Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy system analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Deep Direct-Use Geothermal Feasibility Study for Hawthorne NV

The Hawthorne Nevada, deep direct-use geothermal study is a two-year effort funded by the U.S. Department of Energy to determine the techno-economic feasibility of implementing a large-scale, direct-use facility for the Hawthorne Army Depot (HAD) and the public facilities of the city of Hawthorne and Mineral County. The approach links a production side analysis (PSA) and a demand side analysis (DSA) into a whole-system analysis (WSA) to provide an integrated assessment of the resource and the probability of delivering economically viable direct-use energy to Hawthorne. Hawthorne, Nevada is in the western part of the Basin and Range province and has been the focus of geothermal investigations for over 40 years. Over the last 15 years, several studies completed by the U.S. Navy Geothermal Program Office (GPO) in conjunction with industry professionals quantified the existence of several low temperature geothermal prospects, the most promising of which is called Prospect A. The promise of Prospect A is based on drilling and flow testing that produced ~100 °C water at flow rates of up to 31 l/s (500 gallons per minute). Measured productivity indexes range from 40-85 l/s/MPa, suggesting a warm and productive heat source. Despite the promise of the resource, uncertainties in its spatial extent and long-term sustainability mean that techno-economic analyses must include probabilities of the sustainability of the resource under different operating scenarios. Here, the PSA is conducted by integrating a wide range of disparate data to estimate lognormal P90, P50, and P10 resource capacities. These capacities are used as input to a thermal-hydrologic (T-H) model to estimate thermal drawdown for each capacity estimate for several different DSA scenarios. Using a systems-based approach, the WSA links the dynamic T-H simulations of the PSA/DSA combinations with the techno-economic model GEOPHIRES to account for both the temporal dynamics and uncertainties in the system to produce probabilistic distributions of several performance metrics including the levelized cost of heat (LCOH) and the return on investment (ROI). This report is the final delivery for the project and documents the study's activities and results.

15 GEOTHERMAL ENERGY↗

Renewable Energy Technologies and Integrated Energy Systems

As renewable energy deployment expands, its integration into broader energy systems becomes an opportunity for providing clean energy across multiple sectors. This presentation will review statistics about the growth of renewable energy and potential future trends, with an additional focus technologies important to Colorado. It will also present options for integration with other low emissions technologies, such as nuclear energy and storage, and how together they could create an integrated energy system for multiple sectors. The presentation will also include an introduction to the mission and research of the National Renewable Energy Laboratory (NREL) and the Joint Institute for Strategic Energy Analysis (JISEA).

ENERGY PLANNING, POLICY, AND ECONOMY,ENVIRONMENTAL↗

Comparative Analysis of HEATNETS for Geothermal Network Performance

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification and validation process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study focuses on a validation of HEATNETS using results from TRNSYS. HEATNETS is not intended to replace other modeling tools, but this work demonstrates, via a comparison with an industry standard code, that HEATNETS can be a unique, high-level and rapid modeling tool for estimating the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

DER Planning with Resilience Analysis Using REopt Lite: A Behind-the-Meter Techno-Economic Analysis Tool

REopt Lite is a techno-economic decision support model for behind-the-meter energy systems design and dispatch modeling. REopt Lite is used to optimize energy systems for buildings, campuses, communities, and microgrids. It is based on a Mixed Integer Linear Programming (MILP) optimization model. It is a fully automated and streamlined energy modeling tool that can be used off-the-shelf for a wide variety of distributed generation integration analyses and at the same time is architected to be extensible for user-specific customizations for advanced users and subject matter experts. It is publicly available as a webtool as well as has an Application Programming Interface (API). The API functionality enables programmatic access to the model facilitating smooth integration with other distribution systems modeling tools, and automated multiple scenarios/sensitivity studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Testing, Operation, and Analysis of a Photosensitive LArTPC

TinyTPC, a compact LArTPC with a pixelated readout system (LArPix), aims to improve energy measurements for low-energy events by enhancing ionization charge collection. It explores the effects of photosensitive dopants and xenon in liquid argon. An initial look at adding photosensitive dopant isobutylene found a 5% charge enhancement.

