with Ni 0.8 Co 0.1 Mn 0.1 (OH) 2 precursors of controlled FCGs, which unlocked an optimized cathode with excellent cycling stability without crack formation after repeated cycles. This work opens up new possibilities for the design and manufacturing of advanced cathode materials, enabling safer, high-performance batteries.

25 ENERGY STORAGE↗

In situ dynamic transmission electron microscopy characterization of liquid-mediated crystallization of amorphous Ge

Crystal growth rates during laser-induced, liquid-mediated crystallization of amorphous Ge were measured with movie-mode dynamic transmission electron microscopy (MM-DTEM), a photoemission microscopy technique with nanosecond-scale time resolution. Films of 50-nm thick amorphous Ge were crystallized using a 12-ns laser pulse with a Gaussian spatial profile, which established high local temperature gradients in the specimen. Crystallization proceeded by the formation of a central zone with a high nucleation rate (zone I), followed by liquid-mediated outward growth of columnar grains (zone II), followed by spiraling growth (zone III) until the crystallization halted in cooler parts of the specimen. Zone II growth was imaged for several laser pulse energies with 20-ns electron pulses with 95 ns between frames. A thin liquid layer between the solid amorphous phase and the advancing crystallization front during zone II growth was imaged. The zone II growth rate for each experiment remained nearly constant although the crystallization front passes through a large temperature gradient. Measured growth rates ranged from 5.7 to 13.6 m/s, consistent with transient liquid layer mediated growth rather than solid-state growth. In contrast with a previous report, the growth rate did not increase systematically with laser energy or absorbed energy. The new results, together with previously reported data, suggest that both sets of experiments were conducted under conditions where the growth rate saturates near its maximum value. A phenomenological model based on the concept of upper and lower threshold temperatures for the zone II growth was fitted to the data from these experiments and previous MM-DTEM crystallization experiments.

36 MATERIALS SCIENCE↗

Nozzle material requirements and the status of intermetallic matrix composites

The HSCT exhaust nozzle must manage high temperature exhaust gases and pressure gradients while meeting HSCT economic and noise goals. The important features and requirements for an HSCT exhaust nozzle are shown for a 2DCD (two-dimensional convergent-divergent) design. The same requirements would apply to an axisymmetric design. Exhaust nozzle weight has an adverse effect on the overall aircraft range, payload, and engine specific fuel consumption and is therefore the primary driver for advanced exhaust nozzle materials. Because of the large airflow and pressure gradients, exhaust nozzles are extremely large and heavy when made from current materials. The use of advanced materials with higher specific strength will reduce the weight of exhaust nozzle components. In addition to the flow of high-temperature exhaust gases into the exhaust nozzle, ambient air is entrained to reduce gas exit velocities and suppress sound. This leads to components exposed to extremely high temperature gradients and, hence, high thermal stresses. Further, exhaust gases are highly oxidizing; material environmental resistance will be an important factor for long life. Several viable concepts have been identified to reduce noise through the mixture of exhaust and ambient air. Sound can be further suppressed by acoustic panels that absorb high-frequency noise.

Johnson, Andrew M.↗

3D Quantification of Elemental Gradients within Heterostructured Particles of Battery Cathodes

Heterogenous architectures with elemental gradients tailored within particles have been pursued to combat the instabilities limiting Ni-rich cathode materials for lithium-ion batteries. The growth of different compositional layers is accomplished during the synthesis of hydroxide precursors. However, the extent to which these concentration gradients are modified during high-temperature reactions is difficult to establish in their intact, spherical form. Here, we show the entire three-dimensional structure of a secondary particle can be resolved nondestructively with differential X-ray absorption spectroscopy (XAS) through transmission X-ray microscopy (TXM). The relationship between particle location and elemental content was fully quantified, with high statistical significance, for heterostructures possessing different compositional gradients in the precursors with 90:5:5 Ni:Mn:Co core compositions. Reduced elemental heterogeneity was observed after high-temperature synthesis, but gradients remained. In conclusion, the methodology presented should be used to guide synthesis while assuring that gains in electrochemical performance are linked to precise elemental distributions at the nanoscale.

