Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “function unit testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Cold-End Subsystem Testing for the Fission Power System Technology Demonstration Unit

The Fission Power System (FPS) Technology Demonstration Unit (TDU) consists of a pumped sodiumpotassium (NaK) loop that provides heat to a Stirling Power Conversion Unit (PCU), which converts some of that heat into electricity and rejects the waste heat to a pumped water loop. Each of the TDU subsystems is being tested independently prior to full system testing at the NASA Glenn Research Center. The pumped NaK loop is being tested at NASA Marshall Space Flight Center; the Stirling PCU and electrical controller are being tested by Sunpower Inc.; and the pumped water loop is being tested at Glenn. This paper describes cold-end subsystem setup and testing at Glenn. The TDU cold end has been assembled in Vacuum Facility 6 (VF 6) at Glenn, the same chamber that will be used for TDU testing. Cold-end testing in VF 6 will demonstrate functionality; validated coldend fill, drain, and emergency backup systems; and generated pump performance and system pressure drop data used to validate models. In addition, a low-cost proof-of concept radiator has been built and tested at Glenn, validating the design and demonstrating the feasibility of using low-cost metal radiators as an alternative to highcost composite radiators in an end-to-end TDU test.

Briggs, Mazwell↗

Overview of MultiLayer Metal Insulation Development for Small Stirling Convertors at NASA Glenn Research Center

A small Stirling convertor is currently under development at the NASA Glenn Research Center to produce one watt of electrical power from eight watts of heat. Previous radioisotope power systems made use of the General-Purpose Heat Source (GPHS) which produces 250 watts of heat but is unsuitable for a one-watt Stirling convertor. The only other qualified heat source available is the Light-Weight Radioisotope Heating Unit (LWRHU), which produces one watt of heat and is primarily used to provide heat to electronics and instrumentation to maintain their appropriate operating temperature. Unfortunately, the LWRHU has a heat flux of 272 W/meters squared compared to the GPHS heat flux of 6000 W/m2 which greatly increases the demands on the insulation to ensure that enough of the heat produced is available to the convertor and not lost to the environment. An analysis was performed that showed that the insulation must have an effective thermal conductivity of 0.005 W/m·K or better for the system to function. A multi-layer metal insulation package was designed and a prototype was fabricated and tested to investigate the feasibility of this design. While the prototype did not meet the requirements perfectly, the lessons learned are being used to generate an improved thermal model using the test data so that a second iteration can developed that will meet the performance requirements with a much higher confidence.

Daniel D Goodell↗

Spatial Characterization of PACE OCI ETU Using Time-Delay Mode

The OCI (Ocean Color Instrument) is the main sensor on the upcoming PACE (Plankton Aerosol Cloud ocean Ecosystem) mission. OCI has two hyperspectral CCD sensors covering 340nm to 885nm and 9 SWIR (Short Wave IR) bands from 940nm to 2260nm. SWIR bands have nominal 1km ground pixel size and CCD bands have native 1/8 km ground pixel size in diagnostic mode that will be aggregated into 1km pixels to improve SNR and meet the data rate constraints. OCI has a rotating telescope that is synchronized to the readout of the CCD and SWIR detectors. Full pre-launch system level testing for the OCI ETU (Engineering Test Unit) was completed in June 2021.With time-delayed scan mode, a sub-pixel level time-delay step is applied to the detector readout. This sub-pixel level time-delay step causes a sub-pixel level shift in the start of the data collection. After collecting time-delay step scans with different step sizes, a scan profile with sub-pixel resolution can be constructed. 1/8 and 1/4 of CCD pixel resolutions were achieved using this mode. In this paper, the OCI time-delayed scan mode will be described as well as how it was used to calculate OCI’s high spatial resolution PSF (Point Spread Function), IFOV (instantaneous Field of View), MTF (Modulation Transfer Function), and BBR (Band to Band Registration).

