Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Observation and measurement of molecular flow using stimulated Raman gain spectroscopy

The observation and measurement of frequency shifts in stimulated Raman gain spectroscopy resulting from subsonic molecular nitrogen flows emerging from a simple nozzle are reported. The flow velocity in the region of the measurement was determined to be 145 m/s with an accuracy of plus or minus 30 m/s. It is expected that significantly better flow-velocity resolution will be obtained in future experiments using inverse Raman scattering.

Herring, G. C.↗

Bistatic image processing for a 32 x 19 inch model aircraft using scattered fields obtained in the OSU-ESL compact range

Inverse Synthetic Aperture Radar (ISAR) images for a 32 in long and 19 in wide model aircraft are documented. Both backscattered and bistatic scattered fields of this model aircraft were measured in the OSU-ESL compact range to obtain these images. The scattered fields of the target were measured for frequencies from 2 to 18 GHz with a 10 MHz increment and for full 360 deg azimuth rotation angles with a 0.2 deg step. For the bistatic scattering measurement, the compact range was used as the transmitting antenna; while, a broad band AEL double ridge horn was used as the receiving antenna. Bistatic angles of 90 deg and 135 deg were measured. Due to the size of the chamber and target, the receiving antenna was in the near field of the target; nevertheless, the image processing algorithm was valid for this case.

Lee, T-H.↗

An Investigation of the Natural Frequencies and Mode Shapes of Liquids in Oblate Spheroidal Tanks

An experimental investigation was conducted to gain some understanding of the character of the free vibration modes of liquids In oblate spheroidal tanks applicable in missile and space vehicle systems, Measured natural frequencies were obtained for the lowest three or four, antisymmetric modes of oscillation as a function of the liquid depth for three orientations of each of several such tanks of different size and oblateness. The orientations considered were such that: (a) the equator of the spheroid was horizontal and oscillations were along a diameter of the circular liquid surface; (b) the equator of the spheroid was vertical and the oscillations were along the minor axis of the elliptical liquid surface; and (c) the equator of the spheroid was vertical and the oscillations were along the major axis of the elliptical liquid surface; The frequency data are presented as dimensionless parameters developed for each orientation to permit the application of the experimental results to the prediction of the natural frequencies of tanks of different size and oblateness. Photographs we re made of representative surface wave or mode, shapes for each orientation.

Leonard, H. Wayne↗

Propionitrile in the Two Lowest Excited Vibrational States in the Laboratory and on Titan

The rotational spectrum of propionitrile (ethyl cyanide, C2H5CN) in the two lowest excited vibrational states, ν(sub 13) = 1 and ν(sub 21) = 1, was studied in detail. The compiled experimental data set consisted of published line lists, lines measured from published spectra up to 645 GHz, and new measurements at frequencies from 8 to 331 GHz. The two states are subject to considerable mutual interaction but application of a- and b-axis Coriolis coupling model to the measured A-symmetry internal rotation substate transitions was found to be successful. A total of over 1900 transitions were fitted for J values up to 76 and Ka up to 24, resulting in determined vibrational separation between the two states ΔE = 6:2070246(14) cm(exp -1), and Coriolis coefficients |ζ(sup a)(sub 13,21)| = 0.378, |ζ(sup b) (sub 13,21)| = 0.127, in good agreement with quantum chemistry calculations. The new line catalog was used to model ALMA spectra of Titan’s atmosphere from 2016, fitting many weak lines not previously modeled. By including the vibrationally excited lines of C2H5CN and a new partition function, we derive a disk-averaged volume mixing ratio estimate in 2016 of 7.8 ± 0.2 ppb assumed constant above 300 km.