McCright, Hannah↗

Sensitivity analysis of design parameters in RowWise borehole layout for ground heat exchangers

Ground source heat pump systems offer a promising pathway toward energy-efficient building heating and cooling. The performance and cost-effectiveness of these systems heavily depend on the design of the ground heat exchanger (GHE), particularly the spatial placement of boreholes used in large commercial buildings. Among various borefield layout strategies, the RowWise approach generates and optimizes borehole configurations within irregular polygonal land boundaries, providing land-use efficiency and installation flexibility. While multiple geometric design parameters constrain the RowWise layout, their influence on the system thermal performance and total drilling requirements remains unclear. Thus, this study presents a sensitivity analysis of key design parameters influencing the RowWise layout of vertical borehole GHEs, including the perimeter spacing ratio, borehole spacing, borehole field rotation angle, and borehole length. GHEDesigner and Ray Tune are employed to generate and assess different RowWise configurations. A series of parametric simulations was conducted to quantify the impact of each parameter on geometric distribution, economic cost, and computational speed. The results provide critical insights into the sensitivity and relative importance of different design parameters of RowWise method, offering practical guidance for designers aiming to optimize GHE layouts by balancing thermal efficiency, land constraints, and economic feasibility.

Xu, Dikai [Purdue University]↗

Mesoscale Convective Systems Dominate the Energetics of the South Asian Summer Monsoon Onset

The onset of the South Asian summer monsoon (SASM) is featured as an abrupt increase of precipitation and atmospheric column-integrated moist static energy (MSE). Using convection permitting simulations, a novel cloud tracking technique, and an MSE budget, the relative roles of mesoscale convective systems (MCSs) and non-MCS isolated deep convection in the SASM onset are studied. The analysis shows MCSs play a crucial role in the sudden increases of rainfall, diabatic MSE sources, and the subsequent enhanced export of column-integrated MSE during the onset. A “diabatic sources-energy export” plane analysis delineates the different roles of MCSs and non-MCS deep convection in the SASM onset. Although deep convection always leads to a net energy export, mesoscale organization of deep convection dominates the convection associated positive feedbacks that accelerate the energy cycle of the SASM onset. Sensitivity experiment shows that the results are insensitive to the model resolutions.

Chen, Xingchao↗

Paired Hydro-Battery Hybrid System Operations Using MIQP Based Multi-Objective Optimization

Hybridizing a hydropower plant with a battery energy storage system is often a very expensive decision. So to make the case for feasibility of hybridization the cost benefit analysis must be comprehensive. Most literature found on this subject only uses one out of many different available value streams to carry out a feasibility analysis. To that end, in this study we propose a multi-objective optimization formulation and a mixed-integer quadratic programming optimization engine that considers multiple different value streams and optimizes hydro-battery hybrid system paired operations to maximize revenue generated from energy arbitrage while simultaneously minimizing the total hydro turbine mileage thus reducing turbine starts and stops and improving turbines life all while following all environmental constraints and not violating any limitations either regulatory or preferential (i.e., to support recreational activities like white water rafting, etc.). In this study we also implemented the developed optimization methodology to a real-world case study of Bagnell dam hydropower facility (8 units totaling 240 MW rated power capacity) which is owned and operated by our industry partner Ameren Energy Inc. The case study outcomes shows that by hybridizing the Bagnell dam hydropower facility with a 60 MW x 2-hr battery energy storage system, the annual benefits can be increased over \$6 million while reducing the annual mileage averaged per turbine and number of start/stops by over 98\% and 85\% respectively.

Chalishazar, Vishvas H.↗

Technoeconomic Cost Analysis of NREL Concentrating Solar Power Gen3 Liquid Pathway: Preprint

The National Renewable Energy Laboratory is leading the liquid (molten salt) power tower pathway for the U.S. Department of Energy's concentrating solar power Gen3 initiative. The Gen3 liquid pathway required updated designs to three major components: the tower and receiver, the thermal energy storage (TES) tanks, and the power cycle. We assume a 100 MWe net system output and used the System Advisor Model (SAM) to complete a technoeconomic cost analysis of the Gen3 liquid pathway design and estimate its LCOE. This paper summarizes the methodology and results of that analysis.

chloride salt↗

Integration of Energy Storage in Fossil Energy Power Plants (ES-FE) Market Analysis

This analysis consists of identifying the economic signals for the integration of ES-FE concepts in major Independent System Operators (ISOs), such as Mid-Continent (MISO), Electric Reliability Council of Texas (ERCOT), California (CAISO), and Pennsylvania, Jersey, Maryland Power Pool (PJM). This piece of work came from our interest in understanding how and at what level an electricity market would renumerate a fossil energy power plant that integrates energy storage, meaning a fossil power plant that adds any type of energy storage to their power plant.