PACE↗

Cryogenic optical beam steering for superconducting device calibration

We have developed a calibration system based on a micro-electromechanical systems (MEMS) mirror that is capable of delivering an optical beam over a wavelength range of 180 -- 2000 nm (0.62 -- 6.89 eV) in a sub-Kelvin environment. This portable, integrated system can steer the beam over a $\sim$3 cm $\times$ 3 cm area on the surface of any sensor with a precision of $\sim$100 $μ$m, enabling characterization of device response as a function of position. This fills a critical need in the landscape of calibration tools for sub-Kelvin devices, including those used for dark matter detection and quantum computing. These communities have a shared goal of understanding the impact of ionizing radiation on device performance, which can be pursued with our system. This paper describes the design of the first-generation calibration system and the results from successfully testing its performance at room temperature and 20 mK.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Polyhalohydrins: Investigating Vicinal Functionalities by Ring-Opening of Epoxides on Polyolefins

Halohydrins are functional groups that are underexplored in polymer science. This study synthesized and examined structure–property relationships of halohydrin-functionalized polymers derived from polycyclooctene (PCOE), which was obtained via ring-opening metathesis polymerization (ROMP). The polyhalohydrins, including polychlorohydrin, polybromohydrin, and polyiodohydrin, were produced through a two-step process involving epoxidation of PCOE followed by epoxide ring-opening using hydrochloric, hydrobromic, or hydroiodic acid. These stereoirregular and regioirregular polymers are amorphous as measured by differential scanning calorimetry and X-ray scattering. Lap joint shear testing revealed an enhanced adhesive performance in polychlorohydrin and polybromohydrin, with the former demonstrating nearly three times the ultimate shear stress compared to a model polyethylene, hydrogenated PCOE. Additionally, contact angle measurements and surface free energy analysis showed an increase in hydrophilicity and polarity from iodine- to bromine- to chlorine-functionalized polyhalohydrins, aligning with trends in adhesion strength. Furthermore, these results underscore the potential of halohydrin functionalization as a versatile approach for tuning surface properties, offering new opportunities for polymer-to-polymer transformations.

Functional groups↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Energizer Bunny: Dual-Use Photovoltaic and Pasture-Raised Rabbit Farms (Final Report)

This case study project lays the groundwork for the broader realization of agrivoltaics by considering the techno-economic, environmental, and social aspects of system development and assessing a novel rabbit-based concept. Research on the social and political barriers to agrivoltaic development is sparse, which emphasizes the importance of this project as it provides key insight into the consequential socio-political challenges that may hinder the diffusion of agrivoltaic technology. Additionally, the rabbit agrivoltaic concept is novel and has not been applied in experimental or commercial applications to date. This project advances our understanding of the viability of this co-location scheme through empirical assessment of integrating grazing rabbits with solar. A total of five manuscripts (3 published in peer-reviewed journals, 2 under review) have resulted from this project. The techno-economic component of the project included a) a pilot test study investigating the feasibility of the rabbit agrivoltaic concept and b) an economic analysis of the advantages available to solar operators who leverage grazing animals for lawn maintenance and a dual-revenue stream. Our calculations indicate that the co-location of solar and rabbit farms is a viable form of agrivoltaics, increasing overall site revenue by 2.5%-24.0% above projected electricity revenue. The environmental component of the project entailed an ISO 14040 and 14044 compliant life cycle assessment to quantify the impacts of the rabbit agrivoltaic concept. The results indicate pasture-based agrivoltaic systems provide a dual synergy that produces 69.3% less emissions and demands 82.9% less fossil energy per functional unit of cumulative MWh output of electricity and cumulative kg of meat compared to non-integrated production. The social component of the project included conducting two separate interview studies with agriculture and solar industry professionals and the distribution of a public survey. The interview findings identify the key socio-political opportunities for agrivoltaics include: the retention of agricultural land and rural interests, and increased local level acceptance of solar development. The key barriers to agrivoltaics include: ensuring long term agricultural productivity is not compromised, and subnational zoning strategies. The survey results indicate that support for local solar projects increase by 10% when an agricultural function is incorporated. Survey respondents prefer agrivoltaic projects that are a) designed to provide economic opportunities for farmers and the local community b) located on private property or existing agricultural land, and c) do not threaten local interests. Cumulatively, this project can inform agrivoltaic decision making, solar development practices, rabbit-based applications, land use management, and policy making in a way that supports the furtherance of the renewable energy transition, conserves arable land, and utilizes innovative solar photovoltaic technologies.