Analysis of rotational spectrum↗

Radio-Frequency Tank Eigenmode Sensor for Propellant Quantity Gauging

Although there are several methods for determining liquid level in a tank, there are no proven methods to quickly gauge the amount of propellant in a tank while it is in low gravity or under low-settling thrust conditions where propellant sloshing is an issue. Having the ability to quickly and accurately gauge propellant tanks in low-gravity is an enabling technology that would allow a spacecraft crew or mission control to always know the amount of propellant onboard, thus increasing the chances for a successful mission. The Radio Frequency Mass Gauge (RFMG) technique measures the electromagnetic eigenmodes, or natural resonant frequencies, of a tank containing a dielectric fluid. The essential hardware components consist of an RF network analyzer that measures the reflected power from an antenna probe mounted internal to the tank. At a resonant frequency, there is a drop in the reflected power, and these inverted peaks in the reflected power spectrum are identified as the tank eigenmode frequencies using a peak-detection software algorithm. This information is passed to a pattern-matching algorithm, which compares the measured eigenmode frequencies with a database of simulated eigenmode frequencies at various fill levels. A best match between the simulated and measured frequency values occurs at some fill level, which is then reported as the gauged fill level. The database of simulated eigenmode frequencies is created by using RF simulation software to calculate the tank eigenmodes at various fill levels. The input to the simulations consists of a fairly high-fidelity tank model with proper dimensions and including internal tank hardware, the dielectric properties of the fluid, and a defined liquid/vapor interface. Because of small discrepancies between the model and actual hardware, the measured empty tank spectra and simulations are used to create a set of correction factors for each mode (typically in the range of 0.999 1.001), which effectively accounts for the small discrepancies. These correction factors are multiplied to the modes at all fill levels. By comparing several measured modes with the simulations, it is possible to accurately gauge the amount of propellant in the tank. An advantage of the RFMG approach of applying computer simulations and a pattern-matching algorithm is that the Although there are several methods for determining liquid level in a tank, there are no proven methods to quickly gauge the amount of propellant in a tank while it is in low gravity or under low-settling thrust conditions where propellant sloshing is an issue. Having the ability to quickly and accurately gauge propellant tanks in low-gravity is an enabling technology that would allow a spacecraft crew or mission control to always know the amount of propellant onboard, thus increasing the chances for a successful mission. The Radio Frequency Mass Gauge (RFMG) technique measures the electromagnetic eigenmodes, or natural resonant frequencies, of a tank containing a dielectric fluid. The essential hardware components consist of an RF network analyzer that measures the reflected power from an antenna probe mounted internal to the tank. At a resonant frequency, there is a drop in the reflected power, and these inverted peaks in the reflected power spectrum are identified as the tank eigenmode frequencies using a peak-detection software algorithm. This information is passed to a pattern-matching algorithm, which compares the measured eigenmode frequencies with a database of simulated eigenmode frequencies at various fill levels. A best match between the simulated and measured frequency values occurs at some fill level, which is then reported as the gauged fill level. The database of simulated eigenmode frequencies is created by using RF simulation software to calculate the tank eigenmodes at various fill levels. The input to the simulations consists of a fairly high-fidelity tank model with proper dimensions and including internal tank harare, the dielectric properties of the fluid, and a defined liquid/vapor interface. Because of small discrepancies between the model and actual hardware, the measured empty tank spectra and simulations are used to create a set of correction factors for each mode (typically in the range of 0.999 1.001), which effectively accounts for the small discrepancies. These correction factors are multiplied to the modes at all fill levels. By comparing several measured modes with the simulations, it is possible to accurately gauge the amount of propellant in the tank. An advantage of the RFMG approach of applying computer simulations and a pattern-matching algorithm is that the

Zimmerli, Gregory A.↗

Sensors with Intelligent Measurement Platform and Low-cost Equipment (SIMPLE) – Performance Characterization

Design and performance of a digital signal processing platform for enhancing off-the-shelf voltage and current sensors are presented. The platform was developed for enabling advanced distribution grid applications with existing low-cost sensors. This digital sensor system leverages a variety of off-the-shelf voltage and current sensing technologies, analog-to-digital conversion, and sensor correction algorithms to yield more accurate and reliable digital measurements that support a multitude of applications and use cases. Sample performance and accuracy results are provided, including measurements at power frequency and higher harmonics. The system extends the native performance of the medium voltage sensors used in the system, for example, broadening measurement bandwidth beyond a few kHz, appropriate for measuring switching surges and harmonics on medium voltage distribution systems. The digital sensor system is installed and characterized in the field with a high-bandwidth optical calibration system to determine site-dependent calibration and performance issues.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measured indoor PM2.5, black carbon, and oxidative potential before and after replacing gas with induction cooking in asthmatic households

Cooking is a major source of fine particulate matter (PM) in homes and evidence to date is inconclusive about the impact of cooking fuel on measures of residential PM exposure. The Cooking Energy and Ventilation Impacts on Children's Asthma (CEVICA) study measured cooking frequency, range hood use, indoor air quality (IAQ) and respiratory health indicators of children with asthma living in homes with gas stoves in California's San Joaquin Valley. Intensive measurements occurred over three 2-week intensive periods: at baseline and at the end of two consecutive 3-month study phases. Participants were randomly assigned to have their gas stoves replaced with electric induction at the start of Phase 1 or Phase 2. As part of the IAQ assessment, we collected particulate matter on Teflon filters using ultrasonic personal air samplers (UPAS). The filters were analyzed to quantify time-integrated PM 2.5 mass concentration, black carbon (BC) oxidative potential (OP). OP was measured using the SLF-OH assay, an acellular chemical assay that quantifies production of OH radicals in simulated lung fluid (SLF). Across all comparisons, PM 2.5 mass tended to be higher during gas cooking than induction electric cooking, although only one transition (Baseline to Phase 1) was statistically discernible at p<0.05. BC and mass-normalized OP showed no measurable differences across stove types or across phases. These preliminary findings suggest that stove fuel alone may not be the dominant determinant of indoor PM 2.5 concentrations in this sample, as previous studies have reported that indoor PM 2.5 during cooking can also be influenced by factors such as cooking practices, food and oil type, kitchen ventilation, and outdoor infiltration.