Pena-Cabra, Ivonne A.↗

Advanced Hydropower and PSH Capacity Expansion Modeling (Final Report on HydroWIRES D1 Improvements to Capacity Expansion Modeling)

Hydropower and pumped-storage hydropower (PSH) have played a key role in providing flexible, low-carbon electricity to the U.S. electricity system for over a century. As variable generation (VG) deployment increases the demand for flexible, dispatchable generation, it is important to use all available methods for understanding how hydropower and PSH interfaces with VG in a future low-carbon grid. Capacity expansion models (CEMs) of electricity systems are often used to study future electricity scenarios, but these tools often have difficulty representing site- and technology-details of hydropower and PSH due to limited spatial, temporal, or process resolution. This report demonstrates a set of model advancements to improve hydropower and PSH representations in CEMs and other models that consider hydropower and PSH's role in electricity systems. Model advancements include new data integration to define closed-loop PSH resource availability and cost, along with site-level parameterizations of existing PSH capacity and energy storage specifications. Shifting energy across seasons for both hydropower and PSH is explored to demonstrate the potential value of long-duration storage. New representations of hydropower upgrades offer opportunities to increase dispatchability, add pumps, or independently add capacity or energy depending on what is most valuable. New model structures and data are demonstrated individually and in combination to observe their impact on model results and provide initial insights into what is most important for analysts, electricity system planners, and hydropower decision-makers to consider when assessing future roles of hydropower. Improving flexibility of existing hydropower assets has the potential to reduce CO 2 emissions through complementing VG technologies and/or improve electricity system economics by reducing the need to deploy higher-cost systems. Large-scale energy storage is also shown to provide opportunities for balancing seasonal differences in VG, particularly solar photovoltaics (PV). Initial analysis with a new closed-loop PSH resource and cost dataset also demonstrate the potential for new PSH deployment to offer new grid flexibility opportunities. Future analysis and modeling of hydropower's role in the U.S. and other electricity systems could include methodological improvements based on those discussed here along with sensitivity analysis to better represent current and future potential hydropower and PSH flexibility. Improvements to geospatial and site-level data can further improve the understanding of how hydropower and PSH can be upgraded and operated in response to future electricity system needs. This work lays the groundwork to use advanced planning models to explore the range of roles hydropower and PSH can play in the grid of the future.

13 HYDRO ENERGY↗

Potential Adoption and Benefits of Co-Optimized Multimode Engines and Fuels for U.S. Light-Duty Vehicles

Exploring a diverse portfolio of technologies for decarbonization is crucial to understanding the potential impacts of different technological solutions and their associated environmental implications. Using high-octane, high-sensitivity biofuel blends in co-optimized multimode engines can increase engine efficiency and reduce vehicle emissions. Here, the multimode engine research focuses on the benefits of light-duty vehicle engines, which can operate in multiple modes depending on the vehicle's load. Low-temperature combustion can improve efficiency and reduce emissions (such as those from oxides of nitrogen and particulate matter) during low-load operation, while spark ignition performance is maintained in high-load operation. These advanced engines can be optimized to run on blends of biobased fuels. This analysis models scenarios for potential market adoption of co-optimized multimode vehicles fueled by three different bioblendstocks: ethanol, isopropanol, and isobutanol. An integrated modeling approach is used to forecast the energy and environmental impacts of the deployment of co-optimized multimode vehicles and fuels in the light-duty sector over the 2020-to-2050 time horizon. The multidisciplinary approach combines vehicle sales modeling, system dynamics modeling of the biorefining industry, and life cycle assessment to estimate the emissions and energy benefits. The models consider market forces such as consumer preferences for vehicle attributes, biofuel supply and demand dynamics subject to biorefinery capacity build-out and bioresource constraints, and forecasted changes to the U.S. bulk energy system over time. Market adoption of co-optimized vehicles is evaluated across a wide parameter space for incremental vehicle cost and engine efficiency improvement. This analysis reveals that the deployment of co-optimized multimode fuels and vehicles results in up to a 5% reduction in annual sector-wide life cycle greenhouse gas (GHG) emissions by 2050, relative to a business-as-usual scenario, but is also indicates environmental trade-offs, such as higher life cycle water-use. Emission benefits could potentially increase beyond 2050, as the new technologies penetrate the market and gain a foothold. Results also show that, under certain circumstances, vehicles with engines co-optimized for use with high-octane, high-sensitivity biofuel blends can be cost-competitive with conventional gasoline, while reducing GHG emissions. Our modeling results indicate that co-optimized multimode fuels and engines can be strategically leveraged in tandem with electrification to decarbonize the light-duty sector. Co-optimized vehicles could play a role in the early years of the time horizon, while electric vehicles (EVs) could become more competitive in the later years, highlighting the complementary benefits of these technologies for GHG reductions.