14 SOLAR ENERGY↗

Robust Automatic EXAFS First-Shell Fits

Extended X-ray absorption fine structure (EXAFS) is a widely used technique for atomic structure determination. Fourier transformation connects EXAFS in k space and R space. However, determining the appropriate k-range for the transformation can be challenging, but critical for the first-shell fit. In this study, we present an automatic method to determine the k-range using the Larch package and a Python program. The first step is to estimate spectral noise across a series of k-ranges with a fixed minimum value and identify the optimal maximum value in the k-range (k max ). The k max is determined by an empirical noise threshold that marks the point where the noise level in the Fourier transformed spectrum changes dramatically. Using the obtained k max value, the first shell is modeled to determine the minimum k value (k min ) by optimizing the background function through alignment of the spectrum with theory. The optimal k min corresponds to the point of the minimum R-factor, which quantifies the difference between the experimental and fitted spectrum. Our method was tested on various typical datasets and yielded suitable k-ranges for Fourier transformation and accurate first-shell fits. This approach helps avoid unreliable, irreproducible data analysis, especially for noisy data from diluted samples, and enables robust automatic first-shell EXAFS fitting.

EXAFS analysis↗

Attention to quantum complexity

The imminent era of error-corrected quantum computing demands robust methods to characterize quantum state complexity from limited, noisy measurements. We introduce the Quantum Attention Network (QuAN), a classical artificial intelligence (AI) framework leveraging attention mechanisms tailored for learning quantum complexity. Inspired by large language models, QuAN treats measurement snapshots as tokens while respecting permutation invariance. Combined with our parameter-efficient miniset self-attention block, this enables QuAN to access high-order moments of bit-string distributions and preferentially attend to less noisy snapshots. We test QuAN across three quantum simulation settings: driven hard-core Bose-Hubbard model, random quantum circuits, and toric code under coherent and incoherent noise. QuAN directly learns entanglement and state complexity growth from experimental computational basis measurements, including complexity growth in random circuits from noisy data. In regimes inaccessible to existing theory, QuAN unveils the complete phase diagram for noisy toric code data as a function of both noise types, highlighting AI’s transformative potential for assisting quantum hardware.

Kim, Hyejin [Cornell Univ., Ithaca, NY (United Sta↗

Ultrafast Photoflash Synthesis of High-Entropy Oxide Nanoparticles

High-entropy metal oxides (HEOs) have recently received growing attention for broad energy conversion and storage applications due to their tunable properties. HEOs typically involve the combination of multiple metal cations in a single oxide lattice, thus bringing distinctive structures, controllable elemental composition, and tunable functional properties. Many synthesis methods for HEOs have been reported, such as solid-state reactions and carbon thermal shock methods. These methods frequently are energy-intensive or require relatively expensive heating equipment. In this work, we report an ultrafast photoflash synthesis method for HEO nanoparticles on diverse substrates. The energy input is provided by a commercial Xe photoflash unit, which triggers exothermic reactions to convert metal salt precursors to HEO nanoparticles within tens of milliseconds. The formation of HEO nanoparticles is attributed to the ultrafast heating (∼106 K/s) and cooling (∼105 K/s) rates of the photoflash and overall high temperature (>1000 K) during the ultrafast synthesis process. When the synthesized CoNiFeCrMn oxide (HEO) is tested as an oxygen evolution reaction electrocatalyst, it shows similar activity to similar materials prepared by other methods. We believe this photoflash synthesis provides a simple method for many others to synthesize diverse HEOs and explore their properties and potential applications.

exothermic reaction synthesis↗

Generalizing Microbial Parameters in Soil Biogeochemical Models: Insights From a Multi‐Site Incubation Experiment