Lin, Zhuoying↗

High-resolution measurements and analysis of (N-14)(O-16)2 in the (001)-(000) and (011)-(010) bands

High-resolution spectra of NO2 were recorded with a Fourier-transform spectrometer, covering transitions in the (001)-(000) and (011)-(010) bands from 1540 to 1662/cm. The measured line frequencies were used with additional data taken from studies at microwave and far-IR frequencies in an analysis to obtain spin-rotation constants and rotational energies of levels in the (001) and (011) states. Line strengths of these two bands were also measured and analyzed. The analyses included spin-rotation levels of the (001) state for Ka up to and including 13 and N to 73 and those of the (001) state for Ka up to and including 7 and N to 55. The study included observed and enhanced Ka = 5 - 6 transitions in the (020)-(000) band that interact, by means of a Coriolis-type interaction, with Ka = 5 transitions in the (011)-(000) band. Also observed and analyzed were the results of spin-rotation resonance interactions between two levels of the same state. These perturbations affected one or more levels of a given Ka and state and were observed for Ka = 0 with Ka = 2 and Ka = 1 with Ka = 3 for the (001) and (000) states and for Ka = 0 with Ka = 2 for the (011) and (001) states.

Toth, Robert A.↗

Preparation and Fluorescence Anisotropy Study of a Ribonuclease-Lucifer Yellow Conjugate

We have prepared a chemical derivative of ribonuclease A (RNase) with lucifer yellow (LY). The rotational dynamics of the LY-RNase conjugate were characterized by steady state and time resolved fluorescence techniques. Steady state anisotropy measurements were performed at varying viscosities at 10C and 20C, and the rotational correlation time of both RNase and the covalently linked LY probe were determined by time resolved frequency domain measurements. Our data suggest that the fluorophore is rigidly bound at 10C.

Malone, C. C.↗

Vortex shedding from solid rocket propellant inhibitors

Vortex shedding frequency caused by the protrusion of inhibitors into the flow field of a solid rocket motor is investigated by experimental and mathematical models. The time dependent Navier-Stokes equations are solved using a finite difference technique assuming incompressible, two-dimensional flow under both laminar and turbulent flow conditions. For laminar flow, explicit solutions are obtained using a vorticity-transport equation in place of the Navier-Stokes equations. For turbulent flow, a two-equation (k-epsilon) model is used for turbulent modeling and the SIMPLE algorithm is employed as the computational scheme. Cold flow tests were conducted to confirm the basic flow structure and to determine the vortex shedding frequency under both laminar and turbulent flow conditions. The vortex shedding frequencies were determined using a stroboscope to measure the oscillating frequency of yarn tufts which were fastened to one inhibitor in the models. A hot-film anemometer established the velocity history behind the inhibitor. Good agreement between the theoretical results and measurements of the vortex shedding frequencies is demonstrated.

Shu, P. H.↗

Finite Element Modeling of the NASA Langley Aluminum Testbed Cylinder

The NASA Langley Aluminum Testbed Cylinder (ATC) was designed to serve as a universal structure for evaluating structural acoustic codes, modeling techniques and optimization methods used in the prediction of aircraft interior noise. Finite element models were developed for the components of the ATC based on the geometric, structural and material properties of the physical test structure. Numerically predicted modal frequencies for the longitudinal stringer, ring frame and dome component models, and six assembled ATC configurations were compared with experimental modal survey data. The finite element models were updated and refined, using physical parameters, to increase correlation with the measured modal data. Excellent agreement, within an average 1.5% to 2.9%, was obtained between the predicted and measured modal frequencies of the stringer, frame and dome components. The predictions for the modal frequencies of the assembled component Configurations I through V were within an average 2.9% and 9.1%. Finite element modal analyses were performed for comparison with 3 psi and 6 psi internal pressurization conditions in Configuration VI. The modal frequencies were predicted by applying differential stiffness to the elements with pressure loading and creating reduced matrices for beam elements with offsets inside external superelements. The average disagreement between the measured and predicted differences for the 0 psi and 6 psi internal pressure conditions was less than 0.5%. Comparably good agreement was obtained for the differences between the 0 psi and 3 psi measured and predicted internal pressure conditions.