Oke, Doris↗

Geothermal Energy and Resilience in Arctic Countries

The eight Arctic countries - Iceland, Canada, Denmark (Greenland and the Faroe Islands) Norway, Sweden, Finland, Russia, and the United States (Alaska) - have diverse energy systems, but can be split into two distinct groups based on energy characteristics. The first group includes systems in Europe (Finland, Norway, Sweden, and Iceland), which are heavily grid-connected. The second group includes the United States (Alaska), Canada, Russia, and Greenland, which have grid-connected energy systems in their more densely populated southern regions, but are also defined by the prevalence of remote microgrids. Energy sources for heat and power vary across grid-connected communities in the Arctic nations. The primary energy source for remote communities, on the other hand, is almost exclusively diesel. This is true for both heat and power. Despite these and other key distinctions, Arctic countries share many commonalities with regard to their energy systems. One is a fundamental need for heat. Heat and electric energy are linked in most communities - remote, rural, and urban - and those linked systems are increasingly vulnerable to disruptions. Several of the Arctic countries use baseload renewable energy resources for heat and power. Iceland uses geothermal and hydroelectric; Canada, the United States, Sweden, Norway, and Finland use hydroelectric. Utilization of baseload renewable energy resources on-site for combined heat and power appears to enhance the resilience of communities in Arctic countries with high penetration of those resources. On the other hand, reliance on diesel by remote communities in other Arctic countries may be amplifying vulnerabilities. Although geothermal energy is currently used in all eight Arctic countries, resources are poorly mapped, and details can be difficult to come by. Despite this, geothermal energy provides heat and sometimes electricity at both utility scales and at the microgrid scale. Geothermal electricity is produced in Iceland, Russia, and the United States (Alaska). Direct use of geothermal heat is used in Iceland, Russia, United States, Canada, and Norway. Geo-exchange is used in Sweden, Finland, Norway, Canada, and the United States. In this paper, we reframe geothermal heat and power systems as integrated energy systems, asking the question: are integrated geothermal energy systems - where available and economic - resilient solutions for communities in Arctic countries? We identify resilience attributes of integrated geothermal energy systems, with a focus on microgrids and small-scale applications. Based on the high-level, qualitative analysis presented in this paper, the answer appears to be yes. Further work should prioritize refining our understanding of geothermal resources in Arctic countries, because development of the most economic geothermal resources in Arctic countries has the potential to enhance the energy resilience of its residents, whether in a grid-connected or remote off-grid context.

15 GEOTHERMAL ENERGY↗

Faster-than-real-time Simulation with Demonstration for Resilient DER Integration

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. The Faster-than-real-time Simulation with demonstration for Resilient DER Integration project set out to do the following: a. Flatten the voltage profile through the feeders and system for cost saving and voltage stabilization needs. b. Increase the amount of intermittent distributed energy resources (IDERs) that could be deployed on a utility feeder and provide 100% or more energy needed for the demands on that feeder, and c. based on an accurate model (Digital Twin) of the utilities system, be able to detect any abnormalities on the utilities distribution system. To manage the voltage and increase IDER penetration (a,b), Graph Trace Analysis is employed in a time-series, optimal power flow to coordinate the time-varying feedback control setpoints of a distribution feeder’s utility control devices. Under the coordinated control are a Load Tap Changing Transformer, a voltage regulator, and five switched capacitor banks. The feeder serves over 2000 customers, the feeder secondaries are modeled, and the feeder has 2.3 MW of PV generation, corresponding to a 17.4% penetration of PV generation. The feeder model has over 12,000 components, where every customer load bus and PV generator are modeled. The accuracy of the power flow solution is compared against historical meter voltage measurements, the improvement in conservation voltage reduction energy savings as a function of the coordinated control desired voltage profile is investigated, and the increase in PV penetration of the coordinated control over the existing control is presented. To achieve improved control performance while observing system operation constraints, bellwether Advanced Metering Infrastructure (AMI) voltage measurements are used to adjust the desired voltage profile used by the optimal power flow analysis. To detect and alleviate or negate attacks or failures on the distribution and transmission utility grids (c) the grid needs to be resilient and self-healing. In this project software was designed to do just that. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hard-ware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