Abstract Incorporating microbial processes into soil biogeochemical models has received growing interest. However, determining the parameters that govern microbially driven biogeochemical processes typically requires case‐specific model calibration in various soil and ecosystem types. Here each case refers to an independent and individual experimental unit subjected to repeated measurements. Using the Microbial‐ENzyme Decomposition model, this study aimed to test whether a common set of microbially‐relevant parameters (i.e., generalized parameters) could be obtained across multiple cases based on a two‐year incubation experiment in which soil samples of four distinct soil series (i.e., Coland, Kesswick, Westmoreland, and Etowah) collected from forest and grassland were subjected to cellulose or no cellulose amendment. Results showed that a common set of parameters controlling microbial growth and maintenance as well as extracellular enzyme production and turnover could be generalized at the soil series level but not land cover type. This indicates that microbial model developments need to prioritize soil series type over plant functional types when implemented across various sites. This study also suggests that, in addition to heterotrophic respiration and microbial biomass data, extracellular enzyme data sets are needed to achieve reliable microbial‐relevant parameters for large‐scale soil model projections.

58 GEOSCIENCES↗

APU diaphragm testing. Test plan

Auxiliary Power Unit (APU) fuel (hydrazine) tanks have had to be removed from the Columbia Shuttle (OV-102) because they have been in service for 11 years, which is the limit of their useful life. As part of an effort to determine whether the useful life of the fuel tanks can be extended, examination of the ethylene propylene rubber (EPR) diaphragm and the metal from one of the APU tanks is required. The JSC Propulsion and Power Division has requested White Sands Test Facility (WSTF) to examine the EPR diaphragm thoroughly and the metal casing generally from one tank. The objective is to examine the EPR diaphragm for signs of degradation that may limit the life of its function in the APU propellant tank. The metal casing will also be examined for signs of surface corrosion.

Shelley, Richard↗

US experiments flown on the Soviet biosatellite Cosmos 2044. Volume 1: Mission description, experiments K-7-01 - K-7-15

Cosmos 2044 was launched on September 15, 1989, containing radiation dosimetry experiments and a biological payload including two young male rhesus monkeys, ten adult male Wistar rats, insects, amphibians, protozoa, cell cultures, worms, plants and fish. The biosatellite was launched from the Plesetsk Cosmodrome in the Soviet Union for a mission duration of 14 days, as planned. The major research objectives were: (1) Study adaptive response mechanisms of mammals during flight; (2) Study physiological mechanisms underlying vestibular, motor system and brain function in primates during early and later adaptation phases; (3) Study the tissue regeneration processes of mammals; (4) Study the development of single-celled organisms, cell cultures and embryos in microgravity; (5) Study radiation characteristics during the mission and investigate doses, fluxes and spectra of cosmic radiation for various types of shielding. American and Soviet specialists jointly conducted 29 experiments on this mission including extensive preflight and post flight studies with rhesus monkeys, and tissue processing and cell culturing post flight. Biosamples and data were subsequently transferred to the United States. The U.S. responsibilities for this flight included development of flight and ground-based hardware, the preparation of rat tissue sample procedures, the verification testing of hardware and experiment procedures, and the post flight analysis of biospecimens and data for the joint experiments. The U.S. investigations included four primate experiments, 24 rat experiments, and one radiation dosimetry experiment. Three scientists investigated tissue repair during flight for a subgroup of rats injured preflight by surgical intervention. A description of the Cosmos 2044 mission is presented in this report including preflight, on-orbit and post flight activities. The flight and ground-based bioinstrumentation which was developed by the U.S. and U.S.S.R. is also described, along with the associated preflight testing of the U.S. hardware.

