Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Norms, Norm Sets, and Reference Groups: Implications for Household Interest in Energy Technologies

Household adoption of rooftop solar panels and battery storage can potentially reduce the negative environmental impacts of the electric grid. We argue that the number of socially close (friends and family) and geographically close (neighbors) others who have rooftop solar panels will affect norm expectations regarding how much others approve of solar panels and battery storage and expectations about how personally beneficial those technologies are likely to be. We test our hypotheses using survey data collected from California homeowners and find partial support. We find evidence for the significance of socially close others (rather than neighbors), highlighting the importance of identifying the appropriate reference groups when studying norms. Our results also provide insight into how one category of behavior (adoption of solar panels) can influence norm expectations about another less visible behavior (battery storage), suggesting a mechanism that may contribute to norms regulating private behaviors.

Horne, Christine↗

Market-based Co-optimization of Energy and Ancillary Services with Distributed Energy Resource Flexibilities

Energy storage systems and flexible loads have attracted significant interests due to their capabilities to provide various grid services. In this paper, the flexibilities are optimally allocated among multiple distributed energy resource aggregators with energy storage systems and flexible buildings by the utility coordinator through market-based co-optimization. An iterative market clearing algorithm is developed to determine the optimal energy and ancillary service prices, with consideration of both local dynamics and network constraints. Simulation results demonstrate the effectiveness of the proposed algorithm and the benefits of co-optimizing the energy and ancillary service markets.

Ma, Ke↗

Parametric analysis on optimized design of hybrid solar power plants

There is increasing interest in utility-scale solar power plants with storage which can flexibly dispatch renewable energy to the grid. However, plant design possesses many degrees of freedom and non-obvious trade-offs in performance. Software tools can estimate or optimize the performance of a specific plant configuration under market and weather conditions of interest; the associated cost parameters and operating assumptions strongly influence estimates of plant performance and decisions regarding optimal sizing. We employ the National Renewable Energy Laboratory's Hybrid Optimization and Performance Platform, which incorporates optimal dispatch when evaluating plant performance, and investigate the sensitivity to weather and market conditions, operating limitations, and the presence of a capacity-based incentive. We demonstrate changes in plant performance and optimal sizing with respect to these inputs and discuss implications. Here results show that PV-with-battery designs are more profitable under our assumptions, but that designs including a concentrated solar power (CSP) system produce significantly greater annual energy; and that CSP-with-thermal energy storage designs maximizing the benefit-to-cost ratio have an input-dependent linear relationship between the CSP field solar multiple and the hours of storage as the project budget varies.

14 SOLAR ENERGY↗

Renewable-battery hybrid power plants in congested electricity markets: Implications for plant configuration

Examining coupled renewable-battery power plants (“hybrids”) in congested areas provides insights into a future of increased wind and solar penetration. Our study focuses on two types of congested regions, Variable Renewable Energy (VRE)-rich Areas and Load Centers, and explores likely plant configuration choices for developers and transmission network planners. Here, this paper examines how hybrid value, comprising energy and capacity value, varies by plant configuration and congested region type considering factors such as storage duration, battery degradation, and ability to charge from the grid. We select plant locations from across the seven main U.S. independent system operators (ISOs). Hybrid value for each configuration is computed based on profit-maximizing plant operation given perfect foresight, according to observed wholesale power market real time prices from 2018 to 2021. In VRE-rich Areas, the median increase in energy value from extending storage duration from one to 4h is 29.4% for solar and 26.8% for wind, assuming low battery degradation costs and storage sized to 100% of the plant's nameplate generation capacity. Increasing storage duration beyond 4h does not substantially increase its value from energy markets, even in VRE-rich Areas. We find that solar hybrids reach a 90% capacity credit with 4h of storage, while wind hybrids require 8h of storage, based on the capacity factor of each hybrid during the top 100 net load hours.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart Energy Storage Integration and Management Platform for Buildings (SESIMP-B)

This project involved the design, development, and testing of a commercial smart service panel. It includes an innovative AI-driven control method to manage smart functions of the panel and a technical-economic feasibility assessment for enhancing building energy resilience and grid-edge technology integration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Learning from Arctic Microgrids: Cost and Resiliency Projections for Renewable Energy Expansion with Hydrogen and Battery Storage