Grosveld, Ferdinand W.↗

Multi-parameter distributed fiber optic sensing using double-Brillouin peak fiber in Brillouin optical time domain analysis

In this paper, we demonstrate a multi-parameter fiber sensing system based on stimulated Brillouin scattering in a double-Brillouin peak specialty fiber with enhanced Brillouin gain response. The amplitude level of the second Brillouin gain peak, which originated from the higher-order acoustic modes, has been improved with an approximately similar amplitude level to the first Brillouin gain peak from the fundamental acoustic mode. Compared to other multi-Brillouin peak fibers presented in the literature, the proposed fiber significantly reduces the measured Brillouin frequency shift error, thus improving strain and temperature accuracies. By utilizing the sensitivity values of the strain and temperature associated with each Brillouin gain spectrum (BGS) peak, a successful discriminative measurement of strain and temperature is performed with an accuracy of ±13 μɛ, and ±0.5 °C, respectively. The proposed double-Brillouin peak fiber appears to be a possible alternative to other multi-BGS peak fibers, for instance, large effective area fiber and dispersion compensating fibers, which are inherently accompanied by large measurement errors due to the weak Brillouin gain values originating from the higher-order acoustic modes. The demonstrated results show different strain and temperature coefficients of 47 kHz/µɛ, 1.15 MHz/°C for peak 1 and 51 kHz/µɛ, 1.37 MHz/°C for peak 2. Moreover, the enhanced BGS peak gains having nearly the same amplitude levels enable the discriminative measurement of strain and temperature. Such fibers in Brillouin interrogation eliminate the need for complex monitoring setups and reduce measurement errors. We recommend that for long-distance natural gas pipeline monitoring, where discriminative strain and temperature measurement is crucial, the proposed double-Brillouin peak fiber can be highly beneficial.

47 OTHER INSTRUMENTATION↗

Determination of normal points for the relativity test of the celestial mechanics experiment

The relativity test is based on Mariner 9 tracking data acquired by the Deep Space Network. These data consist of two types of measurements: (1) two-way frequency difference (Doppler) measurements that are proportional to the tracking station-spacecraft range rate, and (2) signal round trip time-delay measurements that are proportional to the station-spacecraft range. A data compression scheme has been employed to alleviate accuracy and cost difficulties by (1) using the Doppler data to solve for the spacecraft orbit and to relate spacecraft position to the center of mass of Mars; and (2) combining this result with the station-spacecraft range measurements to obtain measurements of the Earth-Mars distance, called normal points, that contain all of the information pertinent to a detailed knowledge of the Earth-Mars motion.

Jordan, J. F.↗

Rate statistics for radio noise from lightning

Radio frequency noise from lightning was measured at several frequencies in the HF - VHF range at the Kennedy Space Center, Florida. The data were examined to determine flashing rate statistics during periods of strong activity from nearby storms. It was found that the time between flashes is modeled reasonably well by a random variable with a lognormal distribution.

Levine, D. M.↗

Comparison of Measured Flapwise Structural Bending Moments on a Teetering Rotor Blade With Results Calculated From the Measured Pressure Distribution

Flapwise bending moments were calculated for a teetering rotor blade using a reasonably rapid theoretical method in which airloads obtained from wind-tunnel tests were employed. The calculated moments agreed reasonably well with those measured with strain gages under the same test conditions. The range of the tests included one hovering and two forward-flight conditions. The rotor speed for the test was very near blade resonance, and difficult-to-calculate resonance effects apparently were responsible for the largest differences between the calculated and measured harmonic components of blade bending moments. These differences, moreover, were largely nullified when the harmonic components were combined to give a comparison of the calculated and measured blade total- moment time histories. The degree of agreement shown is therefore considered adequate to warrant the use of the theoretical method in establishing and applying methods of prediction of rotor-blade fatigue loads. At the same time, the validity of the experimental methods of obtaining both airload and blade stress measurement is also indicated to be adequate for use in establishing improved methods for prediction of rotor-blade fatigue loads during the design stage. The blade stiffnesses and natural frequencies were measured and found to be in close agreement with calculated values; however, for a condition of blade resonance the use of the experimental stiffness values resulted in better agreement between calculated and measured blade stresses.

Mayo, Alton P.↗