Connolly, James P.↗

Constructing Highly Porous Low Iridium Anode Catalysts Via Dealloying for Proton Exchange Membrane Water Electrolyzers

Iridium (Ir) is the most active and durable anode catalyst for the oxygen evolution reaction (OER) for proton exchange membrane water electrolyzers (PEMWEs). However, their large-scale applications are hindered by high costs and scarcity of Ir. Lowering Ir loadings below 1.0 mgcm -2 causes significantly reduced PEMWE performance and durability. Therefore, developing efficient low Ir-based catalysts is critical to widely commercializing PEMWEs. Herein, an approach is presented for designing porous Ir metal aerogel (MA) catalysts via chemically dealloying IrCu alloys. In this study, the unique hierarchical pore structures and multiple channels of the Ir MA catalyst significantly increase electrochemical surface area (ECSA) and enhance OER activity compared to conventional Ir black catalysts, providing an effective solution to design low-Ir catalysts with improved Ir utilization and enhanced stability. An optimized membrane electrode assembly (MEA) with an Ir loading of 0.5 mg Ir cm -2 generated 2.0 A cm -2 at 1.79 V, higher than the Ir black at a loading of 2.0 mg Ir cm -2 (1.63 A cm -2 ). The low-Ir MEA demonstrated an acceptable decay rate of ≈40 µV h -1 during durability tests at 0.5 (>1200 h) and 2.0 A cm -2 (400 h), outperforming the commercial Ir-based MEA (175 µV h -1 at 2.0 mg Ir cm -2 ).

36 MATERIALS SCIENCE↗

Polymer connectivity governs electrophotocatalytic activity in the solid state

The reductive functionalization of inert substrates such as chloroarenes is a critical yet challenging transformation relevant to both environmental remediation and organic synthesis. Combining electricity and light is an emerging strategy to access the deeply reducing potentials required for single electron transfer to chloroarenes, yet this approach is limited by poor stability and mechanistic ambiguity. Here, in this work, we demonstrate heterogeneous electrophotocatalysis using redox-active rylene diimide polymers for the reduction of chloroarenes. We find that the electrophotocatalytic activity varies dramatically as a function of the rylene diimide and the redox-inactive polymer backbone. In particular, a flexible, non-conjugated perylenediimide polymer outperforms all other tested electrophotocatalysts. Transient absorption spectroscopy reveals that precomplexation between the doubly reduced perylenediimide and the haloarene substrate is key to productive catalysis. Overall, this work highlights heterogeneous electrophotocatalysis using insoluble redox-active organic materials and provides critical structure–property insights into solid-state electrophotocatalytic activity, informing the development of next-generation materials for sustainable synthesis.

electrocatalysis↗

The AMACStar ASIC for the HL-LHC ATLAS ITk Strip detector: design, verification, testing, and quality assurance

For the high-luminosity upgrade to the LHC (HL-LHC), the ATLAS detector at CERN requires an all-new inner detector, the Inner Tracker (ITk). The ITk Strip subdetector is made up of silicon modules, which include three types of radiation-hard ASICs. One of these is the Autonomous Monitor and Control (AMAC). The AMAC is manufactured by Global Foundries using 130 nm CMOS8RF DM technology and is approximately 3 by 5 mm in size. This ASIC autonomously monitors the temperatures, voltages, and currents in the module components while controlling critical values in order to prevent these quantities from reaching dangerous levels. The final design, AMACStar, was verified, tested, and ensured to perform all necessary functions. A quality control procedure using an in-house probe station set-up was developed in order to ensure that every individual chip on each wafer of AMACStars required by the ITk Strip project met performance requirements. The average per wafer yield of usable AMACStars is 92.33%, exceeding the design-specific 90% yield estimated for project costing. This estimate was based on actual yields for similar designs in this process.

Analogue electronic circuits↗

Investigation of SIR-B images for lithologic mapping

It is immediately apparent from the examination of almost any synthetic aperture radar (SAR) data that the radar return is primarily a function of the topographic relief. Yet radar reflectance is dependent on both surface roughness and the dielectric constant of the surface material. These two parameters can in many cases be related to lithologic units. Thus, if the first-order terrain effects due to topographic relief could (in essence) be removed from the radar image, the SAR data might well be used for lithologic discrimination. Such an approach is evaluated. Landsat Thematic Mapper data along with ground truth are used to define training cells that characterize the various lithologic units in the area. By aggregating the radar data for these cells, curves of radar reflectance versus local incidence are estimated. The curves are then used to classify the test area. The results are compared with lithologic classification based upon multi-spectral (visible and infrared) data.

Parr, J. T.↗