Electricity in rural Alaska is provided by more than 200 standalone microgrid systems powered predominantly by diesel generators. Incorporating renewable energy generation and storage to these systems can reduce their reliance on costly imported fuel and improve sustainability; however, uncertainty remains about optimal grid architectures to minimize cost, including how and when to incorporate long-duration energy storage. This study implements a novel, multi-pronged approach to assess the techno-economic feasibility of future energy pathways in the community of Kotzebue, which has already successfully deployed solar photovoltaics, wind turbines, and battery storage systems. Using real community load, resource, and generation data, we develop a series of comparison models using the HOMER Pro software tool to evaluate microgrid architectures to meet over 90% of the annual community electricity demand with renewable generation, considering both battery and hydrogen energy storage. We find that near-term planned capacity expansions in the community could enable over 50% renewable generation and reduce the total cost of energy. Additional build-outs to reach 75% renewable generation are shown to be competitive with current costs, but further capacity expansion is not currently economical. We additionally include a cost sensitivity analysis and a storage capacity sizing assessment that suggest hydrogen storage may be economically viable if battery costs increase, but large-scale seasonal storage via hydrogen is currently unlikely to be cost-effective nor practical for the region considered. While these findings are based on data and community priorities in Kotzebue, we expect this approach to be relevant to many communities in the Arctic and Sub-Arctic regions working to improve energy reliability, sustainability, and security.

25 ENERGY STORAGE↗

Power HIL Validation of a MW-Scale Grid-Forming Inverter's Stabilization of Otherwise Unstable Cases of the Maui Transmission System

This presentation summarizes MW-scale power hardware-in-the-loop experiments using a 2.2 MW grid-forming inverter connected to a real-time electromagnetic transient simulation of the Maui transmission system. The hardware inverter used is a commercially available "off-the-shelf" inverter from a major manufacturer that is capable of operating in grid-forming mode or grid-following mode. The hardware inverter was connected via power hardware-in-the-loop to a real-time model of the year-2023 Maui power system, which consists of a networked transmission system with diverse generation sources. The results of the simulations indicate that with sufficient synchronous machines online, the system is stable without grid-forming inverters, but that as the amount of synchronous machines is reduced, the system becomes unstable. Changing the hardware inverter (scaled up to represent a 30 MW plant) into grid-forming mode mitigates the instability in various low-inertia cases, including a zero-inertia scenario with 100% of generation from PV and wind. This result broadly agrees with pure simulation results.

battery energy storage system↗

Clean Grid Vision: A U.S. Perspective - Chapter 3. Transmission Grid-Supporting Technologies

High renewable penetration will bring different challenges to power system reliability and stability. Reduction of inertia has been of concern for more wide-spread instable events; however, with the advanced control functionalities provided by power electronics interface and proper storage compensation, renewable generators are capable of providing wide-range of grid services that can maintain and improve grid reliability and stability matrices. Many studies and testing has demonstrated those functions and many pilot projects throughout the world had proved the concepts are working.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Eaton High Impact Project (Cooperative Research and Development Final Report)

The NREL team will partner with Eaton to evaluate control strategies for managing Electric bus (E-bus) fleets for grid services. NREL will develop a replicable platform for evaluating EV fleet management and quantifying benefits from grid services. The proposal will cover the technology areas of solar, energy storage, mobility, and buildings.

33 ADVANCED PROPULSION SYSTEMS↗

Influence of Phase-Change Materials and Operating Periods on Load Shifting for Thermal Storage Heat Pumps in European Climate Zones