25 ENERGY STORAGE↗

WE-A-BRD-00: MR Basics II

Ever since its introduction as a diagnostic imaging modality over 30 years ago, the radiation therapy community has acknowledged the utility of MR imaging as a tool for not only improved visualization of the target volume but also for demarcation of adjacent organs at risk. However, the adaptation of MR imaging in radiation oncology has, until recently been slow due in large part to the inability to image radiation therapy patients in their treatment position. With the introduction of so-called wide bore high field MR scanners, multi element flexible receive only RF coils, high performance imaging gradients and a range of volumetric imaging sequences it is now possible to obtain both high resolution and high signal-to-noise ratio images of in-treatment radiation therapy patients within clinically feasible imaging times. As a Result, there is renewed interest in the use of MR imaging for radiation oncology treatment planning that is being translated into physical siting and integration of these systems into radiation oncology departments. As MR imaging expands into the radiation oncology domain there is a significant and unmet need for radiation therapy physicists to become educated regarding the strengths, limitations and technical challenges associated with MR imaging. The purpose of this presentation is to address this need by providing an educational overview of the techniques and challenges associated with MR imaging of patients for radiation therapy treatment planning. As such this presentation will: 1) describe the fundamental differences between imaging of patients for diagnostic and therapeutic purposes (i.e. radiation therapy planning), 2) describe most commonly used imaging sequences and contrasts for identification of disease for radiation planning, 3) identify the most common sources of image distortion and techniques to reduce their effect on spatial fidelity of the MR data, 4) describe the effects of motion and methods to quantify/correct it, and 5) identify emergent techniques for performing MR only treatment simulation. Upon completion attendees will have a working understanding of the basic methodologies associated with MR imaging in radiation oncology, the unique technical challenges imposed by MR imaging in the treatment position and techniques to address these. Learning Objectives: 1. Understand the differences between MR imaging for diagnostic imaging and for radiation therapy planning. 2. Identify the most common sources of distortion and artifacts and simple methods to correct them. 3. Understand the challenges with MR imaging in the therapy treatment position and appropriate techniques to address them.

60 APPLIED LIFE SCIENCES↗

WE-A-BRD-01: MR Imaging for Treatment Planning: What Every Physicist Should Know

Ever since its introduction as a diagnostic imaging modality over 30 years ago, the radiation therapy community has acknowledged the utility of MR imaging as a tool for not only improved visualization of the target volume but also for demarcation of adjacent organs at risk. However, the adaptation of MR imaging in radiation oncology has, until recently been slow due in large part to the inability to image radiation therapy patients in their treatment position. With the introduction of so-called wide bore high field MR scanners, multi element flexible receive only RF coils, high performance imaging gradients and a range of volumetric imaging sequences it is now possible to obtain both high resolution and high signal-to-noise ratio images of in-treatment radiation therapy patients within clinically feasible imaging times. As a Result, there is renewed interest in the use of MR imaging for radiation oncology treatment planning that is being translated into physical siting and integration of these systems into radiation oncology departments. As MR imaging expands into the radiation oncology domain there is a significant and unmet need for radiation therapy physicists to become educated regarding the strengths, limitations and technical challenges associated with MR imaging. The purpose of this presentation is to address this need by providing an educational overview of the techniques and challenges associated with MR imaging of patients for radiation therapy treatment planning. As such this presentation will: 1) describe the fundamental differences between imaging of patients for diagnostic and therapeutic purposes (i.e. radiation therapy planning), 2) describe most commonly used imaging sequences and contrasts for identification of disease for radiation planning, 3) identify the most common sources of image distortion and techniques to reduce their effect on spatial fidelity of the MR data, 4) describe the effects of motion and methods to quantify/correct it, and 5) identify emergent techniques for performing MR only treatment simulation. Upon completion attendees will have a working understanding of the basic methodologies associated with MR imaging in radiation oncology, the unique technical challenges imposed by MR imaging in the treatment position and techniques to address these. Learning Objectives: 1. Understand the differences between MR imaging for diagnostic imaging and for radiation therapy planning. 2. Identify the most common sources of distortion and artifacts and simple methods to correct them. 3. Understand the challenges with MR imaging in the therapy treatment position and appropriate techniques to address them.

60 APPLIED LIFE SCIENCES↗