Integrated System Model, Graph Trace Analysis, Adv↗

Long-Duration Energy Storage: Resiliency for Military Installations

This report provides a quantitative techno-economic analysis of a long-duration energy storage (LDES) technology, when coupled to on-base solar photovoltaics (PV), to meet the U.S. Department of Defense's (DoD's) 14-day requirement to sustain critical electric loads during a power outage and significantly reduce an installation's carbon footprint. The LDES modeled is Antora Energy's battery energy storage system (BESS). It is currently at a technology readiness level (TRL) of 7 and not ready for full-scale deployment. To support decisions on the value of near-term demonstrations, this analysis looked at the potential value of Antora Energy's BESS if deployed in the future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Umbilical Fatigue Analysis for a Wave Energy Converter

Unique umbilical designs for wave energy converters (WECs), including the ability to handle significantly larger motions and loads over long deployments, are often required when conventional marine umbilical designs for offshore oil and gas and offshore wind may not meet the design and cost needs of wave energy technologies. This study details a fatigue analysis of a dynamic power umbilical attached to a two-body floating point absorber WEC system, using the sea states provided for the PacWave testing facilities. The 6 degrees of freedom motion time history for the WEC was simulated, and the motions of the attachment point for the umbilical on the WEC and respective sea states were used to analyze the dynamic motions and fatigue of the connected power umbilical to predict the fatigue life. The results show that the fatigue damage observed is more significant in shallow water, and extensive fatigue damage may occur because of the larger curvature response of the umbilical. The umbilical configurations departing at 90 deg off incoming waves were found to have the highest fatigue life attributed to less extension or compression of the umbilical. However, additional bend stiffener/limiter features may need to be incorporated into the buoyancy section and touchdown regions to minimize curvature-induced fatigue.

50 EE - Wind and Water Power Program - Water (EE-4↗

MELCOR-TMAP: The integration of MELCOR for fusion and TMAP4 for fusion reactor systems safety analysis and tritium inventory tracking

The design of fusion reactors requires the prediction of radioactive tritium migration during normal operating conditions and accident scenarios. Safety standards such as those from the U.S. Department of Energy (DOE) require that fusion reactor designs limit the release of hazardous material to the environment. In addition to safety requirements, the rarity of tritium supplies for burning D-T fusion plasma requires tritium breeding blankets. Computational modeling of migration of tritium and various reaction products throughout the fusion reactor serves to create designs that fulfill these requirements. MELCOR-TMAP, owned and developed at Idaho National Laboratory (INL), is an integrated system-level engineering code adapted for the analysis of fusion reactor systems. The history of the conception and evolution of the MELCOR-TMAP code, as well as its current capabilities, recent updates including a corrected composite material wall nodalization scheme, and plans for future development, are discussed here.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Update on Parallel Process Execution in the Next Generation System Analysis Model

As of the end of 2021, 88,880 metric tons of heavy metal (MTHM) (44,741 MTHM in dry storage; 44,139 MTHM in wet storage) of spent nuclear fuel (SNF) were stored at various reactor sites across the United States [1]. The Office of Storage and Transportation in the Department of Energy is planning for the transportation, storage, and eventual disposal of SNF and high-level radioactive waste (HLW). To aid in this effort and inform decision-makers about the backend of the spent fuel cycle, systems analysis tools capable of analyzing the various options with respect to SNF and HLW management are being used as well as continuously improved to meet the evolving needs of the program. System analysts typically use these tools to vary underlying assumptions (shipping rates, allocation priority, available facilities, start dates, etc.) and study the implications of these changes on site clearance schedules, campaign costs, transportation infrastructure acquisition, etc.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