As the reliance on heat pumps (HPs) for space conditioning increases worldwide, ex-tensive grid strains during utility peak hours are expected. Significant research efforts focus on investigating the use of integrated thermal energy storage (TES) systems to reduce peak energy demands. Conventionally, TES systems are often integrated to store and provide either cooling or heating, but not both. In this work, a single room-temperature phase-change material (PCM)-TES was integrated for dual-mode opera-tion with an R290 air-to-water 10.5 kW (3-Ton) HP. Two PCM melting temperatures (17°C, 22°C) were assessed to investigate their impact on system performance and cost reductions for Milan, Italy (4A); Barcelona, Spain (3A); and Oslo, Norway (6A). HP and HP-TES performance maps were generated using Modelica-based transient models and co-simulated with a prototype residential building using the Spawn of En-ergyPlusTM with simple rule-based controls. Our simulations indicate that PCM-17°C provided annual cost savings at higher peak-to-off-peak cost ratios, as the demand re-duction dominated the savings potential. The recharge energy costs and requirements became more dominant at lower cost ratios, making PCM-22°C more beneficial at lower cost ratios. Finally, despite Oslo's heating-dominated climate, the utility peak hours favor cooling demand reductions, making PCM-17°C more appealing. In all cases, the cost savings potential stabilized between 4 – 10% regardless of cost ratio, suggesting that system-level component and operation control optimization is required to maximize cost savings further.

25 ENERGY STORAGE↗

Vehicle-to-Grid Electric School Bus Commercialization Project

The Vehicle-to-Grid Electric School Bus Commercialization Project was chartered to advance the idea that the batteries in electric vehicles can play a valuable role in supporting the electric grid. As deployment of wind and solar generating resources accelerates to provide an ever-greater share of the nation’s electricity, concurrent investment in solutions that can offset their inherent intermittency will be necessary. Many types of energy storage systems have been proposed, and more than one type will find an economic fit in the grid of the future. Electric vehicle batteries have the potential to provide grid support services in an advantaged manner. The project’s method of exploring this proposition called for development and demonstration of a fleet of vehicle-to-grid (V2G) electric school buses. School buses were chosen because their energy storage capacity is large relative light-duty vehicles; they are typically domiciled in fleet settings; and the number of hours per year they are available for grid support services is high on an absolute basis (generally 80-85% of the hours in a year) and relative to other categories of medium- and heavy-duty vehicles.

33 ADVANCED PROPULSION SYSTEMS↗

CSP Gen3: Liquid-Phase Pathway to SunShot

The United States Department of Energy (DOE) established the Concentrating Solar Power Generation 3 (CSP Gen3) program to promote the development of advanced CSP systems capable of producing electricity at a levelized cost of energy (LCOE) less than $60/MWh, based on criteria published in the CSP Gen3 Roadmap and a subsequent funding opportunity announcement (Gen3 FOA). This report documents the progress and potential of the “Liquid Pathway” to meet these objectives. The Liquid Pathway proposes the use of low-cost molten chloride salts for energy storage, mated with an operationally flexible solar receiver that employs liquid-metal sodium for heat capture and transfer to the storage salt. This approach leverages molten-salt technology from the current state-of-the-art CSP power towers embodied by plants such as Gemasolar, Crescent Dunes, Noor III, and the DEWA 700 CSP project. Furthermore, the design builds on the knowledge gained over decades of use of liquid-metal sodium as a high-temperature heat transfer fluid (HTF) in solar tests and nuclear-power applications. The commercial representation of the proposed Gen3 design incorporates a high-efficiency sodium receiver operating at ~740°C, with a liquid-liquid heat exchanger feeding a two-tank, molten-chloride salt storage system. Chloride salt is dispatched to a supercritical CO 2 (sCO 2 ) power cycle to provide electric power to the grid. The design integration is a conceptual match for the current sodium receiver → solar salt storage → steam-Rankine power cycle promoted by developer Vast Solar, which may facilitate commercial acceptance and development.

14 SOLAR ENERGY↗

Techno-Economic Assessment of Residential Heat Pump Integrated with Thermal Energy Storage

Phase change material (PCM)-based thermal energy storage (TES) can provide energy and cost savings and peak demand reduction benefits for grid-interactive residential buildings. Researchers established that these benefits vary greatly depending on the PCM phase change temperature (PCT), total TES storage capacity, system configuration and location and climate of the building. In this study, preliminary techno-economic performance is reported for a novel heat pump (HP)-integrated TES system using an idealized approach. A simplified HP-TES was modeled for 1 year of space heating and cooling loads for a residential building in three different climates in the United States. The vapor compression system of the HP was modified to integrate with TES, and all heat transfer to and from the TES was mediated by the HP. A single PCM was used for heating and cooling, and the PCT and TES capacity were varied to observe their effects on the building’s energy consumption, peak load shifting and cost savings. The maximum reduction in electric consumption, utility cost and peak electric demand were achieved at a PCT of 30 °C for New York City and 20 °C for Houston and Birmingham. Peak energy consumption in Houston, New York City, and Birmingham was reduced by 47%, 53%, and 70%, respectively, by shifting peak load using a time-of-use utility schedule. TES with 170 MJ storage capacity allowed for maximum demand shift from on-peak to off-peak hours, with diminishing returns once the TES capacity equaled the daily building thermal loads experienced during the most extreme ambient conditions.

25 ENERGY STORAGE↗

Energy Arbitrage: Comparison of Options for use with LWR Nuclear Power Plants

Arbitrage is the opportunistic buying and selling of a commodity during local pricing valleys and peaks respectively to maximize economic value. This report evaluates options for energy arbitrage integrated with existing light water reactor (LWR) nuclear power plants (NPPs) where nuclear energy could be stored in a variety of forms and later recovered to generate electrical power during periods when grid electricity demand and pricing are high. The forms of energy storage examined in this report include the potential value of batteries, hydrogen, and thermal energy storage for coupling with nuclear power. Various large demand response options are also analyzed, including the production of liquid nitrogen via air separation and liquefaction, liquefaction of hydrogen, compressed hydrogen, and the cryogenic capture of CO2. Demand response refers to dispatchable loads that can cycle up or down depending on-grid electricity demand to aid in balancing the grid. Large demand response options could dispatch to aid nuclear power stations in avoiding power turndowns by providing an alternate disposition for electrical energy by producing marketable products (e.g., liquid nitrogen, hydrogen, or captured CO2). Static conditions were chosen and analyzed in this report for each option. Dynamic operation or optimization of energy arbitrage or demand response are out of scope for this report. The analysis is based on storage systems with discharge capacities of 500 MW for which various durations of storage and costs of charging (electricity cost) are examined. While the value of thermal energy to an industrial user for flexible plant operations has been previously proven as a business case, this report evaluates costs of hydrogen energy storage and leading thermal energy storage options, and large demand response loads that could be integrated with LWRs in comparison to utility-scale battery storage for use of off-peak nuclear energy. Compilation of this information will be used by the Idaho National Laboratory (INL) RAVEN/HERON systems integration and economics tool to evaluate thermal energy dispatch to industrial users. Relative ranking of energy storage options was done using a levelized cost of storage (LCOS) metric which calculates a rough breakeven cost for the system, taking into account the capital and operating costs as well as the revenue from arbitrage. Table ES1 below shows the LCOS for each of the energy storage options considered. First, in the table, lithium iron (Fe) phosphate batteries are listed as the base case for comparison against the other options. Next is hydrogen storage where most of the hydrogen analyses assumed the hydrogen to be produced using solid oxide electrolytic cell (SOEC) high temperature steam electrolysis (HTSE). The others used existing models of polymer electrolyte membrane (PEM) low temperature electrolysis to produce hydrogen. HTSE performance parameters and costs were taken from existing INL models. Various means were assumed to convert the hydrogen to electricity, including PEM fuel cells (FCs) and a gas turbine mixed in a 30 vol% mixture with natural gas. Physical storage (pressure vessels) and geological storage (natural underground features) were used to store the hydrogen as noted. Geological storage is more economical, but the locations are limited because of the requirement for pre-existing geological formations that will support storage. Thermal energy storage (TES) options were also analyzed including electro-thermal energy storage (ETES) and four different liquid sensible heat TES storage media as noted (Hitec, Hitec XL, Therminol-66, and Dowtherm A). The ETES process considered was modified using existing public documentation on an Echogen process and uses a separate supercritical CO2 charge and discharge cycle with sand as the heat storage media.

25 ENERGY STORAGE↗

Backup power or bill savings? How electricity tariffs impact residential solar-plus-storage usage in the United States

Adoption of paired solar-plus-storage systems has accelerated in recent years, driven by both the demand for backup power and a desire to manage utility bills. Tradeoffs between those two uses can arise through the reserve setting on the battery storage system, which serves to maintain a minimum state of charge in case of a power interruption. Our paper applies an economic framework to evaluate this tradeoff in terms of changes in bill savings and customer reliability value across reserve levels, considering how those tradeoffs depend on the underlying electricity rate structure and levels. The analysis is based on a representative set of load profiles, solar profiles, tariff designs, and stochastic power interruption events across ten different regions in the United States. We find that the opportunity cost of holding storage capacity in reserve, in terms of foregone bill reductions, outweighs any gains in reliability value from mitigated power interruptions in the majority of customer situations. Higher storage reserve levels increase total customer value only in specific circumstances, such as for customers with inferior reliability (10x average interruptions), with a very high value of lost load ($50/kWh), and with tariff or interconnection rules that disallow grid charging. However, even this result is dampened when considering tariff designs with higher price differentials that increase the opportunity cost of holding storage in reserve (e.g. import/export or time-of-use rates). Allowing grid charging in tariffs essentially eliminates the necessity to hold any storage in reserve in all sensitivity cases explored.

Electric resilience↗

Demonstration of Grid Services Using Mixed Grid-Forming and Grid-Following Technologies at the Wheatridge Renewable Energy Facility (Final Technical Report)

This Final Technical Report summarizes the analytical, modeling, and engineering work performed to evaluate grid-forming (GFM) inverter capabilities within a large hybrid renewable energy facility. The project focused on assessing the ability of advanced inverter-based resources to provide essential reliability services through coordinated operation of grid-forming (GFM) and grid-following (GFL) technologies. During Budget Period 1, the project developed a comprehensive framework of GFM performance metrics, including angle support, voltage regulation, frequency response, damping behavior, and current-limiting performance. Extensive electromagnetic transient (EMT) studies and hardware-in-the-loop (HIL) testing were conducted to validate GFM behavior under a range of operating conditions, including weak-grid scenarios, voltage disturbances, and multi-resource interactions. The project also established validated modeling approaches, plant-level control integration strategies, commissioning frameworks, and high-speed measurement infrastructure to support future field demonstration. Although the project concluded prior to field demonstration, the results provide a utility-scale foundation for evaluating, modeling, and deploying grid-forming technologies. The methodologies and tools developed contribute to industry understanding of inverter-based resource behavior and support future power system reliability under increasing renewable penetration.

14 SOLAR ENERGY↗

Methods for Assessing Opportunities for Ring Dam Pumped Storage Hydropower

There is growing interest in new pumped storage hydropower (PSH) deployment to provide a range of grid flexibility, reliability, and resiliency services under an evolving and uncertain future power sector. The National Laboratory of the Rockies develops open PSH resource assessment and cost modeling tools to help evaluate PSH deployment opportunities, and this report describes expansions to those tools to consider an additional PSH system configuration - ring-dam reservoirs built on flat topographical features that are constructed from roller-compacted concrete material. This reservoir type is common among current PSH proposals and requires new methods to identify sites with this reservoir geometry throughout the United States and characterize the associated dam cost. Cost characterization for ring dam reservoirs required collecting historical dam cost data for earthen, rockfill, and roller-compacted concrete dams and regressing equations that relate costs between alternative materials. The ring dam site identification algorithm follows a 5-step procedure to identify circular geometry reservoirs. Once ring dam reservoirs are identified, they are then paired with potential dry-gully reservoirs, and the full set of potential paired reservoirs is cost-optimized to produce a least-cost set of potential PSH sites with no overlapping reservoirs. The resulting analysis found 1,663 ring-dam to dry-gully systems in the contiguous United States that are lower cost than any overlapping dry-gully to dry-gully systems, 29 in Alaska, and none in Hawaii or Puerto Rico. These systems constitute 1.5 TW of capacity in the contiguous United States and nearly 29 GW in Alaska, demonstrating that under suitable topography and head, ring-dam systems can provide cost-effective PSH opportunities. The greatest density of these opportunities are found in the intermountain west where there are mesas and flat land at bases of mountain ranges, but continued work could incorporate additional site characteristics or consider more complex reservoir shapes to find additional PSH deployment opportunities.

13 HYDRO ENERGY↗